Menvier Security MF9300 Manual Online:

3.8, 2531 votes
Menvier Security MF9300 User Manual
Menvier Security MF9300 User Guide
Menvier Security MF9300 Online Manual

Text of Menvier Security MF9300 User Guide:

  • Menvier Security MF9300, PAGE26 SYSTEM FAULT FIRE NE L GENERAL FAULT DISABLEMENT TEST POWER POWER FAULT SUPERVISOR MODE REMOTE SIGNAL ISOLATE ALARM LINE DELAY RIBBON 26 WAY CONNECTION TO TERMINAL BLOCK BOARD 8 WAY CONNECTION TO POWER SUPPLY BOARD (TB2) 14 WAY CONNECTION TO TERMINAL BLOCK BOARD (TB1) ALARMS 1 2 34 EARTH FAULT ZONE LED'S 1234 5 6 7 8 9 10 11 12 13 14 15 16 AUX DC FUSE 1A NON LATCH ZONE ALARM 4 FUSE 3.15A ALARM 3 FUSE 3.15A ALARM 1 FUSE 3.15A FUSED MAINS CONNECTOR ALARM 2 FUSE 3.15A ALARM DELAY COIN DETN SYSTEM RESET Positional layout of components for MF9308 & MF9316 pan

  • Menvier Security MF9300, APPENDIX C Installation Of The MF9300 Control Panels General Points: Before actually installing your MF9300 panel please note the following points about the system: The wiring for each of the zones and alarm lines is to be a 2 core parallel circuit with the end of line resistor fitted to the end of the circuit. No 'spurs' or 'tee offs' are permitted. The wiring diagram (Fig.3) gives more details. If a zone is not to be used at all then the end of line resistor must be left in the relevant zone terminal blocks in the panel. All equipme

  • Menvier Security MF9300, PAGE 22 2. Connect the batteries together using the battery connectors contained in the accessories bag - note the polarity of the connections on the assembly diagram (Fig.1). Fit the batteries into the battery compartment of the rear enclosure. 3. Ensure that all external wiring that is to be used is available within the back box and connect them to the correct terminal blocks on the interface board (use Fig.3 for guidance). Connect the inter board connections (one 8 way connector from the power supply board to TB2 on the main board, one 14 way connector from the interface board to TB1 on the main board and one 26 way ribbon connector from the interface board to

  • Menvier Security MF9300, OPERATING THE PANEL General The panel operates in 1 of 2 modes - Normal mode or Supervisor mode. In Normal mode the Supervisor mode LED is extinguished. In Supervisor mode the Supervisor LED is continuously ON. Control of the facilities at the panel is available via the keyboard. A key press is acknowledged by a blip of the internal panel buzzer. All keys that are active in the Normal mode have their legend actual- ly on the key itself, whereas all those facilities that are active once in the Supervis

  • Menvier Security MF9300, IMPORTANT THIS MENVIER FIRE PANEL IS DESIGNED TO BE USED WITH POLARISED AND SUPPRESSED BELLS. DO NOT USE WITH UNSUPPRESSED BELLS, UNSUPPRESSED RELAYS OR NON-POLARISED SOUNDERS OR STROBES ETC. DO NOT CONNECT 230V MAINS DIRECTLY TO THE PCB. ELECTRICAL INSULATION TESTS SHOULD NOT BE CARRIED OUT WITH THE CABLES CONNECTED TO THE PANEL OR DETECTORS OR SOUNDERS. BEFORE MOUNTING THE PANEL PLEASE CARRY OUT THE FOLLOWING TEST: CONNECT ALL END OF LINE RESISTORS TO ZONE AND ALARM LINE TERMINALS (SEE FIG. 3 PG. 27). CONNECT A MAINS SUPPLY, THAT IS NOT SWITCHED ON,TO THE PANEL. SCREW THE CENTRE SECTION INTO PLACE ON THE BACK BOX. CONNECT THE BATTE

  • Menvier Security MF9300, PAGE 20 APPENDIX B Faults - How To Recognise Them And What Action To Take All fault conditions on the fire alarm panel will be indicated by the flashing of the general fault indicator (positioned immediately below the large red fire indicator) and the activation of at least one other fault-specific indicator. By determining which fault-specific indicator is active and by referring to the table shown you can decide on what action to take. INDICATOR FLASH RATE CONDITION ACTION ACTIVE COMPARED TO GENERAL FAUL

  • Menvier Security MF9300, Cooper Lighting and Security Ltd. Wheatley Hall Road, Doncaster, South Yorkshire, DN2 4NB, United Kingdom Sales General Export Tel: +44 (0)1302 - 303303 +44 (0)1302 - 321541 +44 (0)1302 - 303250 Fax: +44 (0)1302 - 367155 +44 (0)1302 - 303220 +44 (0)1302 - 303251 Email: [email protected] [email protected] [email protected] PINST FA9308/V www.cooper-ls.com For service Tel: please call: Service agreement number Lighting and Security

  • Menvier Security MF9300, PAGE 9 Date Zone Event Action required Signed FIRE ALARM SYSTEM LOG APPENDIX A It is recommended that this book is maintained by a responsible executive and that every ‘event’ affecting the installation should be recorded. An ‘event’ should include false alarms, failures, tests, temporary disconnections, the dates of installing engineer’s visits and a note of any out- standing work or conditions.

  • Menvier Security MF9300, The fact that a zone is in test will not prevent the panel from recognising and acting upon fires or faults in other zones. To take a zone out of the test mode you must go into the Supervisor mode and then press Reset. Remote Signal Isolate: To isolate the Remote Signal output press the Remote Signal Isolate button, whilst in Supervisor mode. The Remote Signal Isolate indicator will light, the Disablement indicator will flash and the internal panel buzzer will buzz every 10 seconds. To re-enable the Remote signal again at a later time simply press the Remote Signal Isolate button again. The corresponding indicators will

  • Menvier Security MF9300, Setting System Parameters Certain facilities that can be set up by the service provider at commissioning. They are as follows: Non-latching Zone To enable this facility gain access to the service area of the panel and push the Non-latching zone switch down (Fig.2). Then press the SYSTEM RESET switch. The panel will reset and the non-latching zone feature will be available on zone 1. Coincidence Detection To enable this facility gain access to the service area of the panel. On the bit-switch (see Fig.2)

  • Menvier Security MF9300, TABLE OF CONTENTS ACCESSORIES 1 OVERVIEW 4 SYSTEM OPERATION 4 OPERATING THE PANEL 5 SPECIALISED OPTIONS 8 APPENDIX A Fire Alarm Log 9 Details Of Installation 18 Details Of Modifications 19 APPENDIX B Faults - How To Recognise Them & What Action To Take 20 Fires - How To Recognise Them 20 APPENDIX C Installation Of The MF9308 Control Panels 21 Using The Panel Interfaces 22 Setting System Parameters 24 APPENDIX D Assembly Drawing 25 Positional Layout of Components 26 Wiring Diagram 27 Technical Specifications 28 PAGE 3

  • IMPORTANT NOTICE RELATING TO INSTALLING AND SERVICING THE PANEL WHENEVER POWERING UP THE PANEL FROM A COMPLETELY POWERED DOWN STATE, I.E. NO MAINS OR BATTERY SUPPLY CONNECTED, THE SYSTEM RESET BUTTON MUST BE PRESSED - SEE FIG. 2 FOR THE LOCATION OF THIS PUSH BUTTON. PLEASE ALSO NOTE THAT ACCESS TO THE SERVICE AREA, BEHIND THE UPPER DOOR, SHOULD BE GAINED BY USING THE SPECIAL FORKED KEY PROVIDED.

  • PAGE 6 Reset: This facility allows you to reset the panel. When hit, all panel indicators will light and the internal panel buzzer will sound. On the MF9304 the Fault relay output will also activate. On releasing the button the lights will extinguish, the buzzer will silence and the relay output will deactivate. For a period of approximately 25 seconds after pr

  • Menvier Security MF9300, PAGE 18 DETAILS OF INSTALLATION Zone No. No. of Call Points No. of Smoke Detectors No. of Heat Detectors Location 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 TOTAL CURRENT No. OF SOUNDER BELLS ELECTRONIC OTHER TOTALALARM LOAD: OTHER DETAILS OF EQUIPMENT: THIS SYSTEM HAS BEEN INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF EN54 SIGNED DATE FOR THIS SYSTEM HAS BEEN COMMISSIONED IN ACCORDANCE WITH THE REQUIREMENTS OF EN54 SIGNED DATE FOR

  • Menvier Security MF9300, PAGE 25 Large door Middle moulding Battery cover plate Small door        Back box Battery compartment only Batteries 2 x 12V, 12Ah Mains conduit entry Mains Terminal block Transformer Tra ns former wires colour coded Battery -ve (black) Battery link wire Battery +ve (red) Battery connector (polarised) Transformer connector Zone connector Cable clamp Alarm connector Interface board Battery connector Power connector Power supply board APPENDIX D Assembly drawing for MF9308 & MF9316 FIG 1

  • Class Change A pair of contacts are provided for a class change facility. By short circuiting these contacts via a switch, pulse unit, time clock or by other means, the alarms will sound without illuminating the fire lights. The alarms will cancel when the short circuit is removed. No voltage should be applied to these terminals. Auxiliary Common Output This is a 'solid state'

Related Products and Documents (Fire Alarms):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 BRAWA BR V 180 Operating instructions manual brawa/br-v-180-I94.pdf 09 Sep 2022 10
2 SAF P89 Service manual saf/p89-3A1.pdf 15 Mar 2024 28
3 Sennheiser CC 510 Manual  sennheiser/cc-510-XY4.pdf 18 Feb 2024 61 2.48 Mb
4 Whirlpool AWM 312 Service manual whirlpool/awm-312-C3T.pdf 16 Feb 2023 14
5 Chamberlain PD752CDS 3/4 HP Owner's manual chamberlain/pd752cds-34-hp-LLA.pdf 31 Dec 2023 80
6 SoundTube RS800i Technical information soundtube/rs800i-6TX.pdf 27 Jan 2023 4 0.92 Mb

Similar Resources:

  • Teletek electronics

    SensoIRIS T110 IS

    (2 pages)
    SensoIRIS T110 ISIntelligent analogue addressable fire alarm heat detector with built-in isolator moduleDoP No: 024283119Essential characteristicsPerformance under fire conditionsOperational reliabilityPerformancePassPassTemperature resistanceHumidity resistanceCorrosion resistanceShock and vibrationresistanceDurability:PassPassPassPassEN 54-5:2000+A1:2002 T …
  • Vighnaharta

    TSGR-21

    (43 pages)
    TSGR-21 GAS Release Panel User Manual Vighnaharta Technologies Pvt. Ltd. Page 1 of 43 TRUESAFE GAS R E L E A SE PANE L TSG R -21 USE R MANUAL Mfg. By: Vighnaharta Technologies Pvt. Ltd. 2nd Floor,Karanjkar Estate,S.N.11/11,Nanded Gaon,Pune-411041 Contact no.: +919011033259 (Landline) Sa …
  • Honeywell

    Gent Vigilon

    (47 pages)
    Installation instructionsVigilon panelbased Fire detection and alarm system up to 2kmloop Vigilon Fire SystemGENT 2015Designed to EN54 Pt 2 & 4Healthy15:45FaultSystem FaultTes tFirePowerPower FaultFault/DisDisablementSounderPreviousNextDelayVeri fyActiveFire Routing O/Pwww.acornfiresecurity.comwww.acornfiresecurity.com …
  • System Sensor

    1451

    (52 pages)
    D400-01-01 1 I56-278-05INSTALLATION AND MAINTENANCE INSTRUCTIONSA Division of Pittway 3825 Ohio Avenue, St. Charles, Illinois 601741-800-SENSOR2, FAX: 630-377-6495Before installingPlease thoroughly read the System Sensor manual I56-407,Applications Manual for System Smoke Detectors, whichprovides detailed information on detector spacing, place-ment, zoning, …
  • Bosch

    FCP?320

    (20 pages)
    Automatic DetectorSeries FCP-320, FAP-420, AVENAR detector 4000 Painting Guide | Lackieranleitung | Руководство по окраске deutschenglishрусский …
  • Bosch

    B925F

    (2 pages)
    3 | Installation2.1 | Access the address switches1 | OverviewCaution!Remove all power (AC and battery) before making any connections. Failure to do so might result in personal injury and/or equipment damage.5 | Status indicatorsStatus indicatorFunctionReady to turn on (arm)Turned on (armed)GASGas alarmAC (Mains) power presentFire keypad indicatorFunctionFire …

Comments, Questions and Opinions: