Manualios.com

Canon CXDI-50G Service Manual

Canon CXDI-50G Manual Online:

3.8, 757 votes
Canon CXDI-50G User Manual
Canon CXDI-50G User Guide
Canon CXDI-50G Online Manual

Text of Canon CXDI-50G User Guide:

  • Canon CXDI-50G, 2. Installation Manual - 74 - <Reference 2> Example when the graph does not form a straight line In the data and graph below, the data was obtained by using the Kodak MLP 190 to print out the SMPTE test image, and the image data was measured. (1): Shows normal data. (2): Shows the case when the CXDI printer parameters are not set linearly. (3): Shows the case when the printer was not calibrated properly. SMPTE Densit y Step 1 2 3 4 5 6 7 8 9 10 11 Percentage 0 10 20 30 40 50 60 70 80 90 100 0.17 0.46 0.75 1.03 1.36 1.66 1.98 2.29 2.59 2.90 3.20 (2) Inadequat

  • ror Code List for Versi Error Code List for Version 6.00 Error Code Seriousness Reply Keys Message [Cause] [Operation after Reply Key is touched] -126 Error OK #1:Error #2:Sensor Unit:Temperature Error #3:The internal temperature of the Sensor Unit exceeded the temperature limit. Cannot capture images until the temperature goes below the limit. #4:TEMP OVER (n)(

  • Canon CXDI-50G, 2. Installation Manual - 55 - Examples of parameters used with different makers and types of printers (reference) Name Default Parameters Significance Kodak MLP190 -A 320 -T NO -M CUBIC –m NORMAL -S CS000 (entered in param member) 80 (entered in pixelPitch member) 14 x 17 4096 (entered in W member) 5120 (entered in H member) • Trimming OFF • Cubic spline interpolation • Smoothing: normal • Maximum density: 3.20 • Curve shape 0 (density linear) as Config Info Kodak KELP2180 + Kodak Print Spooler Model 100 -A 320 -T NO -M CUBIC –m NORMAL -S CS000 (entered in param member) 79 (entered in pi

  • Canon CXDI-50G, 2. Installation Manual (2) Checking the Firmware Version 1) Purpose 1-1) Failing to use the proper versions of the firmware and PLD code with the CXDI application can result in an error, and system operation cannot be guaranteed. Therefore, the versions of the firmware must be checked to ensure that they are correct. (The combination of this firmware refers to CXDI Software Combination List.) 2) Notes 2-1) This check should always be performed at installation, and if necessary, the firmware versions should be upgraded. 2-2) This check cannot be performed with only the control PC. Connect the imaging units and other equ

  • Canon CXDI-50G, ror Code List for Versi Error Code List for Version 6.00 Error Code Seriousness Reply Keys Message [Cause] [Operation after Reply Key is touched] -514 Warning RETRY CANCEL #1:Warning #2:External Storage Error: #3:The exposed images cannot be stored because the size of folder partition is smaller than the exposed images. Use a new disk, erase the folder contents or enlarge the folder size and retry. (The size of folder partition: xxxxMB) (The size of exposed images: xxxxMB) [Cause] Images cannot be stored into the folder when the folder size of the external storage medium is smaller than a study. [Operation after Re

  • P P r r i i n n t t e e d d b b y y C C a a n n o o n n I I n n c c . . O O c c t t . . 2 2 0 0 0 0 3 3 R R e e v v . . 0 0 2 2 2 2 . . I I n n s s t t a a l l l l a a t t i i o o n n M M a a n n u u a a l l C C a a n n o o n n I I n n c c . .

  • Canon CXDI-50G, 3. Function 8 4 4 A A b b o o u u t t t t h h e e P P o o w w e e r r B B o o x x I I n n i i t t i i a a l l i i z z a a t t i i o o n n S S w w i i t t c c h h Initialization Switch The LAN can be started with the factory settings when you turn on the power (the main power of the power box and remote switch) by holding down the initialization switch (see figure *1 ) of the power box. The 50G firmware contains the initialization and normal codes. (They are stored in the PCB-50Di flash ROM) Normally, the normal code runs on a steady basis, and only

  • Canon CXDI-50G, ror Code List for Versi Error Code List for Version 6.00 Error Code Seriousness Reply Keys Message [Cause] [Operation after Reply Key is touched] -522 Fatal OK #1:Fatal Error #2:File Open Error:filename #3:File is not found. [Cause] For some reason, XXXX.BIN and XXXX.DCM files do not exist. Or, they cannot be read. [Operation after Reply Key is touched] Shutting down starts. Although this problem can be solved by using the service tool, users must not use the service tool on their own. Take necessary actions in acco

  • Canon CXDI-50G, ror Code List for Versi - 23 - Error Code List for Version 6.00 Error Code Seriousness Reply Keys Message [Cause] [Operation after Reply Key is touched] -506 Attention OK #1:Attention #2:DICOM Response Warning #3:Although transfer finished properly, receiving device reported a warning in DICOM response. Check receiving device. [Cause] DICOM response was received properly. However, the target reported a warning as a response. [Operation after Reply Key is touched] Checks only if the system is OK because the system is normal. -508 Attention OK #1:Attention #2:DICOM Printer Status Warning #3:Although transfer finished normally, receiving devi

  • Canon CXDI-50G, ror Code List for Versi Error Code List for Version 6.00 Error Code Seriousness Reply Keys Message [Cause] [Operation after Reply Key is touched] -504 Warning RETRY CANCEL #1:Warning #2:DICOM Parameter Error #3:DICOM transfer Parameter is wrong. [Cause] DICOM transfer parameters are not correct. [Operation after Reply Key is touched] When RETRY is chosen, the image will be transferred again. When CANCEL is chosen, transfer will be canceled after displaying a confirmation message. Enter the correct param

  • Canon CXDI-50G, 2. Installation Manual - 38 - 2) Procedure 2-1) Start up the CXDI system. 2-2) After the exposure screen appears on the operation unit, use the keyboard to enter Debug mode. (Use [Alt] + [Tab].) 2-3) “Welcome to CCR” screen appears. Select the command “1. Set-Up…” 2-4) The “Setting Mode (0: Normal, 1: Expert) [0=0×0]:” is prompted. Select “0: Normal” 2-5) “CCR SETUP MENU” appears. Select the command ”1. System Setup”. 2-6) “CCR Serial Number [0=0×0] : ” appears. Enter the six-digit number indicated on the naming label of the control PC unit. Press [Enter] key until “CCR SETUP MENU” appears. [Fig 1] Enter here [Fig 1] 2-7)

  • 2. Installation Manual - 82 - (16) Tool Modes (/np mode) 1) Purpose The tool modes (startup options) are intended in order to check operation, and are used to launch the CXDI application on the control PC by itself, and to display items that are not normally displayed. 2) Notes The following operation must be performed before using the “/np” mode. Especia

  • 2. Installation Manual 23 Explain the operation to the user Operation Manual 24 Final parameter adjustment -The engineer in charge must be consulted prior narrowing down the adjustments to the final values. Operation Manual 25 Inserting the backup floppy disk. -It must be confirmed at re-start that backup files have been made. -No necessary f

  • Canon CXDI-50G, 2. Installation Manual - 81 - (15) Backing up Setting Data to FD 1) Purpose “Important setting data (setting information which differs for each customer.)” is backed up to floppy disks and hard disks in consideration of possible setting data loss, hard disk corruption or other data errors. In the event that setting data is lost or the hard disk is corrupted, this “Important setting data” can be quickly restored to the condition before the trouble occurred by copying from the backup data. 2) Notes 2-1) Performing this backup work me

  • Canon CXDI-50G, 2. Installation Manual - 80 - (14) Backing Up When Installing 1) Purpose In case of re-installing the CXDI application, the necessary files ex) the exposure position and other parameters must be backed up so that can be restored at the status of first installation. 2) Necessary items 2-1) Removable drive such as MO drive or external HDD that can connect to USB 2.0 3) Notes 3-1) Before performing backup procedure, delete any “BodyPart” and image data exposed for tests. Deleting image data: Refer to the “Deleting Data” item. Deleting “BodyPart”: Refer

  • Canon CXDI-50G, 2. Installation Manual - 54 - * Both the -p and -v parameters should be used. These settings override the - s parameter. -V filename This parameter dumps the transfer log. * The parameter is used for analysis after the transfer software saves the debugging character string displayed on the console to a file with a designated filename. It is used only when problems occur. * This parameter does not affect DICOM data transfer. -I A-RELEASE-RES is ignored. * This parameter is used simply as “-I�

  • Canon CXDI-50G, 4. Repair Guide 1.6 Attaching the PCB-50Di Screw x12 Connect point (Below) Connect point (Upper) Hold 1. Remove the flat cable. 2. Loosen the screw (M2.6 x 12) fixes the PCB-50Di and remove it. Note: 1. At assembling, insert the connector carefully in the direction of the flat cable. 2. At assembling, there must not be a foreign body on the spacer sheet. 3. Exchange the flat cable for parts with a new one used one. 6

  • Canon CXDI-50G, 2. Installation Manual (3) Installing Firmware and PLD Code 1) Purpose Write exposure code and PLD code into the Flash ROM of the 50Di PCB in the imaging unit. 2) Notes Be sure to check that the CXDI is connected to the system. 3) Procedure 3-1) Installing the firmware Write the firmware by referring to “Firm Write Tool Software (Firmwrite.exe)” in the Tool Software Operation Manual for CXDI-50G. Where to write: IC1 (Flash ROM) on 50Di PCB 3-2) Installing PLD code Write PLD code by referring to “PLD Write Tool Software (pldwrite.exe)” in the Tool Software Operation Manual for CXDI-50G. Where to write:

  • Canon CXDI-50G, 2. Installation Manual - 56 - • The Kodak service engineer is responsible for setting the smoothing type on-site since it can be changed with each printer. • The rest is done by the printer itself. Kodak Imation DryView 8700+9440 -A 320 -T NO -M CUBIC –S “LUT=m, n”-m (on-site adjustment) (entered in param member) 78 (entered in pixelPitch member) 4096 (entered in W member) 5220 (entered in H member) The model 8800 has a rotation function but we understand that Imation has not publicly acknowledged the use of this function. • Trimming OFF • Cubic spline interpolation • Maximum density: 3.20 • S LUT = m, n is designated

  • 2. Installation Manual - 46 - D. After setting the output destinations, follow the procedure below to check whether images can actually be transmitted. Return to the user menu, capture a sample image (one X-ray image), and transmit the image to the printer and storage. There are two errors that may result if the image cannot be transmitted: a. “DICOM Connect Error.

  • Canon CXDI-50G, P P r r i i n n t t e e d d b b y y C C a a n n o o n n I I n n c c . . O O c c t t . . 2 2 0 0 0 0 3 3 R R e e v v . . 0 0 1 1 6 6 . . T T r r o o u u b b l l e e s s h h o o o o t t i i n n g g C C a a n n o o n n I I n n c c . . J J a a p p a a n n C C o o p p y y r r i i g g h h t t ( ( C C ) ) C C a a n n o o n n I I n n c c . . M M e e d d i i c c a a l l T T e e c c h h n n i i c c a a l l S S e e

Related Products and Documents (Medical Equipment):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 ButterBallll 23011014 Operation manual & safety instructions butterballll/23011014-5N3.pdf 24 Jun 2022 16
2 Marstair 526 HL Series Technical manual marstair/526-hl-series-UGI.pdf 23 Feb 2023 31
3 Kenwood TK-3170 Service manual kenwood/tk-3170-SG7.pdf 03 Jan 2023 73
4 Fujitsu PRIMERGY RX100 S8 Operating manual fujitsu/primergy-rx100-s8-218.pdf 24 Sep 2022 82 1.43 Mb
5 Electrolux FAVORIT 35010 I Operation & user’s manual electrolux/favorit-35010-i-4QC.pdf 30 Aug 2022 36 1.86 Mb
6 Zenoah BK3400FL Parts list zenoah/bk3400fl-178.pdf 08 Oct 2023 12 0.25 Mb

Similar Resources:

  • Vermeiren

    ILLICO

    (116 pages)
    VERMEIRENIllicoI N S T R U C T I O N M A N U A LM A N U E L D ' U T I L I S A T I O NG E B R U I K S A A N W I J Z I N GG E B R A U C H S A N W E I S U N GM A N U A L E D I I S T R U Z I O N IM A N U A L D E I N S T R U C C I O N E SI N S T R U K C J A O B S Ł U G IN Á V O D K O B S L U Z E …
  • SleepGuard

    SG5

    (19 pages)
    SG5 USER’S MANUAL IMPORTANT: Unless you are an expert in both Electromyographic Measurement and Subconscious Response Conditioning, please read this manual completely before using your SleepGuard biofeedback headband, and save these instructions. Holistic Technologies LLC 71 Forest …
  • Proactive Medical

    Protekt Aire 9900

    (28 pages)
    UML-P1509006-E-2022/04 Protekt® Aire 9900 True Low Air Loss Mattress System with Alternating Pressure & Pulsation Instructions For Use Proactive Medical Products 270 Washington Street Mount Vernon, NY 10553 Phone# 1-855-BE-PROACTIVE (855-237-7622) Fax# 845-205-6005 www.proactivemedical.com …
  • Cardionics

    SimulScope

    (31 pages)
    a Operator’s Manual SimulScope Bedside Auscultation System Cardionics 910 Bay Star Blvd. Webster, Texas 77598 USA Telephone: 281-488-5901 Fax: 281-488-3195 Email: [email protected] Web site: www.cardionics.com Copyright 2012 Cardionics All rights reserved Manual p/n: : 014-7003 Rev: C Revised:April 25, 2012 …
  • North Coast

    Hemi Sling NC15999

    (2 pages)
    North Coast Hemi Sling© 2011 North Coast Medical, Inc., www.ncmedical.comGilroy, CA 95020, 800-821-9319 REV15999I_0611IndicationsUse the North Coast Hemi Sling to help reduce subluxation or dislocation of the glenohumeral joint.The North Coast Hemi Sling employs a unique three point pressure design to help reduce shoulder subluxation or dislocation. Where …
  • Flaem

    AlphaNeb

    (76 pages)
    ITALIANOPag. 1ENGLISHpg. 9FRANÇAIS Pag. 25NEDERLANDSPag. 33ESPAÑOLPÁG. 41DEUTSCHPag. 17 65C1.4C1.3C1.2C1.1C1C5C4C3C2C1A1 A6A5A7A2A4A3IT > MANUALE ISTRUZIONI D’USOEN > INSTRUCTIONS FOR USE MANUALDE > BEDIENUNGSANLEITUNGFR > MODE D’EMPLOINL > GEBRUIKSAANWIJZINGES > MANUAL DE INSTRUCCIONESEL > ΕΓΧΕΙΡΙΔΙΟ ΟΔΗΓΙΩΝ Χ …

Comments, Questions and Opinions: