  • CDVI BIOSYS 1, 2 v 1 1 2 2 1 4 1 1 2 2 2 2 x1 x10 IP52 DEEE -10°C to +50°C The BIOSYS 1 product complies with Directive 1999/5/CE Wiring Reminder The maximum distance between the controller and the reader head is 50m. Beware of mains (240Vac) connections. Recommended cables> 3 twisted pairs (EIA-485 standard), 3P SYT 24 AWG. Make sure the drain wire PE is connected. Environment The door controller must be installed internally. The reader head must be installed in a sheltered location from the weather. Operating temperature range of -10°C to + 50°C. Installation Recommendation To li

  • CDVI BIOSYS 1, 3 www.cdvigroup.com MOUNTING ¿8 ¿5 35 mm 1.38 po 90° ø5 35 mm 1.38 po 1 1 2 3 4 5 6 7 LED Colour MODE BLUE Standby WHITE Finger detected RED Access denied GREEN Access granted ORANGE Waiting for command RED (ashing) Programming error

  • 5 www.cdvigroup.com WIRING 2 < 50 m / 164 ft SYT 3P 24AWG IP52 IP52 Pa2 Pa3 RL1 NO C NC RL2 NO C NC V V 12VDC (-10% / +20%) 12VDC Alarm IN 12V Bus OUT 12V Door Pa1 PE ! Make sure the drain wire PE is connected

  • CDVI BIOSYS 1, 6 PARAMETERS 3 26 bits 30 bits 44 bits WIEGAND ON ON OFF OFF OFF OFF 1 sec. 5 V WIEGAND 5 sec. 12 V 10 sec. 15 sec. ON ON ON ON ON OFF OFF OFF OFF OFF 4 5 6 7 1 LOCK RELAY TIME G Common Ground H Clock D0 Data 0 D1 Data 1 83 109 DIP switch NOT USED 2 1 OFF Reset mastercard System default

  • CDVI BIOSYS 1, 7 www.cdvigroup.com PARAMETERS J1 J2 J3 J4 J5 P1 ON OFF J2 J3 J4 J5 2 ON ON OFF J1 J1 J1 P1 P1 P1 1 2 INSTALLATION WITH ONE READER HEAD Buzzer Permanently lit Tamper alarm NOT USED - + M B A M B A - + INSTALLATION WITH TWO READER HEADS PE PE ! Make sure the drain wire PE is connected

  • CDVI BIOSYS 1, 8 FIRST TIME POWER UP 4 1/2/3 1 START BIOSYS1 2 X1 X1 X1 ! ! X1 X6 REGISTRATION OF FINGERPRINTS UP TO 500 USERS User Card already assignedUnknown Master Card Return to section 1,2 & 3 Place your nger on the sensor until the unit BEEPs, remove and place again - do this 6 times in total. X1 20 secs Master Card BEEPBEEP BEEP Master Card User Card BEEP BEEP BEEP When the registration of the user is completed, the unit will change to white. At this point the ngerprint can be veried - then the unit changes to blue standby. If

  • CDVI BIOSYS 1, 9 www.cdvigroup.com NORMAL USE 5 X1 X1 1S ! MORE PROGRAMMING 6 1 REMOVING A FINGERPRINT X1 X1 X1 5S / 8S max. ! Unrecognised ngerprint Unknown User Card BEEP BEEP User Card BEEP BEEP BEEP If “Permanently Lit” is selected, then the LED surround will indicate all the time. If “Permanently Lit” is not selected, then the LED surround will be off, and will only indicate when it senses a nger present - with no activity, the LED surround will remain lit for 30 seconds then switch off. Preference of surround LED’s is selected by (see page 7). J4

  • CDVI BIOSYS 1, 10 4 RESET 30S ON OFF OFF 2 4 1 MORE PROGRAMMING 6 3 MASTER CARD CANCELLATION 1S ON OFF OFF 1 X1 X3 2 DUPLICATE THE MASTER CARD B A B A = DIP switch DIP switch Return to Section 4.1 Existing Master Card New Master Card BEEP BEEP Note: After deleting a Master Card, the next Master Card presented will automatically be added - as indicated by the green LED Note: Leave DIP 2 on until the FIRST red LED ash with an audible “chirp” - turn DIP 2 off. A further 3 red ashes will occur, followed by blue then ashing orange - a new Master Card can now be added.

  • CDVI BIOSYS 1, 11 www.cdvigroup.com A General Alarm will be activated: • If the door contact (CP) is connected and there has been an attempt to force the door; or the door was not closed within 60 seconds of a valid transaction. • If there is loss of communication between the controller and the reader head for more than 25 seconds. • If there is an attempt to remove the reader head (tamper detection). While in programming mode, inaction will revert the reader head to sleep mode. Return to Section 4.1 Important note: The user cards are unique, and used for the registration and deletion of users. It is important to note which user card is registered to which use

  • CDVI BIOSYS 1, CDVI FRANCE + EXPORT Phone: +33 (0)1 48 91 01 02 CDVI AMERICAS [CANADA - USA] Phone: +1 (450) 682 7945 CDVI BENELUX [BELGIUM - NETHERLAND - LUXEMBOURG] Phone: +32 (0) 56 73 93 00 CDVI TAIWAN Phone: +886 (0)42471 2188 CDVI SUISSE Phone: +41 (0)21 882 18 41 CDVI CHINA Phone: +86 (0)10 84606132 CDVI IBÉRICA [SPAIN - PORTUGAL] Phone: +34 (0)935 390 966 CDVI ITALIA Phone: +39 0321 90 573 CDVI MAROC Phone: +212 (0)5 22 48 09 40 CDVI SWEDEN [SWEDEN - DENMARK - NORWAY - FINLAND] Phone: +46 (0)31 760 19 30 CDVI UK [UNITED KINGDOM - IRELAND] Phone: +44 (0)1628 531300 cdvigroup.com +50° C -10° C

More Instructions:

DOWNLOAD
DOWNLOAD
DOWNLOAD

Related Products and Documents (Security System):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 NETGEAR FS116P Installation manual netgear/fs116p-2D7.pdf 04 Feb 2023 1
2 Dixon RAM XS5025BF / 968999725 Operator's manual dixon/ram-xs5025bf-968999725-1M4.pdf 12 Feb 2024 72 4.18 Mb
3 Midian IS-1 Operation & user’s manual midian/is-1-3NC.pdf 12 Jun 2023 16
4 Selva Corse Owner's manual selva/corse-7WD.pdf 08 Feb 2024 31
5 um XT-4 CW Operation & user’s manual um/xt-4-cw-344.pdf 01 Nov 2023 2
6 Volkswagen 2013 Golf R User booklet volkswagen/2013-golf-r-EO1.pdf 19 Nov 2023 5 3.73 Mb

Similar Resources:

  • DAVIS

    Vantage Pro2

    (56 pages)
    Vantage Pro2Console Manual™For Vantage Pro2 & Vantage Pro2 Plus Weather Stations™™Davis Instruments, 3465 Diablo Avenue, Hayward, CA 94545 • 510-732-9229 • www.davisnet.com …
  • Topnics

    TP-PCA7201

    (4 pages)
    TP-PCA7201 User Manual Form one-stop shopping your best choice and professional partner http://www.topnics.com Tel : +86 755 22202283 / +86 755 25932575 Fax : +86 755 25932565 Email : [email protected] 1/4 TP-PCA7201 User Manual I: Introduction Thank you for purchasing our products, in order to give y …
  • HumanTechnik

    Lisa A-2414-0

    (28 pages)
    DBedienungsanleitungBlitzlampeSeite 2GBOperating InstructionsFlash lampPage 6FMode d’emploiLampe-flashPage 10NLGebruiksaanwijzingFlitslampPagina 14IIstruzioni per l’usoLampada flashPagina 18EInstrucciones de servicioLámpara de destellosPágina 22HUMANTECHNIKlisa …
  • GSI Electronics

    Agri-Alert 800EZe

    (2 pages)
    Wiring Diagram / Schéma de branchementAA800EZe Interactive Tutorial Available Online !AA800EZe Tutoriel interactif disponible en ligne !http://www.viatron-electronics.com/aa800eze/Agri-Alert 800EZeZONE INPUTSZ5 COM Z6Z3 COM Z4Z1 COM Z2Z7 COM Z8 1 2-COMM--++ NO C NC NO C NC~~12VDC SIREN RELAY 1 RELAY 216VAC1.5k1/2W +-Battery / BatterieEARTH+-12V+-*The system …
  • NAPCO

    FREEDOM -

    (6 pages)
    The revolutionary code-free system as easy as locking the door, eliminates callbacks, account attrition and 100% of false alarms caused during exit/entry (the times 85% all false alarms occur in traditional systems.) Napco’s Freedom System installs in as little as an hour and uses all standard Gemini Wireless. Starting with a conventional, NAPCO downloadab …
  • Global Fire Equipment

    Valkyrie Vox C

    (2 pages)
    TECHNICAL SPECIFICATIONSGLOBAL FIRE EQUIPMENT S.A.Sítio dos Barrabés, Armazém Nave Y, Caixa Postal 908-Z, 8150-016 São Brás de Alportel - PORTUGALTel: +351 289 896 560 • Sales: [email protected] • Technical Support: [email protected] • www.globalfire.ptValkyrie Vox CConventional Voice Sounder/BeaconORDER CODEDESCRIPTIONCONVENTIONAL VOICE …

Comments, Questions and Opinions: