Grafenthal PR-1000 Operation & User’s Manual

Grafenthal PR-1000 Manual Online:

4.65, 1823 votes
Grafenthal PR-1000 User Manual
Grafenthal PR-1000 User Guide
Grafenthal PR-1000 Online Manual

Text of Grafenthal PR-1000 User Guide:

  • Grafenthal PR-1000, GRAFENTHAL GmbH - User Manual UPS PR-1000/-1500/-2000/-3000 - 1 - TABLE OF CONTENTS 1. Important Safety Warning…………………………………………………………………………. 2 1-1. Transportation………………………………………………………………………………... 2 1-2. Preparation…………………………………………………………………………………… 2 1-3. Installation……………………………………………………………………………………. 2 1-4. Operation…………�

  • Grafenthal PR-1000, GRAFENTHAL GmbH - User Manual UPS PR-1000/-1500/-2000/-3000 - 2 - 1. IMPORTANT SAFETY WARNING Please comply with all warnings and operating instructions in this manual strictly. Save this manual properly and read carefully the following instructions before installing the unit. Do not operate this unit before reading through all safety information and operating instructions carefully 1-1. Transportation › Please transport the UPS system only in the original package to protect against shock and impact. 1-2. Preparation › Co

  • Grafenthal PR-1000, GRAFENTHAL GmbH - User Manual UPS PR-1000/-1500/-2000/-3000 - 3 - 1-5. Maintenance, service and faults › The UPS system operates with hazardous voltages. Repairs may be carried out only by qualified maintenance personnel. › Caution - risk of electric shock. Even after the unit is disconnected from the mains (building wiring outlet), components inside the UPS system are still connected to the battery and electrically live and dangerous. › Before carrying out any kind of service and/or maintenance, disconnect the batteries and verify that no current is present and no hazardous vol

  • Grafenthal PR-1000, GRAFENTHAL GmbH - User Manual UPS PR-1000/-1500/-2000/-3000 - 4 - 2. INSTALLATION AND SETUP NOTE: Before installation, please inspect the unit. Be sure that nothing inside the package is damaged. Please keep the original package in a safe place for future use. NOTE: There are two different types of online UPS: standard and long-run models. Please refer to the following model table. Model Type Model Type PR-1000 Standard PR-1000L Long-run PR-1500 PR-1500L PR-2000 PR-2000L PR-3000 PR-3000L 2-1. Rea

  • Grafenthal PR-1000, GRAFENTHAL GmbH - User Manual UPS PR-1000/-1500/-2000/-3000 - 5 - 2-2. Setup the UPS Step 1: UPS input connection Plug the UPS into a two-pole, three-wire, grounded receptacle only. Avoid using extension cords.  For 208/220/230/240VAC models: The power cord is supplied in the UPS package.  For 110/115/120/127VAC models: The power cord is attached to the UPS. The input plug is a NEMA 5-15P for 1000, 1000L, 1500 and 1500L models, NEMA 5-20P for 2000 and 2000L models. Note: For

  • Grafenthal PR-1000, GRAFENTHAL GmbH - User Manual UPS PR-1000/-1500/-2000/-3000 - 6 - Step 5: Disable and enable EPO function Keep the pin 1 and pin 2 closed for UPS normal operation. To activate EPO function, cut the wire between pin 1 and pin 2. Step 6: Turn on the UPS Press the ON/Mute button on the front panel for two seconds to power on the UPS. Note: The battery charges fully during the first five hours of normal operation. Do not expect full battery run capability during this initial charge period. Step 7: Install software For optimal computer system protection, install UPS monitoring software to fully configure

  • GRAFENTHAL GmbH - User Manual UPS PR-1000/-1500/-2000/-3000 - 7 - 3. OPERATIONS 3-1. Button operation Button Function ON/Mute Button  Turn on the UPS: Press and hold ON/Mute button for at least 2 seconds to turn on the UPS.  Mute the alarm: When the UPS is on battery mode, press and hold this button for at least 5 seconds to disable or

  • Grafenthal PR-1000, GRAFENTHAL GmbH - User Manual UPS PR-1000/-1500/-2000/-3000 - 8 - Display Function Backup time information Indicates the backup time in pie chart. Indicates the backup time in numbers. H: hours, M: minute, S: second Fault information Indicates that the warning and fault occurs. Indicates the warning and fault codes, and the codes are listed in details in 3-5 section. Mute operation Indicates that the UPS alarm is disabled. Output & Battery voltage information Indicates the output voltage, frequency or battery voltage. Vac: output voltage, Vdc: battery voltage, Hz: frequency Load information Indica

  • Grafenthal PR-1000, GRAFENTHAL GmbH - User Manual UPS PR-1000/-1500/-2000/-3000 - 9 - 3-3. Audible Alarm Battery Mode Sounding every 4 seconds Low Battery Sounding every second Overload Sounding twice every second Fault Continuously sounding Bypass Mode Sounding every 10 seconds 3-4. LCD display wordings index Abbreviation Display content Meaning ENA Enable DIS Disable ESC Escape HLS High loss LLS Low loss BAT Battery CF C

  • GRAFENTHAL GmbH - User Manual UPS PR-1000/-1500/-2000/-3000 - 10 -  01: Output voltage setting Interface Setting Parameter 3: Output voltage For 208/220/230/240 VAC models, you may choose the following output voltage: 208: presents output voltage is 208Vac 220: presents output voltage is 220Vac 230: presents output voltage is 230Vac 240: prese

  • Grafenthal PR-1000, GRAFENTHAL GmbH - User Manual UPS PR-1000/-1500/-2000/-3000 - 11 -  05: ECO voltage range setting Interface Setting Parameter 2 & 3: Set the acceptable high voltage point and low voltage point for ECO mode by pressing Down key or Up key. HLS: High loss voltage in ECO mode in parameter 2. For 208/220/230/240 VAC models, the setting range in parameter 3 is from +7V to +24V of the nominal voltage. For 110/115/120/127 VAC models, the setting range in parameter 3 is from +3V to +12V of the nominal voltage. LLS: Low loss voltage in ECO mode in parameter 2. For

  • Grafenthal PR-1000, GRAFENTHAL GmbH - User Manual UPS PR-1000/-1500/-2000/-3000 - 12 -  09: Programmable outlets setting Interface Setting Parameter 3: Set up backup time limits for programmable outlets. 0-999: setting the backup time limits in minutes from 0-999 for programmable outlets which connect to non-critical devices on battery mode.  00: Exit setting

  • Grafenthal PR-1000, GRAFENTHAL GmbH - User Manual UPS PR-1000/-1500/-2000/-3000 - 13 - 3-6. Operating Mode Description Operating mode Description LCD display Online mode When the input voltage is within acceptable range, UPS will provide pure and stable AC power to output. The UPS will also charge the battery at online mode. ECO mode Energy saving mode: When the input voltage is within voltage regulation range, UPS will bypass voltage to output for energy saving. Frequency Converter mode When input frequency is within 40 Hz to 70 Hz, the UPS can

  • Grafenthal PR-1000, GRAFENTHAL GmbH - User Manual UPS PR-1000/-1500/-2000/-3000 - 14 - 3-7. Faults Reference Code Fault event Fault code Icon Fault event Fault code Icon Bus start fail 01 x Inverter voltage Low 13 x Bus over 02 x Inverter output short 14 Bus under 03 x Battery voltage too high 27 Bus unbalance 04 x Battery voltage too low 28 Inverter soft start fail 11 x Over temperature 41 x Inverter voltage high 12 x Over load 43 3-8. Warning indicator Warning Icon (flashing) Alarm

  • Grafenthal PR-1000, GRAFENTHAL GmbH - User Manual UPS PR-1000/-1500/-2000/-3000 - 15 - 4. TROUBLESHOOTING If the UPS system does not operate correctly, please solve the problem by using the table below. Symptom Possible cause Remedy No indication and alarm even though the mains is normal. The AC input power is not connected well. Check if input power cord firmly connected to the mains. The AC input is connected to the UPS output. Plug AC input power cord to AC input correctly. The icon and the warning

  • Grafenthal PR-1000, GRAFENTHAL GmbH - User Manual UPS PR-1000/-1500/-2000/-3000 - 16 - Symptom Possible cause Remedy Fault code is shown as 14 and the icon is lighting on LCD display and alarm is continuously sounding. The UPS shut down automatically because short circuit occurs on the UPS output. Check output wiring and if connected devices are in short circuit status. Fault code is shown as 1, 2, 3, 4, 11, 12, 13 and 41 on LCD display and alarm is continuously sounding. A UPS internal fault has occurred. There are two possible results: 1. The load is still supplied, but directly from AC power via bypass. 2. The load

  • GRAFENTHAL GmbH - User Manual UPS PR-1000/-1500/-2000/-3000 - 17 - 5. STORAGE AND MAINTENANCE Operation The UPS system contains no user-serviceable parts. If the battery service life (3~5 years at 25°C ambient temperature) has been exceeded, the batteries must be replaced. In this case, please contact your dealer. Storage Befo

  • Grafenthal PR-1000, GRAFENTHAL GmbH - User Manual UPS PR-1000/-1500/-2000/-3000 - 18 - 6. SPECIFICATIONS MODEL PR-1000 PR-1500 PR-2000 PR-3000 Capacity* 1000 VA / 800 W 1500 VA / 1200 W 2000 VA / 1600 W 3000 VA / 2400 W Input Voltage Range Low Line Transfer 160 VAC / 140 VAC / 120 VAC / 110 VAC ± 5 % or 80 VAC / 70 VAC / 60 VAC / 50 VAC ± 5 % ( based on load percentage 100% - 80 % / 80 % - 70 % / 70 - 60 % / 60 % - 0) Low Line Comeback 175 VAC ± 5 % or 85 VAC ± 5 % High Line Transfer 300 VAC ± 5 % or 150 VAC ± 5 % High Line Comeback 290 VAC ± 5 % or 145 VAC ± 5 % Frequency Range 40Hz ~ 70 Hz Phase Single phase with gr

Related Products and Documents (UPS):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 EKF PC1-62-GROOVE Operation & user’s manual ekf/pc1-62-groove-76O.pdf 25 Mar 2024 84
2 IBM 37L1388 Operation & user’s manual ibm/37l1388-14M.pdf 10 Apr 2024 62
3 Whirlpool GI15NDXZQ0 Installation instructions manual whirlpool/gi15ndxzq0-RQI.pdf 24 Apr 2023 24
4 JMR electronics Fortra 5251F6 Installation manual jmr-electronics/fortra-5251f6-J2I.pdf 14 Feb 2023 30
5 Electron-Sky CZH-05A Operation & user’s manual electron-sky/czh-05a-8T4.pdf 04 Jul 2023 6
6 Moffat B30 Technical data sheet moffat/b30-RWJ.pdf 11 Sep 2022 2

Similar Resources:

  • CyberPower

    PFC Sinewave Series

    (2 pages)
    OR750PFCLCD OR1000/1500PFCLCD OR750PFCLCD / OR1000PFCLCD / OR1500PFCLCD User Manual K01-0000408-00 (SAVE THESE INSTRUCTIONS) This manual contains important safety instructions. Please read and follow all instructions carefully during installation and operation of the unit. Read this manual thoroughly before attempting to unpack, install, or oper …
  • Dell

    Online Rack UPS 3750W

    (202 pages)
    Dellt Online Rack UPS3750W and 4200WGetting Started WithYour SystemDémarrarer avec Votre SystèmeErste Schritte Mit Ihrem SystemНачало работы c вашей системойInicio de su sistema系统使用 入门指南系統使用 入門指南사용자의 시스템 시작하기はじめに システムについてK804N, H952N, J730N, K805NJ739Nwww …
  • CyberPower

    PR750LCDRTXL2U

    (2 pages)
    The LCD display indicates a variety of UPS operational conditions. All descriptions apply when the UPS is plugged into the AC outlet and turned on or when the UPS is on battery. 10. Serial Port I Serial port allows connection and communication between the UPS and the computer. 11. Serial Port II Serial Port II relays information to equipm …
  • Eaton

    Powerware 5125

    (42 pages)
    Powerware 5125 (9910-P33) EBMInstallation Guide for IBM ApplicationsGuide d’Installation EBM pour Applications IBMEBM Installationsanleitung für IBM-AnwendungenGuida all’Installazione dell’EBM per le Applicazioni IBMGuía de Instalación del EBM para Aplicaciones de IBM®® …
  • Bay Networks

    UPS45

    (8 pages)
    990-7076 Revision 1 10/98Designed By BayStack UPS45 Quick Reference Guide English204459-AAbout Your New BayStack UPS45This Uninterruptible Power Supply (UPS) is designed to preventblackouts, brownouts, sags and surges from reaching yourcomputer and other valuable electronic equipment. This UPSalso filters out small utility line fluctuations and isolates you …
  • Falcon

    SG2K-X1T

    (24 pages)
    OWNER'SOPERATINGMANUALIsolated Uninterruptible Power Supply Models:SG2K-X1TSG2K-X2TSG3K-X1TSG3K-X2TDetailed SG Series product specifications are available in PDF format at www.falconups.com®2006 Falcon®Electric Inc. All rights reserved.All other brand names and trademarks are the property of their respective owners.The information stated in this docum …

Comments, Questions and Opinions: