Manualios.com

Alfa Laval Alfa-V ACV Series Instruction Manual

Alfa Laval Alfa-V ACV Series Manual Online:

4.4, 1981 votes
Alfa Laval Alfa-V ACV Series User Manual
Alfa Laval Alfa-V ACV Series User Guide
Alfa Laval Alfa-V ACV Series Online Manual

Text of Alfa Laval Alfa-V ACV Series User Guide:

  • ORIGINAL INSTRUCTIONS AHE00052EN 1904 Alfa Laval Alfa-V ACV/ANV/VXD Instruction manual • Product description • Product labels • Transport & lifting • Installation • Maintenance • Spare parts

  • Alfa Laval Alfa-V ACV Series, AHE00052EN 1904 2 Alfa Laval is a trademark registered and owned by Alfa Laval Corporate AB. Alfa Laval reserves the right to change specification without prior notification. Index 1. Important information 1.1 Disclaimer...................................................................................................................................3 1.2 Intended use...............................................................................................................................3 1.3 Where to nd product information ..............................................................................................3 2. Product description 2.1 General info

  • AHE00052EN 1904 3 Alfa Laval is a trademark registered and owned by Alfa Laval Corporate AB. Alfa Laval reserves the right to change specification without prior notification. 1 Important information 1.1 Disclaimer This Instruction Manual applies to all Alfa Laval Alfa-V industrial condensers and gas coolers and is supplied in combination with the Alfa Laval Air Cooled C

  • Alfa Laval Alfa-V ACV Series, AHE00052EN 1904 4 Alfa Laval is a trademark registered and owned by Alfa Laval Corporate AB. Alfa Laval reserves the right to change specification without prior notification. 2 Product description 2.1 General information and application The Alfa Laval Alfa-V series is a wide range of heavy duty dual fan row V-type condensers and gas coolers for air conditioning and refrigeration applications. Alfa-V air-cooled condensers and gas coolers provide high capacities at a modest footprint. • Refrigerants: all halocarbon (ACV), ammonia (ANV) or CO 2 (VXD) • Capacity range ACV: 115 up to 1850 kW

  • Alfa Laval Alfa-V ACV Series, AHE00052EN 1904 5 Alfa Laval is a trademark registered and owned by Alfa Laval Corporate AB. Alfa Laval reserves the right to change specification without prior notification. • Electrical options: - Switch on/off (SW) - EC Motors wired to a common terminal box (CBP= parallel config. CBM= master/slave config.) - Switchboard IP55 (B) - AC Fan step control cabinet (BS/BST) - EC fan speed control cabinet (ICM) - Basic EC switchboard panel (ECCB) 2.4 Code description ACV S(E) 90 4 .1 - B D SK * - A

  • Alfa Laval Alfa-V ACV Series, AHE00052EN 1904 6 Alfa Laval is a trademark registered and owned by Alfa Laval Corporate AB. Alfa Laval reserves the right to change specification without prior notification. 3. Product label Model Refer to paragraph "Code description" Item ID Serial no. Communicate these when ordering spare parts as they identify the unit O. A. Order Acknowledgement number Unit Net Weight Check before any lifting operation to ensure that proper lifting tools are used WARNING READ INSTRUCTION MANUAL BEFORE INSTALLATION AND MAINTENANCE TO AVOID INJURIES OR DAMAGE Manufacturer Manuf. Date AIR HEX ALONTE S.R.L. - Italy 04 / 2019 Model O.A. **********

  • Alfa Laval Alfa-V ACV Series, AHE00052EN 1904 7 Alfa Laval is a trademark registered and owned by Alfa Laval Corporate AB. Alfa Laval reserves the right to change specification without prior notification. 5. Fan direction Sticker indicates fan rotation direction 10. Lifting lug Use all marked lifing lugs when lifting from above. 6. Electrical warning Electrically powered component. Switch off power supply before any maintenance or instal- lation activity. Spare part item no 9460088799 8. Fan motor Fan motor item number. 1

  • Alfa Laval Alfa-V ACV Series, AHE00052EN 1904 8 Alfa Laval is a trademark registered and owned by Alfa Laval Corporate AB. Alfa Laval reserves the right to change specification without prior notification. 14. Forklift When present, this sticker indicates the location where to place the forks. FORKLIFT 15. Master This sticker is present only if the unit is equipped with option code CBM, and indicates the master (no sticker on the slaves). MASTER 5.307 ATTENZIONE! CIRCUITO FRIGORIFERO PRECARICATO CON AZOTO WARNING! PRECHARGED REFRIGERANT CIRCUIT WITH NITROGEN ACHTUNG! VERLADTER KÄLTEMITTELKREISLAUF MIT STICKSTOFF ATTENTION! CIRCUIT FRIGORIFIQUE PRE-CHARGE AVEC AZOTE BHИМАНИЕ! СИСТЕМА ЗАПРА�

  • Alfa Laval Alfa-V ACV Series, AHE00052EN 1904 9 Alfa Laval is a trademark registered and owned by Alfa Laval Corporate AB. Alfa Laval reserves the right to change specification without prior notification. A 4 Unpacking and lifting Always follow guidelines and instructions as given in the air cooled condensers & gas coolers prod- uct manual AHE00049. Before lifting the unit, check the weight stated on the name plate, located on the inlet connection side. Verify that the lifting equipment supports the unit weight plus 10%. When forklifts are used, forks must be longer than 2.5 m for safe lifting and be fully inserted under the unit. 4.1

  • Alfa Laval Alfa-V ACV Series, AHE00052EN 1904 10 Alfa Laval is a trademark registered and owned by Alfa Laval Corporate AB. Alfa Laval reserves the right to change specification without prior notification. With forklift B, insert the forks where indicated by sticker "Forklift" (under the centre of gravity) on the unit and slightly lift the unit. Remove hooks and chains and drive away with forklift A. A B B > 65° > 65° DETAIL A A 90° 90° Slowly drive forward with the truck until the unit is completely outside the container. 4.3 Lifting from above Verify that lifting lugs are safely fixed to the unit and have no signs of damage. Attach the

  • AHE00052EN 1904 11 Alfa Laval is a trademark registered and owned by Alfa Laval Corporate AB. Alfa Laval reserves the right to change specification without prior notification. 2 MOD 4 FANS 3 MOD 6 FANS 4 MOD 8 FANS 5 MOD 10 FANS 6 MOD 12 FANS 7 MOD 14 FANS 8 MOD 16 FANS 9 MOD 18 FANS

  • Alfa Laval Alfa-V ACV Series, AHE00052EN 1904 12 Alfa Laval is a trademark registered and owned by Alfa Laval Corporate AB. Alfa Laval reserves the right to change specification without prior notification. 5 Installation Always follow guidelines and instructions as given in the condenser & gas cooler product manual AHE00049. 5.1 Container skid removal (if present) Container skid option is selected in order to facilitate loading and unloading operations. 5 fan pair units container skids have two additional feet which can be recognized because above them there is no coil support, as shown in the picture. Container skid (included the additional feet,

  • Alfa Laval Alfa-V ACV Series, AHE00052EN 1904 13 Alfa Laval is a trademark registered and owned by Alfa Laval Corporate AB. Alfa Laval reserves the right to change specification without prior notification. 5.2 Mounting dimensions Drawings showing all required mounting and refrigerant connection dimensions are available for download on www.alfalaval.com. Dimensional drawings 5.3 Feet dimensions detail Feet dimensions are identical for all models. Avoid any lateral torque on the feet when fixing the unit to the ground. External fixing holes can be used only to fix the unit to the

  • Alfa Laval Alfa-V ACV Series, AHE00052EN 1904 14 Alfa Laval is a trademark registered and owned by Alfa Laval Corporate AB. Alfa Laval reserves the right to change specification without prior notification. 5.6 Vibration dampers For active and passive isolation of vibrations and reducing noise transmission, Alfa Laval strongly recommends the installation of vibration dampers. Installation of vibration dampers must be carried out before positioning the unit. Vibration dampers are to be positioned between the unit feet and the mounting base with the supplied M16 screw. Fan pairs Vibration dampers 2 4 3 4 4 6 5 8 6 8

  • AHE00052EN 1904 15 Alfa Laval is a trademark registered and owned by Alfa Laval Corporate AB. Alfa Laval reserves the right to change specification without prior notification. 5.7 Installation layout guideline Ensure installation is such that the following conditions are met: • Place the unit outdoor, so that it can be monitored and controlled from all sides at all times. • E

  • Alfa Laval Alfa-V ACV Series, AHE00052EN 1904 16 Alfa Laval is a trademark registered and owned by Alfa Laval Corporate AB. Alfa Laval reserves the right to change specification without prior notification. Platform for two to six units Number of fan pairs 2, 3 4, 5, 6 7, 8, 9 H ≥ (N-1)/2 (N-1)/1.2 N-1 d ≥ L/2 L/2 L/2 h ≤ (N-1)/2 (N-1)/1.2 N-1 N= number of units on the platform. All three conditions (H, d, h) shall be met. Contact Alfa Laval in case a different lay out is required. Special care should be taken in particular installations such

  • Alfa Laval Alfa-V ACV Series, AHE00052EN 1904 17 Alfa Laval is a trademark registered and owned by Alfa Laval Corporate AB. Alfa Laval reserves the right to change specification without prior notification. 6 Operation 6.1 Start-up procedure The following procedure is to be respected at every system start-up. • Verify there are no leaks in the refrigerant circuit and connections. • Switch on fan power supply. • Start the fans and verify fan direction. • After some operating time, verify that current absorbtion does no

  • Alfa Laval Alfa-V ACV Series, AHE00052EN 1904 18 Alfa Laval is a trademark registered and owned by Alfa Laval Corporate AB. Alfa Laval reserves the right to change specification without prior notification. 7.2 Stepping on the unit If for maintenance purposes it is required to step on the on the unit, always wear safety shoes. It is not allowed to step on the unit while it is working. Proper protection against falling shall be arranged with railings and safely fixed ladders. If the units do not have railings a safety device that p

  • Alfa Laval Alfa-V ACV Series, AHE00052EN 1904 19 Alfa Laval is a trademark registered and owned by Alfa Laval Corporate AB. Alfa Laval reserves the right to change specification without prior notification. 8 Spare parts Spare parts for Alfa-V ① Fan ② Switch on/off ③ Switchboard ④ Vibration damper ⑤ Protection grids (available on request) Spare parts can be selected and ordered in the online eBusiness tool Alfa Laval Anytime. If required please contact your local Alfa Laval representative for assistance. Alfa Laval Anytime ② ③ ④ ⑤ ①

Related Products and Documents (Air Conditioner):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Frigidaire FFU2124DW Factory parts catalog frigidaire/ffu2124dw-7G5.pdf 29 Jul 2022 7 0.18 Mb
2 Emerson CSI 9420 Reference manual emerson/csi-9420-XX5.pdf 12 Sep 2023 128
3 Simplex 4010-9811 Installation manual simplex/4010-9811-Z4B.pdf 06 Jul 2022 12
4 LG DP8821 Owner's manual lg/dp8821-5NH.pdf 22 Dec 2022 90
5 Sennheiser 100-P - 01-09 Instruction manual sennheiser/100-p-01-09-7OX.pdf 30 Sep 2023 37 5.22 Mb
6 Philips AVENT SCF123/42 Specifications philips/avent-scf123-42-M7P.pdf 01 Jun 2023 2 0.3 Mb

Similar Resources:

  • Samsung

    AS07A5MA

    (47 pages)
    SERVICEManualSPLIT TYPE AIR CONDITIONERAS07A5(6)MAAS09A5(6)MAFAS12AA(B)MCFIndoor UnitUS07A5(6)MAUS09A5(6)MAFUS12AA(B)MCFOutdoor UnitE DB98-15774A(1) AS07AS(6)MA SM_E 1/7/04 6:07 PM Page 47 …
  • Black & Decker

    BD06WT6

    (76 pages)
    ENGLISHINSTRUCTION MANUALELECTRONIC WINDOW AIR CONDITIONERThank you for choosing BLACK+DECKER! PLEASE READ BEFORE RETURNING THIS PRODUCT FOR ANY REASON.If you have a question or experience a problem with your BLACK+DECKER purchase, go to www.blackanddecker.com/instantanswers If you can’t find the answer or do not have access to the Internet, call 844-299- …
  • GE

    AE0CD10AM

    (56 pages)
    Cool Only ModelsAE1CD10AM / AE0CD10AM AE1CD14DM / AE0CD14DMAE1CD20DM / AE0CD20DMHeat/Cool ModelsAE1RD10AM / AE0RD10AM AE1RD14DM / AE0RD14DMAE1RD20DM / AE0RD20DMWrite the model and serial numbers herefor the indoor and outdoor units:Indoor Model # __________________Indoor Serial # ____________________Outdoor Model #____________________Outdoor Serial # ______ …
  • Mitsubishi Electric

    PUMY-P36NHMU

    (100 pages)
    TECHNICAL & SERVICE MANUALSPLIT-TYPE, HEAT PUMP AIR CONDITIONERSCONTENTS 1. TECHNICAL CHANGES................................... 2 2. SAFETY PRECAUTION.................................... 5 3. OVERVIEW OF UNITS...................................... 8 4. SPECIFICATIONS........................................... 10 5. DATA............................. …
  • Samsung

    Impression SGH-A877

    (230 pages)
    Serie SGH-a877TELÉFONO MÓVILPORTÁTIL DE BANDA CUÁDRUPLEManual del usuarioPor favor lea este manual antes de usar el teléfono y consérvelo para consultarlo en el futuro. …
  • Toshiba

    RAS-M10J2FVG-TR

    (16 pages)
    OWNER’S MANUAL ENGLISHTÜRKÇEAIR CONDITIONER (MULTIPLE TYPE)For general public useIndoor unitRAS-M10, 13, 18J2FVG-TR1112150136R32 or R410A1112150136-00_S01_182x257_16p_S_p70_190923.indd 1 1/24/2020 2:58:28 PM …

Comments, Questions and Opinions: