Manualios.com

ACPro AUHD18ND3F1O Installation Manual

ACPro AUHD18ND3F1O Manual Online:

3.8, 2050 votes
ACPro AUHD18ND3F1O User Manual
ACPro AUHD18ND3F1O User Guide
ACPro AUHD18ND3F1O Online Manual

Text of ACPro AUHD18ND3F1O User Guide:

  • ACPro AUHD18ND3F1O, Ʋƶ Sponge Threaded fastener(×4) Liquid pipe Gas inlet pipe Heat insulation sheath (for the gas tube) Heat insulation sheath (for the liquid tube) Table 3-2-2 Flare nut tightening torque Pipe Diameter Tightening Torque 6mm (1/4inch) 15~30N·m (11~22ft.-1b.) 9.5mm (3/8inch) 35~40N·m (26~29ft.-1b.) 12.7mm (1/2inch) 45~50N·m (33~37ft.-1b.) 16mm (5/8inch) 60~65N·m (44~48ft.-1b.) CAUTION! Be sure to connect the gas pipe after connecting the liquid pipe completely. ƴ.1.4 Connecting the Pipe at the Outdoor Side Unit Tighten the flare nut of the connection pipe at the outdoor unit valve connector.

  • ACPro AUHD18ND3F1O, ƷƱ NO. Name of Part AUHD30ND3F1O AC Pro # 63697 Part Code Quantity 1 Front Grill 01473050 1 2 Cabinet 01435004P 1 3 Left Handle 26235401 2 4 Front Side Plate 01305086P 1 5 Axial Flow Fan 10335014 1 6 Chassis Sub-assy 01195200013P 1 7 Drainage hole Cap 06813401 3 8 Electrical Heater(Compressor) 7651873209 1 9 Drainage Connecter 06123401 1 10 Compressor Overload Protector(External) 00180030/00183051/00183032/00183031 1 11 Compressor Gasket 76713066 3 12 Compressor and Fittings 0010505701 1 13 Cut off Valve 07133157 1 14 Silencer 07245012 1 15 Pressure Protect Switch 4602000902 1 16 Pressure Protect Switch 46020003 1 17 Valve Suppo

  • ACPro AUHD18ND3F1O, ƶƴ Disassembly of electrical parts box cover panel and electrical parts box Remark: Make sure that the power supply is cut off before disassembling and protect all the parts during disassembly, especially the electrical components. Do not dampen or hit them. Step Illustration Handling Instruction 1. Disassembly of electric box cover Disassemble the screw according to the position shown in the circle and the box and remove the electric box in the direction of the arrow. 2. Disassembly of electric parts box Disassemble the fastening screw and remove the electrical parts box. (As is shown in the graph, there are 2 fast

  • ACPro AUHD18ND3F1O, ƷƳ NO. Name of Part AUHD36ND3F1O AC Pro # 63696 Part Code Quantity 1 Front Grill 01574106 1 2 Cabinet 01435007P 1 3 Handle 26235253 2 4 Front Side Plate Sub-Assy 01305508 1 5 Axial Flow Fan 10335010 1 6 Chassis Sub-assy 01195244P 1 7 Electrical Heater(Compressor) 7651873209 1 8 Drainage Joint 26113009 1 9 Compressor Overload Protector(External) 00180030/00183051 / 00183032/00183031 1 10 Gas-liquid Separator Sub-Assy 07255201 1 11 Compressor Gasket 76713066 3 12 Compressor 00205200003 1 13 Electric Expand Valve Fitting 4300010839 1 14 Cut off Valve 071302391 1 15 Cut off Valve 07133157 1 16 Strainer 07213032 1 17 Strainer 07210045 1 18 Electronic Expansion Valve 07334194 1 19 Pressure Prot

  • ACPro AUHD18ND3F1O, ƳƲ CAUTION! The power cord and the wire of the fresh air valve are high-voltage, while the communication cord and connection wire of the wired controller are low-voltage. They should run separately against electromagnetic interference. The high-voltage and low-voltage lines should pass through the rubber rings at different electric box covers. Do not bundle the connection wire of the wired controller and the communication cord together, or arrange them in parallel, otherwise improper operation would occur. The high-voltage and low-voltage lines s

  • ACPro AUHD18ND3F1O, ƵƸ 18K ƹ.1 Outdoor Unit ƹ. Disassembly and Assembly Procedure of Main Parts Disassembly and Assembly of external casing Remark: Step Illustration Handling Instruction 1. Remove external casing 1. Remove the top cover and handle; 2. Remove the grille, outer case and right side plate. 2. Remove motor 1. Remove the blade nut and then remove the blade; 2. Remove the motor from motor support. 3. Remove compressor 1. Discharge the refrigerant inside the pipeline and recycle the refrigerant during discharging; 2. Unsolder the 4-way valve assy from compressor; 3. Remove the nut fixing compressor; 4. Take away the compressor from c

  • ƲƳ Ƴ.3 Caution for I tallation (3) Install the outdoor unit where the condensate water can be drained out freely during heating operation. (4) Do not place animals and plants in the path of the warm air. (5) Take the air conditioner weight into account and select a place where noise and vibration are small. (6) Install the outdoor unit where is capable of withstanding the weight of the

  • ACPro AUHD18ND3F1O, ƶ Table 3-1-2 Installation Accessories List for Duct-type Indoor Unit Name & Shape Qty Notes Installation and Operating Instructions 1 Insulation materials for gas pipe 1 Used for gas pipe connector on indoor unit Insulation materials for liquid pipe 1 Used for liquid pipe connector on indoor unit Insulation materials for drainage pipe 2 Used for wrapping the condensate pipe and rubber plug Nut M8 with gasket 8 Use for fixing the hanger hook 4 4 sets, used for ceiling mounting of the indoor unit Nut and spring gasket 4 Hook 4 Used for ceiling mounting of the indoor unit Strap 4 or 8 pcs 4 pcs for 18kBtu/h un

  • ACPro AUHD18ND3F1O, Ƶ • For the units: 36~48K Unit: mm (inches) Model A B C D E F G H I J AFH18D3F3I 1100 (43-3/8) 515 (20-3/8) 820 (32-1/4) 1160 (45-5/8) 1280 (50- 3/8) 560 (22) 1000 (39-1/2) 160 (6-1/4) 235 (9-1/4) 270 (10-1/2) AFH24D3F3I 1010 (39-3/4) 750 (29-1/2) 820 (32-1/4) 1115 (43-7/8) 1225 (48-1/4) 775 (30-1/2) 980 (38-5/8) 160 (6-1/4) 230 (9) 290 (11-3/8) AFH30D3F3I AFH36D3F3I 1175 (46-1/4) 645 (25-3/8) 850 (33-1/2) 1150 (45-1/4) 1340 (85-1/4) 750 (29-1/2) 980 (38-5/8) 19 (38-5/8) 230 (9) 350 (13-3/4) AFH42D3F3I AFH48D3F3I

  • Ʋƹ Table 3-2-4 ƴ.2 Specification of Connection Pipe MODEL Size of Fitting Pipe Inch Max. Pipe Length m (feet) Max. Height Dif- ference between Indoor Unit and Outdoor Unit m (feet) Drainage pipe (Outer Diameter × wall thickness) mm (inch) Liquid Gas AFH18D3F3I AUHD18ND3F1O 1/4 1/2 50(164) 15(49) 30×1.5 AFH24D3F3I AUHD24ND3F1O 3/8 5/8 50(164) 15(49) 20×1.2 AFH30D3F3I A

  • ACPro AUHD18ND3F1O, ƶƳ Removal and Assembly of Fan Motor Remarks: Before removing the fan, make sure to cut off the power firstly. Step Illustration Handling Instruction 6. Replace the motor Firstly, disengage the motor from motor support. Then, sequentially disengage the fan sub-assem- bly form the motor shaft. Remove the motor from the air inlet and replace with new motor. In which, for the motor with automatic motor support, the motor support shall be removed in advance and then changed to the unit. 7. Assemble the unit in reverse to the disassembly procedures Assemble the unit in reverse to the disassembly procedures and energize it for testing. Disassembly of filt

  • ACPro AUHD18ND3F1O, ƴ Condensate Drainpipes Level Instrument Air Intake Air Supply B A B Enlarged View Condensate Drainpipe As the inside of the unit is in the negative pressure status, it is required to set up a backwater elbow. The requirements is: $ %3LQFK P is the absolute pressure inside the unit. The unit of the pressure is psig. Figure 3-1-5 1.1.4 Dimension Data • For the units: 18~30K

  • ACPro AUHD18ND3F1O, ƸƵ 1Ʊ.1.3 Connecting the Pipe at the Indoor Unit Side Detach the caps and plugs from the pipes. When connecting the pipe to the unit or removing it from the unit, please do use both the spanner and the torque wrench (Figure 3-3-4). When connecting, smear both inside and outside of the flare nut with refrigeration oil, screw it hand tight and then tighten it with the spanner. Refer to Table 3-3-1 to check if the wrench has been tightened properly (too tight would mangle the nut and lead to leakage). Examine the connection pipe to see if it leaks, then take the

  • ACPro AUHD18ND3F1O, ƳƱ (4) Electric wiring between the indoor and outdoor units Single-Phase Units (36k~42k) (4) Electric wiring of indoor unit side Remove the electric box cover from the electric box sub-assy and then connect the wire.) The F, C, O connect to the COMMOM, CLOSE and OPEN terminal of the fresh air valve respectively. WARNING! Before starting work, check that power is not being supplied to the indoor unit and outdoor unit. Match the terminal block numbers and connection cord colors with those of the indoor unit side. Erroneous wiring may cause burning of the electric parts. . Erroneous wiring may cause bu

  • ACPro AUHD18ND3F1O, Ƴƴ Maintanence ƶ.Trouble Table ƶ.1 Main Control Malfunction Table 1 Fault Display on Indoor Wired Controller No. Error Code Malfunction Name Origin of malfunction signal Control Description 1E1 High pressure protection High pressure switch When outdoor unit detects the high pressure switch is cut off for 3s successively, high pressure protection will occur. All the loads (except the 4-way valve in heating mode) will be switched off. In this case, all the buttons and remote control signals except ON/OFF button w

  • Ƴƶ No. Error Code Malfunction Name Origin of malfunction signal Control Description 16 H4 Overload protection Evaporator temperature, condenser temperature If outdoor unit detects that the tube temperature is higher than protective temp. value, the unit will report overload pro- tection. The unit will not restart operation until tube tempera- ture is lower than the pr

Related Products and Documents (Air Conditioner):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Primus TiLite 324680 Instructions for use primus/tilite-324680-AIP.pdf 24 Feb 2024 4
2 Zebra ZQ110 Operation & user’s manual zebra/zq110-EX3.pdf 09 Aug 2022 38
3 Apple Color StyleWriter 4500 Service source apple/color-stylewriter-4500-ZYT.pdf 12 Dec 2022 165 4.35 Mb
4 Canvas 088-0733-8 Instruction manual canvas/088-0733-8-I9D.pdf 02 Sep 2022 13
5 Horizon Fitness T900 Operation & user’s manual horizon-fitness/t900-UGV.pdf 08 Feb 2024 19 5.26 Mb
6 Panasonic LX-1000U Operating instructions manual panasonic/lx-1000u-I19.pdf 26 Jun 2023 28 2.49 Mb

Similar Resources:

  • HAMPTON BAY

    Room Air Conditioners s

    (43 pages)
    Including Service and WarrantyIncluidos mantenimiento y la garantfaAvec service et garantieRoom Air Conditioners for Double-Hung WindowsAcondicionadores de aire ambiental para ventanas doblesClimatiseur d'air individuel pour fen_tres _ guillotine 16,000 - 25,000 BTU'S …
  • Fujitsu

    ARYG14LHTBP

    (144 pages)
    DESIGN & TECHNICAL MANUALAIR CONDITIONERDuct typeINDOORARYG12LHTBPARYG14LHTBPARYG18LHTBPARYG24LHTBPARYG30LHTBPARYG36LHTBPARYG45LHTBPARYG54LHTBPOUTDOORAOYG12LBLAAOYG14LBLAAOYG18LBCAAOYG24LBCAAOYG30LBTAAOYG36LBTAAOYG45LBTAAOYG54LBTADR_AR006EF_042016.04.22 …
  • Mitsubishi Electric

    DXK09ZJ-S

    (115 pages)
    RESIDENTIAL AIR-CONDITIONINGTECHNICAL MANUAL & PARTS LISTINVERTER WALL MOUNTED TYPERESIDENTIAL AIR-CONDITIONER(Split system, air to air heat pump type)DXK09ZJ-SDXK12ZJ-SDXK18ZJ-SManual No.'11•SRK-T-118 …
  • Fujitsu

    9379123037-02

    (15 pages)
    INSTALLATION MANUALFor authorized service personnel only.INSTALLATIONSANLEITUNGNur für autorisiertes Personal.MANUEL D'INSTALLATIONPour le personnel agréé uniquement.MANUAL DE INSTALACIÓNSolo para personal autorizado.MANUALE D'INSTALLAZIONEAd uso esclusivo del personale autorizzato.ǼīȋǼǿȇǿǻǿȅǼīȀǹȉǹȈȉǹȈǾȈīȚĮİȟȠ� …
  • General

    ABG14FBBJ

    (37 pages)
    CONTENTSSPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1OUTLINE AND DIMENSIONS . . . . . . . . . . . . . . . . . . . .3REFRIGERANT SYSTEM DIAGRAM . . . . . . . . . . . . .5ERROR DISPLAY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12CIRCUIT DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8P …
  • Samsung

    SGHI627

    (152 pages)
    SGH-i627TELÉFONO MÓVILPORTÁTIL DE BANDA CUÁDRUPLEManual del usuarioPor favor lea este manual antes de usar el teléfono y consérvelo para consultarlo en el futuro. …

Comments, Questions and Opinions: