  • Campbell NL241, Appendix D. Sending a New OS to the NL241 D-2 3. If the device is configured to create a network, the computer must join the NL241 created network. If the NL241 has been previously configured to join a network, join the same network with your computer. 4. Open DevConfig. 5. Select the NL241 under Device Type. 6. Ensure that the Use IP Connection box is checked on the left-hand panel. 7. If the Admin Password of the device has been set, you will need to enter that password in the Administrative Password control on the left panel in order for the connection to succeed. 8. Enter the IP

  • Campbell NL241, 1 NL241 Wireless Network Link Interface 1. Introduction The NL241 is a WLAN (wireless local area network) interface that allows Campbell Scientific dataloggers and peripherals to communicate with a Wi-Fi network. The NL241 can either join an existing network or create a network. This WLAN interface can be connected to a datalogger CS I/O port or RS-232 port. 2. Precautions • READ AND UNDERSTAND the Safety section at the front of this manual. • The first time an NL241 is attached to a datalogger and bridge mode is

  • Appendix C. NL241 Settings C-10 are observed by setting RS-232 Always On to Power Down Port when Inactive. RS-232 PakBus Beacon Interval This setting, in units of seconds, governs the rate at which the NL241 will broadcast PakBus® messages on the RS-232 port in order to discover any new PakBus neighboring nodes. It will also govern the default verification interval if t

  • Campbell NL241, NL241 Wireless Network Link Interface 13 Contains an embedded radio transmitter with the following approvals: FCC Identifier: XF6-RS9113SB Industry Canada: 8407A-RS9113SB View the EU Declaration of Conformity at www.campbellsci.com/nl241 6. Wi-Fi 6.1 Introduction to Wi-Fi for WLANs Wi-Fi is a technology that allows data transfer among electronic devices using specific radio frequencies over a wireless local area network (WLAN). A wireless network is like a wired network, except it uses radio waves jus

  • Campbell NL241, NL241 Wireless Network Link Interface 27 • On the NL241 tab: o Set Bridge Mode to disable. • On the RS-232 tab: o Set Configuration to TCP Serial Server. o Set Baud Rate to baud rate of attached device. o Make note of the Serial Service Port. (The default RS-232 Serial Service Port is 6784. Typically, it is not necessary to change this entry from its default.) CS I/O Serial Server Connect to the NL241 in DevConfig (see Section 7, Configuring the NL241 (p. 17)). • On the NL241 tab: o Set Bridge Mode to disable. • On the CS I/O tab: o Set Confi

  • Campbell NL241, Appendix C. NL241 Settings C-2 CS I/O IP Interface Identifier When the device is configured to operate in bridge mode, the datalogger will address the device using this identifier. The datalogger can address up to two CS I/O IP devices. The corresponding CS I/O IP Address settings in the datalogger will control the interface. CS I/O IP Interface 1 uses SDC channel 3. CS I/O IP Interface 2 uses SDC channel 1. Bridge Mode Forward Code When the device is configured for bridge mode, it forwards Ethernet packets to the datalogger. Because the device is aware of the MAC address and I

  • Campbell NL241, NL241 Wireless Network Link Interface 19 11. Configure the NL241 as needed for your application. 12. Click Apply to save your changes. 7.3 Configuring the NL241 with Telnet via Wi-Fi WLAN For security reasons, Telnet is disabled by default. It must be enabled from the Network Services tab in DevConfig. The NL241 must have an IP address before connecting via Telnet. Configuration via Telnet is not available in bridge mode. 1. Ensure the NL241 is powered and connected to your network. 2. Create a telnet session with the device over port 23. 3. Type the NL241 admin password (default password is NL241). 4. Type help to see a list of the functionality availab

  • NL241 Wireless Network Link Interface 22 collection of a network of dataloggers every 15 minutes, consider setting the Verify Interval to 30 minutes. Neighbors Allowed (RS-232 port only) – You can set a list of “acceptable neighbors” which the NL241 expects to hear from within set intervals (the verify interval). If the NL241 does not hear from neighbors in this

  • Campbell NL241, Table of Contents iii Figures 3-1. NL241 with CR800 (powered through CS I/O port) ............................ 2 4-1. NL241 .................................................................................................. 8 4-2. Bridge mode enabled ........................................................................... 8 4-3. Bridge mode disabled ........................................................................... 9 5-1. NL241 dimensions ............................................................................. 11 6-1. Infrastructure network ........................................................................ 14 8-1. PakBus® router LoggerNet setup

  • Campbell NL241, Appendix B. Cables, Pinouts, LED Function, and Jumper B-3 B.6 Power Jumper If you wish to prevent the NL241 from being powered over the CS I/O port, remove the two screws on the top of the NL241, remove the NL241top cover, remove the jumper above the red LED and place it so that it is connected to only one post. With the jumper connected to only one post, the NL241 can only be powered from the barrel connector. With the jumper connected to both posts, the NL241 can be powered from the CS I

  • NL241 Wireless Network Link Interface 36 6. Make sure the IP address and port number entered in LoggerNet/PC400/RTDAQ match the settings in the NL241. • Note that PakBus® and serial server communications use different port numbers. The default port number for PakBus communications is 6785. The default port number for CS I/O serial server communications is 6783. The default port number

  • Campbell NL241, Safety DANGER — MANY HAZARDS ARE ASSOCIATED WITH INSTALLING, USING, MAINTAINING, AND WORKING ON OR AROUND TRIPODS, TOWERS, AND ANY ATTACHMENTS TO TRIPODS AND TOWERS SUCH AS SENSORS, CROSSARMS, ENCLOSURES, ANTENNAS, ETC. FAILURE TO PROPERLY AND COMPLETELY ASSEMBLE, INSTALL, OPERATE, USE, AND MAINTAIN TRIPODS, TOWERS, AND ATTACHMENTS, AND FAILURE TO HEED WARNINGS, INCREASES THE RISK OF DEATH, ACCIDENT, SERIOUS INJURY, PROPERTY DAMAGE, AND PRODUCT FAILURE. TAKE ALL REASONABLE PRECAUTIONS TO AVOID THESE HAZARDS. CHECK WITH YOUR ORGANIZ

  • Campbell NL241, Campbell Scientific Companies Campbell Scientific, Inc. 815 West 1800 North Logan, Utah 84321 UNITED STATES www.campbellsci.com • [email protected] Campbell Scientific Africa Pty. Ltd. PO Box 2450 Somerset West 7129 SOUTH AFRICA www.campbellsci.co.za • [email protected] Campbell Scientific Southeast Asia Co., Ltd. 877/22 Nirvana@Work, Rama 9 Road Suan Luang Subdistrict, Suan Luang District Bangkok 10250 THAILAND www.campbellsci.asia • [email protected]

  • NL241 Wireless Network Link Interface 21 8.1.2 Create a Network In this configuration, the device will be the creator of a network. A network created by the module supports up to 8 joinees. Please remember when joining a network with Windows or iOS, it can take some time to successfully join the network. 1. Connect to the NL241 in DevConfig (see Section 7, Configuring t

  • Campbell NL241, NL241 Wireless Network Link Interface 24 8.2.1.4 Connect You are now ready to connect to your datalogger using the LoggerNet Connect screen. 8.2.2 Bridge Mode With bridge mode enabled, the device will act as a bridge from WLAN to CS I/O. All IP packets that come into the device via WLAN will be communicated as a complete Ethernet/TCP packet to the datalogger over the CS I/O port. This enables the datalogger to use its TCP/IP stack to interpret the packet and, therefore, all of the datalogger TCP services are available. In bridge mode, only the Wi-Fi settings are valid. All other functionality is disabled. All settings (that is, IP, netmask, gateway) are configured in the dat

  • Campbell NL241, NL241 Wireless Network Link Interface 3 3.2 Configuring the NL241 INSTALL THE DEVICE DRIVER BEFORE plugging the NL241 into your computer for the first time. You will need the device driver properly installed before you can connect to the NL241 via USB. To install the device driver, download the latest version of DevConfig from our website. Under Device Type, select Network Peripheral | NL241. Click the Install USB Driver link and follow the prompts. 1. Ensure the NL241 is powered. 2. Connect the supplied USB cable between a USB port on your computer and the USB port o

  • Campbell NL241, Appendix C. NL241 Settings C-8 TCP Serial Client The device will maintain a TCP client connection with a remote server. The IP address and port number of the remote server are configured in the settings RS-232 TCP Serial Client IP Address and RS-232 TCP Serial Client Port. Data received on the RS-232 port will be forwarded to this TCP connection, and data received on the TCP connection will be forwarded to the RS-232 port. The device will attempt to open a connection with the remote server and if the connection fails to open, the device

  • Campbell NL241, Appendix A. Glossary A-2 PakBus® Campbell Scientific’s packet-switched communications protocol. Packets of information transmitted between PakBus devices contain user data and administrative information (a header) that routing devices use to move the packets to their ultimate destination. PakBus devices examine the header information and then either remove the header (at the packet’s final destination) or forward the packet to another PakBus device. PakBus® Node A device in a PakBus network. Each device in a network must have a unique PakBus address. Port Number A port number is a way to identify a specific process to which a n

  • Campbell NL241, NL241 Wireless Network Link Interface 17 timeout that is refreshed every time communications are detected. Once the timeout has expired, the device will power off the network. If the Mode button is pressed again while the temporary network is active, the device will power off the network. The following graphic illustrates the possible Wi-Fi and Mode button configurations. 7. Configuring the NL241 The NL241 is configured using DevConfig 2.15 or greater. You can connect your NL241 to DevConfig using either a Wi-Fi connection or USB. 7.1 Configuring the NL

  • Campbell NL241, NL241 Wireless Network Link Interface 6 6. The following screen appears. Press the PB icon to cause LoggerLink to search for attached PakBus devices. For the PakBus search to work with the NL241, you must have LoggerLink version 1.6 or later. 7. The datalogger should be discovered automatically. Select the datalogger, and all necessary fields in the Logger Setup screen will be filled in automatically. To enter the information by hand, manually type the IP address of the NL241 in th

  • Campbell NL241, NL241 Wireless Network Link Interface 2 3. QuickStart Out of the box, the NL241 is configured for operation as a PakBus® router and to create an open Wi-Fi network called “NL241_SerialNumber”. In this mode, the NL241 can be used to communicate with Campbell Scientific PakBus devices using a Wi-Fi-enabled device such as a smart phone. The following instructions indicate how to use an NL241 to connect to a datalogger using a smart phone with Campbell Scientific’s LoggerLink Mobile App. 3.1 Physical Setup As shown in FIGURE 3-1, attach an antenna to the NL24

More Instructions:

DOWNLOAD

Related Products and Documents (Network Card):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Syscom Video EPMON19LED Operation & user’s manual syscom-video/epmon19led-4PM.pdf 05 Feb 2023 18
2 One for All 14432 Quick installation manual one-for-all/14432-P2O.pdf 06 Oct 2022 2
3 Intashield IS-400 Specifications intashield/is-400-861.pdf 03 Feb 2023 1
4 Canon LBP-1760 Service manual canon/lbp-1760-KX6.pdf 24 Feb 2023 248 7.26 Mb
5 Gigabyte GA-MA74GMT-S2 Operation & user’s manual gigabyte/ga-ma74gmt-s2-84T.pdf 29 Aug 2022 100 15.5 Mb
6 Panasonic NV GS400EG-S Brochure & specs panasonic/nv-gs400eg-s-EHE.pdf 05 Aug 2022 4 0.06 Mb

Similar Resources:

  • Telstrat

    NTU-45

    (2 pages)
    S/I Number Item Description511/692 NTU-45, HSSI B/U 48VDC+240VAC Power Pack511/693 NTU-45, HSSI B/U 48VDC511/722 Power Pack, 48VDC for NTU-45/45E -AULT511/694 Power Pack, 240VAC – 48VDC for NTU-45511/695 NTU-45 Module,V35 Service Interface511/696 NTU-45 Module,HSSI Service Interface511/707 Tray, Cable for NTU-4561200660L1-13ANTU-45Q …
  • Intel

    SBC83675

    (1 pages)
    * All the specifications and photos are subjected to be changed without notice.Embedded Computing PlatformsECP Servicesand SolutionsSTX SoM &BaseboardsMini ITX and LPX SBCs3.5" Capa BoardsEPIC Boards5.25" Petit Boards& AccessoriesPower SupplyAppendixHalf-size CPU Cards, BackplanesPC/104 & Mini PCIModulesEmbeddedeBOX System& MicroBox …
  • Nortel

    Communication Server 1000

    (144 pages)
    CallPilotRelease 4.0Document Number: 555-7101-510Document Version: Standard 1.16January 2007Communication Server 1000 Meridian and CallPilot Server Configuration …
  • HP

    zx2000

    (4 pages)
    read before installingATI™ FIRE GL™ X1 and Z1graphics cards before you beginBefore you install your new graphics card, please do the following:ÄCAUTION: When handling your card always wear a properly grounded wrist strap and handle the card carefully since it is susceptible to electrostatic shock.■ Refer to the Technical Reference or Operations And Ma …
  • HP

    Compaq NC8230

    (61 pages)
    Getting Started HP Compaq Notebook Series Document Part Number: 372369-001 February 2005 This guide explains how to set up your hardware and software and begin using your notebook. Enhanced for Accessibility. …
  • TYAN

    Thunder S2462

    (2 pages)
    www.tyan.comS2462Thunder K7Tyan's Thunder K7 is the world's first dual-processor platform for the AMD Athlon MPprocessor. This high-quality, feature-richsystem board provides cutting-edgeperformance for today's most demandingworkstation and server applications, andincludes powerful connectivity andmanagement features. The Thunder K7features th …

Comments, Questions and Opinions: