  • PLEASE READ THE USER GUIDE CAREFULLY BEFORE INSTALLATION AND RETAIN FOR FUTURE USE. Cavius DIY Smoke Alarm Model 2008-002 / 10012 / 10013 / 10014 Manufactured by CAVIUS For large text option and maintenance guide visit www.cavius.co.nz/resources www.cavius.com.au/resources 1.

  • The CAVIUS™ is smoke alarm is a photoelectric alarm designed to be installed into residential homes, camper-vans and caravans. It is not recommended for boats. CERTIFIED TO AUSTRALIAN STANDARD AS3786:2014 2.

  • Cavius 2008-002, The best locations in your home to install the smoke alarm: • Place a smoke alarm between possible fire sources and bedrooms as a minimum. • Smoke alarms on each floor, in hallways and stairways. • Smoke alarms in each room such as bedrooms and living rooms. Additional smoke alarms will increase the security. The NZ and Australian Fire Services recommend smoke alarms in every bedroom, hallway and living area for early re detection. 4.

  • Cavius 2008-002, Installation of smoke alarm: 1. Use the mounting base ring to mark the screw holes on the ceiling. Use the enclosed screws and plugs for installing the mounting base. MARK UP SCREW HOLES WITH A PEN Info: The label in the product must not be removed due to important information regarding the product. 6.

  • Cavius 2008-002, Placement: Designed for placement on ceiling (preferred) or wall. The smoke alarm should be a minimum 50 cm from the wall, with a minimum of one smoke alarm per floor and a maximum distance between smoke alarms of 10 metres. CEILING CEILING WALL WALL 50cm MINIMUM 50cm FROM WALL MINIMUM 30cm AND MAXIMUM 50cm FROM CEILING 8.

  • 2. After mounting, allow 5 seconds for the alarm to power up and then test the smoke alarm by pushing the test button (which is the entire top of the alarm). The alarm should produce a loud sound 9.

  • Cavius 2008-002, The smoke alarm may NOT be placed: • In dusty rooms • At the top of high pointed ceilings, instead place a minimum of 50cm to a maximum of 150 cms from the appex. • Within 50cm of a wall. • In rooms where the temperature goes outside +5º to 45ºC or above 90% relative humidity non condensing. • In kitchens, garages, or too close to fireplaces. In areas that get damp or where gases may occur. Place the smoke alarm where it is reachable in order to test the battery and complete maintenance. 10.

  • Cavius 2008-002, Maintenance: The smoke alarm should be vacuum cleaned once per quarter, and can be wiped with a slightly damp cloth (do not open the alarm). Test the smoke alarm once per month by pushing the test button. The smoke alarm should produce a loud alarm tone. 11.

  • Cavius 2008-002, FUNCTIONAL INFORMATION Type of alarm: CAVIUS™ smoke alarm is a photo electric smoke alarm. Alarm signal: Fire alarm activation is indicated by a series of repeated tones. The minimum sound level is 85 dB at 3 metres. Battery: Powered by a non-replaceable 3v CR123 A DURACELL Lithium battery with 10-year life (included). 12.

  • Cavius 2008-002, Low battery indicator: A short acoustic “beep” will sound and the LED will flash every 48 seconds when the battery is near the end of its life. In this stage it will continue for a minimum of 30 days. You must change the smoke alarm after 10 years of use, or if the smoke alarm has suffered any damage. The smoke alarm is not active unless it is clicked into the mounting base. Always test the smoke alarm after clicking into the mounting base, allow 5 seconds before testing. 13.

  • Cavius 2008-002, Smoke alarm signal: The smoke alarms have a visual and acoustic signal. In the passive state, the LED will flash every 48 seconds to indicate normal function. In alarming state the LED will flash and the alarm will emit a sweeping sound pattern designed to alert occupants. 14.

  • Cavius 2008-002, Hush function: In case of unintentional or false alarms, press the hush button for 2 seconds (which is the entire bottom of the alarm). This will mute the alarm for 10 minutes, after which time the alarm will automatically resume its normal function. 15.

  • Fault nding: If the smoke alarm activates without a visible smoke or fire presence, then possible causes could be: • Dust particles which have entered the smoke chamber, these can be removed by vacuuming around the mesh. If the smoke alarm does not work when the test button is pushed, please check our Trouble Shooting Guides at; www.cavius.co.nz and www.cavius.com.au 1

  • Cavius 2008-002, Other information: • Do not paint the smoke alarm. • Note the local country regulations regarding installation of mains powered smoke alarms in new buildings. Disposal: For battery and product, please dispose properly at end of life. This is electronic waste that should be recycled. 17.

  • Cavius 2008-002, MANUFACTURED BY: Aps Julsøvej 16 - DK8600 Silkeborg www.cavius.com - [email protected] Manufactured in P.R.C. DISTRIBUTOR INFORMATION: CAVIUS Nano Ltd. 8 King Street, Te Puke. 3119, Bay Of Plenty 3118. P.O Box 11241, Palm Beach Plaza, Papamoa, Bay Of Plenty 3151, New Zealand. www.cavius.co.nz Hotline: 0800 766533 or 07 542 2191 REP ELEC. Locked Bag 45, Plumpton, NSW 2761, Australia. www.cavius.com.au - PH: 1300 555 586 126982 rev2 18.

  • Cavius 2008-002, Warranty: Your CAVIUS™ smoke alarm has a 5 year warranty from the date of purchase against defect in material and workmanship. Faulty units during this period can be returned to the place of purchase. You must provide the proof of purchase date and such defects will be repaired, or replaced at the distributors option, without charge. This Warranty only covers defects in materials or workmanship in normal residential use and does not cover damage resulting from negligent handling, misuse or lack of reasonable care. This warranty is in lieu of any other warranty eithe

  • Cavius 2008-002, Type of mounting Ceiling and Wall Mounting Main power supply Internal power source (battery included) Battery duration 10 years Interconnectable device Yes No Suitable for installation in mobile home Yes No Product overview: 20.

  • Connection to external auxiliary devices Yes No Radio link Yes No Individual alarm indicator Yes No Alarm silence facility (10min) Yes No No radioactivity infrared technology Yes No Accessibility option Yes No 21.

Related Products and Documents (Smoke Alarm):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Mitsubishi Electric MSZ-FD09NA Installation manual mitsubishi-electric/msz-fd09na-7UL.pdf 02 Sep 2023 8
2 GE ZBD4800 Use and care manual ge/zbd4800-9BN.pdf 23 Mar 2024 16
3 ZKTeco Plock 2 Operation & user’s manual zkteco/plock-2-U5M.pdf 27 Dec 2023 6
4 Garland Infra-Red Salamander Broiler BS-CX Specifications garland/infra-red-salamander-broiler-bs-cx-84L.pdf 04 Jan 2023 2 0.18 Mb
5 Cocos Smart Sense Quick installation manual cocos/smart-sense-SPJ.pdf 04 Apr 2024 7
6 Kenwood KDC-334SA/SG Instruction manual kenwood/kdc-334sa-sg-7R1.pdf 08 Jul 2023 28

Similar Resources:

  • First Alert

    SA340

    (6 pages)
    USER’S MANUALPrinted in MexicoM08-0143-002 J1 05/07INTRODUCTIONThank you for choosing First Alert®for your Smoke Alarm needs. Youhave purchased a state-of-the-art Smoke Alarm designed to provideyou with early warning of a fire. Please take the time to read this manualand make the Smoke Alarm an integral part of your family’s safety plan.Key Features o …
  • Honeywell

    DFS8MS

    (2 pages)
    getconnected.honeywell.comx2x2=WEBDFS8MS https://international.mytotalconnectcomfort.com https://international.mytotalconnectcomfort.comx2x2=WEBDFS8MS https://international.mytotalconnectcomfort.com https://international.mytotalconnectcomfort.comx2x2=WEBDFS8MS https://international.mytotalconnectcomfort.com https://international.mytotalconnectcomfort.comx2x2 …
  • Polon-Alfa

    POLON 4000

    (105 pages)
    POLON 4000 INTERACTIVE FIRE DETECTION AND ALARM SYSTEM POLON 4900 FIRE DETECTION AND ALARM ADDRESSABLE CONTROL PANEL …
  • Fireray

    FD2705R

    (11 pages)
    FEATURES • Microprocessor controlled • Range 5 – 50 Metres • Range 50 – 100 Metres • Unique simple alignment • Loop powered • Selectable alarm thresholds • Low current consumption • Automatic contamination compensation         � …
  • System Sensor

    B501BH

    (4 pages)
    D650-03-00 1 I56-491-06RB501BH Sounder BaseINSTALLATION AND MAINTENANCE INSTRUCTIONS3825 Ohio Avenue, St. Charles, Illinois 601741-800-SENSOR2, FAX: 630-377-6495www.systemsensor.comBefore InstallingPlease read the System Smoke Detector Application Guide,which provides detailed information on sensor spacing.placement, zoning, wiring. and special applications. …
  • Siemens

    DELTA reflex 5TC1 290

    (16 pages)
    251653.41.03 "DS 09 " Seite 1 von 4 Page 1 of 4 Produkt- und Funktionsbeschreibung Product and Applications Description Der DELTA reflex Rauchmelder Batterie (VdS) ist für den Einsatz im privaten Wohnbereich konzipiert. Der Rauchmelder erkennt frühzeitig den bei Bränden entstehenden Rauch und gibt Alarm. Neben dem Einzelbetrieb k …

Comments, Questions and Opinions: