Text of Cronyx Qlink-3000/2E1 User Guide:

  • Cronyx Qlink-3000/2E1, Qlink-3000 Multiplexing modem Copyright © 2003 -2005 Cronyx Engineering 45 Section 5. Management via SNMP The Qlink-3000 multiplexing modem may be equipped with a SNMP control port. The SNMP control port is located on the front panel, and has a standard Ethernet 10Base-T interface (RJ-45). The SNMP protocol allows to view current device modes, link states, local and remote error statistics, to change configuration parameters, and to enable diagnostic modes.

  • Qlink-3000 Multiplexing modem Copyright © 2003 -2005 Cronyx Engineering 48 Qlink-3000 Multiplexing modem Copyright © 2003 -2004 Cronyx Engineering Cronyx Engineering Marshala Sokolovskogo 4, Moscow, Russia 123060 Phone/Fax: +7 (095) 742-1771 WWW: www.cronyx.ru FTP: ftp.cronyx.ru E-mail: [email protected]

  • Cronyx Qlink-3000/2E1, Qlink-3000 Multiplexing modem Copyright © 2003 -2005 Cronyx Engineering 19 6 Remote SHDSL port status and mode indicator (LINK-REM) This indicator shows the remote SHDSL port status and mode. If information about the remote side is unavailable (connection not established, or service link does not operate due to errors), then the LINK-REM indicator does not light. Color shows the port status: green - connection established, no errors (OK), red - error (CRC anomaly, LOSW defect, Loop attenuation defect, SNR marg

  • Cronyx Qlink-3000/2E1, Qlink-3000 Multiplexing modem Copyright © 2003 -2005 Cronyx Engineering 15 Emergency alarm connector to Qlink3000 console (DB9 male) to Control terminal Cable without modem control GND 5 TXD 3 RXD 2 RTS 7 CTS 8 DTR 4 CD 1 GND TXD RXD RTS CTS DTR DSR CD Cable with modem control GND 5 TXD 3 RXD 2 RTS 7 CTS 8 DTR 4 DSR 6 CD 1 GND TXD RXD RTS CTS DTR DSR CD to Qlink3000 console (DB9 male) to Control terminal A DB-9 (female) connector is used for emergency alarm connection. The external input sensor (pins 3 and 7) must be isolated from other electrical circuits. Pins 1, 2 and 6 are reserved and must not be used. 3 - input contact

  • Qlink-3000 Multiplexing modem Copyright © 2003 -2005 Cronyx Engineering 37 The BER tester may be enabled towards the SHDSL link only: • Link test – over full payload; • Port 0 tributary test – over port 0 tributary; • Port 1 tributary test – over port 1 tributary; In order to view test results, select the “Test results...” item: Port 0 Tributary Bit Error Test Bit error rate: 0.0

  • Cronyx Qlink-3000/2E1, Qlink-3000 Multiplexing modem Copyright © 2003 -2005 Cronyx Engineering 25 Local loop on the link Local device: link loop Remote device: normal operation Port 0 (E1) Port 1 (ET H) Port 0 Port 1 AIS When the loop is enabled on the SHDSL link, the data received from the link are turned back. In this case, local and remote Ethernet ports are disconnected from the link, and the AIS signal is output to local E1 port(s). The LINK-LOC indicator blinks (single flashes), its color depends on the SHDSL port status: red - connection not established, or errors in the link (CRC anomaly, LOSW defe

  • Cronyx Qlink-3000/2E1, Qlink-3000 Multiplexing modem Copyright © 2003 -2005 Cronyx Engineering 11 Section 2. Installation 2.1. Installation place requirements The device must be grounded before switching on, there is a ground terminal screw on the front panel provided for this purpose. When installing the multiplexing modem, allow for at least 10 cm of free space next to the front panel for interface cable connections. The ambient temperature must be 0 to +50 °C at 80% humidity, no condensation. 2.2. Delivered items Delivered items include: • Qlink-3000 unit – 1 pc.; • bracket for mountin

  • Cronyx Qlink-3000/2E1, Qlink-3000 Multiplexing modem Copyright © 2003 -2005 Cronyx Engineering 18 Green No Normal operation (no alarm indication signal from the remote). Red No Alarm indication signal received from the remote (bit A of the zero timeslot). Red Single Loss of the G.703 signal in the link (LOS), alarm indication signal (AIS) received, no frame (LOF) or multiframe (LOMF) synchronization. BER tester is enabled on port tributary or local loop enabled towards the G.703 link. Red Blinks Port tributary loop enabled (in this case the E

  • Cronyx Qlink-3000/2E1, Qlink-3000 Multiplexing modem Copyright © 2003 -2005 Cronyx Engineering 10 Diagnostic modes Loops .............................................................. Local, remote Error rate control ............................................ Built-in Control ............................................................ Via the RS-232 control port, via the SNMP interface, or from a remote device Dimensions and weight Design............................................................. For mounting in a 19” rack, height 1U Size ................................................................. 444 mm x 262 mm x 44 mm Weight.................................

  • Cronyx Qlink-3000/2E1, Qlink-3000 Multiplexing modem Copyright © 2003 -2005 Cronyx Engineering 5 Section 1. Introduction 1.1. Application Qlink-3000 – is a modem family for physical links, designed to operate over a single twisted pair. Models equipped with two data ports (/2E1 and /E1-ETV) include the multiplexing device and allow transmission of two independent data streams over a single twisted pair. Device structural diagram is presented on the figure: Port 0 E1 (G.703, G.704) Port 1 E1 (G.703, G.704) or Ethernet 10/100BaseT (Ethernet 10BaseT) Multi- plexer SHDSL transceiver SNMP port Console port Processor Maximum data tra

  • Cronyx Qlink-3000/2E1, Qlink-3000 Multiplexing modem Copyright © 2003 -2005 Cronyx Engineering 14 Ethernet port connector The RJ-45 female socket is used to connect the Ethernet port (10/100Base-T, IEEE 802.3 ) when operating using the remote bridge protocol: 1 - TX+ (output) 2 - TX (output) 3 - RX+ (input) 4 - not used 5 - not used 6 - RX (input) 7 - not used 8 - not used 1 8 Use direct cable for connection to the Ethernet switch. SNMP port connector An RJ-45 female socket is used for Ethernet port connection (10Base-T, IEEE 802.3 standard) for con

  • Cronyx Qlink-3000/2E1, Qlink-3000 Multiplexing modem Copyright © 2003 -2005 Cronyx Engineering 8 1.4. Technical specifications Link interface Link requirements .......................................... Unloaded twisted pair Link data rate.................................................. 208 kbit/s to 2320 kbit/s Link length ..................................................... Up to 10 km with a 0.6 mm wire strand diameter, up to 7.6 km with a 0.4 mm wire strand diameter Connector ....................................................... RJ type (female, 8 pins) Encoding.

  • Cronyx Qlink-3000/2E1, Qlink-3000 Multiplexing modem Copyright © 2003 -2005 Cronyx Engineering 16 Section 3. Operations 3.1. Indicators The front panel contains indicators, showing the status of the device. The list of indicators and their functions are specified below in the text. Qlink-3000/S-2E1-SNMP front panel TST SNMP 1 2 43 LINK CONSOLE ALARM 7 8 PWR PORT 0 PORT 1 65 Qlink-3000/S-E1/ETV-SNMP front panel TST SNMP 1 2 43 LINK CONSOLE ALARM 7 8 PWR PORT 0 PORT 1 9 1 0 6 5 1 2 1 1 1 Power indicator (PWR) The power indicator lights green when power supply is on. 2 BER tester indicator (TST) The indicator lights if the BER tester is switched on. The color determines the testing results: green - testing is perfo

  • Cronyx Qlink-3000/2E1, Qlink-3000 Multiplexing modem Copyright © 2003 -2005 Cronyx Engineering 20 10 Ethernet port state indicator (ETH-LINK) The ETH-LINK indicator does not light, if the Ethernet cable is not connected to the port, and lights green if the cable is connected to the Ethernet port (the indicator flashes during data reception and transmission). 11 Ethernet port error indicator (ETH-LOS) The ETH-LOS indicator lights red, if the Ethernet cable is not connected to the port, and flashes red during Ethernet bridge errors. 12 Ethernet port status indi

  • Cronyx Qlink-3000/2E1, Qlink-3000 Multiplexing modem Copyright © 2003 -2005 Cronyx Engineering 24 E1 port loop (Port 0 loop) Port 0 Port 1 Local device: E1 port loop (Port 0 loop) Remote device: normal operation Port 0 (E1) Port 1 When loop is enabled on the E1 port, the data received from the E1 port are turned back. The E1-LOC indicator blinks (single flashes); its color depends on the status: red - loss of signal (LOS) on the E1 receiver input, alarm indication signal (AIS) is received, loss of frame (LOF) of multiframe (LOMF) synchronization, green - no errors. E1 port tributary loop (Port 0 tributary loop) Local device: E1 port tributary loop (Port 0 tributary l

  • Cronyx Qlink-3000/2E1, Qlink-3000 Multiplexing modem Copyright © 2003 -2005 Cronyx Engineering 34 4.5. “Event counters” command Use “Event counters” command to get more detailed information about counters. Alive: 0 days, 18:04:39 since last counter clear Link counters CV = 0 - coding violations 0 - total code violations OOS = 52 - seconds without carrier Err = 0 - seconds with CRC error(s), LOSW defect(s) or BERT errors 0 - total CRC errors Event = 1 - seconds with jitter attenuator error(s) or S(H)DSL slip(s) 0 - total jitter attenuator errors 0 -

  • Cronyx Qlink-3000/2E1, Qlink-3000 Multiplexing modem Copyright © 2003 -2005 Cronyx Engineering 12 E1 port (Port 0) Ethernet port (Port 1) SNMP port Emergency alarm Console Link Grounding Power supply SNMP port Emergency alarm Console Link Grounding Power supply E1 port (Port 0) E1 port (Port 1) Front panel connector locations for Qlink-3000/S-2E1-SNMP model Power supply connector A standard mains connector is used to connect the AC power supply cable (for the “AC” model). The power supply cable is supplied with the device. To connect the DC power supply cable (for the “DC” model), the power supply connector

  • Qlink-3000 Multiplexing modem Copyright © 2003 -2005 Cronyx Engineering 28 Section 4. Control via the console port The front panel of the multiplexing modem is equipped with a DB9 (female) connector with an RS-232 interface for connecting the control terminal (console). The console may be used to view current device modes, port states, local and remote er

  • Cronyx Qlink-3000/2E1, Qlink-3000 Multiplexing modem Copyright © 2003 -2005 Cronyx Engineering 41 “Alarm input” command The “Alarm input” toggles the input emergency alarm contacts mode. The external sensor has two operating modes: “Normal” – closing-sensitive (default), and “Inverted” – opening-sensitive. In the “Normal” mode, when contact 3 connects to contact 7, the remote device goes into the emergency alarm status. (See section "Emergency alarm" for more details). “SNMP” menu The “SNMP” menu is designed for setting network IP addresses and SMTP protocol parameters: SNMP MAC address: 00-09-94-00-1a-49

  • Cronyx Qlink-3000/2E1, Qlink-3000 Multiplexing modem Copyright © 2003 -2005 Cronyx Engineering 26 3.5. Built-in BER tester The Qlink-3000 multiplexing modem has a built-in BER tester, which allows to perform error rate measurements in the SHDSL link. The measurements are performed using fixed or pseudo-random code according to the O.151 recommendation (the pattern length is 2 15 -1=32767 bits). The BER tester is controlled from the console (see the “Test” menu” section) or via an additional Ethernet port using the SNMP protocol. If remote control is allowed, then the BER tester may be controlled from a terminal connected to the console port of th

  • Cronyx Qlink-3000/2E1, Qlink-3000 Multiplexing modem Copyright © 2003 -2005 Cronyx Engineering 2 Contents Section 1. Introduction .......................................................5 1.1. Application .................................................................................................. 5 1.2. Model series ................................................................................................ 7 1.3. Order code................................................................................................... 7 1.4. Technical specifications ........

  • Qlink-3000 Multiplexing modem Copyright © 2003 -2005 Cronyx Engineering 22 3.3. Device responses to emergencies ecivedlacoL ecivedetomeR etatS syalerdnasrotacidnI ottuptuoSIA strop1E dnasrotacidnI syaler ottuptuoSIA strop1E rewocirtcelefossoL ylppus ,thgiltonodsrotacidnillA MRALA-yaleR ,der-COL-KNIL seod-MER-KNIL ,thgilton MRALA-yaleR strop1EllaoT knilLSDHSoN noitcennoc ,der-

Related Products and Documents (Modem):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Rotel RT-940AX Owner's manual rotel/rt-940ax-6AL.pdf 07 Feb 2024 7 1.54 Mb
2 X-Micro XMP3-128 Operation & user’s manual x-micro/xmp3-128-277.pdf 11 Jul 2023 19 0.73 Mb
3 First Data FD100 Quick setup manual first-data/fd100-97W.pdf 15 Nov 2023 7
4 Aquatic Serenity Series Owner's manual & installation manual aquatic/serenity-series-M2P.pdf 12 Jul 2023 32 0.73 Mb
5 Black Box KVTS317A Specifications black-box/kvts317a-8ZN.pdf 06 Jun 2023 2 0.27 Mb
6 Axis Q1755 Operation & user’s manual axis/q1755-A46.pdf 14 Apr 2023 66 4.13 Mb

Similar Resources:

  • VeriFone

    VX 680

    (2 pages)
    UPPSETNING Á Wi-Fi Vx680 Vx690 Til þess að posinn geti haft samskipti við netið, verður þú að slá inn WLAN / Wi-Fi upplýsingar í posanum. Fylgdu leiðbeiningum hér fyrir neðan. 1. Velja “Aðgerðir” svo “Fleiri” á skjánum á posanum 2. Velja “Net” neðst til vinstri. 3. Stimpla inn “Lykilorð söluaðila” 4. Velja “Wi …
  • Motorola/Arris

    SURFboard SB6183

    (2 pages)
    Quick Start GuideSURFboard® SB6183DOCSIS® 3.0 Cable ModemThe SB6183 Cable Modem provides high-speed Internet access on your home network via a single Ethernet connection. This quick start guide will help you install your SB6183 Cable Modem to get it up and running with your computer on your home network. To customize your network congurations and oth …
  • Zhone

    3920Plus

    (14 pages)
    13920-A2-GK47-10 February 2002COMSPHERE 3920Plus ModemsModel Number 3920-A2-xxxInstallation InstructionsDocument Number 3920-A2-GK47-10February 2002OverviewThe COMSPHERE Model 3920Plus modems are full-feature, high-speed leased modems, providing reliableasynchronous and synchronous operation over leased or dial-line networks with data rates as high as 33,600 …
  • Patton electronics

    1060

    (10 pages)
    USERMANUALMODEL 1060AC Powered, AsynchronousShort Range ModemSALES OFFICE(301) 975-1000TECHNICAL SUPPORT(301) 975-1007http://www.patton.comPart #07M1060-CDoc. #058011CRevised 11/3/97CERTIFIEDAn ISO-9001Certified CompanyDear Valued Customer,Thank you for purchasing Patton Electronics products! We doappreciate your business. I trust that you find this user …
  • U.S. Converters

    UCW4842

    (4 pages)
    Quick reference V1.2 www.usconverters.com 1 Copyrights © U.S. Converters LLC Quick reference sheet for WiFi to RS485/422 adapter UCW4842 Block Terminal Connector: RX-/B RX+/A TX- TX+ LED: Data: Red Status: Blue Switch: RS485 RS422 2 dBi dipole antenna Mini USB power port Power switch 4.5 - 24VDC power option Reset …
  • Hughes

    HN9000

    (10 pages)
    Guide To Returning Your Satellite Modem and Radio AssemblyModel: HN9000The HughesNet modem with power supply and radio must be returned to Hughes, in good condition, within 45 days of your service termination in order to receive the equipment refund. You are not required to return, and Hughes is not obligated to de-install or pay for the de-installation of …