  • Buderus Logamax plus GB142-24, 6 http://www.buderus.net For your safety INOTICE Indicates special instructions on installation, operation or maintenance that are important but not related to personal injury or property damage. 1.2 Safety instructions Make sure to observe these safety instructions. Failure to do so can result in property damage, personal injury or loss of life. – Installation, gas and flue connection, commissioning, electrical connection and maintenance activities must only be carried out by a trained service provider. – Certain work, e.g. on gas lines, ma

  • Buderus Logamax plus GB142-24, http://www.buderus.net 21 Operating and error messages Display Meaning Normal operation 1 Boiler in space heating mode Boiler in DHW heating mode Normal operation 1 Burner interval circuit, burner will restart automatically after 10 minutes Burner is started More capacity was delivered than required Ready for operation The gas valve is open Initializing, Pre Purge Flow temperature higher than set Table 5 Messages in normal operation mode 1 Push the "Service" button to display this operation message. 2 Is shown automatically, i. e. without you pushing a button. =/- -H =H 0 0A 0C 0E 0H 0L 0U 0Y

  • Buderus Logamax plus GB142-24, 10 http://www.buderus.net Lighting Instructions 2.2 Opening and closing the control panel z Briefly push the drawer to open the control panel (fig. 2). The drawer will come out. The control panel consists of the Logamatic BC10 basic controller (fig. 1). z Close the control panel by pushing it back into the boiler . 2.3 Switching on and off z Set the main switch on the BC10 to position "1" (On) to switch on the boiler and set it to "0" to switch it off. HCAUTION Risk of electric shock. If a hazardous situ

  • Buderus Logamax plus GB142-24, http://www.buderus.net 23 Operating and error messages 4.2 Identifying and resetting faults If a fault occurs, the error code flashes on and off on the display of the BC10 basic controller. z Push the "Reset" button for approx. 5 seconds to reset the fault. The display shows "rE" while resetting. Reset is only possible if there is a flashing error message. If the display then shows a normal operation message from table 5, this means that the fault has been remedied. If the fault recurs, you must repeat resetting two or three more times.

  • Buderus Logamax plus GB142-24, http://www.buderus.net 3 Contents 1 For your safety . . . . . . . . . . . . . . . . . . . . 5 1.1 Designated use . . . . . . . . . . . . . . . . . . . . . . 5 1.2 Safety instructions . . . . . . . . . . . . . . . . . . . . 6 2 Lighting Instructions . . . . . . . . . . . . . . . 8 2.1 Operating the BC10 basic controller . . . . . . 9 2.2 Opening and closing the control panel . . . . 10 2.3 Switching on and off . . . . . . . . . . . . . . . . . . 10 2.4 Setting the DHW temperature value . . . . . 11 2.5 Entering the space heating w

  • Buderus Logamax plus GB142-24, 16 http://www.buderus.net Starting up and shutting down the boiler z Open the gas shut-off valve (fig. 3, pos. 1). Lightly push on the gas shut-off valve and turn it to the left (counterclockwise). In "open" position the gas shut-off valve is parallel to the gas pipe. z Open the boiler manifold shut-off valves (fig. 3, pos. 2). Fig. 3 Opening the gas shut-off valve and the boiler manifold shut-off valves pos. 1: gas shut-off valve pos. 2: boiler manifold shut-off valves 1 2

  • Buderus Logamax plus GB142-24, http://www.buderus.net 9 Lighting Instructions 2.1 Operating the BC10 basic controller 1) ECO mode means that the temperature inside the hot water tank is 140 °F. Fig. 1 Logamatic BC10 basic controller – Controls pos. 1: Main switch pos. 2: DHW temperature knob 1) pos. 3: LED "DHW status" pos. 4: Display pos. 5: Space heating water temperature knob pos. 6: LED "Burner status" pos. 7: LED "Burner Operation" pos. 8: Service Tool connector pos. 9: "Service" button pos. 10:"Chimney sweep" button pos. 11:"Reset" button 190 170 150 130 90 110 140 130 120 90 100 110 42 1 5 711 910 3

  • Buderus Logamax plus GB142-24, http://www.buderus.net 13 Lighting Instructions 2.5 Entering the space heating water temperature z Turn the "space heating water temperature" knob to set the upper limit value of the heater water for the heating opera- tion. This limitation does not apply to DHW preparation. 190 170 150 130 90 110 Condition Explanation LED 0 Off No supply to heating system (only DHW heating operation). Off 90 – 190 Direct setting on BC10 in °F (90 – 190 °F) The temperature set on the BC10 is a tempera

  • Buderus Logamax plus GB142-24, 18 http://www.buderus.net Starting up and shutting down the boiler 3.2 Shutting down the boiler z Set the main switch on the basic controller to position "0" (Off). z Close the gas shut-off valve and disconnect the boiler from the power supply. ADANGER! The heating system may freeze if it is not operational in times of freezing weather. – Protect the heating system against freezing if there is a danger of frost affecting the system. – Drain the heating system water from the lowest point of the heating system using the boiler drain. The vent screw at the highest point of the heating

  • Buderus Logamax plus GB142-24, http://www.buderus.net 15 Starting up and shutting down the boiler 3 Starting up and shutting down the boiler 3.1 Starting up the boiler z Turn the "space heating water temperature" and "DHW temperature" rotary knobs to "Aut" (automatic mode). The control unit will now take control. 190 170 150 130 90 110 140 130 120 90 100 110 +

  • Buderus Logamax plus GB142-24, http://www.buderus.net 5 For your safety 1 For your safety GB142 condensing gas boilers are designed and built according to the latest technological advances and safety requirements. The design is specifically focused on ease of use. To ensure the safe, economical and environmen- tally friendly use of the heating system we urge you to read and observe the User's Instructions. 1.1 Designated use The GB142 was designed for heating water for a central heating system and for generating domestic hot water. The boiler can be fitted with a mo

  • Buderus Logamax plus GB142-24, 14 http://www.buderus.net Lighting Instructions 2.6 "Burner on" LED The LED indicates the operating condition of the burner. 2.7 Other functions and economic heating The functions described above are basic functions, carried out directly on the boiler using the Logamatic BC10 basic controller. LED Condition Explanation On Burner active The water in the boiler is being heated. Off Burner off The water in the boiler has reached the required temperature or there is no heat request. Table 4 LED indication

  • Buderus Logamax plus GB142-24, 20 http://www.buderus.net Operating and error messages Display (example) Meaning 1 Current boiler water temperature (in °F) 2 Current system pressure (in psi) 2 Operating message (see table 5): Current condition of heating system 1 Standard display for this operating condition. This display appears after 5 minutes if no button is pushed. 2 Other values may be displayed depending on the operating condition. You can return to the starting point by repea- tedly pushing the "Service" button. 140 P21 -H

  • http://www.buderus.net 19 Operating and error messages 4 Operating and error messages 4.1 Displaying operating messages In normal operating mode the display will show the current heater water temperature. You can display other information using the "Service" button. z Push the "Service" button a number of times to switch between the various

  • Buderus Logamax plus GB142-24, http://www.buderus.net 17 Starting up and shutting down the boiler z Set the main switch on the basic controller to position "1" (On). The basic controller checks the current system status and the burner becomes operational as soon as there is a heat request. This procedure takes approx. 30 seconds. z Adjust the settings on the control unit (see the Operating Instructions for the control unit).

  • Buderus Logamax plus GB142-24, http://www.buderus.net 7 For your safety – Never use chlorinated detergents or halogenated hydrocarbons (e.g. in spraycans, solvents and detergents, paints, adhesives) in the room where the boiler is installed. – When Calcium Chloride is present in concrete floors (when poured in winter) it is necessary to seal the floor with a suitable paint. – Do not allow too much dust to collect on the device. – Do not use the boiler if any part has been under water. Immediately call a trained service technician to inspect the boiler and to replace any part of the control system and any gas control which has

  • http://www.buderus.net 11 Lighting Instructions 2.4 Setting the DHW temperature value z Check the local code for the max. DHW temperature. z Turn the "DHW temperature" rotary knob to set the desired temperature of the hot water in the DHW tank. 1 This function has been optimized for boilers with combined DHW heating (combi-units). 2 The LED under the rotary

  • Buderus Logamax plus GB142-24, 2 http://www.buderus.net Warning: If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. – Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other boiler. – What to do if you smell gas • Do not try to light any boiler. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. • If you cannot reach your gas supplier, call the fire department. – Ins

  • Buderus Logamax plus GB142-24, 22 http://www.buderus.net Operating and error messages Test mode 1 Dot displayed in right-hand bottom corner Boiler in flue gas test mode (chimney sweep mode) Manual operation 1 Flashing dot in right-hand bottom corner Boiler in manual mode Water pressure too low 2 / Alternating display codes Water pressure is too low (between 3 and 12 psi). The value marked "P" indicates the current water pressure in psi. Contact the installer. Display Meaning Table 5 Messages in normal operation mode 1 Push the "Service

  • 4 http://www.buderus.net Preface About these instructions These user's Instructions contain important information for the safe and proper operation of GB142-24/30/45/60 condensing gas boilers. If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Subject to technical changes! Ch

Related Products and Documents (Boiler):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Aiwa XR-M800 Service manual aiwa/xr-m800-IM1.pdf 26 Jul 2023 6 4.39 Mb
2 Philips 52PFL7404H Brochure & specs philips/52pfl7404h-321.pdf 27 Jul 2022 3 2.01 Mb
3 Lexmark 1275n - Optra SC Color Laser Printer Service manual lexmark/1275n-optra-sc-color-laser-printer-U5F.pdf 27 Nov 2022 6
4 Toshiba 50HP16 Specifications toshiba/50hp16-472.pdf 22 Feb 2024 2 0.08 Mb
5 Denon AVR-3808CI Owner's manual denon/avr-3808ci-E59.pdf 23 Aug 2022 22 2.99 Mb
6 EnGenius EOA7530 Datasheet engenius/eoa7530-616.pdf 26 Mar 2023 5 0.19 Mb

Similar Resources:

  • Alde

    Compact 3020 HE

    (24 pages)
    Bruksanvisning & installationsanvisning – Compact 3020Operating & Installation Instructions – Compact 3020Gebrauchsanweisung & Montageanleitung – Compact 3020 …
  • saro

    ANCONA 5

    (15 pages)
    Modell ANCONA 5 (213-7500)Modell ANCONA 10 (213-7510)Modell ANCONA 30 (213-7515)Betriebsanleitung für ANCONAGlühwein- und HeißwasserspenderANCONA 5 ANCONA 10 ANCONA 15EnglishTranslation of the originalDeutsch - Original …
  • Glow-worm

    Energysaver Combi 100

    (36 pages)
    Hepworth Heating Ltd.,Nottingham Road, Belper, Derbyshire. DE56 1JTGeneral/Sales enquiries:Tel: (01773) 824141 Fax: (01773) 820569One Contact Local ServiceCustomer Services:Tel: (01773) 828100Fax: (01773) 828070221564F.11.00All replacement partsAll labour chargesAll call-out chargesThank you for installing a new Glow-worm appliance in your home.Glow-worm ap …
  • Pronteau

    PROBOIL.2

    (28 pages)
    PROBOIL.2User & Installaon Guidewww.proboil.co.uk See top of boiler for contact details Please read these instrucons carefully and retain for future reference.We have a policy of connued product and quality development and improvement. Accordingly we reserve the right to amend the specicaon at any me. All errors and omissions …
  • Potterton

    Suprima 100

    (38 pages)
    Installation & Service InstructionsSuprima 100Wall Mounted Fan AssistedBalanced Flue Gas BoilersSUP0003BTHE GAS SAFETY (INSTALLATION AND USE) REGULATIONS 1994 (as amended).‘‘ In your own interest, and that of safety, it is law that all gas appliances are installed by competent persons,in accordance with the above regulations. Failure to install appli …
  • Westen

    novadens Series

    (164 pages)
    wall-mounted condensing boiler instructions manual for users and fittersHастенные газовые конденcaтные котлыРуководство по эксплуатации и монтажуKondenzációs fali gázkazánokFelhasználói és szerelői kézikönyvCentrale murale cu gaz, cu condensare manual de instrucţiuni destinat utiliza …

Comments, Questions and Opinions: