  • Deltech PBA-12, Contents GENERAL SAFETY INFORMATION ...................................... 1 1.0 INSTALLATION ............................................................. 2 2.0 DESIGN LIMITATIONS ................................................... 2 3.0 OPERATION ................................................................. 3 4.0 MAINTENANCE ........................................................... 4 5.0 CARTRIDGE REPLACEMENT PROCEDURE ................... 5 6.0 GENERAL INFORMATION ..............................

  • Deltech PBA-12, 1 GENERAL SAFETY INFORMATION When properly installed and operated, the purifier is designed to purify ordinary compressed air to acceptable levels for supplied air breathing systems. Appropriate safety precautions must be observed to assure satisfactory service. Consult factory for assistance and recommendation if purifier performance does not meet design specifications or when its intended application is questionable. 1. LIMITATIONS ON USE OF SUPPLIED AIR RESPIRATORS This equipment is for use with supplied air respirators. Supplied air respirators should not be used in a hostile environment (highly toxic or oxygen-deficient) which is immediately dangerous to life, or where the

  • 2 1.0 INSTALLATION 1.1 Location See schematic drawing, Figure 1. The purifier is designed specifically to treat compressed air for supplied breathing air systems. To insure its functional operation, proper installation is vital. NOTE: Inlet and outlet isolation valves, drain and bleed valves should be kept in closed position at all times when purifier

  • Deltech PBA-12, 3 3.0 OPERATION A. The purifier, when installed properly and operated within its design limitations, will effectively purify compressed air at system pressure so that it can be utilized, after appropriate pressure reduction, with respirators, hoods and similar breathing apparatus. It will remove liquid and solid contaminants, odors and many toxic gases including carbon monoxide. (Traces of hydrogen sulfide, sulfur di- oxide, nitrogen dioxide, and miscellaneous organic gases [not methane]) Treated air purity either meets or exceeds OSHA standard for breathing air

  • Deltech PBA-12, 4 TABLE 3 Maximum Theoretical Life (MTL) in scf at various inlet pressure dew points and pressures. Inlet dew point (saturated air) temperature °F (°C) Inlet Pressure psig (kgf/cm 2 ) 20 (1.4) 40 (2.8) 60 (4.2) 80 (5.6) 100 (7.0) 150 (10.5) 200 (14.1) 40 (4) 50 (10) 60 (16) 6,798 4,644 3,230 10,716 7,321 5,091 14,634 9,998 6,953 18,552 12,675 8,814 22,470 15,352 10,676 32,265 22,044 15,330 42,060 28,736 19,984 70 (21) 80 (27) 2,281 1,634 3,596 2,575 4,911 3,517 6,226 4,458 7,541 5,400 10,828 7,754 14,116 10,108 90 (32) 100 (38) 1,186 872 1,869 1,375 2,552 1,876 3,236 2,380 3,919 2,883 5,627 4,140 7,336 5,397 4.0 MAINTENANCE

  • Deltech PBA-12, 5 5.0 CARTRIDGE REPLACEMENT PROCEDURE THE PURIFIER IS A PRESSURE CONTAINING DE- VICE. DEPRESSURIZE BEFORE REPLACING ANY CARTRIDGE. 5.1 Filter Cartridge No. 0713-2-1 1. Close inlet and outlet isolation ball valves. Depressurize the filter by slowly opening manual drain as shown. 2. Unscrew the metal collar holding the filter bowl to the head and remove the filter bowl and collar. Clean the filter bowl. 3. Unscrew the old filter cartridge and discard. Also discard the small o-ring that seals the filter cartridge top cap to the filter assembly head. 4. Insert small replacement o-ring on top of new replace- ment filter cartridge and screw replacement filter cartridge in

  • Deltech PBA-12, 6 1. Depressurize the purifier. 2. With indicator still installed, unscrew combination bleed and check valve assembly from indicator housing. 3. Remove lower gasket and old indicator cartridge. 4. Replace upper gasket and check to insure that it is prop- erly seated in housing. 5. Install new indicator cartridge in housing so that thinner band of colored granules (indicator gel) is at the top. 6. Insert new lower gasket. 7. Screw the combination bleed and check valve assembly back into indicator housing. 6.0 GENERAL INFORMATION 1. When the purifier is not in o

  • Deltech PBA-12, WARRANTY The manufacturer warrants the product manufactured by it, when properly installed, operated, applied, and maintained in accordance with procedures and recommendations outlined in manufacturer’s instruction manuals, to be free from defects in material or workmanship for a period as specified below, provided such defect is discovered and brought to the manufacturer’s attention within the aforesaid warranty period. The manufacturer will repair or replace any product or part determined to be defective by the manufacturer within the warranty period, provided such defect occurred in normal service and not as a result of misuse, abuse, neglect or accident. Normal

Related Products and Documents (Air Cleaner):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Chipset Communication UTV-100A1 Operation & user’s manual chipset-communication/utv-100a1-97V.pdf 02 Jan 2023 23
2 Philips FWM583 Specifications philips/fwm583-Y86.pdf 03 Mar 2024 2
3 Bad Cat Hot Cat Series Owner's manual bad-cat/hot-cat-series-119.pdf 02 Jan 2023 9
4 Craftsman 919.152390 Owner's manual craftsman/919-152390-49S.pdf 16 Jun 2023 40 1.65 Mb
5 Philips MX5800SA/22S Operation & user’s manual philips/mx5800sa-22s-32J.pdf 18 Nov 2022 47 1.83 Mb
6 Sima XL-SP-8 Operation & user’s manual sima/xl-sp-8-JJ4.pdf 30 Nov 2023 4 0.28 Mb

Similar Resources:

  • Philips

    AC3036/10

    (170 pages)
    1ABCDEF2AC3033AC3036© 2019 Koninklijke Philips N.V.All rights reserved.3000 038 71721EN User manual 1DA Brugervejledning 17DE Benutzerhandbuch 33ES Manual del usuario 51FI Käyttöopas 68FR Mode d’emploi 84IT Manuale utente 101NL Gebruiksaanwijzing 118NO Brukerhåndbok 136SV Användarhandbok 152 …
  • Bionaire

    EverFresh Air Exchange System BAP336

    (2 pages)
    EverFreshTMAir ExchangeSystemMODEL BAP336Read instructions before operating. Retain for future reference.Instruction LeafletINFO-LINE If after having read this leaflet, you have any questions or comments on air cleaner, call 1-800-253-2764 in North America.8. If it is a black washable filter, clean it as described in step 6.9. Remove the rubber Vacuum Plug …
  • Phoenix

    4031350

    (9 pages)
    Owner’s Manual — Phoenix Guardian RInstallation, Operation & Service Instructionswww.UsePhoenix.com • [email protected] 1-800-533-7533Read and Save These InstructionsThe Phoenix Guardian R HEPA System is the most compact, portable unit in our popular line of high performance airscrubbers. The Phoenix Guardian R features a 22” x 2 …
  • Precisionaire

    PrecisionCell II M

    (4 pages)
    1General:PrecisionCell II extended surface minipleat filtersnow offer the end user high efficiency filtration per-formance in minimal media pack depths of 4 inch-es deep in 60-65% (MERV 11), 80-85% (MERV13), and 90-95% (MERV 14-15), and are availablein a corrosion resistant metal frame (M) for boxstyle or optional metal frame with a single 13/16"heade …
  • GermAway

    201105

    (23 pages)
    Centurion High Occupancy 240 Watt Ultraviolet Air Sanitizer and Disinfection System Operation Manual SKU: 201105 The Centurion is a state of the art device utilizing a cross-flow filtration system and UV-C germicidal bulbs to catch and eradicate nearly all viral particles, germs, bacteria, and other contaminants from the air without risk of UV li …
  • Deltech

    PBA-12

    (11 pages)
    BREATHING AIR PURIFIERModel: PBA-12FORM NO.: 3227497 REVISION: 02/2012 READ AND UNDERSTAND THIS MANUAL PRIOR TO OPERATING OR SERVICING THIS PRODUCT.INSTRUCTION MANUAL …

Comments, Questions and Opinions: