  • intensity IF COMBO DI4738, TENSPros Caution: 1) Before applying the self-adhesive electrodes, it is recommended to wash and degrease the skin, and then dry it. 2) Do not turns on the device when the self-adhesive electrodes are not positioned on the body. 3) Never remove the self-adhesive electrodes from the skin while the device is still turns on. 4) It is recommended that, at minimum 1.5" x 1.5" self-adhering based, square electrodes are used at the treatment area 4.4.3 Electrode placement The placement of electrodes can be one of the most important parameters in achieving success with therapy. Of utmost importance is the willingness of the ph

  • intensity IF COMBO DI4738, TENSPros Table of Contents 1.SAFETY INFORMATIO 4 1.1 General description 1.2 Medical background 1.3 Indication for use 1.4 Contraindications 1.5 Warnings, Cautions, Adverse Reactions 2.PRESENTATION……… 2.1 Front and Rear panel 2.2 LCD display 3.SPECIFICATION 3.1 Accessories 3.2 Technical information 3.3 The waveforms of the stimulation programs 4.INSTRUCTION FOR U 4.1 Battery 4.2 Connect electrodes to lead wires 4.3 Connect lead wires to device 4.4 Electrodes

  • intensity IF COMBO DI4738, TENSPros 1. Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and land mobile radios, amateur radio, AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy. To assess the electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey should be considered. If the measured field strength in the location in which the device is used exceeds the applicable RF compliance level above, should be observed to verify normal oper

  • TENSPros 2. Presentation 2.1 Front and Rear Panel 1) Output socket: electric signal output after connection of the cable with adhesive electrodes channel 1. 2) Output socket: electric signal output after connection of the cable with adhesive electrodes channel 2. 3) Therapeutic mode selection (M). Stop the treatment. E

  • intensity IF COMBO DI4738, TENSPros 11. Glossary of Symbols Batch code……..01000001 Serial number……50000001 Attention: Read the operating instruction for use! Electrical devices are recyclable material and should not be disposed of with household waste after their useful life! Help us to protect the environment and save resources and take this device to the appropriate collection points. Please contact the organization which is responsible for waste disposal in your area if you have any questions. Type BF Applied Part 12. Warranty Please contact your dealer in case of a claim under the war

  • intensity IF COMBO DI4738, TENSPros 7. Troubleshooting If your device does not seem to be operating correctly, refer to the chart below to determine what may be wrong. Should none of these measures correct the problem, the device should be serviced. Problem Possible Cause Solution Display fails to light up Battery contact failure 1. Try fresh batteries. 2. Ensure batteries are inserted correctly. Check the following contacts: • All contacts are in place. • All contacts are not broken. Stimulation is weak Electrodes 1. Dried out or contaminated 2. Placement Lead w

  • intensity IF COMBO DI4738, TENSPros 6.3 electrodes 1) Use the device only with the leads and electrodes provided by the manufacturer. Use only the electrode placements and stimulation settings prescribed by your physician or therapist. 2) It is recommended that, at minimum, 1.5"X1.5" self-adhering square electrodes are used at the treatment area. 3) Inspect your electrodes before every use. Replace electrodes as needed. Reusable electrodes may cause slight skin irritation, lose adhesion and deliver less stimulation if overused. To use these electrodes: 1) Attach the electrode to the lead wire. 2) Rem

  • intensity IF COMBO DI4738, TENSPros 8. Storage 1) For a prolonged pause in treatment, store the device in a dry room and protect it against heat, sunshine and moisture. 2) Store the device in a cool, well-ventilated place 3) Never place any heavy objects on the device. 9. Disposal Used fully discharged batteries must be disposed of in a specially labeled collection container, at toxic waste collection points or through an electrical retailer. You are under legal obligation to dispose of batteries correctly. Please dispose of the devic

  • intensity IF COMBO DI4738, TENSPros This manual is valid for the InTENSity TM IF Combo TENS and IF Stimulator This user manual is published by Current Solutions™, LLC Current Solutions™, LLC does not guarantee its contents and reserves the right to improve and amend it at any time without prior notice. Amendments may however be published in new editions of this manual. All Rights Reserved. Rev. V1.1 © 2010 : United States Federal Law restricts this device to sale by or on the order of a physician or licensed practitioner

  • intensity IF COMBO DI4738, TENSPros Technical specifications for Transcutaneous Electrical Nerve Stimulator (TENS) mode Waveform Mono-phase square pulse wave Pulse amplitude Adjustable, 0~105mA peak at 1000 ohm Load each channel, 1mA/Step. Pulse Width Adjustable, from 50 to 300us microseconds, 10μS/step Pulse Rate Adjustable, from 1 to 150 Hz, 1 Hz/step Burst (P1) Burst rate: Adjustable, 0.5 ~ 5Hz; 0.1Hz/step Pulse width adjustable, 50~300μS Frequency fixed = 100 Hz Normal (P2) The pulse rate and pulse width are adjustable. It generates continuous stimulation based on the setting value. Pulse Width Modulation (P3) The pulse width is automatically varied in a cycle

  • intensity IF COMBO DI4738, TENSPros EXPLANATION OF IF Interferential Stimulation (IF) is an anti-inflammatory based treatment modality. Interferential stimulation is characterized by two alternating-current sine waves or square waves of differing frequencies that “work” together to produce an interferential current that is also known as a beat pulse or alternating modulation frequency. One of the two currents is usually held at 4,000 Hz, and the other can be held constant or varied over a range of 4,001 to 4,100 Hz. Because of the frequency,

  • intensity IF COMBO DI4738, TENSPros Guidance and- manufacturer’s declaration. Electromagnetic immunity The device is intended for use in. the electromagnetic environment specified below. The customer or the user should assure that it is used in such an environment. Immunity test IEC 60501 test level Complia nce level Electromagnetic environment - guidance Portable and mobile RF communications equipment should be used no closer to any part of the device, including cables, than the recommended separation distance calc

  • intensity IF COMBO DI4738, TENSPros 2) The wires provided with the system insert into the jack sockets located on top of the device. 3) Holding the insulated portion of the connector, push the plug end of the wire into one of the jacks (see drawing); one or two sets of wires may be used. 4) This device has two output receptacles controlled by Channel 1 and Channel 2 at the top of the unit. You may choose to use one channel with one pair of lead wires or both channels with two pairs of lead wires. Using both channels gives the user the advantage of stimulating two different areas at the same time. Caution: Do not

  • TENSPros P4 The pulse rate of the CH1 is fixed in 4000Hz; CH2 pulse rate is automatically varied in a cycle time. Interference frequency is increased from its original setting to 60% in setting cycle time, and then decreased from 60% to its original setting in nest setting cycle time. In this program, CH2 interference frequency (2 to 150Hz) and cycle time (5 to 30 sec)

  • TENSPros CAUTIONS: 1) Federal law (USA) restricts this device to sale by or on the order of a physician. 2) For single patient use only. 3) Keep yourself informed of the contraindications.

  • intensity IF COMBO DI4738, TENSPros 3. Specification 3.1 Accessories No DESCRIPTION Q’TY 1 Electrical stimulator device 1 piece 2 Electrodes Leads 2 pieces 3 1.5” x 1.5” Adhesive Electrodes 4 pieces 4 9V Alkaline Battery, type 6LR61 1 piece 5 Instruction Manual 1 piece 6 Carrying case 1 piece 7 AC Adaptor (optional) 1 piece 3.2 Technical information Channel Dual, isolated between channels Power supply 9.0 V Alkaline DC -1 *6LR61 battery Adapter output:9.0Vdc 800mA Operating conditions 5°C to 40°C (41℉ to 104℉)with a relative humidity of 30%-75%,atmospheric

  • TENSPros 1.5 Warnings, Cautions and Adverse Reactions WARNINGS: of a licensed physician. 2) The long-term effects of chronic electrical stimulation are unknown. Electrical stimulation devices do not have any curative value. 3) TENS is a symptomatic treatment and, as such, suppresses the sensation of pain, which would otherwise serve as a prot

  • intensity IF COMBO DI4738, TENSPros 4.7.2 IF Setting Press the [S] button to enter the setting state. The settings can be adjusted according to the following steps: 1) Set the Therapeutic Program There are 4 programs in IF therapeutic mode available. The therapeutic program can be selected by pressing the [▲] and [▼] button. The mode you selected will show up on the top of liquid crystal display. 2) Set Timer Press [S] button cycle to enter this setting. The treatment time is adjustable from 1 to 60 minutes or Continuous. Press [▲] or [▼] control to adjust setting. You can set the timer to “Continuou

  • intensity IF COMBO DI4738, TENSPros 6. Cleaning and Care 6.1 Tips for skin care To avoid skin irritation, especially if you have sensitive skin, follow these suggestions: 1) Wash the area of skin where you will be placing the electrodes, using mild soap and water before applying electrodes, and after taking them off. Be sure to rinse soap off thoroughly and dry skin well. 2) Excess hair may be clipped with scissors; do not shave stimulation area. 3) Wipe the area with the skin preparation your clinician has recommended. Let this dry. Apply electrodes as directed. 4) Many skin problems arise from the “pulling stress” from adhesive patches that

  • intensity IF COMBO DI4738, TENSPros Caution: Consult your physician for your suitable therapeutic mode 4.7 Steps to Set a New Program 4.7.1 TENS Setting Press the [S]button cycle to enter the setting state. The settings can be adjusted according to the following steps: 1) Set the Therapeutic Program There are 4 programs in TENS therapeutic mode available –Burst (P1), Normal (P2), Pulse Width Modulation (P3), and Pulse Rate Modulation (P4). The therapeutic program can be selected by pressing the [▲] and [▼] button. 2) Set Cycle Time (Optional) Cycle time is adjustable form 5 to 30 s

  • intensity IF COMBO DI4738, TENSPros Pulse Rate Modulation Interferential 4. Instruction for use 4 .1 Battery 4.1.1 Check/Replace the battery Over time, in order to ensure the functional safety of device, changing the battery is necessary. 1) Slide the battery compartment cover and open. 2) Insert the 9V battery into the battery compartment. 3) Make sure you are installing the battery properly. Be sure to match the positive and negative ends of the battery to the marking in the battery compartment of the device. 4) Press and pull down following the direction of the arrow indicated on the

Related Products and Documents (Medical Equipment):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Sony CDP-CA70ES - Compact Disc Player Operating instructions manual sony/cdp-ca70es-compact-disc-player-A7M.pdf 07 Aug 2022 43 2.86 Mb
2 Frigidaire FEB30S7FCB Circuit diagrams frigidaire/feb30s7fcb-Y4R.pdf 30 Aug 2023 1 0.11 Mb
3 HP D7171A - NetServer - LPr Manual  hp/d7171a-netserver-lpr-PSW.pdf 15 Jan 2024 51 1.03 Mb
4 Alcatel One Touch 818 Operation & user’s manual alcatel/one-touch-818-447.pdf 18 Dec 2023 52 5.72 Mb
5 TYAN Thunder h2000M S3992-E Notice tyan/thunder-h2000m-s3992-e-J76.pdf 20 Jun 2022 96 4.34 Mb
6 Princess CLASSIC GRILL CARRÉ User manual manual princess/classic-grill-carre-P83.pdf 30 Oct 2023 44

Similar Resources:

  • HEINE

    DELTA 20 T

    (6 pages)
    1Camera settings for photographic documentation with the HEINE DELTA® 20 T / HEINE DELTA® 20 PLUS / DELTA® 20 Dermatoscope and HEINE SLR Photo adaptorDigital high-resolution photography is the method of choice for optimum image documentation in dermatology. The combination of the DELTA® 20 T / DELTA® 20 Plus / DELTA® 20 and a di …
  • Pressalit Care

    R8468

    (19 pages)
    R8468R8478RB2290Nursing bench 2000 – Operation and maintenance manual enBruseplejebriks 2000 – Brugs- og vedligeholdelsesvejledning dkDusch- und Pflegeliege 2000 – Gebrauchs- und Pegeanleitung deTable de douche 2000 – Manuel d’utilisation et d‘entretien frVerpleegbank 2000 – Gebruiks- en onderhoudshandleiding nlDuschbrits 2000 – Bruks- oc …
  • Firefly

    Splashy

    (17 pages)
    User Manual For bath, play and getawaysFor French, Italian, Spanish, German, Portuguese, Polish and Swedish please refer to our website.www.reyfriends.com …
  • Beurer

    SL 40

    (148 pages)
    DE Anti-Schnarchgurt Gebrauchsanweisung .............................2EN Anti snore belt Instructions for use ............................... 20FR Ceinture anti-ronflements Mode d’emploi...................................... 38ES Cinturón antirronquidos Instrucciones de uso ............................ 56IT Cintura antirussamento Istruzio …
  • Richway & Fuji Bio

    Single Biomat

    (64 pages)
    DOCUMENT NO: RW-USM-001 (Ver. 3.0, Date: 2017.11.07)READ AND FOLLOW THE INSTRUCTIONS IN THIS MANUAL TO PREVENT PERSONAL HARM AND PROPERTY DAMAGE.VEUILLEZ LIRE ET SUIVRE LES INSTRUCTIONS QUI SE TROUVENT DANS CE MANUEL DANS LE BUT DE PRÉVERNIR LES DOMMAGES PERSONNELS ET À LA PROPRIÉTÉ.Manufacturer: Richway & Fuji Bio Inc.1314 S King St Suite 520, Honol …
  • Dräger

    Babylog VN500

    (4 pages)
    D-12377-2016Disassembly/Assembly MufflerOpen the flap by lifting the lower edge upwards.Close the flap.Pull the muffler as far it will go to the left.Push the muffler to the right into the socket.Remove the expiratory valve from the fitting.Turn the locking ring as far as possible to the left.Remove and empty the water trap container. Fit the muffler i …

Comments, Questions and Opinions: