Adisa ADI CD 70 Technical Manual Of Installation, Use And Maintenance

  • ADI CD 70 Boiler
  • maiHF6UAKR5aM
  • Technical Manual Of Installation, Use And Maintenance
  • PDF / Adobe Acrobat Reader
  • 76

Adisa ADI CD 70 Manual Online:

3.8, 990 votes
Adisa ADI CD 70 User Manual
Adisa ADI CD 70 User Guide
Adisa ADI CD 70 Online Manual

Text of Adisa ADI CD 70 User Guide:

  • Adisa ADI CD 70, ADI CD boiler - Technical Manual 37 13. HEATING CIRCUITS For the heating circuits, a number of functions are available (see parameters table) which can be individually set for each heating circuit. Every heating circuit can be a virtual circuit, pump circuit or mixing circuit. The Mixing function is available only when an external extension module (AGU2.550A109) is needed. If, with the mixing circuit, the flow sensor of that circuit is not connected, it becomes a pump circuit with regard to functions. Every boiler is able to control 3 heating circu

  • Adisa ADI CD 70, ADI CD boiler - Technical Manual 53 17.6.4 Adjustable flue damper at the boiler flue outlet Every installation is different because of: - different chimney - different outdoor temperature (maximum and minimum), according to the height on the sea level. The opening of the flue damper must be adjusted according to the values indicated at the beginning of this chapter, for a correct and quick adjustment of the boiler combustion. The damper is included in the boiler supply. For those boilers without built-in flue damper, this can be added as an optional accessory, see

  • ADI CD boiler - Technical Manual 69 (5) (5) (5) (1) (3) (5) (5) (1) (2) (4) (5) (5) (3) (5) (5) (5) (4) (2) 19.2 Position of probes and sensors (1) Water flow temperature sensor (2) Water return temperature sensor (3) Safety overheating thermostat (4) Water pressure sensor (

  • Adisa ADI CD 70, ADI CD boiler - Technical Manual 23 Press OK button and the value will blink. While the value is blinking, use the setting knob to set the correct date. Confirm with OK button. + + Move the setting knob and set the parameter 3 “Year”. Press OK button and the value will blink. While the value is blinking, use the setting knob to set the correct year. Confirm with OK button. + + Press ESC button to return to the main display, where the boiler temperature is shown.

  • ADI CD boiler - Technical Manual 66 18.4.2 Change of fuel: from Propane gas to Natural gas, or vice versa In order to change fuel (this operation must be carried out by an ADISA official service or by authorised professional staff): - Reprogram the control unit - Adjust the boiler combustion with the new fuel to the correct parameters, either for Natural Gas or

  • ADI CD boiler - Technical Manual 43 14. DOMESTIC HOT WATER If there is demand for DHW, the heat sources can be switched on at any time. The strategy is to produce the amount of heat required at a certain point in time – and no more. For that purpose, switching programs, different setpoints and release criteria are available.To activate the DHW, connec

  • Adisa ADI CD 70, ADI CD boiler - Technical Manual 4 1. INTRODUCTION The global trend, European and international, aims at improving energy efficiency both in buildings and generators, in order to reduce pollutant emissions in the atmosphere (SAVE directive, treaty of KYOTO). Carbon dioxide (CO 2) is one of the greenhouse gases that remain the longest in the atmosphere. In accordance with IEO2007, predicted CO2 emissions will be 33.9 billon tons in 2015 and 42.9 in 2030. This is why the European campaign known as “20-20

  • Adisa ADI CD 70, ADI CD boiler - Technical Manual 24 10.3 Available parameters at enduser level  When you are in the main display, press to enter at “Enduser level”.  Choose the required parameter by turning the setting knob and confirm with OK. Modify the parameters depending on the required adjustments. Level Line nr. Function Time of day and date 1 Hours/minutes 2 Day/month 3 Year Operator section 20 Language Time prog heating circuit 1 500-516 Preselection, Phases Time prog heating circuit 2 520-536 Preselection, Phases Time prog 3/heating circuit 3 540-556 Preselection, Ph

  • Adisa ADI CD 70, ADI CD boiler - Technical Manual 30 2379Z05 ON ON 53% 53%53% 80% 40% 40% 80% 80% 80% 80% 80% 100% 100% 100% OFF OFF 53% 53%53% 80% 80% 40% 40% 80% 20% b) Example of boilers sequence and power control Example of a possible sequence that can be made (multiple options can be chosen). In this example, the boilers’activation and their power control would be made as shown below: L eis tB a n d M in = 40% On Ke s On / Kes s O n K e 300 2

  • Adisa ADI CD 70, ADI CD boiler - Technical Manual 64 18.4 Gas/air adjustments All the boilers are tested in our factory and every one is supplied with a table indicating the combustion figures. Both the start-up and the maintenance must be carried out by authorized technical staff. First of all verify: electric supply, if the gas connection is air vented, type of gas and pressure, if the heating demand is at the maximum value, correct draught of the chimney, if the hydraulic installation is vented, if the pump is correctly working... The process would be as follows:  First adjust the combustion at the mi

  • Adisa ADI CD 70, 2 I I N N D D E E X X 1. INTRODUCTION _________________________________________________________________________________ 4 2. REGULATIONS __________________________________________________________________________________ 5 3. EEC APPROVALS AND CERTIFICATIONS ____________________________________________________________ 5 4. BOILER GENERAL VIEW: DESCRIPTION OF THE COMPONENTS ________________________________________ 6 5. DIMENSIONS ____________________________________________________________________________________

  • Adisa ADI CD 70, ADI CD boiler - Technical Manual 56 17.7.4 Water manifold - It avoids hydraulic unbalances between the circuits and the boilers. - It ensures a constant water flow to the boiler, independently from the consumptions required. In accordance with current regulations. - In case of heavy sludge in the water, it drives it to the bottom of the tank. It can not avoid lighter sludge. It is necessary to install (2) an automatic air vent of big capacity in the higher part of the tank, (3) an appropriate drainage with a diameter of 50/60, and optionally, (1) a m

  • Adisa ADI CD 70, ADI CD boiler - Technical Manual 13 8. POWER MODULATION AND COMBUSTION SYSTEM 12 11 7 15 1 5 13 15 5 11 14 6 7 3 2 8 9 4 10 NOTE: this is a guide diagram; according to the model, the position of electrodes, pilot flame, motor fan and gas shut-off valve can vary. Gas filter in models ADI 850 and 950: In these models, the gas filter is supplied dismantled inside the boiler, for an easier and safer transport. It must be assembled once the boiler is in the installa

  • Adisa ADI CD 70, ADI CD boiler - Technical Manual 63 18.3 The boiler control unit and operating cycle The control unit regulates:  The boiler operating cycle.  The boiler safeties (by indicating also the possible reasons for the boiler lockout).  The boiler power modulation. Short description of the boiler operating cycle: LEGEND of the operating phases: Display Meaning 00 Boiler in stand-by (the installation is not receiving any request of heat) 01 The boil

  • Adisa ADI CD 70, ADI CD boiler - Technical Manual 59  System drawing of heating circuits 15 34 11 10a 11 10a 12 17 13 34 11 10a 34 1212 34 11 10a 12 13 17 13 1717 13 10d10d 15 10d  System drawing of one boiler and only D.H.W.

  • Adisa ADI CD 70, ADI CD boiler - Technical Manual 25 10.4 Boiler lockout code 7471z55e/0209 To detect the type of error, see the “list of Error Codes” described at the end of this manual. Once solved the cause of the lockout, reset the boiler by pressing the button RESET during more than half a second. To go back to the initial display, press the button . 10.5 Function boiler maintenance  If you are on the main display (if not, press the button ESCAPE ), press the button “heating operation mode” 7471z49/0109 during 3 seconds at l

  • Adisa ADI CD 70, ADI CD boiler - Technical Manual 32 11.3 Remote Control or telecomputing Boilers provided with the LMS control unit (cascade sequence and circuits’ control) can be connected to a WEBSERVER OZW672 for communication through ETHERNET that allows controlling the boilers’ operation and the installation via WebBrowser in a computer or Laptop and receiving messages and e-mails in Smartphones. Web server OZW672 allows for remote plant control and monitoring via the web:  Operation via web PC/Laptop or Sma

  • Adisa ADI CD 70, ADI CD boiler - Technical Manual 73 22. APPENDIX I: LIST OF ERROR CODES ERROR CODE DESCRIPTION OF ERROR - TEXT DIAGNOSTIC CODE DIAGNOSTIC 0 No error 10 Outside sensor fault Check connection and component 20 Boiler temperature 1 sensor fault 439-440 Short circuit or Open circuit boiler flow sensor (B2). Check connection and component 28 Flue gas temperature sensor fault 539...544 Short circuit or Open circuit flue gas sensor. Check connection and component 30 Flow temperature 1 sensor fault Short circuit or Open circuit flow sensor B1. Check connection and component 32 Flow temperature 2 sensor

  • Adisa ADI CD 70, ADI CD boiler - Technical Manual 22 Overview of setting USER LEVELS SETTINGS Enduser Time of day and date Commissioning Operator section Heating engineer Wireless OEM Time prog heating circuit 1 Time prog heating circuit 2 Time prog 3/heating circuit 3 Time program 4/DHW Time program 5 Holidays heating circuit 1 Holidays heating circuit 2 Holidays heating circuit 3 Certain functions or parameters could be hidden depending on the u

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Black & Decker SLICE RIGHT EK701 Use and care book black-decker/slice-right-ek701-XZO.pdf 17 Jan 2024 2 0.18 Mb
2 Gestetner G060 Service manual gestetner/g060-849.pdf 04 Jul 2022 1106
3 Kanto F3760 Operation & user’s manual kanto/f3760-FVZ.pdf 28 Apr 2023 8
4 Kramer VS-44HC Operation & user’s manual kramer/vs-44hc-J7L.pdf 31 Jul 2023 49
5 Behringer EUROCOM TN6232 Product overview behringer/eurocom-tn6232-4WN.pdf 05 Dec 2022 4 1.05 Mb
6 HP CM749A Operation & user’s manual hp/cm749a-5YX.pdf 01 Dec 2023 252 3.61 Mb

Similar Resources:

  • Cordivari

    PIASTRATERM ISP

    (4 pages)
    USER MANUAL BOILER PIASTRATERM 1. General This document is intended for the installer and final user. Therefore, after plant installation and start-up, ensure that this document has been delivered to the final user or managing supervisor of …
  • Bryan Boilers

    240BHS4T8

    (4 pages)
    Bryan Steam LLC — Leaders Since 1916 783 N. Chili Ave., Peru, Indiana 46970 U.S.A.Phone: 765-473-6651 • Internet:www.bryanboilers.com Fax: 765-473-3074 • E-mail: [email protected] BH Series Steam & Hot Water BoilersNOTE: Units larger than 2040 KW require two power panels.Specifi cations subject to change without notice. Consult factory …
  • Thermona

    THERM EL 8

    (37 pages)
    Operation and Maintenance Manual for Electric Boilers (user manual) version: February, 2008 THERM EL 8 THERM EL 15 THERM EL 23 THERM EL 30 THERM EL 38 THERM EL 45 …
  • Estia

    HWS-2101CSHM3-E

    (15 pages)
    AIR TO WATER HEAT PUMP SYSTEMInstallation manualHOT WATER CYLINDERINDIRECT HEATING METHODCLOSED OUTLET (UNVENTED)150 litre HWS-1501CSHM3-E210 litre HWS-2101CSHM3-E300 litre HWS-3001CSHM3-EAIR TO WATER HEAT PUMP SYSTEMINSTALLATION AND SERVICE MANUAL 3ENSYSTÈME DE POMPE À CHALEUR AIR-EAUMANUEL D'INSTALLATION ET DE RÉPARATION 14FRLUFT-WASSER-WARMERPUMPE …
  • FULTON

    RB Series

    (74 pages)
    This manual must be available to the boiler operator at all times.RB-RBC-IOMM-2015-1INSTALLATION, OPERATION AND MAINTENANCE MANUALRB / RBC Series Gas / Oil / Dual Fuel Horizontal Steam Boilers …
  • Bosch

    Tronic 2500 TO

    (40 pages)
    6 720 876 005 (2018/12) DIVMontage- und Gebrauchsanleitung | Installation and operating instructions | Notice de montage et d’utilisation | Istruzioni per l‘uso e per il montaggio | Montage- en gebruikshandleiding | Упътване за монтаж и употребаTronic 2500 TO | Tronic 3500 TO | Tronic Store AdvancedTR2500TO 5 B | TR3500TO(R) 5 T …

Comments, Questions and Opinions: