Goodwe EH Series Operation & User’s Manual
|
TABLE OF CONTENTS 021.2 SAFETY & WARNINGS 041.3 PRODUCT OVERVIEW 011.1 OPERATION MODES INTRODUCTION INTRODUCTION 01 052.1 UNACCEPTABLE INSTALLATIONS 052.2 PACKING LIST 062.3 MOUNTING 062.3.1 SELECT MOUNTING LOCATION 072.3.2 MOUNTING 082.4 ELECTRICAL WIRING CONNECTION 082.4.1 PV WIRING CONNECTION 102.4.3 ON-GRID & BACK-UP CONNECTION 132.4.4 SMART METER &
Goodwe EH Series, 1.2 SAFETY & WARNING • SYMBOLS EXPLANATION INTRODUCTION01 Caution! Failing to observe a warning indicated in this manual may result in injury. Danger of high voltage and electric shock! Components of the product can be recycled. This side up! The package must always be transported, handled and stored in such a way that the arrows always point upwards. Danger of hot surface! No more than six (6) identical packages being stacked on each other. Product should not be disposed as household waste. The package/product should be handled carefully and never be tipped over or slung. Refer to the operating instructions. Keep dry! The package/product must be protected from excessive humidit
Goodwe EH Series, INTRODUCTION • SAFETY WARNING 03 INTRODUCTION 1.3 PRODUCT OVERVIEW 04 Wi-Fi Box Label DRED Meter Wi-Fi Reset Smart Smart Reserved RS485 Prohibit to insert or pull the AC and DC terminals when the inverter is running. Before any wiring connection or electrical operation on inverter, all battery and AC power must be disconnected from inverter for at least 5 minutes to make sure inverter is totally isolated to avoid electric shock. The temperature of inverter surface might exceed 60℃ during working, so please make sure it is cooled down before touching it, and make sure the inve
Goodwe EH Series, 2.1 UNACCEPTABLE INSTALLATIONS 2.2 PACKING LIST INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS 05 06 Smart Meter 2.3.1 SELECT MOUNTING LOCATION 2.3 MOUNTING Direct Sunlight Exposure to Rain Exposure to SnowNo Direct Sunlight No Exposure to Rain No Exposure to Snow Pic 2 Upward---------- Downward------ Front------------- Both sides------- 300mm 500mm 300mm 200mm 300mm 300mm 200mm 200mm 500mm Pic 3 Pic 1 INSTALLATION INSTRUCTIONS02 PE terminal × 1 Expansion bolts×4 User manual×1 Quick Installation Guide×1 Smart Meter & CT × 1 Inverter×1 Wall-mounted Bracket×1 BE CONNE
Goodwe EH Series, The inverter is suitable for mounting on concrete or other non-combustible surface only INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS 07 08 2.3.2 MOUNTING • Please use the mounting bracket as a template to drill 4 holes on right positions (10mm in diameter, and 80mm in depth) (Pic 4) • Use expansion bolts in accessory box and fix the mounting bracket onto the wall tightly Step 1 Pic 4 2.4 ELECTRICAL WIRING CONNECTION 2.4.1 PV WIRING CONNECTION self-tapping screws Wall bracket Expansion pipe 19.33 Use the right PV plugs in the accessory box (BAT plugs are similar with PV plugs, please confirm before use it.) . . . . Note: Bearing capacity of the wall must be
09 10 INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Push the insert into the sleeve (C). Tighten the cable gland to 2 Nm (D). Use a suitable and calibrated torque wrench, size 15. Use an open-jaw wrench, size 16, to hold the connector in place. Fit the two connectors together until the connection audibly locks into place. Check to make sure the connection is securely locked. 14 15 Use the r
NOTE: 1. The Smart Meter and CT is well configured, please do not change any setting on Smart Meter 2. CT must be connected on the same phase with Smart Meter power cable 2.4.3 SMART METER & CT CONNECTION • Single-Phase Smart Meter Wiring (Pic 13) • Detailed pin function of each port on BP converter is as below: Make sure AC cable is totally isolate
Goodwe EH Series, Smart Meter 2. One Smart Meter can only be used for one EH inverter. 3. CT must be connected on the same direction as the CT indicated. Smart Meter Smart Meter 14 27 2.5 DRED & REMOTE SHUTDOWN CONNECTION DRED is used for Australia and New Zealand installation (also used as remote shutdown function in European countries), in compliance with Australia and New Zealand safety requirements( or European countries). And DRED device is not provided by GoodWe. 13 INSTALLATION INSTRUCTIONS MAMUAL OPERATION The Smart Meter with CT in GoodWe product box is compulsory for EH s
Goodwe EH Series, 40A *1 *2 Please select Breaker according to the specification below ① ② ④ ⑤ ③ GW3600-EH GW5000-EH GW6000-EH ① ② ③ ④ ⑤ 40A/600V DC breaker 1.For batteries with attached breaker, the external DC breaker is not necessary. 2.Direction of the CT cannot be connected in reverse, please follow House (K)→Grid (L) direction to do the connection. Depends on household loads 32A/230V AC breaker 32A/230V AC breaker 40A/230V AC breaker 50A/230V AC breaker 63A/230V AC breaker 63A/230V AC breaker
Goodwe EH Series, 17 18 • This part shows configuration on web page • Wi-Fi configuration is absolutely necessary for online monitoring and after-sales maintenance 3.1 WIFI CONFIGURATION MAMUAL OPERATION03 PREPARATION: 1. Inverter must be powered up with only PV power 2. Need a router with available internet access to GoodWe portal https://www.semsportal.com 1. Connect Solar-WiFi* to your PC or smart phone(* means the last 8 characters of the inverter serial No.) 2. Open browser and login 10.10.100.253 Admin (U): admin; Password: admin 3. Then click “OK” 1. Click “Start Setup” to choose
Goodwe EH Series, 14 MAMUAL OPERATION OTHERS 19 20 OTHERS04 PV Master is an external monitoring/ configuration application for GoodWe hybrid inverters, used on smart phones or pad for both Android and iOS system, main functions as below: 1. Edit system configuration to make the system work as customer needs. 2. Monitor and check performance of the hybrid system. 3. Wi-Fi configuration. Please download PV Master OPERATION INSTRUCTIONS from www.goodwe.com Note: GoodWe will keep right to explain all the contents in this user manual. To insure IP65, inverter must be sealed well, pl
Goodwe EH Series, OTHERS OTHERS 17 21 22 open PV or BAT voltage is too high 1. Use multi meter to check if the resistance between earth & inverter frame is about zero. If it's not, Please make the connection between earth & inverter frame well. 2. If the humidity is very high, there maybe Isolation Failure occur. 3. Check the resistance betwen PV1+/PV2+/BAT+/PV- to earth, if the resistance is lower than 33.3k, check the system wiring connection. 4. Try to restart the inverter, check if the fault is st
23 24 Smart (L/N are in sequence) Smart Meter OTHERS OTHERS Possible Problems During Operation EH and Smart meter is OK or not; (20%+1-DOD)/ 2 100W 100W Inverter 100W EH EH EH EH 33 34 35 36 2 B 5 33 34 35 36 36 Note: For compatible lithium batteries, BMS status is "Communication OK" after selecting the right battery stype.
Goodwe EH Series, OTHERS OTHERS 4.4 TECHNICAL PARAMETERS AND CERTIFICATES • TECHNICAL PARAMETERS OF HYBRID CONVERTERS 25 26 EH EH EH EH EH EH S Off-Grid Output Switch Off-Grid Output Switch H A:For EH series inverter, it could connect Lithium batteries which have compatibility with EH series inverter. With nominal voltage from 85V to 450V. Compatible lithium batteries can see on battery list in PV MASTER APP
Goodwe EH Series, OTHERS OTHERS 27 28 TECHNICAL PARAMETERS OF EH INVERTER Technical Data Battery Type Battery Input Data Battery Voltage Range(V) Start-up Voltage (V) Max. Charging/Discharging Current (A) Max. Charging/Discharging Power (W) PV String Input Data Max. DC Input Voltage (V) Max. DC Input Power (W) MPPT Range (V) Start-up Voltage (V) MPPT Range for Full Load (V) Nominal DC Input Voltage (V) Max. Short Current (A) Max. Input Current (A) PV Overcurrent Protection (A) PV Back-feed Current (A) No. of MPP Trackers No. of Strings per MPP Tracker Nominal Apparent Power Output to Utility Grid (VA) Max. Apparent Power Output
Goodwe EH Series, OTHERS OTHERS 29 30 *Can be reached only if PV and battery power is enough **No Back-up Output [1] 4600 for VDE-AR-N 4105, 5000 for Australia, 6000 for other country. [2] 4600 for VDE-AR-N 4105, 5000 for other country. [3] 4600 for VDE-AR-N 4105, 5000 for Australia, 6600 for Italy, 6000 for other country. [4] 4600 for VDE-AR-N 4105, 5500 for Italy, 5000 for other country. [5] 3960 for Italy, 3600VA for other countries. [6] 21.7 for Australia. [7] [8][9] for Italy. t u v - s u d .c o m / p s - c e r t T y pe t es te d P ro d uc ti o n
Goodwe EH Series, 31 4.5 CHECKING THE ELECTRICAL CONNECTION 1. Check if the AC or DC wire is loose. 2. Check if the earth wire is reliable grounding. 3. Check if the waterproof covers of BMS and Meter port is fasten. Caution: Maintenance cycle is once half a year. 4. Please use torque wrench to tighten the AC and battery terminal wiring connection once a year; followed 2.4 torque instruction. OTHERS
Goodwe GW1500-NS Inverter Operation & user’s manual
GW1500-NS |
Goodwe SDT SERIES Inverter Operation & user’s manual
SDT SERIES |
Goodwe ET Series Inverter Manual
ET Series |
Goodwe Smart DT Series Inverter Operation & user’s manual
Smart DT Series |
Goodwe GW1000-NS Inverter Operation & user’s manual
GW1000-NS |
Goodwe SDT G2 Series Inverter Operation & user’s manual
SDT G2 Series |
Goodwe GW60K-MT Inverter Introduction manual
GW60K-MT |
Goodwe DT Series Inverter Operation & user’s manual
DT Series |
# | Manufacturer | Model | Document Type | File | Updated | Pages | Size |
---|---|---|---|---|---|---|---|
1 | Roberts | RD70 | Manual | roberts/rd70-718.pdf | 22 Nov 2022 | 28 | |
2 | Klimaire | 19 SEER | Operation & user’s manual | klimaire/19-seer-N39.pdf | 30 Jun 2022 | 16 | |
3 | Chrysler | Sebring | Quick reference manual | chrysler/sebring-66X.pdf | 09 Aug 2022 | 12 | 1.19 Mb |
4 | Lenovo | ThinkCentre M57 | Operation & user’s manual | lenovo/thinkcentre-m57-298.pdf | 16 Nov 2022 | 80 | |
5 | HP | 3845 - Deskjet Color Inkjet Printer | Operation & user’s manual | hp/3845-deskjet-color-inkjet-printer-6OR.pdf | 08 Jan 2024 | 91 | 1.45 Mb |
6 | Microsoft | SideWinder X6 | Quick start | microsoft/sidewinder-x6-LR9.pdf | 13 Jun 2023 | 3 |
Global Solutions
Produc Dev Ope1. 2. W3. Tswitc PIsct Solutions Avices anInverter: VC2000 OpPM motor:PLC: DVPConnectoreration Setting neannouncemWiring 28SSetting DVThe DeviceNch but also nProduct ssued by nnouncementC20nd toolsVFD007C23ptional Card: ECMA-C328SV11T+r: TAP-CN0Steps: cessary Paments relaSV and C2VPDNET MNet Master aneed to set DAMDGlobalt 000 De: 3A, Firmwad: …
Delta VFD-C2000(5 pages) |
Mid-Continent Instrument
Installation Manual and Operating Instructions Model TI1200 Series Static Electrical Power Inverter True Blue Power® is a division of Mid-Continent Instrument Co., Inc. Mid-Continent Instrument Co., Inc. dba Mid-Continent Instruments and Avionics 9400 E. 34th Street N. Manual Number 9017680 Wichita, KS 67226 Rev G, July 17, 2019
…
TRUE BLUE POWER TI1200 Series(17 pages) |
YASKAWA
PVI 50TL PVI 60TL INSTALLATION AND OPERATION MANUAL Revision E ©2017, Yaskawa - Solectria Solar
…
PVI 60TL(104 pages) |
OutBack Power
Components900-0155-01-00 Rev B.vsd\Page-1\2013-06-10©2013 OutBack Power Technologies. All Rights Reserved.Contact Technical Support:Telephone: +1.360.618.4363Email: [email protected]: www.outbackpower.comIMPORTANT: Not intended for use with life support equipment.Optional OutBack ComponentsSystem Display MATE3 Radian System Products Ma …
GSLC175-AC-120(4 pages) |
Peak
Inversor de Energía de 100 VatiosNo. de Modelo: PKC0AMManual del Propietario e Información de GarantíaLea completamente estas instrucciones antes de usar este producto.Conserve este Manual del Propietario para referencia futura.19/13© 2013100 Watt Power InverterModel No.: PKC0AMOwner’s Manual and Warranty InformationRead these instructions completely b …
PKC0AM(8 pages) |
Groen
THIS MANUAL MUST BE RETAINED FOR FUTURE REFERENCE FOR YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE POST IN A PROMINENT LOCATION INSTRUCTIONS TO BE FOLLOWED IN THE EVENT USER SMELLS GAS. THIS INFORMATION SHALL BE OBTAINED BY CONSULTING YOUR LOCAL GAS SUPPLIER. AS A MINIMUM, TURN …
NGB Series(25 pages) |
Haier TV 21FA11Haier 21FA11 TV Owner's manual 21FA11, 26 |
Uwatec Watch Digital 330mWatch #DQU2X5 Digital 330m, 17 |
ATTO Technology Host Adapter ATTO ExpressPCI FC 3305PDF Guide (@1E3Z2D), ATTO Technology ATTO ExpressPCI FC 3305 Host Adapter (Sunday 12-11-2023) ATTO ExpressPCI FC 3305, 2 |
Tunturi Elliptical Trainer C85Tunturi C85 Manual (Doc Type: Elliptical Trainer Owner's manual) C85, 91 |
Prima Kitchen Appliance PDD200Prima Kitchen Appliance PDD200 Instruction booklet PDD200, 6 |
Parkside Drill PBSA 12 A1Drill PDF Instruction manual PBSA 12 A1, 100 |
JVC Camcorder GR-DVM96GR-DVM96 Instructions manual - JQ2271 GR-DVM96, 104 |
Signature Controller EZ Pro Jr. IndoorSignature EZ Pro Jr. Indoor Manual (Installation and programming manual), @739FSW EZ Pro Jr. Indoor, 24 |
Kenwood Microwave Oven KEN CJ99SSAKEN CJ99SSA (Microwave Oven ePDF Guide, #F3XUW4) KEN CJ99SSA, 40 |
Panasonic Other SCHDA710PDF User Guide (@65C126), Panasonic SCHDA710 Other (Thu 01.2024) SCHDA710, 104 |
HANNspree LCD TV K223-10A1HANNspree K223-10A1 User Guide (Doc Type: LCD TV Operation & user’s manual) K223-10A1, 61 |
Omnitronic Recording Equipment DXO-26Recording Equipment Operation & user’s manual (Omnitronic DXO-26) DXO-26, 24 |