Manualios.com

ION F-11 Operation & User’s Manual

ION F-11 Manual Online:

4.15, 2459 votes
ION F-11 User Manual
ION F-11 User Guide
ION F-11 Online Manual

Text of ION F-11 User Guide:

  • ION F-11, 1 IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS – This manual contains important instructions for models Aurora Vista 650 Australia / 1200 Australia / 2200 Australia that should be followed during installation and maintenance of the UPS and batteries. • This product is specially designed for PCs and it is not recommended for use in any medical equipment, life-supporting system and other specific important equipment. • Do not plug household appliances such as hair dryers, microwave ovens or vacuum c

  • ION F-11, 2 • In case smoke is found coming out from the device, please cut off the power supply quickly and contact the distributor. • The UPS contains one/two large-capacity batteries. So the shell shall not be opened, otherwise such dangers as electric shock will be caused. If any internal overhaul or replacement of the battery is required, please contact the distributor. • Servicing of batteries should be performed or supervised by personnel knowledgeable of batteries and the required precautions. Keep unauthorized personnel away from batteries. • A battery can presen

  • ION F-11, 3 1. Introduction Aurora Vista series is an intelligent and compact line interactive UPS (Uninterruptable Power Supply) which is designed to protect your personal computer or sensitive electronic equipments from all forms of power interference, including complete power failures. It is equipped with many features that allow any attached equipment to operate longer and more reliability. 2. Description of Features • Easy to use and install utilized microprocessor control to maximize the reliability and efficiency • Equipped with built-in boost and buck AVR function •

  • ION F-11, 4 4. Product Overview Front Panel 650 Australia 1200 Australia & 2200 Australia 1. Display When LCD starts to work, it will display all information for 3 seconds. When in normal mode, it will display as below. When in AVR mode, it will display as below. And the mark will flicker every 1second. When in battery mode, it will display as below. And the mark will flicker every 1second. Note: If I/P-V<40V input voltage will display “000” When in off charging mode, it will display as below. Note: the output vol

  • ION F-11, 5 2. Load level definition: Load level Load bar Indication 0%~25% 25%~50% 50%~75% 75%~100% 3. Battery capacity definition: 1B model battery definition: Battery Level Battery bar Indication Battery mode Other mode Battery voltage<11V Battery voltage<12.7V 11V≤battery voltage<11.5V 12.7V≤battery voltage<13.2V 11.5V≤battery voltage<12.5V 13.2V≤battery voltage<13.5V Battery voltage≥12.5V Battery voltage≥13.5V 2B model battery definition: Battery Level Battery bar Indication Battery mode Other mode Battery voltage<

  • ION F-11, 6 Back Panel: 650 Australia 1200 Australia 2200 Australia 1. AC input 2. 2*Australia outlet 3. RJ11 Modem/phone line protection 1. AC input 2. 4* Australia outlet 3. USB port 4. RJ45 LAN/Modem/phone line protection 5. Breaker

  • 7 5. Installation and Initial Startup Before installation, please inspect the unit. Be sure that nothing is damaged . I: Placement & Storage Conditions Install the UPS in a protected area that is free of excessive dust and has adequate air flow around the unit, and is free from excessive dust, corrosive fumes and conduct

  • 8 III: Connect the Loads Plug in the loads to output receptacles on the rear panel of the UPS. Simply turn on the power switch of UPS unit, and devices connected to the UPS will be protected by UPS unit. IV: Connect LAN cable, Modem or Phone line for Surge Protection Connect for example a single modem or phone line into surge-protected “IN” outlet on the back panel

  • 9 6. Functions & Operation I: DC Start Function DC Start Function enables UPS to be started up when AC utility power is not available and battery is fully charged. Just simply press the power switch to turn on the UPS. II: Green Power Function These series are equipped with Green Power Function for saving power and protecting battery. The feature of

  • ION F-11, 10 8. Maintenance I. General The UPS is virtually maintenance free: take care of proper environmental conditions and keep air inlets- outlets free of dust. II. Fuses If the AC input fuse is defect, be sure it is replaced by a compatible fuse from the same make and type. Never short circuit batteries. When working with batteries, remove watches, rings and other metal objects, and only use insulated tools. III. Batteries When replacing the batteries, use batteries with exa

  • ION F-11, 11 10. Specifications Model 650 Australia 1200 Australia 2200 Australia CAPACITY 650VA / 360W 1200VA/600W 2200VA/1200W INPUT Voltage 230 VAC Voltage Range 170~280 VAC OUTPUT Voltage 230VAC Voltage Regulation +/-10% (Battery mode) Frequency Range 50/60Hz Frequency Regulation ±1Hz (Battery mode) Transfer Time Typical 4-8ms Waveform Modified Sine Wave PROTECTION Full protection Deep discharge, overcharge and overload protection ENVIRONMENT Humidity 0-90 % RH @ 0° to 40° C (non-condensing) Noise Level Less than 40dB 45dB Software Mo

Related Products and Documents (UPS):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 AMERICANA 16 Owner's manual and installation instructions americana/16-ZO3.pdf 09 Feb 2023 40
2 Silver King SKDI Supplementary manual silver-king/skdi-G1H.pdf 06 Jul 2023 12 0.36 Mb
3 iQe COMFORT 30 Installation and servicing instructions iqe/comfort-30-RD6.pdf 06 Jan 2023 48
4 HP Z420 Series Specification hp/z420-series-1Z9.pdf 19 Feb 2023 72
5 Albrecht DR601 Operation & user’s manual albrecht/dr601-GT3.pdf 17 Oct 2022 11 0.39 Mb
6 ELR Engeineering NGG16 Garratt Owner's manual elr-engeineering/ngg16-garratt-MW6.pdf 14 Nov 2022 8

Similar Resources:

  • Atlantis Land

    Line Interactive UPS A03-PS651 _MX01

    (50 pages)
    Where solutions begin ISO 9001:2000 Certified Company OnePower Line Interactive UPS A03-PS651 [650VA/375W] MANUAL A03-PS651 _MX01 …
  • Eaton

    93PM-L

    (82 pages)
    p/n: P-164000764Revision 01160kW (208V) 4–Wire IAC-B200kW (208V) 4–Wire IAC-BInstallation and Operation ManualEaton® 93PM-L Integrated Accessory Cabinet - Bypass …
  • Next

    Mantis RT 1100VA

    (20 pages)
    www.nextups.eu Line Interactive Sinewave UPS MANTIS 1100 RT / MANTIS 1500 RT / MANTIS 2000 RT / MANTIS 3000 RT Uninterruptible Power Supply System User Manual …
  • Tripp Lite

    SmartPro Rackmount SMX500RT1U

    (5 pages)
    Tripp Lite1111 West 35th StreetChicago, IL 60609 USATelephone: +(773) 869 1234E-mail: [email protected] #: SMX500RT1USmartPro .5kVA Line Interactive UPS, SNMPWEBCARD option, 1U Rack/Tower, USB, Serial, EPO, 230V Highlights500VA line interactive 1U rack/tower UPS230V nominal output during brownouts to 187V and overvoltages to 252VUSB, RS232, EPO a …
  • Power Walker

    VFI 10000CP 3/3

    (230 pages)
    EN Online UPS PowerWalker VFI 10000CP 3/3 PowerWalker VFI 10000CP 3/3L PowerWalker VFI 15000CP 3/3 PowerWalker VFI 15000CP 3/3L PowerWalker VFI 20000CP 3/3 PowerWalker VFI 20000CP 3/3L PowerWalker VFI 30000CP 3/3 PowerWalker VFI 30000CP 3/3L Manual EN, DE, ES, IT, PT, PL Uninterruptible Power Supply System …
  • CyberPower

    OR1500LCDRTXL2U

    (2 pages)
    OR1500LCDRTXL2U OR2200LCDRTXL2U User’s Manual K01-0000075-00 (SAVE THESE INSTRUCTIONS) This manual contains important safety instructions. Please read and follow all instructions carefully during installation and operation of the unit. Read this manual thoroughly before attempting to unpack, install, or operate your UPS. CAUTION! To prevent th …

Comments, Questions and Opinions: