Manualios.com

Lumel KD7 Operation & User’s Manual

Lumel KD7 Manual Online:

3.25, 2258 votes
Lumel KD7 User Manual
Lumel KD7 User Guide
Lumel KD7 Online Manual

Text of Lumel KD7 User Guide:

  • Lumel KD7, 64 • Save data on CF: The forced storage of the newest group data from the buffer to the CF card follows at the moment of changing the input state of the selected logic channel from 0 (OFF) to 1 (ON) Æ transition from the negative output value to the positive output value, see the Note below. • Create new file: The forced creation of a new file with group data follows at the moment of changing the logic state of the selected channel, from 0 OFF) into 1 (ON) Æ transition from the negative output value to the positive output value, see

  • Lumel KD7, 61 8.1.4 Visualization of the CF card state on the screen - Lack of CF card in the recorder - The CF card is inserted in the recorder - Exceeding of the 90% recording level of the CF card capacity 8.1.5 Review and erasing of files from the CF card After selecting the o icon in the KD7 Control Panel window, names of files stored on the CF memory card are displayed in the Files Browser window. After selecting the given file and confirming the selection, this file is deleted from the CF card. Lack of CF card in the recorder Index of C

  • Lumel KD7, 35 7.10.2 Menu of logic channel programming Logic channel Selection : Ch1 ... Ch32 / Copy to: copying of settings into the selected channel General Input type: AI1-Analog input ,0-10V Selection: Disabled / Analog inputs, Modbus Master inputs, Mathem. functions, Binary inputs, Alarms as inputs. Menu of the selected input Configuration:

  • Lumel KD7, 98 7. Window informing about the successfull end of the installation. 9.1.3 Program service • Main application window The view of the main application window when the KD7 recorder is not connected (through the USB interface) to the PC computer, informs about this message in the information window and blanked icons on the toolbar View on the main application window with the connected KD7 recorder to the PC.

  • Lumel KD7, 99 • Toolbar The application toolbar is situated on the upper part of the window and has the following appearance: This toolbar allows to a quick access to the most important program options. Explanations of symbols are given below. Call of the collection option of marked files from the recorder into the PC computer. Upload the file from the PC computer into the CompactFlash installed in the recorder. Renewed collection of basic data from the recorder (systemic information and the list of files). Removal of marked files from the CompactFlash card installed in the recorder. Storage of all current measuring data

  • Lumel KD7, 48 Mathematical and logic operators: Operator Function Description + x + y Addition - x – y Subtraction * x * y Multiplication / x / y Division ^ x ^ y Raising to a power - -x Negation of the number sign % x %y Modulo, returns the fractional part of the division operation x/y > x > y Logic operator higher than. Returns 1 if true and 0 if false < x < y Logic operator smaller than. Returns 1 if true and 0 if false >= x >= y Logic operator higher or equal. Returns 1 if true and 0 if false <= x <= y Logic operator smaller or equal. Returns 1 if true and 0 if false != x != y Different logic operator. Returns

  • Lumel KD7, 70 8.2.5 Analog view of the channel group The set area of the Min type alarm is marked in blue colour on the analog indicator. Index of the set alarm of Max type Alarm in the channel Alarm in the recorder Index of the alarm of Min/Max type set beyond the output range of the logic channel. Binary type of signal: 1 (ON) / 0 (OFF) Communication error. (Interface input) Sensor break (Temperat. measurement) Index of the minimum type alarm le

  • Lumel KD7, 46 After the edition, write the description and the output function range. It should be determined at least in the area of its variability. Next, write the name and channel description in, and set output parameters of the logic channel ( for which the function is the signal source): description, output range of the logic channel, signal type, precision, unit. One can set the signal type as analog or binary. Selection of analog signal type means, that the signal of this output will be treated as continuous and the logic c

  • Lumel KD7, 11 One can upload data stored on the CF card to a PC and record or erase files on the CF card through the USB interface. To connect the computer to the recorder through USB socket, use delivered in standard accessories, the shielded USB AM-BM cable of 1.8 m long or another similar one of 5 m long ( the USB bus operates correctly without amplification at the distance up to 5 m). In order that the KD7 recorder was seen in a PC with MS Windows operating system and serviced through USB, one must install drivers and the KD Connect program from the delivered CDR being in

  • Lumel KD7, 90 Any analog output value of the logic channel higher than zero, will be interpreted as the logic state 1 (ON) of the given channel. 8.7 Edition of recorder users After selecting the security icon in the KD7 Control Panel, one can set up parameters for individual recorder users in the Editing user window. In KD7, 1...8 users can have

  • Lumel KD7, 54 - Select the Totalizer type (Integral or Counter) - After choosing the Unit and events menu in the open window Totalizer units and events select the option Enabled for the Record to the log menu.

  • Lumel KD7, 83 • storage in the log Disabled / Enabled – storage of alarm messages in alarmowych Alarm log. 8.5.3. Programming Totalizer parameters (Counter/Integral) Choose the type of programmed function in the Totalizer tab ( see section 8.3): Disabled, Integral or Counter ▪ After selecting the type: Counter, one must set following groups of parameters: - Unit and events - Numeric settings - Time settings - Alarm settings → In the window of parameters group

  • 85 • When choosing the type: Integral, one must set following groups of parameters: - Unit and events - Numeric settings - Time settings - Alarm settings Æ In the window of parameters “Totalizer units and events” following parameters are programmed: Unit: select defined units or program the own unit. Record to

  • Lumel KD7, 92 The archive service concerns only data stored in the recorder buffer till the entry moment in the function of their review. During the archive review, current measuring data are stored in the buffer and will be serviced at the renewed entry into the archive. After changing the recorder configuration, all archive data stored in the memory buffer are erased. If they are necessary, one must rewrite them previously on the CF memory card, (see section 8.1.6.)

  • Lumel KD7, 71 The set area of the Max type alarm is marked in red color on the analog indicator. 8.2.6 Statistic view of channel group On the statistic screen following values are displayed: minimal and maximal values of the measured signal in the current session period of the recorder operation, mean values, current signal value, is signaled and the messages about the range overflow, sensor break, current alarm state, messages about the range overflow and sensor breaks, the alarm state in the recorder and the given measuring channel is also signaled. Overflow of Max range Max alarm range

  • 112 After sending an update file on the CF card the update progress appears. If system update finishes and device resets with success the main page will be displayed. 9.5.7 FTP Download Application The FTP Download is an application to automate a download process of data files from a device to PC. It can be easily used in batch files (*.bat) to periodically c

  • Lumel KD7, 3 7.11.2 Programming of event logs……………………………………………………………… 53 7.12 Edition of operator messages………………………………………………………….. 55 7.13 Exit from the recorder configuration……………..………………………………..……. 57 8. SELECTED ELEMENTS OF THE RECORDER CURRENT SERVICE.................. 58 8.1 CompactFlash memory card ……...................................................................……. 58 8.1.1 Information about the CF memory card.................................................................... 58 8.1.2 Formatting the CF card......................

  • Lumel KD7, 57 7.13 Exit from the recorder configuration After finishing the recorder configuration, one must close KD7 Control Panel. After pressing the output button from the configuration, the window to select the option of the configuration file storage selection is open: - After selecting the Save and set configuration button. - When simultaneously the Export to file option is marked, the configuration file will be stored in the recorder

  • 36 Alarm log: enabled Selection: On/Off – storage of the alarm in the log file Totalizer Type: Integral Selection: Disabled, Integral, Counter Units and events V, Lack, Lack Selection and edition: Unit, To

  • Lumel KD7, 106 - On the PC computer side a. Start the KD7 Setup program, call the context menu (tap on the area of the recorder screen), and next press the input icon in order to configure the recorder. b. The logging dialogue appears. One must transit into the configuration dialogue. c. At the first configuration, one can select the only available the option Open configuration from file. The standard dialogue of the Windows system appears to open files. One must select the previously saved configuration file. d. After reading the configuration file in, the transition to the KD7 Control Panel follow

  • Lumel KD7, 14 Two-wire connection: - Resistance thermometer RTD - Resistance transmitter Note: the balancing resistance R should have a resistance equal to the total resistance of both connecting wires of RTD and transmitter with terminals Three-wire connection: - Resistance thermometer RTD - Resistance transmitter - Potentiometric transmitter

  • 108 Information about the block in which we state discordance of the digital signature with saved date Check result: Wrong verification of the file. 9.4. KD Archive program The KD Archive program is destined for visualization and analysis of archived measuring data stored in binary format in the CF card. The softwa

More Instructions:

DOWNLOAD

Related Products and Documents (Voice Recorder):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Sony DCR-IP1 Service manual sony/dcr-ip1-ATF.pdf 22 Feb 2023 82
2 Navitar 1-51200 Dimensional drawing navitar/1-51200-NBS.pdf 20 Oct 2022 1
3 Dell C5517H Operation & user’s manual dell/c5517h-7PX.pdf 30 Jan 2023 1
4 Lumapower MRV-SideKick Ultra 3 PLUS Operation & user’s manual lumapower/mrv-sidekick-ultra-3-plus-43W.pdf 02 Aug 2023 2
5 Alcatel ONE TOUCH 535 Operation & user’s manual alcatel/one-touch-535-884.pdf 27 Sep 2023 49 6.07 Mb
6 Frontier 67026 Operation & user’s manual frontier/67026-C74.pdf 13 Nov 2023 2

Similar Resources:

  • Sony

    4-166-309-11(1)

    (96 pages)
    ICD-PX8204-166-309-11(1)E:\Voce-P\4166309111\4166309111ICDPX820CE7\01GB-ICDPX820CE7\010COV.fmMaster: Cover_Right4-166-309-11(1)© 2010 Sony CorporationIC RecorderOperating InstructionsICD-PX820Getting StartedBasic OperationsOther Recording OperationsOther Playback OperationsEditing MessagesAbout the Menu FunctionUtilizing Your ComputerAdditional InformationT …
  • Telesystems

    EDIC-mini Tiny 16 A52

    (8 pages)
    Short Operating Instruction for Digital Recorder EDIC-mini Tiny 16 A52 - 300h/600h/1200hOverlookMiniature digital Recorder EDIC-mini Tiny 16 A52 is a professional device intended for making high quality record of voice messages into a built-in ash memory. The recordings can be further uploaded onto the PC. The Recorder can be used as a ash medi …
  • EDIC-mini

    TINY A27 1120

    (8 pages)
    1EDIC-mini TINYModel A271120/2240/4480/8960/17920/35840Characteristics- Wooden case;- Dimensions: 130x110x35 mm;- Weight: < 200 g;- Operating temperature range: 0…+40 ˚C (32…+104 ˚F);- Recording mode: mono;- Recording duration: 600 hours;- Built-in microphone’s operating distance: 7-9 meters (21-27 ft);- Battery life in record mode (sampl …
  • Sony

    ICD-P330F - Ic Recorder

    (26 pages)
    SERVICE MANUALSony CorporationConnect Business DivisionPublished by Sony Techno Create CorporationUS ModelAEP ModelE ModelIC RECORDER9-887-143-012006B04-1© 2006.02Ver. 1.0 2006.02SPECIFICATIONSICD-P330FIC recorder sectionRecording media Built-in flash memory 64 MB,Monaural recordingRecording time HQ: 7 hours 20 minutesSP: 19 hours 35 minutesLP: 32 hours 10 …
  • VRSLT

    Voice Recorder

    (5 pages)
    VRSLT: Long Duration Voice Recorder VRSLT THANK YOU FOR PURCHASING THE VRSLT: LONG DURATION VOICE RECORDER Please read this manual before operating the VRSLT: Long Duration Voice Recorder and keep it handy. The VRSLT is our newest and longest lasting voice recorder! With a battery life of up to 15 days in voice activation mode, this recorder can be l …
  • Grundig

    GV 470 S VPT

    (210 pages)
    AV/CVTRACKINGPROGRAM2 31548 970SAT6EW/EDSET;OKCLCHECKAUTOpo:ÇHIFICOUNT0000LP*8VRECORDON/OFFTIMERS-VHSTVAV8op+–PROGRAMeRP 35VIDEO 1VIDEO 2ATSSTOPPPAL/SECCODEPICTUREOKTIP VPT INFO)#<34wqRP35Service ManualÄnderungen vorbehalten Printed in Germany Service Manual Sach-Nr. 72010-517.10Subject to alteration VK 222 0794 Service Manual Part No. 72010-51 …

Comments, Questions and Opinions: