Manualios.com

INSYS MLR 3G 2.0 Manual 

INSYS MLR 3G 2.0 Manual Online:

4.25, 1789 votes
INSYS MLR 3G 2.0 User Manual
INSYS MLR 3G 2.0 User Guide
INSYS MLR 3G 2.0 Online Manual

Text of INSYS MLR 3G 2.0 User Guide:

  • INSYS MLR 3G 2.0, MLR 3G 2.0 Functions 10.1.2 Setting IP Addresses It must be possible to access the MLR 3G 2.0 in the LAN under a certain IP address. You must assign a static IP address for this. A virtual network address can be assigned to the local network. Devices in the local net- work can then be addresses with the virtual address via WAN. The MLR 3G 2.0 replaces the network portion of the virtual IP address with the network portion of the local net- work and forwards the packet to the destination. Configuration with the web interface In order to configure a stati

  • INSYS MLR 3G 2.0, Function Overview MLR 3G 2.0 6 Function Overview The MLR 3G 2.0 provides you with the following functions:  Configuration via web interface All functions of the MLR 3G 2.0 can be configured and set via a web inter- face. The access to the web interface is protected with a user name and password query. The TCP port which is used to access the web interface can be set freely.  Serial Ethernet gateway The MLR 3G 2.0 can output arriving data from a certain network port at the serial interface. Also, data arriving at the serial interface are sent to an IP remote terminal. Together with the INSYS VCom driver, the serial Ethernet gateway enables

  • INSYS MLR 3G 2.0, Contents 1 Safety .................................................................................................................. 7 1.1 Usage According to the Regulations ..................................................................................7 1.2 Permissible Technical Limits...............................................................................................8 1.3 Defects Liability Terms .......................................................................................................8 1.4 Marking of Warnings and Notes......................................................................

  • INSYS MLR 3G 2.0, Licenses MLR 3G 2.0 14 Licenses The software technologies and programs of the firmware used in the MLR 3G 2.0 are partly bound to the following licenses. The source code of the firmware components of the MLR 3G 2.0 which are bound to these licenses may be obtained from INSYS MICROELECTRONICS on request. 14.1 GNU GENERAL PUBLIC LICENSE Version 2, June 1991 Copyright (C) 1989, 1991 Free Software Foundation, Inc. 51 Franklin Street, Fifth Floor, Boston, MA 02110-1301, USA Everyone is permitted to copy and distribute verbatim copies of this license document, but changing it is not allowed. Prea

  • INSYS MLR 3G 2.0, Glossary MLR 3G 2.0 16 Glossary The most important terms and abbreviations used in the manual are shortly described below. APN: The Access Point Name is the name of the processor offering internet ac- cess to the mobile subscribers of GPRS AT Command: Command to devices such as modems for setting this equipment Broadcast: Data packet to be sent to all users of a network Caller ID: The calling line passed by the caller which can be identified by the called telephone Client: Device inquiring services from another device (server) CLIP: The Calling Line Identification Presentation is

  • INSYS MLR 3G 2.0, MLR 3G 2.0 Functions 10.11.4 Resetting the Device You can reset the MLR 3G 2.0 via the web interface or by pressing the reset key on the front of the device. You can simply restart your device or reset all settings to the factory defaults. You can initiate a software reset by shortly pressing the reset key once. A hard- ware reset of the MLR 3G 2.0 can be initiated by pressing it for at least three seconds. A restart will be performed in both cases. Pressing the reset key three times for a short time within two seconds loads the factory defaults of the MLR 3G 2.0. Configuration with the web interface In ord

  • INSYS MLR 3G 2.0, Functions MLR 3G 2.0 10.10.7 Configuring the SNMP Agent The MLR 3G 2.0 provides an SNMP agent that responds to incoming SNMP Get requests. All parameters that exist in the ASCII configuration file, can be read via SNMP Get re- quests (except user name and password of the web interface authentication). These pa- rameters are described in the MIB (Management Information Base). Configuration with the web interface In order to enable the SNMP agent, check in the menu "Server services" on the page "SNMP agent" the checkbox "Activate SNMP agent". In order to download the private MIB, click on the

  • INSYS MLR 3G 2.0, Functions MLR 3G 2.0 10.9.3 Configuring E-Mail Dispatch The MLR 3G 2.0 can send an e-mail to any recipient on different, pre-defined events. An attachment, which can be selected from different log files, can be attached to every e- mail. Moreover, it is possible to attach the status page of the web interface to the mes- sage text. The MLR 3G 2.0 allows to create and manage a series of different combinations of recipient, event, attachment, and text. Sending an e-mail is only possible if the access data for the e-mail account are entered correctly in the menu "Messages" on the page "Configuration". Configuration

  • INSYS MLR 3G 2.0, Functions MLR 3G 2.0 10.10.3 Setting up the DHCP Server On request, the DHCP server of the MLR 3G 2.0 can automatically allocate an address to other devices in the LAN. This automatically allocated, dynamic IP addresses are only valid for a certain time. The validity of the IP addresses allocated by the DHCP server are controlled via the "Lease time". If there is already a DHCP server in the network, in which the MLR 3G 2.0 is used, this function must absolutely be disabled in the MLR 3G 2.0. IP addresses, which are in the IP pool and for which a connection t

  • MLR 3G 2.0 Display and Control Elements Figure 2: LEDs on the rear of the device Position Description 1 Link LED for Switch LAN 1 2 Link LED for Switch LAN 2 3 Link LED for Switch LAN 3 4 Link LED for Switch LAN 4 5 Activity LED for Switch LAN 4 6 Activity LED for Switch LAN 3 7 Activity LED for Switch LAN 2 8 Activity LED for Switch L

  • INSYS MLR 3G 2.0, MLR 3G 2.0 Operating Principle 9 Operating Principle This chapter describes how to operate and configure the MLR 3G 2.0. The MLR 3G 2.0 is configured and operated using a web-based interface. The interface itself is displayed and operated using a web browser such as Mozilla Firefox or Microsoft Internet Explorer. 9.1 Operating the Web Interface The web interface allows easy configuration of the MLR 3G 2.0 using a web browser. All functions of the MLR 3G 2.0 can be configured via the interface. The operation is mostly self-explanatory. The interface also provides an online help fea- ture, which describes the meaning of possible

  • INSYS MLR 3G 2.0, MLR 3G 2.0 Functions 10.3 Dial-In 10.3.1 Configuring Dial-In You can use the MLR 3G 2.0 as dial-in server or incoming PPP server. The dial-in function allows for computers to connect remotely via modem through the MLR 3G 2.0 to the network behind the MLR 3G 2.0. Similar to the dial-in with an Internet provider, users will authenticate themselves via user name and password at the MLR 3G 2.0. To authenticate the PPP users, the methods PAP or CHAP are available. Successfully authenticated users can establish a PPP connection to access the network of the MLR 3G 2.0. Configurat

  • MLR 3G 2.0 Functions 10.8.3 Modem Emulator The serial Ethernet gateway can emulate a modem. It provides a series of AT commands for this. A modem will be emulated for each connection type with this function. If an outgoing connection has been triggered by the ATD command, the modem emulator will always be used, even if it is disabled. The following AT commands are supp

  • Functions MLR 3G 2.0 Define the available IP address pool for the tunnel ends of the PPTP clients in the fields "IP address pool". This pool must be in the network of the LAN. The PPTP clients address their destination directly with IP addresses in the LAN of the MLR 3G 2.0. In order to add a new user, that is permitted for the connection of PPTP cli- ents, enter a user name

  • INSYS MLR 3G 2.0, Index MLR 3G 2.0 18 Index Accessories ...................................................13 Activity LED...................................................17 Additional information .............................26 Aggressive mode.........................................58 Alternative results......................................26 Analysis purposes................................63, 81 APN ........................................................42, 106 ASCII Configuration File............................25 AT command................................38, 67, 106 Authentication ....................................

  • INSYS MLR 3G 2.0, Functions MLR 3G 2.0 10.2 UMTS 10.2.1 Enter SIM card PIN The MLR 3G 2.0 enables to use two SIM cards. If only one SIM card is used, this must be inserted into the card holder for SIM card 1. Additionally, a second SIM card can be in- serted into the card holder for SIM card 2. An operation with one SIM card in SIM 2 with- out a SIM card in SIM 1 is not intended. The MLR 3G 2.0 will need the PIN of the inserted SIM card (if the SIM card is protected by a PIN) to log into the mobile network an

  • INSYS MLR 3G 2.0, Functions MLR 3G 2.0 10.9.5 Configuring SNMP Trap Triggering The MLR 3G 2.0 can trigger an SNMP trap that sends a message to any recipient on dif- ferent predefined events. The MLR 3G 2.0 allows to create and manage a series of differ- ent combinations of recipient and event. The SNMP traps are described in the MIB (Man- agement Information Base). Triggering an SNMP trap is only possible if the settings for the SNMP traps are configured correctly in the menu "Messages" on the page "Configuration". Configuration with the web interface In order to enable triggerin

  • INSYS MLR 3G 2.0, MLR 3G 2.0 Functions 10.11.6 Updating the Firmware You can update the firmware of the MLR 3G 2.0. The firmware is a combination of oper- ating system and programs, in which the functions of the {{PRODUKTBEZEICHNUNG}}} are implemented. To update the firmware, you will need a file with a new firmware, which you can obtain from your sales partner or from INSYS MICROELECTRONICS. It is possible that you get two files for extensive updates. Note Function loss due to faulty update! A connection failure during the update

  • INSYS MLR 3G 2.0, Functions MLR 3G 2.0 10.10.5 Configuring an URL Filter With the help of the URL filter, the proxy of the MLR 3G 2.0 can restrict possible URLs, which can be accessed by computers from the internal network of the MLR 3G 2.0. This will allow only access to URLs which are entered in the filter list. All other URLs are blocked. To allow access to the Internet only via the proxy, the firewall must be activated. Without the firewall, the access to any URLs would be possible just by bypassing the proxy. The IP address of the proxy must be defined at the clients (e.g. a web browser on a PC), which establish connections via the proxy. Configur

  • INSYS MLR 3G 2.0, Licenses MLR 3G 2.0 FAILURE OF THE LIBRARY TO OPERATE WITH ANY OTHER SOFTWARE), EVEN IF SUCH HOLDER OR OTHER PARTY HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES . 14.3 Other Licenses OpenVPN license: ------------------------ Copyright (C) 2002-2005 OpenVPN Solutions LLC <[email protected]> OpenVPN is distributed under the GPL license version 2 (see below). Special exception for linking OpenVPN with OpenSSL: In addition, as a special exception, OpenVPN Solutions LL

  • Copyright © March 11 INSYS MICROELECTRONICS GmbH Any duplication of this manual is prohibited. All rights on this documentation and the devices are with INSYS MICROELECTRONICS GmbH Regensburg. Trademarks The use of a trademark not shown below is not an indication that it is freely available for use. MNP is a registered trademark of Microcom Inc. IBM PC, AT, XT are register

  • INSYS MLR 3G 2.0, Functions MLR 3G 2.0 10 Functions 10.1 Basic Settings 10.1.1 Web Interface (User Name, Password, Remote Configuration) The web interface is used to configure the MLR 3G 2.0. It is protected against unauthor- ized access by a user name and password query. The web interface can be configured for a configuration from a computer in the internal network or for remote configuration. Then, you can also access the web interface from the external network. A remote con- figuration can also be performed via the HTTPS protocol. A location can be entered for a better differentiation. You can define the port, at which the interfac

  • INSYS MLR 3G 2.0, Contents 6 Mar-11 10.11 System Configuration.......................................................................................................81 10.11.1 Displaying the System Log............................................................................................ 81 10.11.2 Displaying the Last System Messages ....................................................................... 81 10.11.3 Configuring Time and Time Zone ............................................................................... 82 10.11.4 Resetting the Device...............................................................................................

  • INSYS MLR 3G 2.0, Functions MLR 3G 2.0 10.11.5 Update You can update the MLR 3G 2.0 with a new firmware or a new configuration using the web interface. A detailed description about these processes can be found in the following sections "Updating the Firmware" and "Uploading the Configuration File" of this manual. Moreover, the MLR 3G 2.0 allows a daily automatic update of firmware files, configura- tion files (binary and ASCII) or sandbox image files. These must be provided on a server accord

  • INSYS MLR 3G 2.0, Commissioning MLR 3G 2.0  The following figure shows how to insert the SIM card into the SIM card holder for SIM card 1: 6. Enable the power supply of the MLR 3G 2.0 again.  You can use a second SIM card in the MLR 3G 2.0 alternatively. The MLR 3G 2.0 provides a second SIM card holder for SIM card 2 for this.  The following figure shows how to insert the SIM card into the SIM card holder for SIM card 2: Connecting the MLR 3G 2.0 to a GSM antenna and a PC How to connect the MLR 3G 2.0 to a GSM antenna and,

Related Products and Documents (Network Router):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 SEWOO LK-P20II Technical manual sewoo/lk-p20ii-4J6.pdf 11 Dec 2022 47
2 Hamilton Beach 26009 Use & care hamilton-beach/26009-MRA.pdf 28 Nov 2023 2 0.79 Mb
3 Whirlpool WTW4850BW1 Use and care manual whirlpool/wtw4850bw1-3KN.pdf 17 Apr 2023 36
4 Apple iPad Handbook apple/ipad-744.pdf 19 Jul 2022 21
5 Uniden UST4800 Reference manual uniden/ust4800-QK2.pdf 25 Jan 2024 80 1.96 Mb
6 Ducati Multistrada 1000ds Workshop manual ducati/multistrada-1000ds-69Q.pdf 17 Aug 2022 592

Similar Resources:

  • TRENDnet

    TEM100-56R

    (2 pages)
    TRENDnet's TEM100-56R PC Card with XpressPort is the perfect solution for LAN/WAN applications. The 16-bit PC Card adapter combines both 10/100Mbps dual speed Fast Ethernet and the optimal power of V.90/K56Flex dual mode 56K fax/modem capabilities. The TEM100-56R makes it simple to combine numerous communication jobs at the same time. The TEM100-56R let …
  • Makita

    3612

    (28 pages)
    1 INSTRUCTION MANUAL MANUEL D'INSTRUCTION MANUAL DE INSTRUCCIONES DOUBLE INSULATION DOUBLE ISOLATION DOBLE AISLAMIENTO IMPORTANT: Read Before Using. IMPORTANT: Lire avant usage. IMPORTANTE: Leer antes de usar. Router Défonceuse Rebajadora 3612 3612C 003647 …
  • Sun Microsystems

    Sun StorEdge Network Data Replicator 3.0

    (30 pages)
    Sun Microsystems, Inc.901 San Antonio RoadPalo Alto, CA 94303-4900 U.S.A.650-960-1300Send comments about this document to: [email protected] StorEdge™Network Data Replicator 3.0Configuration GuidePart No. 806-7550-10June 2001, Revision A …
  • LCD Concepts

    MES-6P-F

    (4 pages)
    USER MANUAL 6-PORT SWITCH for Furuno NavNet 2 MODEL MES-6P-F Version 1.0 LCD Concepts, Inc 2555 South Shore Blvd., Suite D League City, Texas 77573 Phone: (281)334-5181 Fax (281)334-7257 E-Mail: [email protected] www.LCDConcepts.com …
  • TP-Link

    TL-MR3220

    (50 pages)
    Quick Installation Guide3G/4G Wireless N Router7106506338 REV1.0.0TP-LINK TECHNOLOGIES CO., LTD.Specifications are subject to change without notice. TP-LINK is a registered trademark of TP-LINK TECHNOLOGIES CO., LTD. Other brands and product names are trademarks or registered trademarks of their respective holders.No part of the specifications may be reprodu …
  • Grandstream Networks

    GXW40 series

    (40 pages)
    GXW40XX User Manual www.grandstream.com Firmware Version 1.0.5.10 [email protected] Grandstream Networks, Inc. Analog IP Gateway GXW40XX 4, 8 or 24 FXS Ports Models: 7898908277197 / 7898908277180 …

Comments, Questions and Opinions: