  • KAESER CSD 75, Construction and Operation 5 --- 18 - If the air systems pressure rises to the upper switching point and the running period has already expired, the compressor package is switched off after the run---on period has expired (2). - If the air systems pressure rises to the upper switching point before the running period has expired then the pressure decay time of the previous switching cycle is taken as the criterium for the selection of the operating mode: -- If the pressure decay time t p decay was longer than the period set for the idle/st

  • KAESER CSD 75, Maintenance 9 --- 39 9.9 Venting the compressor unit  Switch off the compressor unit (see chapter 8.4). Lock the main disconnect in the ”off” position in accordance with ap- plicable lock out/tag out procedures to ensure the compressor does not restart. Lock the isolation shut--off valve in the ”closed” position and vent all compressed air trapped between the compressor and the isolation shut--off valve in accordance with applicable lock out/ tag out pro- cedures. The oil circulation system of the compress

  • KAESER CSD 75, Maintenance 9 --- 50 Perform a test run When the operating temperature is reached (see chapter 1.1), shut down the compressor package (see chapter 8.4) and lock the main disconnect in the ”off” position in accordance with applicable lock out/ tag out procedures (example: OSHA CFR 29 § 1910.147) to ensure the compressor does not restart. Afterwards, carry out a visual check for leaks.

  • KAESER CSD 75, Initial Start 7 --- 24 7.3 Checklist  Is the floor at the place of installation solid and level?  yes  no  Is the space large enough for the compressor package or its components?  yes  no  Are inlet and exhaust air apertures available in sufficient size and number?  yes  no  Are all components of the compressor package easily accessible?  yes  no  Is the power supply cable of sufficient cross---section? (have electrical connection carried out by qualified electrician or company familiar with local conditions)  yes  no  Is a shut off valve fitted by the user?  yes  no  Is a flexible connecting

  • SERVICE MANUAL USE Screw Compressor Model: CSD 75 GL---Nr.: 100265_00060---00 01 L Volt L Cabinet heaters.......................... L Wye---Delta Start L 115 V receptacle L D.O.L. Start L Outdoor modification L psig L Rainhoods.......................... LLSwitchable Modulation............................. LLSynthetic lubricant............................. ...........

  • KAESER CSD 75, Maintenance 9 --- 47 9.12.3 Draining the oil using own compressed air  Shut down the compressor unit under full load (see chapter 8.4). Lock the main disconnect in the ”off” position in accordance with ap- plicable lock out/tag out procedures to ensure the compressor does not restart. Lock the isolation shut--off valve in the ”closed” position and vent all compressed air trapped between the compressor and the isolation shut--off valve in accordance with applicable lock out/ tag out proce- dures. The compressor unit oil circulation system vents automatically.  Remove cover panel (3, siee chapter 9.2).  The pressure gauge on

  • KAESER CSD 75, Initial Start 7 --- 25 7.4 Direction of Rotation Check The compressor is wired for connection to a clockwise phase se- quence power supply. A check of the direction of rotation can be made by testing the phase sequence. Arrows showing the direction of rotation are located on the motor and on the airend hous- ing.  On your initial start, ”bump” the unit and verify the direction of rotation. If the direction of rotation is incorrect, change over the supply conductors L1 and L2. If the airend rotate

  • Safety 2 --- 7 2 Safety Regulations Read this service manual carefully and observe cautionary references before putting this compressor package into operation and before carrying out any maintenance. 2.1 Explanation of Symbols and References This symbol is placed before all references to safety where danger to life and limb can occur during work. It is especially important th

  • KAESER CSD 75, Spare Parts and After Sales Service 10 --- 52 10 Spare Parts and After Sales Service 10.1 Service parts and maintenance parts Description Qty. Order No. Oil filter 1 6.3464.0 Air filter cartridge 1 6.3564.0 Filter mat 1 6.3572.0 Oil separator cartridge Complete set Comprising: Separator cartridge Gasket Dirt trap strainer O --- r i n g 1 1 2 1 1 6.3571.0 Important for spare parts orders:  Enter the data on the compressor name plate in the name plate shown above. Always quote the data on the name plate when ordering spare parts. Always order original spare parts from the compressor manufacturer to avoid

  • Maintenance 9 --- 46  Hang the maintenance hose into the container and secure.  Open the oil drain valve (11).  Slowly open the ball valve (7). The remaining pressure in the oil circulation forces out the oil. When air escapes, close the ball valve (7) immediately.  Close the oil drain valve (11).  Disconnect the maintenance hose from the hose coupling (12). Dra

  • KAESER CSD 75, Construction and Operation 5 --- 16 5.5 DUAL Control p max p min Full load Standstill Motor power Pressure Time t1 t2 12345 Idle In DUAL Control (combined idle and start---stop) the compressor normally runs at full-- load, idle or standstill. The controller regulates the compressor package between full--load and idle. If the compressor package runs in idle for longer than the preset period (1) to (2), for example t 1 = 6 min, the drive motor is stopped completely (2). When the lower switching point p min (3) is reached the c

  • KAESER CSD 75, Table of Contents C h a p t e r --- Pa g e iii 11 Appendix 11 --- 53...................................................... 11.1 Wiring Diagram 11 --- 53...................................................... 11.2 Maintenance Schedule 11 --- 72................................................ 11.3 Trouble shooting: Possible cause---Remedy 11 --- 73.............................. 11.3.1 Airend temperature is too high (greater than 167F --- 2 0 0 F) 11 --- 73............... 11.3.2 Motor overload relay switches the unit off 11 --- 73...............

  • KAESER CSD 75, Table of Contents C h a p t e r --- Pa g e i 1 Technical Specification 1 --- 1......................................... 1.1 Compressor Unit 1 --- 1..................................................... 1 . 2 N o i s e Le ve l 1 --- 1.......................................................... 1.3 Motor 1 --- 1............................................................... 1.4 Electrical Connection 1 --- 1................................................. 1.5 Set Point of the Safety Relief Valve 1 --- 2...................................... 1.6 Installation Requirements 1 --- 2......................

Related Products and Documents (Air Compressor):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Kenwood HM-DV5 Instruction manual kenwood/hm-dv5-Q62.pdf 23 Sep 2023 72
2 American Standard Cadet Corner Whirlpool and Bathing Pool 2775.002 Specification sheet american-standard/cadet-corner-whirlpool-and-bathing-pool-2775-002-Q84.pdf 22 Jun 2023 2 0.07 Mb
3 Gigabyte GA-EP43T-S3L Operation & user’s manual gigabyte/ga-ep43t-s3l-ULH.pdf 16 Sep 2022 96 13.63 Mb
4 ZOpid HF-Z097HD Operation & user’s manual zopid/hf-z097hd-U4Q.pdf 02 Nov 2023 26
5 Carrier 90MA/MF/MU Installation, operation and service manual carrier/90ma-mf-mu-3SX.pdf 04 Feb 2024 24 0.56 Mb
6 Platinum CCTV AD-2000 Installation manual platinum-cctv/ad-2000-81X.pdf 28 Nov 2022 4

Similar Resources:

  • Elektra Beckum

    RS 4000

    (40 pages)
    115 171 6993 / 0305 - 1.0Betriebsanleitung. . . . . . . . . . . . . . . . . . . . 3Operating Instructions . . . . . . . . . . . . . . . . 6Instructions d'utilisation . . . . . . . . . . . . . . . 9Handleiding . . . . . . . . . . . . . . . . . . . . . . . 12Betjeningsvejledning . . . . . . . . . . . . . . . . 15Bruksanvisning . . . . . . . . . . . …
  • Ulvac

    C15T

    (63 pages)
    D/N.MD15T00E, 2020SR01 ULVAC CRYOGENICS INCORPORATED COMPRESSOR UNIT Instruction Manual C15T Export Control Policy Vacuum pumps that pump nitrogen gas at pumping speed of 15000L/S or more fall under row 2(35) of appended table 1 of Japan’s Export Trade Control Order, which is based on international export control …
  • GMC

    AC30G

    (16 pages)
    AC30G/AC40G050812 ED5 JJINSTRUCTION MANUAL• Melbourne • Perth • Auckland • Hong Kong • Shanghai • Taipei • New York • Verona • London • ParisWarning!Do not switch on for the first time without first filling with oil.30 Litre & 40 Litre Air Compressors2HP & 2.5HPAC30G_AC40G 12/8/05, 4:48 PM1 …
  • Porter-Cable

    PXCMLC3706056

    (30 pages)
    Compresores eléctricos de aire, de una sola etapa y accionamiento por correaSingle Stage, Belt Drive, Electric Air CompressorsCompresseurs d’air électriques à un étage à entraînement par courroieFrançais : Page 31Español: Página 60 Instruction manualManuel d'instructionsManual de instruccionesPXCMLC3706056200-2887_Rev. A_7-12 …
  • Roll Music Systems

    RMS755

    (2 pages)
    USERSMANUALROLL MUSIC SYSTEMS INC2010 EAST HENNEPIN AVENUE #33MINNEAPOLIS MN 55413612-379-3255WWW.ROLLMUSIC.COMInput channels:Input impedance:Maximum input level:Output channels:Output impedance:Maximum output level:Frequency response:Crosstalk @1kHz:Power requirements:Two40k ohms balanced>+23dBu rmsTwo100 ohms balanced>+29dBu rms12Hz-32kHz +/-0.25dB2 …
  • Air Armor

    M240

    (2 pages)
    Owner’s Manual PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATING YOUR AIR COMPRESSOR Q Industries Inc. 401 East Las Olas Blvd., Suite 130 Fort Lauderdale, Florida 33301 P: 954.689.2263 F 303.568.7700 E Mail: [email protected] Parts and Accessories are available at: www.qindustries-store.net SPECIFICATIONS Motor: 12-Volt D …

Comments, Questions and Opinions: