Manualios.com

Emerson Rosemount 5708 Quick Start Manual

Emerson Rosemount 5708 Manual Online:

3.9, 612 votes
Emerson Rosemount 5708 User Manual
Emerson Rosemount 5708 User Guide
Emerson Rosemount 5708 Online Manual

Text of Emerson Rosemount 5708 User Guide:

  • Emerson Rosemount 5708, Quick Start Guide 13 July 2017 6. Connect the cable wires according to the wiring diagram. See page 14 for different connection methods. 7. Connect the external ground terminal. The Rosemount 5708 must be grounded electrostatically.  For internal grounding, use the power cable ground.  For external grounding, use the earth potential equalization of the plant. - + RS-485/Modbus RTU communication terminals 4-20 mA communication terminals - + Feed in power supply 20-32 Vdc + - Note When connecting the last Rosemount 5708 in the chain, a 120 Ω resistor must be connected as well. Check polarity of the power entity before connecting the device. External ground screw Note An inte

  • Emerson Rosemount 5708, Quick Start Guide 7 July 2017  Keep necessary distance from side wall.  Keep necessary distance from filling points.  Make sure there is no obstacle below the device.  In the case of standpipe mounting, assemble and position the Rosemount 5708 at a height that leaves at least 0.4 in. (10 mm) below the standpipe for the antenna end to protrude. Minimum 24 in. (600 mm) Minimum 24 in. (600 mm) Minimum 0.4 in. (10 mm) for standpipe mounting 5708_QSG_00825-0100-4570_RevCB.fm Page 7 Tuesday, July 4, 2017 9:38 PM

  • Emerson Rosemount 5708, Quick Start Guide 33 July 2017 8.8 EAC IM Intrinsic Safety by TR CU 012/2011 Markings: 1Ex ib [ia] IIB T4 Gb X (-40 < Tamb < 85 °C) Ex ib [ia] IIIC T110 °C Da/Db X (-40 < Tamb < 85 °C) Special Conditions for Safe Use (X): 1. Level meter should be installed and operated in such a way that no danger of ignition due to electrostatic discharge. 2. The instructions specified in the manual, eliminates the risk of corrosion and / or mechanical action. 3. When the level meter, which provides separation of the head in areas requiring protection level equipment Da, the degree necessary to provide protection for at le

  • Emerson Rosemount 5708, Global Headquarters Emerson Automation Solutions 6021 Innovation Blvd. Shakopee, MN 55379, USA +1 800 999 9307 or +1 952 906 8888 +1 952 949 7001 [email protected] North America Regional Office Emerson Automation Solutions 8200 Market Blvd. Chanhassen, MN 55317, USA +1 800 999 9307 or +1 952 906 8888 +1 952 949 7001 [email protected] Latin America Regional Office Emerson Automation Solutions 1300 Concord Terrace, Suite 400 Sunrise, FL 33323, USA +1 954 846 5030 +1 954 846 5121 [email protected] Linkedin.

  • Emerson Rosemount 5708, July 2017 24 Quick Start Guide 3. Set the correct connection type, polling address, and serial port. Select Connect. After selecting the Connect button, the software automatically connects and downloads the parameters from the Rosemount 5708. 4. After the connection has been made, Configuration Wizard appears: a. Step 1/4: Set up general information and vessel dimensions. b. Step 2/4: Set up device position. c. Step 3/4: Set up filling points. d. Step 4/4: Set up full and empty calibration. Select Fin

  • Emerson Rosemount 5708, Quick Start Guide 31 July 2017 8.5 International I7 IECEx Intrinsic Safety Certificate: IECEx BVS 15.0042X Standards: IEC 60079-0: 2011, IEC 60079-11: 2011 Markings: Ex ib [ia] IIB T4 Gb (-40 °C < Ta < +85 °C) Ex ib [ia] IIIC T110°C Da/Db (-40 °C < Ta < +85 °C) Special Condition for Safe Use (X): 1. Dust application: The installation of the 3D-Solids Scanner or of the Antenna Unit of models providing head separation in the wall to areas requiring EPL Da equipment shall provide a degree of protection IP6X according to IEC 60529 and shall be carried out in such a way, that all

  • Emerson Rosemount 5708, Quick Start Guide 27 July 2017 7.0 Rosemount 5708S in a system 7.1 System components  Multiple units of Rosemount 5708S  Rosemount System Controller 7.2 Physical mounting 1. Install the devices as written in “Physical mounting” on page 8. 2. Repeat installation steps until all are installed. 7.3 Wiring Power A single 24 Vdc power supply is for all devices within the system. + - PS OUT Display + - PS OUT Display ++-- PS IN 4...20mA + - RS-485 PS IN 4...20mA RS-485 ++-- + - ++-- PS IN 4...20mA + - RS-485 ++-- PS IN 4...20mA + - RS-485 Convert 120 Ω resistor PLC / DCS / D

  • Emerson Rosemount 5708, July 2017 16 Quick Start Guide 1. Connect power and open the front cover. A self-test will start and run for about 30 seconds the display remains blank during this time. 2. After initialization, the version screen appears. According to the factory default settings, after power initiation or scanner restart, a screen prompts for configuration. In the main menu, select Basic Settings. 3. Use the / keys to switch between the options. Press to select and continue with the settings or to exit to the main screen. 4. When the startup process is complete,

  • July 2017 6 Quick Start Guide Figure 2. Full and Empty Calibration in Rectangular and Cylindrical Vessels 2.5 Application process 2.6 Mounting location  Mount Rosemount 5708 perpendicular to the ground. Full calibration: ft m Empty calibration: ft m Maximum filling rate: lbs/hour tons/hour Maximum emptying rate: lbs/hour tons/hour Total capacity when vessel is ful

  • Emerson Rosemount 5708, Quick Start Guide 23 July 2017 5.0 Configuration using Rosemount 3DVision 5.1 Installing the Rosemount 3DVision software The software is comprised of two components: a server and a client. For initial configuration, it is recommended to install both the server and the client on the same computer. However, it is possible to install the Rosemount 3DVision Server and Client on separate computers and connect to them accordingly. 1. Insert the flash drive into the USB port. 2. Select Install Rosemount 3DVision and follow the on-screen instructions. If the

  • July 2017 22 Quick Start Guide 3. Select Map False Echoes for automatically mapping all the false echoes up to a certain distance. Or select Reset Mapping for deleting the stored mapped false echoes from the memory of the scanner. Use the key to go down the list. Press to continue. a. If Map False Echoes is selected, set the distance from the top of the antenna assembly to

  • Emerson Rosemount 5708, July 2017 26 Quick Start Guide 6.0 Post installation procedures 1. Perform hand measurement to the material. 2. Compare data with the result of distance measurement performed by the Rosemount 5708: a. Reference point for measurements and comparisons is the top part of the antenna assembly. b. Test the device while silo is idle. c. Measure as close to the Rosemount 5708 as possible. d. In some models, the device has minimum and maximum values for distance. Check if the hand dip is between these measurement. 3. Coordinate filling and emptying processes. a. Follow the Rosemount 5708 measurements during the process. b. Check and

  • Emerson Rosemount 5708, July 2017 18 Quick Start Guide 3. Set the distance units, either meters (m) or feet (ft). 4. Set Vessel Height from the vessel bottom edge to the vessel top edge. Use the key to switch between the two digits. Use the key to modify the value. 5. Select the vessel shape, either Cylindrical or Rectangular. Use the / keys to switch between the options. Press to continue. a. If Cylindrical is selected, set vessel diameter. Use the key to switch between the two digits. Use the key to modify the value. Press to continue. b. Set Scanner Height from the bottom edge

  • July 2017 8 Quick Start Guide 3.0 Physical mounting Step 1: Check power and cables 1. Check the 24 Vdc with a voltmeter. 2. Check the resistance of the data communication lines. 3. Verify 60 Ω of resistance when connecting the 120 Ω resistors at both ends. Step 2: Install the mounting plate 1. Verify the O-rings on the neck tube are in place. 2. Remove the nut

  • Emerson Rosemount 5708, July 2017 34 Quick Start Guide 8.10 Korea IP KTL Intrinsic Safety Certificate: 15-KA4BO-0298X - ex Standards: IEC 60079-0: 2011, IEC 60079-11: 2011 Markings: Ex ib [ia] IIB T4 Gb, Ex ib [ia] IIIC T110C Da/Db For detailed information on configuring the Rosemount 5708 and Rosemount System Controller, refer to the Rosemount 5708 Reference Manual. 5708_QSG_00825-0100-4570_RevCB.fm Page 34 Tuesday, July 4, 2017 9:38 PM

  • Emerson Rosemount 5708, Quick Start Guide 11 July 2017 6. Tighten the front screw. 7. Remount the cable clamp. 8. Gently connect the antenna cable connector. Make sure the latch is clicked and locking the connector. Hex key (4 mm) Open wrench (13 mm) 5708_QSG_00825-0100-4570_RevCB.fm Page 11 Tuesday, July 4, 2017 9:38 PM

  • Emerson Rosemount 5708, Quick Start Guide 19 July 2017 6. If Rectangular is selected, set vessel width first (dimension on the x-axis). a. Use the key to switch between the two digits. Use the key to modify the value. Press to continue. b. Set Vessel Length (dimension on the y-axis). Use the key to switch between the two digits. Use the key to modify the value. Press to continue. c. Set Scanner Height from the bottom edge of the vessel to the scanner’s mounting plate (point above the antenna). Use the key to switch between the two digits. Use the key to modify the value. Press to continue. d. Set the scanner’s distance from the x-axis, see Figure 1 on page 5

  • Emerson Rosemount 5708, July 2017 20 Quick Start Guide Advanced Settings configuration After configuring the Basic Settings, perform Advanced Settings configuration. 1. From the main screen, press the key to enter the main menu. 2. In the main menu, scroll down to Advanced Settings, using the key. Press to switch to the Advanced Settings configuration screen. 3. Set the distance from the mounting plate (top of the scanner’s antenna) to the Full calibration point/100% level point. Use the key to switch between the two digits. Use the key to m

  • Emerson Rosemount 5708, July 2017 12 Quick Start Guide Step 5: Wire the Rosemount 5708 1. Verify the power supply is disconnected. 2. Loosen the compression nut of the cable gland entry. 3. Insert the cable into the head. 4. Remove approximately 4 in. (100 mm) of the cable mantle and strip approximately 0.4 in. (10 mm) off the edge of each conductor. 5. Loosen the terminal block screws located inside the head. 4 in. (100 mm) 0.4 in. (10 5708_QSG_00825-0100-4570_RevCB.fm Page 12 Tuesday, July 4, 2017 9:38 PM

More Instructions:

DOWNLOAD

Related Products and Documents (Scanner):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Ibanez PU3 Owner's manual ibanez/pu3-1OG.pdf 14 May 2023 4
2 Whirlpool EV090F Use & care manual whirlpool/ev090f-C5Y.pdf 20 Aug 2022 12
3 Kenmore 415.23665310 Use & care manual kenmore/415-23665310-5AE.pdf 10 Mar 2024 64
4 Formax 6206 Series Operator's manual formax/6206-series-84G.pdf 22 Feb 2024 85
5 Tech Craft MC4832B Assembly instructions tech-craft/mc4832b-1D8.pdf 21 Oct 2023 5 4.03 Mb
6 Garmin 60C Owner's manual garmin/60c-3X9.pdf 09 Feb 2023 96 2.15 Mb

Similar Resources:

  • Ricoh

    Aficio SP C242SF

    (4 pages)
    on-demandcapableaffordableRicoh Aficio SP C242SFDesktop Color Laser MFPVersatile performance in vivid colorNEVER GET CAUGHT LOOKING BACKC RE::::The Future of WSG&T:Taking Olde, Making Them News...worthyThe synergy of Olde and WSG&T has stood as a powerful partnership for decades, having earned success for both investors and consumers alike. Up to …
  • Epson

    GT-20000

    (4 pages)
    Document ScannersProductivity | Reliability | VersatilityLINE GUIDE* Optional ADF on GT-20000. ** Dual CCD f or one pass duplexing f or GT-S 50 and GT-S 80. 1200 dpi, Letter size, black-and-white, Speed Priority Scanning mode, portrait, simplex. 2300 dpi, A4 size, black-and-white, portrait, simplex. 3200 dpi, A4 size, black-and-white, Speed Pr …
  • Colortrac

    SmartLF Ci 40

    (2 pages)
    Assembly Instructions for SmartLF Ci 40 Floor Stand DOCUMENT P/N:POO5501PAS 172 Colortrac Ltd © 2008 � …
  • Minolta

    QUICKSCAN35

    (32 pages)
    1Thank you for purchasing the Minolta QuickScan 35. The QuickScan 35 enables you to scan bothnegative and positive, color and monochrome (black & white) 35mm film using the Macintosh. The main features of the QuickScan 35 are as follows:• High-speed scanning with 3-line sensors• High-quality images with a maximum of 2820 dpi• Easy, versatile softwa …
  • Canon

    imageFormula DR-C225

    (116 pages)
    1Chapter 1 IntroductionChapter 2 Important Safety InstructionsChapter 3 Installing the SoftwareChapter 4 Connecting the ScannerChapter 5 Placing DocumentsChapter 6 Scanning with CaptureOnTouchChapter 7 Setting the Scanner DriverChapter 8 Special ScanningChapter 9 Regular MaintenanceChapter 10 Replacing Consumable PartsChapter 11 Uninstalling the SoftwareChap …
  • Serialio

    Scanfob 4000n

    (2 pages)
    SCANFOB® 4000n Quick Start Guide 715 Di scovery Blvd. Ste 510 Ceda r Park, TX 78613 Tel: (512) 994-3630 Fax: (866) 546-4523 For sales inquiries: sa les @s eria l io.com For technical support: support@s eria li o.com Bluetooth Mode Bluetooth-SPP (Serial Port Profile - SSP) Bluetooth - HID (Huma n Interface Device – SSP) Defaults …

Comments, Questions and Opinions: