Text of E-Tech 09 User Guide:

  • E-Tech 09, 2 664Y3400 54428195 EN: Base for relay FR: Base pour relais NL: Relaisvoet ES: Basa para relé IT: Base per relè DE: Relais-Sockel 54766015 EN: Control circuit “Siemens” FR: Disjoncteur “Siemens” NL: ON/OFF-schakelaar “Siemens” ES: Disyuntor “Siemens” IT: Interruttore ON/OFF “Siemens” DE: Siemens- Schutzschalter 54452082 EN: Relay “Siemens” [3TG] FR: Relais “Siemens” [3TG] NL: Relais [3TG] “Siemens” ES: Relé “Siemens” [3TG] IT: Relè “Siemens” [3TG] DE: Siemens-Relais [3TG] 544281

  • E-Tech 09, EN • 7 ENGLISHFRANCAISNEDERLANDSESPAÑOLITALIANODEUTSCH 664Y3400 TECHNICAL CHARACTERISTICS Model 09 15 22 28 36 Power 4.2 to 8.4 kW 7.2 to 14.4 kW 14.4 to 21.6 kW 21.6 to 28.8 kW 30 to 36 kW Nominal supply voltage 1 x 230 V or 3 x 400 V + N 1 x 230 V or 3 x 400 V + N 3 x 400 V + N 3 x 400 V + N 3 x 400 V + N Ohmic resitance of element 37,8 Ohm 22 Ohm 22 Ohm 22 Ohm 17,6 Ohm Heating element type 2 x 1.4 kW 2 x 2.4 kW 2 x 2.4 kW 2 x 2.4 kW 2 x 3 kW Number of elements 33566 Water capacity (Litres) 13 13 13 1

  • E-Tech 09, EN • 11 ENGLISHFRANCAISNEDERLANDSESPAÑOLITALIANODEUTSCH 664Y3400 TECHNICAL CHARACTERISTICS Electrical data of model 28 STAGE 1 STAGE 2 TOTAL POWER TERMINALS Tri phase 28.8 kW (*) Terminals 3 and 4 shunted Terminal 2 L1 (A) 20.8 20.8 41.6 Terminals 5 and 6 shunted Terminal 3 L2 (A) 20.8 20.8 41.6 Relay K5 activated Terminal 5 L3 (A) 20.8 20.8 41.6 Terminal 1 N (A) 0 0 0 Power (kW) 14.4 14.4 28.8 1 N 2 L1 3 L2 4 5 L3 6 Tri phase 26.4 kW (***) Terminals 3 and 4 shunted Terminal 2 L1 (A) 20.8 20.8 41.6 Relay K5 activated Terminal 3 L

  • E-Tech 09, EN • 6 ENGLISHFRANCAISNEDERLANDSESPAÑOLITALIANODEUTSCH 664Y3400 1 2 3 4 6 7 85 USER DATA All user controls are situated on the front panel of the boiler, there are no user controls inside the boiler casing. The following instructions assume that the boiler has been commissioned, and that the system is filled with water and has been fully vented. SETTING UP • Before switching on any electrical supplies to the boiler ensure that the combined temperature and pressure gauge reads at least 1 bar and the control thermostat is set to the desired temperature. • If an internal time

  • E-Tech 09, EN • 4 ENGLISHFRANCAISNEDERLANDSESPAÑOLITALIANODEUTSCH 664Y3400 DESCRIPTION OF THE SPECIFICATIONS: This wall hung electric boiler is available in 5 models: • Models 09 and 15 are supplied with 400 Volt triphase + N, convertible to 230 V single phase. • Models 22, 28 and 36 are only supplied with 400 V triphase + N. The maximum power can be adjusted for all models by acting on the terminals bridges. The maximum power can be adjusted for all models by acting on the terminals bridges. - Model 09: Adjustable power from 4.2 to 8.4 kW - Model 15: Adjustable power from 7.2 to 14.4 kW - Model 22: Adjustable power from 14.4 to 21.6 kW - Model 28: Adjus

  • E-Tech 09, EN • 8 ENGLISHFRANCAISNEDERLANDSESPAÑOLITALIANODEUTSCH 664Y3400 TECHNICAL CHARACTERISTICS Electrical data of model 09 STAGE 1 STAGE 2 TOTAL POWER TERMINALS Tri phase 8.4 kW (*) Terminals 1 and 2 shunted Terminal 3 L1 (A) 6 6 12 Terminals 5 and 6 shunted Terminal 4 L2 (A) 12 0 12 Relay K4 activated Terminal 5 L3 (A) 6 6 12 Terminal 1 N (A) 6 6 0 Power (kW) 5.6 2.8 8.4 1 N 23 L1 4 L2 5 L3 6 Tri phase 7 kW (***) Terminals 1 and 2 shunted Terminal 3 L1 (A) 6 6 12 Relay K4 activated Terminal 4 L2 (A) 12 0 12 Terminal 5 L3 (A) 6 0 6 Terminal 1 N (A) 6 6 6 Power (kW) 5.6 1.4 7 1 N 23 L1 4 L2 5

  • E-Tech 09, EN • 16 ENGLISHFRANCAISNEDERLANDSESPAÑOLITALIANODEUTSCH 664Y3400 INSTALLATION 39 38 37 36 35 34 33 32 31 29 28 27 26 25 24 23 22 21 19 1 8 17 16 15 14 13 12 11 9 8 7 6 5 4 3 2 1 39 38 37 36 35 34 33 32 31 29 28 27 26 25 24 23 22 21 19 1 8 17 16 15 14 13 12 11 9 8 7 6 5 4 3 2 1 HEATING CONNECTION + DHW : “S” PLAN HEATING CONNECTION + DHW : “Y” PLAN Limiting the maximum adjustable temperature 60 - 85°C 60 - 85°C Limiting the maximum adjustable temperature

  • E-Tech 09, EN • 25 ENGLISHFRANCAISNEDERLANDSESPAÑOLITALIANODEUTSCH 664Y3400 HONEYWELL SUNDIAL WIRING DIAGRAMS Note: Illustrated model = 28 kW - 36 kW Tri Phase Note: All bold numbers indicate a DIN rail terminal connection CYLINDER STAT HTG HW ON N L 1 4 3 2 5 6 T6306B ROOM STAT 2 1 3 7 8 9 10 Honeywell Sundial Wiring Centre `Y ` Plan Note: Earth wires not shown for clarity During installation the earth wires from each component connect to terminal 3 in the wiring centre E bk- black br- brown r-red w-white y- yellow o

  • E-Tech 09, EN • 26 ENGLISHFRANCAISNEDERLANDSESPAÑOLITALIANODEUTSCH 664Y3400 COMMISSIONING - WATER 1. The system must be thoroughly cleansed prior to connection of the boiler. The system water should be treated to prevent general corrosion and deposition of scale or sludge in the boiler, please refer to BS7593. If installing the boiler onto an existing system, ACV recommend that an approved system cleaner is used. 2. Fill and pressurise the boiler and system to 1.5 bar, making sure to vent the boiler via the automatic air vent on top of the boiler. Note that the black dust cap on the air vent should be left loose to allow the auto vent to fu

  • E-Tech 09, EN • 12 ENGLISHFRANCAISNEDERLANDSESPAÑOLITALIANODEUTSCH 664Y3400 TECHNICAL CHARACTERISTICS Electrical data of model 36 STAGE 1 STAGE 2 TOTAL POWER TERMINALS Tri phase 36 kW (*) Terminals 3 and 4 shunted Terminal 2 L1 (A) 26 26 52 Terminals 5 and 6 shunted Terminal 3 L2 (A) 26 26 52 Relay K5 activated Terminal 5 L3 (A) 26 26 52 Terminal 1 N (A) 0 0 0 Power (kW) 18 18 36 1 N 2 L1 3 L2 4 5 L3 6 Tri phase 34 kW (***) Terminals 3 and 4 shunted Terminal 2 L1 (A) 26 26 52 Rel

  • E-Tech 09, EN • 20 ENGLISHFRANCAISNEDERLANDSESPAÑOLITALIANODEUTSCH 664Y3400 INSTALLATION WIRING DIAGRAMS / MODELS : 28 - 36 L1 1 2 br br br bk N 3 4 b bbb b b 5 6 8 7 t p b b b br or g bb rbk 3 amp MCB C 2 1 r C 1 2 or 9 10 11 12 y yy 13 14 y yy y y pk pk b pk t or or or or r r gg gpk pk pk r pk b b bw b b w g g or b b g 17 19 18 20 M 2.1. 2.2. 1.1. 1.2. 21 22 t w r ABC D E F GHJ JL I K2 K4 bw 23 24 w pk K5 K3 y g b 15 16 24 21 32 31 14 11 O P Q b Blue bk Black br Brown g Grey or Orange pk Pink r Red v Violet w White y Yellow A ON/OFF switch B Manual reset high limit thermostat C Wa

  • E-Tech 09, EN • 17 ENGLISHFRANCAISNEDERLANDSESPAÑOLITALIANODEUTSCH 664Y3400 INSTALLATION • This appliance must be permanently connected to fixed wiring and must be earthed. • The wiring must be carried out by a competent person and in accordance with the current IEE Wiring Regulations. • Isolation device must be provided with a minimum contact clearance of 3 mm. • The MCB must be readily accessible and adjacent to the appliance. L3 L2 NL1 5 L3 3 4 L1 L2 1 2 N 6 Power supply 3 x 400 V + Neutral Power supply 3 x 400 V + Neutral + Safety contactor The safety contactor is not supplied by ACV 7 8 7 8 5 6 5 6 3 4 3 4 1 2 1 2 L3 L2

  • EN • 24 ENGLISHFRANCAISNEDERLANDSESPAÑOLITALIANODEUTSCH 664Y3400 HONEYWELL SUNDIAL WIRING DIAGRAMS Note: Illustrated model = 28 kW - 36 kW Tri Phase Note: All bold numbers indicate a DIN rail terminal connection CYLINDER STAT HTG HW N L 1 4 3 2 5 6 T6306B ROOM STAT 2 1 3 V4043H HTG ZONE VALVE MOTOR 7 8 9 10 V4043H DHW ZONE VALVE MOT

  • EN • 14 ENGLISHFRANCAISNEDERLANDSESPAÑOLITALIANODEUTSCH 664Y3400 INSTALLATION Panel removal and access to hydraulic connections 1. Undo screws. 2. Tilt panel towards you and lift clear remove the top cover. 3. Loosen screws of the control panel. 4. Turn up the control panel. 5. Block the control panel with the screw. DISASSEMBLING A C 1 2 2 3 B 4 5

  • E-Tech 09, 8 664Y3400 N° EN FR NL ES IT DE A01 Side panel Latérale Zijkanten Lateral Pannello laterale Seitenteil A02 Front panel Face avant Frontstuk Parte delantera Mantello anteriore Vorderteil A03 Top cover Couvercle supérieur Bovenkap Tapa superior Mantello superiore Obere Abdeckung A04 Rear panel Panneau arrière Achterpaneel Panel posterior Pannello posteriore Hintere Blende A05 Control panel [ABS] Tableau [ABS] Paneel [ABS] Panel [ABS] Pannello [ABS] ABS-Tafel A06 Wall mounting Fixation murale Wandbevestiging Fijación mural Staffa murale Wandhalterung A07 Body heating Corps de chauffe Ketellichaam Cuerpo de calefacción Corpo caldaia Kesse

  • EN • 22 ENGLISHFRANCAISNEDERLANDSESPAÑOLITALIANODEUTSCH 664Y3400 INSTALLATION POWER WIRING / MODEL : 22 3 x b 3 x or 2 x bk 1 x bk 2 x r 1 x r K2 or r bk b or r bk b K3 Or r Bk b or r bk b K4 or r bk b or r bk b Type 22 21,6 kW 19,2 kW 16,8 kW 14,4 kW TRI PHASE 1 N 2 L1 3 L2 4 5 L3 6 1 N 2 L1 3 L2 4 5 L3 6 1 N 2 L1 3 L2 4 5 L3 6 1 N 2 L1 3 L2 4 5 L3 6 Current not balanced Current not balance

  • E-Tech 09, EN • 21 ENGLISHFRANCAISNEDERLANDSESPAÑOLITALIANODEUTSCH 664Y3400 INSTALLATION POWER WIRING / MODELS : 09 - 15 K2 K3 K4 3 x b 3 x b 2 x or 2 x bk r r r bk b b b b b b bk or or r r bk b b b b b b bk or or r Type 9 8,4 kW 7 kW 5,6 kW 4,2 kW Type 15 14,4 kW 12 kW 9,6 kW 7,2 kW TRI PHASE 1 N 23 L1 4 L2 5 L3 6 1 N 23 L1 4 L2 5 L3 6 1 N 23 L1 4 L2 5 L3 6 1 N 23 L1 4 L2 5 L3 6 Current not balanced Current not balanced SINGLE PHASE 1 N 23 L 456 1 N 23 L 456 1 N 23 L 456 1 N 23 L 456 21 22 21 22 21 22 21 22 21 22 21 22 21 22 21 22

  • E-Tech 09, EN • 23 ENGLISHFRANCAISNEDERLANDSESPAÑOLITALIANODEUTSCH 664Y3400 INSTALLATION POWER WIRING / MODELS : 28 - 36 4 x b 4 x or 3 x bk 1 x bk 3 x r 1 x r K2 or r bk b or r bk b K3 Or r Bk b or r bk b K5 or r bk b or r bk b K4 or r bk b or r bk b Type 28 28,8 kW 26,4 kW 24 kW 21,6 kW Type 36 36 kW 33 kW 30 kW 27 kW TRI PHASE 1 N 2 L1 3 L2 4 5 L3 6 1 N 2 L1 3 L2 4 5 L3 6 1 N 2 L1 3 L2 4 5 L3 6 1 N 2 L1 3 L2 4 5 L3 6 Current not balanced Current not balanced 23 24 23 24 23 24 23 24 23 24 23 24 23 24 23 24

  • E-Tech 09, EN • 2 ENGLISHFRANCAISNEDERLANDSESPAÑOLITALIANODEUTSCH 664Y3400 INDEX WARNINGS 3 Who should read these instructions 3 Symbols 3 Recommendations 3 Applicable standards 3 Importants notes 3 Manual handling instructions 3 Removing the boiler from the packaging 3 INTRODUCTION 4 Description of the specifications 4 Lining 4 Heating body 4 Heating elements 4 Equipment 4 Connection 4 Dual stage thermostat 4 Certification 4 Legend 4 INSTRUCTIONS 6 User data 6 Setting up 6 Optional internal timeclock 6 Pressure in the heating system 6 TECHNICAL CH

  • E-Tech 09, 6 664Y3400 54428183 EN: Heating element 2 x 1,4 kW FR: Elément chauffant 2 x 1,4 kW NL: Verwarmingselement 2 x 1,4 kW ES: Elemento calefactor 2 x 1,4 kW IT: Resistenza elettrica 2 x 1,4 kW DE: Heizelement 2 x 1,4 kW 54428182 EN: Heating element 2 x 2,4 kW FR: Elément chauffant 2 x 2,4 kW NL: Verwarmingselement 2 x 2,4 kW ES: Elemento calefactor 2 x 2,4 kW IT: Resistenza elettrica 2 x 2,4 kW DE: Heizelement 2 x 2,4 kW 5476D004 EN: Heating element 2 x 3 kW FR: Elément chauffant 2 x 3 kW NL: Verwarmingselement 2 x 3 kW ES: Elemento celefactor 2 x 3 kW IT: Resistenza elettrica 2 x 3 kW DE: Heizelem

  • E-Tech 09, EN • 9 ENGLISHFRANCAISNEDERLANDSESPAÑOLITALIANODEUTSCH 664Y3400 Electrical data of model 15 STAGE 1 STAGE 2 TOTAL POWER TERMINALS TECHNICAL CHARACTERISTICS Tri phase 14.4 kW (*) Terminals 1 and 2 shunted Terminal 3 L1 (A) 10.4 10.4 20.8 Terminals 5 and 6 shunted Terminal 4 L2 (A) 20.8 0 20.8 Relay K4 activated Terminal 5 L3 (A) 10.4 10.4 20.8 Terminal 1 N (A) 10.4 10.4 0 Power (kW) 9.6 4.8 14.4 1 N 23 L1 4 L2 5 L3 6 Tri phase 12 kW (***) Terminals 1 and 2 shunted Terminal 3 L1 (A) 10.4 10.4 20.8 Relay K4 activated Terminal 4 L2 (A) 20.8 0 20.8 Terminal 5 L3 (A) 10.4 0 10.4 Terminal 1 N

  • EN • 10 ENGLISHFRANCAISNEDERLANDSESPAÑOLITALIANODEUTSCH 664Y3400 TECHNICAL CHARACTERISTICS Electrical data of model 22 STAGE 1 STAGE 2 TOTAL POWER TERMINALS Tri phase 21.6 kW (*) Terminals 3 and 4 shunted Terminal 2 L1 (A) 20.8 10.4 31.2 Terminals 5 and 6 shunted Terminal 3 L2 (A) 20.8 10.4 31.2 Relay K4 activated Terminal 5 L3 (A) 20.8 10.4 31.2 Terminal 1 N

  • E-Tech 09, EN • 5 ENGLISHFRANCAISNEDERLANDSESPAÑOLITALIANODEUTSCH 664Y3400 INTRODUCTION Top cover Rear panel Water pressure switch Expansion vessel connection Direct ESC kit connection (in option) Heating return Automatic air vent Expansion vessel Valve of expansion vessel Heating out Manual reset high limit pressure gauge Expansion vessel connection Circulating pump Heating elements Heating body Pressure safety valve Cable gland Hand side panel Minimum thermostat (only with direct DHW kit) Control panel Brass pocket

  • E-Tech 09, EN • 15 ENGLISHFRANCAISNEDERLANDSESPAÑOLITALIANODEUTSCH 664Y3400 INSTALLATION 39 38 37 36 35 34 33 32 31 29 28 27 26 25 24 23 22 21 19 1 8 17 16 15 14 13 12 11 9 8 7 6 5 4 3 2 1 39 38 37 36 35 34 33 32 31 29 28 27 26 25 24 23 22 21 19 1 8 17 16 15 14 13 12 11 9 8 7 6 5 4 3 2 1 39 38 37 36 35 34 33 32 31 29 28 27 26 25 24 23 22 21 19 1 8 17 16 15 14 13 12 11 9 8 7 6 5 4 3 2 1 39 38 37 36 35 34 33 32 31 29 28 27 26 25 24 23 22 21 19 1 8 17 16 15 14 13 12 11 9 8 7 6 5 4 3 2 1 20 20 19 19 17 18 17 18 15 16 15 16 13 14 13 14 11 12 11 12 HEATING CONNECTION HEATING CONNECTION + DHW (2 Circulatings pumps) HEATING CONNECTION + DHW (Circul

Related Products and Documents (Boiler):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 New Holland 790 Specifications new-holland/790-TZE.pdf 05 Jun 2023 2
2 Philips Pronto TSU9600 Specification sheet philips/pronto-tsu9600-48A.pdf 18 Feb 2023 2 0.46 Mb
3 Telex XCP-ADAM-MC Update telex/xcp-adam-mc-83W.pdf 18 Nov 2023 2 0.13 Mb
4 NETGEAR GSM7312 - ProSafe Layer 3 Managed Gigabit Switch Operation & user’s manual netgear/gsm7312-prosafe-layer-3-managed-gigabit-switch-GO6.pdf 15 Apr 2023 268
5 Garden Oasis D71 M80116 Owner's manual garden-oasis/d71-m80116-586.pdf 19 Sep 2022 4 0.74 Mb
6 Kenmore 415.16645900 Use and care manual kenmore/415-16645900-8S5.pdf 06 Feb 2024 32

Similar Resources:

  • Viessmann

    Vitolig 200

    (65 pages)
    File in:Vitotec technical guide folder, register4VITOLIGSolid fuel boiler5 to 40 kWVitolig300Steel boiler for burning wood pelletsVitolig200Steel boiler for burning wood briquettes and logs up to 50cm longVitolig100Steel boiler with natural draught and water−cooled grate for burning logs up to 33 cm longTechnical guideVitolig200 Vitolig� …
  • Viessmann

    VITOCELL 100-U

    (24 pages)
    Installation instructionsfor contractorsVIESMANNVitocell 100-UType CVUBDual mode DHW cylinder with Solar-Set Vitocell 100-WType CVUB/CVUB-ADual mode DHW cylinder with Solar-SetVITOCELL 100-UVITOCELL 100-W5838620 GB 2/2019Dispose after installation. …
  • Aerco

    GF-123

    (108 pages)
    Printed in U.S.A. REVISED 9/21/09 Instruction No.AERCO INTERNATIONAL, Inc., Northvale, New Jersey, 07647 USA GF-123 Installation, Operation & Maintenance Instructions Benchmark 2.0 Low NOx Natural Gas Fired Boiler System Condensing, Modulating Forced Draft, Hot Water Boiler 2,000,000 BTU/H Input …
  • Keston

    C40

    (4 pages)
    Users Instructions For C40,C40P, C55 and C55P ModelsThe Gas Safety (Installation And Use) Regulations: 1996 (as amended) impose certain statutoryobligations on gas users. Further information regarding these regulations can be obtained from yourGas Supplier.All gas appliances must be installed by competent persons by law in accordance with theseregulations. M …
  • ECR International

    Olsen OQ95M-200

    (52 pages)
    OQ95M-200GAS-FIRED DIRECT VENTMODULATING HOT WATER BOILERINSTALLATION, OPER ATION & MAINTENANCE MANUALAn ISO 9001-2008 Certied CompanyManufactured by:ECR International, Inc.2201 Dwyer Avenue, Utica NY 13501web site: www.ecrinternational.comP/N# 240006103B, Rev. E [02/2014]ModelOQ95M-200 …
  • BRÖTJE

    RGT B

    (168 pages)
    DEMontageanleitungRGT B / RGTK BRGTF B / RGTKF BGBInstallation instructionsRGT B / RGTK BRGTF B / RGTKF BFRInstructions de montageRGT B / RGTK BRGTF B / RGTKF BITIstruzioni di montaggioRGT B / RGTK BRGTF B / RGTKF BPLInstrukcja montażuRGT B / RGTK BRGTF B / RGTKF BDKMonteringsvejledningRGT B / RGTK BRGTF B / RGTKF BNLMontagehandleidingRGT B / RGTK BRGTF B / …

Comments, Questions and Opinions: