CDP UPO 11-1 Operation & User’s Manual

CDP UPO 11-1 Manual Online:

3.35, 1858 votes
CDP UPO 11-1 User Manual
CDP UPO 11-1 User Guide
CDP UPO 11-1 Online Manual

Text of CDP UPO 11-1 User Guide:

  • CDP UPO 11-1, During power failure, you may extend the backup time to critical devices by setting shorter backup time for non-critical devices. Step 4: Communication connection Communication port: To allow for unattended UPS shutdown/start-up and status monitoring, connect the communication cable one end to the USB/RS-232port and the other to the communication port of your PC. With the monitoring software installed, you can schedule UPS shutdown/start-up and monitor UPS status through PC. The UPS is equipped with intelligent slot perfect for either UPO SNMP or SNMP

  • CDP UPO 11-1, 13: Maximum charger current setting Interface Setting Parameter 2: Set up the charger maximum current. For low voltage model with 24/36/48VDC 1/2/4/6/8: setting the charger maximum current 1/2/4/6/8 in Ampere. (Default: 2A) For high voltage model with 24/36/48VDC 1/2/4/6/8/10/12: setting the charger maximum current 1/2/4/6/8/10/12 in Ampere. (Default: 2A) For low voltage and high voltage model with 72/96VDC 1/2/4/6/8: setting the charger maximum current 1/2/4/6/8 in Ampere. (Default: 2A) Note: Please set the appropriatecharger current based on battery capacity used. The recommended charg

  • CDP UPO 11-1, 1. Important Safety Warning Please comply with all warnings and operating instructions in this manual strictly. Save this manual properly and read carefully the following instructions before installing the unit. Do not operate this unit before reading through all safety information and operating instructions carefully. 1-1. Transportation Please transport the UPS system only in the original package to protect against shock and impact. 1-2. Preparation Condensation may occur if the UPS system is moved directly from cold to warm environment. The UPS system must be abs

  • CDP UPO 11-1, 19: Acceptable input voltaje range setting Interface Setting Parameter 2: Set the acceptable high voltage point and acceptable low voltage point for input voltage range by pressing the Down key or Up key. HLS: Input high voltage point For 200/208/220/230/240 VAC models: 280/290/300: setting the high voltage point in parameter 2. (Default: 300Vac) For 100/110/115/120/127 VAC models: 140/145/152: setting the high voltage point in parameter 2. (Default: 150Vac) LLS: Bypass low voltage point For 200/208/220/230/240 VAC models: 110/120/130/140/150/160: setting the low voltage point in parameter 2. (Default: 110Vac) For 100/110/115/120

  • CDP UPO 11-1, 04: ECO enable/disable Interface Setting Parameter 2: Enable or disable ECO function. You may choose the following two options: ENA: ECO mode enable DIS: ECO mode disable (Default) 05: ECO voltaje range setting Interface Setting Parameter 2: Set the acceptable high voltage point and low voltage point for ECO mode by pressing Down key or Up key. HLS: High loss voltage in ECO mode in parameter 2. For 200/208/220/230/240 VAC models, the setting range in parameter 3 is from +7V to +24V of the nominal voltage. (Default: +12V) For 100/110/115/120/127 V

  • CDP UPO 11-1, 01: Output voltaje setting Interface Setting Parameter 2: Output voltaje For 200/208/220/230/240 VAC models, you may choose the following output voltage: 200: presents output voltage is 200Vac 208: presents output voltage is 208Vac 220: presents output voltage is 220Vac 230: presents output voltage is 230Vac (Default) 240: presents output voltage is 240Vac For 100/110/115/120/127 VAC models, you may choose the following output voltage: 100: presents output voltage is 100Vac 110: presents output voltage is 110Vac 115: present

  • CDP UPO 11-1, When connecting external battery packs, please be sure to connect polarity correctly. Connect positive pole of battery pack to positive pole of external battery connector in UPS and negative pole of battery pack to negative pole of external battery connector in UPS. Polarity misconnection will cause UPS internal fault. It’s recommended to add one breaker between positive pole of battery pack and positive pole of external battery connector in UPS to prevent damage to battery packs from internal fault. The required specification of breaker: voltage ≧ 1.25 x battery voltage/set; current ≧ 50A Please choose battery size and connected numbers according to backup time re

  • CDP UPO 11-1, RT Models 1. Programmable outlets: connect to non-critical loads. 2. Output receptacles: connect to mission-critical loads. 3. AC input 4. Network/Fax/Modem surge protection 5. USB communication port 6. RS-232 communication port 7. SNMP intelligent slot 8. Emergency power off port (EPO) 9. External battery connection 2-2. Operating principle The operating principle of the UPS is shownas below The UPS is composed of mains input, EMI/RFI filters, rectifier/PFC, inverter, battery charger, DC-to-DC converter,battery, dynamic bypass and UPS output.

  • 16: EPO Logic setting Interface Setting Parameter 2: Set up the EPO function control logic. AO: Active Open (Default). When AO is selected as EPO logic, it will activate EPO function with Pin 1 and Pin 2 in open status. AC: Active Close. When AC is selected as EPO logic, it will activate EPO function with Pin 1 and Pin 2 in close status. 17: External output is

  • CDP UPO 11-1, 2-3. Install the UPS(Only for RT Models) For safety consideration, the UPS is shipped out from factory without connecting battery wires. Before install the UPS, please follow below steps to re-connect battery wires first. This UPS can be either displayed on the desk or mounted in the 19” rack chassis. Please choose proper installation to position this UPS. Rack-mount Installation Tower Installation

  • 2. Installation and setup NOTE: Before installation, please inspect the unit. Be sure that nothing inside the package is damaged. Please keep the original package in a safe place for future use. OPTIONAL: If the end user wants other cases for application outdoor, it is posible to change the cases; consult your dealer. 2-1. Rear panel view Tower Model

  • CDP UPO 11-1, Table of Contents 1. Important Safety Warning....................................................................1 1-1. Transportation..........................................................................................1 1-2. Preparation................................................................................................1 1-3. Installation................................................................................................1 1-4. Operation..............................................................

  • CDP UPO 11-1, Operating Mode Description LCD Display ECO mode Energy saving mode: When the input voltaje is whitin voltaje regulation range, UPS will bypass voltaje to output for energy saving. The UPS will also charge the battery at ECO mode. Frequency Converter mode When input frequency is within 40Hz to 70Hz, the UPS can be set at constant output frequency, 50Hz or 60Hz. The UPS will still charge battery under this mode. Battery mode Energy saving mode: When the input voltaje is whitin voltaje regulation range, UPS will bypass voltaje to output for e

  • CDP UPO 11-1, 07: Bypass voltaje range setting Interface Setting Parameter 2: Set the acceptable high voltage point and acceptable low voltage point for Bypass mode by pressing the Down key or Up key. HLS: Bypass high voltage point For 200/208/220/230/240 VAC models: 230-264: setting the high voltage point in parameter 3 from 230Vac to 264Vac. (Default: 264Vac) For 100/110/115/120/127 VAC models: 120-140: setting the high voltage point in parameter 3 from 120Vac to 140Vac. (Default: 132Vac) LLS: Bypass low voltage point For

Related Products and Documents (UPS):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Commax DRC-2AB1(B&W) Operation & user’s manual commax/drc-2ab1bw-884.pdf 21 Jun 2023 18
2 Vastera VA-103 Operation & user’s manual vastera/va-103-WF4.pdf 14 Apr 2023 22
3 Adam S3A Operation manual adam/s3a-D5W.pdf 26 Oct 2022 32
4 Sony SLV-900HF Operating instructions manual sony/slv-900hf-GV5.pdf 06 Sep 2023 72 13.23 Mb
5 FujiFilm YV2.8x2.8SR4A-SA2 Specifications fujifilm/yv2-8x2-8sr4a-sa2-338.pdf 23 Aug 2022 1 0.31 Mb
6 Dell M2400 - Precision Mobile Workstation Administrator's manual dell/m2400-precision-mobile-workstation-73N.pdf 09 Feb 2023 143 7.38 Mb

Similar Resources:

  • TSi Power

    UPS-400

    (2 pages)
    LIMITED WARRANTYTSi Power warrants this product to be free from defects in materials andworkmanship for two (2) years† from the date of purchase from TSi Power or itsauthorized representatives. TSi Power will repair (or at its option, replace) anydefective component(s) during this warranty period.To make a request or claim for service under this limited w …
  • Toshiba

    T1000 Series

    (3 pages)
    T1000 Series UPS 4-Post Rack Slide Kit Installation Instructions 94034-000 1T1000 Series UPS 4-Post Rack Slide Kit Installation Instructions- 94034-0001. 4-Post Rack Slide KitUse the 4-Post Rack Slide Kit 92800 (1 kit per module) to mount a T1000 module with slides in a 19-inch, 4-Post rack. The slide assemblies are non-handed, and are provided with a lo …
  • Mustek

    POWERMUST 636

    (1 pages)
    Features PPRROODDUUCCTT IINNFFOO Product Type Uninterrupted power supply line interactive Input Capacity 600 VA / 360 W z Voltage 220/230/240 VAC z Voltage Range 170 – 285 VAC Output z Voltage Regulation (Battery Mode) ± 10 % z Optional DC Voltage (USB) 5 V z Frequency Range (Battery Mode) 50 Hz ± 1 Hz z Transfer Time Typical 2 – 6 ms …
  • Tripp Lite

    SMART1000LCDU

    (24 pages)
    1Owner’s Manual Digital UPS System SMART1000LCDUNot suitable for mobile applications.PROTECT YOUR INVESTMENT!Register your product for quicker service and ultimate peace of mind. You could also win an ISOBAR6ULTRA surge protector— a $100 value!www.tripplite.com/warranty1111 W. 35th Street, Chicago, IL 60609 USA • www.tripplite.com/supportCopyright © …
  • Siemens

    667/HB/47750/000

    (76 pages)
    Infrastructure and Mobility, Traffic SolutionsSopers Lane, Poole, DorsetBH17 7ERVersion 7 Page 1 of 76 StatusISSUEDLast Editor Ore Oluwatudimu TS008468 Date 31/01/2017DocumentNameUPS Solution General Handbook Doc. No. 667/HB/47750/000Copyright  Siemens plc 2017 All Rights ReservedUPS Solution General HandbookPart no.667/HB/47750/000THIS DOCUMENT IS ELECT …
  • Sanyo Denki

    SANUPS E11A Series

    (11 pages)
    Uninterruptible Power Supply E11A(TYPE C) Series A11F102/152 Series Contact Signal Interface Card (Terminal type) User Manual Table of Contents Introduction Safety Precautions 1. Confirming Package Contents -------------------- 1 2. Contact Signal Interface Card Part Names ---- 1 3. Contact Signal Interface Card Installation ------ 2 4. …

Comments, Questions and Opinions: