  • Asus ASMB3-SOL, ASUS ASMB3-SOL 3-23 To view the System Data Record (SDR): 1. Select BMC SDR from the View command option, then press <Enter>. A complete list of data records appears on the left pane. The right pane displays the sensor data information. The number on the bottom left of the screen indicates the data record displayed in the right window pane over the total number of sensor data records in the remote host. 2. Use the down arrow key to display the next sensor data record. 3. Press <Esc> to return to the main screen. To view the System Event Log (SEL): 1. Select BMC SEL from the View command op

  • Asus ASMB3-SOL, A-4 Appendix: Reference information A.3 Troubleshooting Problem Solution The local/central server cannot connect to the ASMB3-SOL board. 1. Check if the LAN cable is connected to the LAN port for server management. See page A-2 for details. 2. Check if the remote server LAN port is working properly. If you have not previously installed the LAN controller driver, install the same using the system support CD. 3. Make sure that the AC power cord has been unplugged for at least 5 seconds

  • Asus ASMB3-SOL, ASUS ASMB3-SOL 2-3 4. Press the board rmly until the BMC socket retaining clips snap back and secure the board in place. When installed, the board appears as shown. 5. Reinstall the server system cover, then connect the power plug to a grounded wall socket. 6. Insert the LAN cable plug to the LAN port for server management. Refer to the Appendix for the location of the LAN port for server management on various server motherboards. 7. For direct LAN conguration, connect the other end of the LAN cable to the local/central server LAN port. For connection to a network hub or router, connect t

  • Asus ASMB3-SOL, vi Safety information Electrical safety • To prevent electrical shock hazard, disconnect the power cable from the electrical outlet before relocating the server. • When adding or removing devices to or from the server, ensure that the power cables for the devices are unplugged before the signal cables are connected. If possible, disconnect all power cables from the existing server before you add a device. • Before connecting or removing signal cables from the server, ensure that all power cables are unplugged. • Seek professional assistance before using an adapter or extension cord. These devices could interrupt the grounding circuit. • Make sure that your power sup

  • Asus ASMB3-SOL, ASUS ASMB3-SOL 3-3 3.1.1 ARC sections Menu bar The Menu bar contains all the commands for the ARC application. Click on a menu to display a list of available commands. Tool bar The Tool bar buttons correspond to commonly used commands. The Tool bar offers faster access and execution of these commands. Roll the mouse pointer over a button to display its function. Navigation window The Navigation window displays the directory of connected and disconnected remote server(s). For multiple monitoring, this window allows you to navigate through the remote servers. Click the All Servers root directory to display all connected and disconnected serv

  • Asus ASMB3-SOL, ASUS ASMB3-SOL 3-7 The navigation window displays the remote server. The available remote server information are displayed on the Detail/SEL window. 4. Use any of these options to connect to the server: • Click before the remote server to display the remote server information, then select from the list. • Double-click a remote server information from the Detail/SEL window. • Click Server, then select Connect. 5. When prompted, enter the default user name (admin) and password (admin). 6. Set the co

  • Asus ASMB3-SOL, ASUS ASMB3-SOL 2-13 ASMC Help Menu options 2.5.1 Conguring the LAN controller Before you can establish connection to the ASMB3-SOL board, you must congure the LAN port for server management used by the remote server to connect to the local/central server. To congure the LAN port of the remote server: 1. On the prompt, type asmc -init_asmb, then press <Enter>. The screen displays the auto-detected information including the system/motherboard name, and the IPMI2.0 interface. The screen also shows the status of the ASMB3-SOL. 2. Shut down the remote server, then disconnect the power plug from the elec

  • Asus ASMB3-SOL, 2-12 Chapter 2: Installation Refer to the table on the next page for a description of the help menu options. 2.5 Running the ASMC utility The ASUS Server Management Card Utility allows you to know the MAC address of the server motherboard and to set the IP address. This utility is available from the support CD that came with the package. To run the ASMC utility: 1. Restart the remote server, then place the support CD to the optical drive. 2. Press <a> (FreeDOS command prompt) when the screen p

  • Asus ASMB3-SOL, 2-4 Chapter 2: Installation To uninstall the board: 1. Simultaneously push the BMC socket retaining clips outward until the board tilts up. 2. Carefully pull the board out from the BMC socket, then set aside.

  • ASUS ASMB3-SOL 2-9 You must congure the network settings of both the remote server and the local/ central server to establish communication for remote server control and monitoring. Prepare the support CD and a bootable oppy disk to congure the network settings. Running the BIOS IPMI conguration To congure the IPMI in the BIOS: 1. Restart the remote server, then press &l

  • Asus ASMB3-SOL, 3-16 Chapter 3: Software support 3.1.9 Updating the remote server BIOS le The ASMB3-SOL features a remote BIOS le update capability that allows you to update the BIOS le of the remote server when the le gets outdated or corrupted. To update the remote server BIOS le: 1. Download and save the latest BIOS le for the remote server motherboard. 2. From the navigation window, click Remote Console to display the remote server screen. See section 3.1.6 for details. 3. Click the update BIOS icon [ ] in the toolbar. 4. Locate the latest BIOS le when the Open window appears, the click Open. 5. Click Yes when the Conrm

  • Asus ASMB3-SOL, 3-20 Chapter 3: Software support Important notice for Windows ® XP (Service Pack 2) users If the remote server system is behind a rewall, you must create a UDP port to receive PET information. To create a UDP port: 1. Double-click the My Computer icon from the Windows ® desktop, then click the My Network Places link. 2. Click the View network connections link, then select the LAN connection the remote server system is using. 3. Right-click the LAN connection, then select Properties from the drop-down menu. 4. Click the Advanced tab, then click the Settings button. 5. On the Services tab, click the Add button to display a Serv

  • 3-10 Chapter 3: Software support 3.1.4 Displaying FRU information The Field Replaceable Unit (FRU) information provides the manufacturer, product name, and/or serial number of various modules and components installed on the remote server. For example, the FRU feature can display the remote server motherboard name, model, and serial number. You can use this

  • Asus ASMB3-SOL, ASUS ASMB3-SOL 2-7 Update Firmware Version : 1.01 (DSBF-D/SAS, DSBF-D, DSBV-D, DSCC-D12/SAS, DSCC- D12, DSCC-DW Update Firmware Version : 1.01 (KFN4-DRE) Do you want to update rmware (y/n)? Now, Starting to update rmware Detect Flash Type - 2168 Programming Flash ... Progress : 100 Initial BMC. Please wait.. Wait BMC ready. Initial BMC O.K. Update rmware Finish! Detect MotherBoard -> (KFN4-DRE) Detect KCS Interface Size of SDR is 1728 bytes enter update mode Clear SDR ? (Y/N) Clear SDR. Loading SDR SDR Loaded ! Exit update mode Please turn off the stand by power !! Press any key to continue . . .

  • Asus ASMB3-SOL, 2-8 Chapter 2: Installation 2.4 BIOS conguration You need to adjust the settings in the BIOS setup of the remote server for correct conguration and connection to the cental server. Update the remote server BIOS le following the instructions in the motherboard/system user guide. Visit the ASUS website (www.asus.com) to download the latest BIOS le for the motherboard. Select Screen Select Item +- Change Option F1 General Help F10 Save and Exit ESC Exit v02.58 (C)Copyright 1985-2004, American Megatrends, Inc. BIOS

  • Asus ASMB3-SOL, iii Notices .......................................................................................................... v Safety information ...................................................................................... vi About this guide ........................................................................................ vii ASMB3-SOL specications summary ....................................................... ix Chapter 1: Product introduction 1.1 Welcome! ...................................................................................... 1-2 1.2 Package contents ....................................................

  • Asus ASMB3-SOL, 3-2 Chapter 3: Software support 3.1 ASUS Remote Console (ARC) The ASUS Remote Console (ARC) is a web-based utility that allows you to monitor the remote host’s hardware information including temperatures, fan rotations, voltages, and power. This application also lets you instantly power on/off or reset the remote server. 1 2 4 3 5 6 The ARC window is made up of six sections: 1. Menu bar 2. Tool bar 3. Navigation window 4. Detail/SEL window 5. Event window, and 6. Status bar Refer to the following sections for details.

  • Asus ASMB3-SOL, 2-14 Chapter 2: Installation When nished, the utility returns to the DOS prompt. 6. Type asmc -bmc_info on the prompt, then press <Enter> to display the BMC and PET IP and MAC addresses. 5. Type asmc -bmc_ip xxx.xxx.xxx.xxx, then press <Enter> to assign any IP address to the remote server LAN port. The screen displays the request and response buffer. Write the remote server IP address in a piece of paper for reference. 7. Restart the remote server, enter the BIOS setup, then boot from the hard disk drive. 8. Congure the ASMB3-SOL baud rate (asmc -sol_baud 57600). c:\dos>asmc -bmc_ip 10.10.10.20 Detect

  • 3-26 Chapter 3: Software support 3.2.7 Help The Help command displays the available utility options, utility version, and copyright information. 3.2.6 Monitor The Monitor command displays real-time data on the remote server system and CPU temperatures, voltages, and fan speeds. To display a remote server information: 1. Select a sensor from the Monitor command options, then press &l

  • vii About this guide This user guide contains the information you need when installing and conguring the server management board. How this guide is organized This guide contains the following parts: • Chapter 1: Product introduction This chapter describes the server management board features and the new technologies it supports. • Chapter 2: Installation This chapter

  • Asus ASMB3-SOL, 2-2 Chapter 2: Installation 2.2 Hardware installation To install the server management board: 1. Remove the remote server system cover, then locate the Baseboard Management Controller (BMC) socket on the motherboard. 2.1 Before you proceed Take note of the following precautions before you install the server management board to the remote server system. • Unplug the server system power cord from the wall socket before touching any component. • Use a grounded wrist strap or touch a safely grounded object or to a metal object, such as the power

  • Asus ASMB3-SOL, ASUS ASMB3-SOL 3-25 3.2.5 Set The Set command controls the host interface type and the correct BMC time. You can select from the following interfaces: KCS Interface - Keyboard Controller Style SMIC Interface - Server Management Interface Chip BF Interface - Block Transfer PCI Interface - Peripheral Component Interconnect 3. When nished, press <Esc> to return to the main screen. To set the BMC Timer: 1. Select BMC Timer from the Set command option, then press <Enter>. 2. Set the BMC IPMI timer to the current system time. 3. When nished, press <Esc> to return to the main

  • Asus ASMB3-SOL, ASUS ASMB3-SOL 2-15 2.5.2 Using ASWM to update the ASMB3-SOL rmware You can use the ASUS System Web-based Management (ASWM) application to update the ASMB3-SOL rmware. To do this: 1. Download the latest ASMB3-SOL rmware from the ASUS website (www. asus.com), then save the rmware le. 2. Launch the ASWM application. If ASWM is not yet installed on your server system, use the motherboard support CD to install the application. 3. Click the Conguration link, then select IPMI Flash from the menu. 4. Click Browse to locate the latest rmware you downloaded earlier. When selected, the rmware path and lename a

  • Asus ASMB3-SOL, 3-6 Chapter 3: Software support 3.1.2 Connecting to the remote server To connect to the remote server: 1. From the menu bar, click Server, then select New. An Add new server connection window appears. 2. Type the remote server name and IP address on the elds. Click Save Default to set the remote server connection as the default. Otherwise, click OK to continue or Cancel to close the window. The default server connection name and IP address are automatically displayed everytime you add a ne

  • Asus ASMB3-SOL, ASUS ASMB3-SOL 2-5 2.3 Firmware update You need to update the Broadcom ® IPMI and ASMB3-SOL rmware before you start using the ASMB3-SOL board. 2.3.1 For motherboards with Broadcom ® 5721 LAN To update the rmware: 1. Insert the support CD into the optical drive. 2. Restart the remote server, then press <Del> during POST to enter the BIOS setup. 3. Go to Boot menu and set the Boot Device Priority item to [CD-ROM]. 4. When nished, press <F10> to save your changes and exit the BIOS setup. 5. On reboot, the main menu appears. Type <c> (Broadcom IPMI Firmware Update). 6.

More Instructions:

DOWNLOAD

Related Products and Documents (Server Board):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Hanna Instruments HI 93713 Instruction manual hanna-instruments/hi-93713-E21.pdf 16 Sep 2022 2 0.38 Mb
2 Sprint Mobile Digital TV Manual  sprint/mobile-digital-tv-3J4.pdf 10 Nov 2023 22 1.87 Mb
3 HP Deskjet F2410 Reference manual hp/deskjet-f2410-68X.pdf 06 Oct 2022 16 1.04 Mb
4 HP EliteBook 8440P Quickspecs hp/elitebook-8440p-V4N.pdf 24 Oct 2023 41
5 Enter-Tech MagicSing ED-8000 Specifications enter-tech/magicsing-ed-8000-193.pdf 07 Aug 2023 1 0.54 Mb
6 Okina SS10C-C50H Operation & user’s manual okina/ss10c-c50h-H6Q.pdf 11 Nov 2022 32

Similar Resources:

  • Supero

    SUPERSERVER 8047R-TRF+

    (146 pages)
    SUPERSERVER8047R-TRF+8047R-7RFT+® SUPERUSER'S MANUALRevision 1.0bПроконсультироваться и купить данное оборудование вы можете в компании «АНД-Системс» адрес: 125480, г.Москва, ул.Туристская, д.33/1; site: https://andpro.ru тел: +7 (495) 545-4870 emai …
  • Intel

    X38ML - Server Board Motherboard

    (132 pages)
    Intel® Server Board X38ML Technical Product Specification Intel order number E15331-006 Revision 1.3June 2010Enterprise Platforms and Services Division – Marketing …
  • Intel

    SDS2

    (145 pages)
    Intel® Server Board SDS2 Technical Product Specification Order Number: A85874-002 Revision 1.2 December 2, 2002 Enterprise Platforms and Services Marketing …
  • Supermicro

    SuperServer 510P-WT/WTR

    (113 pages)
    USER’S MANUAL Revision 1.0®510P-WT/WTRПроконсультироваться и купить данное оборудование вы можете в компании «АНД-Системс» адрес: 125480, г.Москва, ул.Туристская, д.33/1; site: https://andpro.ru тел: +7 (495) 545-4870 em …
  • ASROCK Rack

    EP2C6212D16NM

    (2 pages)
    EP2C6212D16NM Quick Installation Guidewww.asrockrack.comNo. Description1 USB 3.0 Ports (USB3_1_2)2 LAN RJ-45 Port (IPMI_LAN1)3 VGA Port (VGA1)4 UID Switch (UID)42P/N: 15G065099000AK V1.0Install the Server BoardMotherboard LayoutJumper Cap On/OThe server board User's Manual is available for download from the ASRock Rack's ofcial website at h …
  • Intel

    S5500WB

    (9 pages)
    Intel® Server Board S5500WB Intel® Server System SR1690WB Spares/Parts List and Configuration Guide A reference guide to assist customers in ordering the necessary components to configure the Intel® Server Board S5500WB and the Intel® Server System SR1690WB. Revision 1.7Enterprise Platforms and Services Marketing …

Comments, Questions and Opinions: