Iso-Tech ICM 134 Instruction Manual
|
EN - 2 Safety Information Read and understand this Instruction Manual completely before using this instrument. Failure to observe the warnings and cautions in this Instruction Manual may result in injury or death, or damage to the instrument and other equipment or property. If this instrument is used in a manner not specified in these instructions, the protec- tion provided
Iso-Tech ICM 134, EN - 3 - Wear suitable Personal Protective Equipment when working around or near hazardous Live conductors which could be accessible. - Do not use the thermocouple to measure the temperature of Hazardous Live conductors or equipment. Caution - Disconnect the test leads from the test points before changing the position of the function rotary switch. - Never connect the instrument to a source of voltage with the function rotary switch in Ω/ </ A position. - If possible, do not w
EN - 4 Maintenance Do not attempt to repair this Instrument. It contains no user-serviceable parts. Repair or servicing should only be performed by qualified personnel. This instrument should be calibrated yearly, or more frequently if used in harsh conditions or if it is suspected of being inaccurate. For calibration and repair contact RS Components - the address is
Iso-Tech ICM 134, EN - 5 To conserve battery power, the Auto Power -off function will turn the instrument off approximately 10 minutes after the last operation. 10min To disable the Auto Power-off function: Turn the instrument off, press and hold the “Backlight” button and turn the rotary switch to the required function. The auto Power-off is disabled until the next time the instru- ment is turned off and on again. Power On / Off Auto Power Off
Iso-Tech ICM 134, EN - 8 DC µA Capacitance Note – To improve the measurement accuracy of a small value capacitor, record the reading with the test leads open circuit, then substract the residual capacitance of the Instrument and leads from the final measurement. C UNKNOWN = C MEASUREMENT - C RESIDUAL
Iso-Tech ICM 134, EN - 10 ACA 3 9 2 A CAT.Ⅲ.600V with respect to earth for the jaw. Tactile Barrier for hand guard. Do not hold the meter across the Tactile Barrier. I I I I OK OK OK I + (-I) = 0 Back Light
Iso-Tech ICM 134, EN - 11 Specifications 1-1 General Specifications LCD display digits : 3 3 / 4 digit large scale Liquid Crystal Display. Display resolution : 4000 counts. Measurement rate : 1.5 times / sec. Overrange display : “OL” is displayed for "Ω" functions, The real value is shown for the "A" ,"V" and "°C/°F " function. Automatic power-off time : Approximately 10 minutes after last operation. Low battery indicator : is displayed. Power requirement : 9V battery Type 6LR61, IEC6F22 or equivalent) Battery life : Approximately 200 hours with Alkaline battery. 1-2 Environmental Conditions Ind
EN - 12 Measurement Category lll is for measure- ments performed in the building installation. Examples include measurements on distribution boards, junction boxes, socket- outlets and wiring and cables in the fixed installation. Measurement Category lV is for measure- ments performed at the source of the low-voltage installation. Examples include
Iso-Tech ICM 134, EN - 13 1-3 Electrical Specifications Accuracy is ±(% reading + number of digits) at 23°C (73.4°F) ± 5°C (± 9°F) < 80%RH. Temperature coefficient : Add 0.2 x (Specified accuracy) / °C (1.8°F), < 18°C > 28°C (< 64.4°F >82.4°F). DC / AC Volts Range DC Accuracy AC Accuracy 4.000V ±(0.9% + 2dgt) ±(1.5% + 5dgt) 50Hz ~ 500Hz 40.00V 400.0V DC1000V AC750V Over voltage protection : DC 1000 V or AC 750 V Input Impedance : 10MΩ // less than 100pF. CMRR / NMRR : (Common Mode Rejection Ratio) (Normal Mod
Iso-Tech ICM 134, EN - 14 Diode Check and Continuity Resolution Accuracy 10 mV ±(1.5%+5 dgt)* * For 0.4V ~ 0.8V Max.Test Current : 1.5mA Max. Open Circuit Voltage : 3V Overload Protection : 600Vrms Continuity : The built-in buzzer sounds when the resistance is less than approxi- mately 100Ω. The response time is approximately 100 msec. DC µA Range Accuracy 400.0 µA 4000 µA ±(1%+2 dgt)* Voltage barden : < 5mV / µA Overload Protection : 600Vrms Capacitance Range Accuracy 4.000nF ±(3.0% + 20 dgt) 40.00nF 400.0nF 4
Iso-Tech ICM 134, EN - 15 Temperature Function Range Accuracy -40.0 °C ~ 0.0°C 1% ± 4 °C 0.0 °C ~ 400.0 °C 1% ± 3 °C °F -40 °F ~ 32 °F 1% ± 8 °F 32 °F ~ 750 °F 1% ± 6 °F °C 750 °F ~ 1000 °F 2% ± 8 °F Overload Protection : 600Vrms Battery Replacement When the low battery indicator "" appears on the LCD, replace the batteries with the type given in the specifications. WARNING Disconnect the test leads from the circuit and the instrument before removing the battery cover. Refer to the fo
Iso-Tech ICM 134, EN - 16 Limited Warranty This instrument is warranted to the original purchaser against defects in material and workmanship for 3 year from the date of purchase. During this warranty period, RS Components will, at its option, replace or repair the defective unit, subject to verifica- tion of the defect or malfunction. This warranty does not cover disposable batteries, or damage from abuse, neglect, accident, unauthorized repair, alteration, contamination, or abnormal conditions of operation or handling. Any implied warranties arising out of the sale of this product, including but not lim- ited to i
Iso-Tech ICM 134, Asia Iso-Tech 460 Alexandra Road, #15-01A PSA Building Singapore 119963 USA 7410 Pebble Drive Fort Worth Texas 76118-6961 Europe Iso-Tech PO Box 99 Corby Northamptonshire NN17 9RS United Kingdom Canada 1701 Woodward Drive Ste 108 Ottawa Ontario K2C 0R4, Canada Japan West Tower (12th Floor) Yokohama Business Park 134 Godocho, Hodogaya Yokohama, Kanagawa 240-0005 Japan South America Av. Pdte. Eduardo Frei M. 6001-71 Centro Empresas El Cortijo Conchali, Santiago, Chile
DOWNLOAD |
AEMC 1000N Measuring Instruments Operation & user’s manual
1000N |
Iso-Tech SLA-1358 Measuring Instruments Instruction manual
SLA-1358 |
Incra V27 Measuring Instruments Instructions
V27 |
B&K 2250 Light Measuring Instruments Operation & user’s manual
2250 Light |
Siemens simatic s7-400 FM 450-1 Measuring Instruments Operation & user’s manual
simatic s7-400 FM 450-1 |
Iso-Tech ILCM 06 Measuring Instruments Instruction manual
ILCM 06 |
Ohmite FSP Series Measuring Instruments Integration manual
FSP Series |
Vega VEGAPULS 63 Measuring Instruments Operating instructions manual
VEGAPULS 63 |
# | Manufacturer | Model | Document Type | File | Updated | Pages | Size |
---|---|---|---|---|---|---|---|
1 | HiFiMAN | HE-560 | Owner's manual | hifiman/he-560-EZC.pdf | 12 Aug 2023 | 8 | |
2 | Garden Oasis | D71 M83915 | Owner's manual | garden-oasis/d71-m83915-WP5.pdf | 05 Jun 2023 | 9 | 1.22 Mb |
3 | Cuisinart | GR-4N | Instruction booklet | cuisinart/gr-4n-64H.pdf | 27 Dec 2023 | 29 | 1.39 Mb |
4 | Brother | 882-W01 | Operation manual | brother/882-w01-941.pdf | 22 Dec 2022 | 376 | 52.8 Mb |
5 | Samsung | 450 Series | Installation manual | samsung/450-series-N1T.pdf | 03 Feb 2023 | 71 | |
6 | Denver | DMB-106HD | Operating manual | denver/dmb-106hd-P29.pdf | 28 Mar 2023 | 14 | 0.76 Mb |
Gossen MetraWatt
Firmware Update ToolSoftware Program for Updating the Firmware for the Test Instruments SECUTEST BASE(10)/PRO, SECULIFE ST BASE(25) & PROFITEST PRIME (AC)3-349-793-035/10.17Operating Instructions
…
SECUTEST BASE(8 pages) |
Spektrum
NOTICE: All instructions, warranties and other collateral documents are subject to change at the sole discretion of Horizon Hobby, Inc. For up-to-date product literature, visit http://www.horizonhobby.com and click on the support tab for this product.Meaning of Special Language:The following terms are used throughout the product literature to indicate var …
SPMA9574(8 pages) |
Perel
WEEKLY TIMER – 3600W WEEKTIMER – 3600W MINUTEUR HEBDOMADAIRE – 3600W TEMPORIZADOR SEMANAL – 3600W WOCHENZEITSCHALTUHR – 3600W USER MANUAL NOTICE D’EMPLOI GEBRUIKERSHANDLEIDING MANUAL DEL USUARIO BEDIENUNGSANLEITUNG
…
E305W(10 pages) |
Joy-it
www.joy-it.net Pascalstr. 8 47506 Neukirchen-Vluyn MULTI-FUNCTIONAL TESTER Multi-functional measurement device 1. GENERAL INFORMATION Dear customer, thank you for choosing our product. In the following, we will show you how to use this device. Should you encounter any unexpected problems during use, please do not hesitate to contact us.
…
2860-JT-LCRT7(6 pages) |
Direct Supply
1-800-634-7328 ■ directsupply.com6391Date of Printing: January 2013Distributed by Direct Supply Manufacturing, Inc. 6699 N Industrial Road, Milwaukee, WI 53223.© 2012 Direct Supply Manufacturing, Inc. All Rights Reserved. Direct Supply®, Attendant®, and all associated logos are the registered trademarks of Direct Supply Inc., used under license. Our …
Attendant(2 pages) |
VST
VST inc Lab Coffee IIDigital RefractometerInstructions for Base ModelsCoffee, EpressoCoffee & EspressoRead Instruction Manual Before UseRev DMade in USA© VST, Inc. 2012
…
Lab Coffee 2(8 pages) |
moon DVD Player CalypsoCalypso (DVD Player ePDF User Guide, #3621Z6) Calypso, 39 |
Crown Boiler Boiler 32-380ECS32-380ECS Installation supplement manual - K3LOSS 32-380ECS, 16 |
Icom Transceiver IC-720AIcom Transceiver Instruction manual (File: icom-ic-720a-instruction-manual-44, 20.12.2023) IC-720A, 44 |
Seenergy Network Hardware SVR-104SVR-104 (Network Hardware ePDF User Guide, #HX7D6F) SVR-104, 98 |
Zehnder Pumpen Water Pump Kompaktboy SeriesKompaktboy Series Operation manual - UP5OID Kompaktboy Series, 45 |
Cisco Network Router WS-C4900MManual for Cisco WS-C4900M Network Router WS-C4900M, 276 |
Kingspan Water System Varisol DFWater System PDF Installation manual Varisol DF, 32 |
Schumacher Battery Charger 10 Amp10 Amp Instruction manual - N2S369 10 Amp, 12 |
Metra Electronics Automobile Accessories 99-3306Metra Electronics 99-3306 Guide (Doc Type: Automobile Accessories Installation instructions manual) 99-3306, 8 |
Electrolux Dryer TWSL5E300Guide: Electrolux TWSL5E300 (94935U, Upd.Wednesday 06-12-2023) TWSL5E300, 60 |
First Data Touch terminals VeriFoneVX820 Duet#1O6219: VeriFoneVX820 Duet Touch terminals Quick setup manual VeriFoneVX820 Duet, 8 |
LG Microwave Oven LMVM2055SBMicrowave Oven PDF Owner's manual LMVM2055SB, 35 |