Text of Philips SEM 525 User Guide:

  • Philips SEM 525, PHILIPS SEM 525 INSTRUCTIONS Start-up: Turn master mains switch on (if not already on) Turn the water cooler/circulator timer on to HOLD (counter clockwise) Press the SEM mains button ON (lower left panel, listen for the mechanical vacuum pump to come on) Press the vacuum ON button The red high vacuum light (left most panel) will be lit. After about 30 minutes, this light indicator will turn off indicating a sufficient vacuum to operate the microscope. However, to ensure maximum filament life, do not turn the beam on

  • Use gun bias 1 for 20 and greater kv and bias 2 for 10 – 20 kv. Use a spot size of 500 and the lowest magnification to align the electron gun. Non-conductive samples may charge with these settings. Biological specimens that have been coated usually can be viewed with a lower accelerating voltage, usually 10 – 15 kV. With

  • Philips SEM 525, Do not handle specimen stubs with your bare fingers. Contaminates from your fingers will volatilize in the high vacuum and contaminate the final beam aperture and detectors which in turn will significantly degrade the image. The “X” and “Y” controls are approximately centered at 500 X 500 with TILT at 0 degrees. Do not adjust the TILT less than 0 degrees nor greater than 90 degrees. Turning ON the electron beam: Turn ON the high tension. There should be a “blip” in the filament current gauge. Adjust the current to saturation (usually 5-6 clicks). Do not over- saturate the filament. A

  • Philips SEM 525, Press and “release” the AIR button and press the vacuum ON button. You should hear the vacuum pull the door sealed shut. When the vacuum is ready (10 or less on the vacuum gauge and RED high vacuum light is off), the electron beam may be turned on. Shutting down the SEM: Turn the filament current to zero. Turn off the high tension by pushing the HT button and letting it release. Turn the black detector gain down 1 turn (clockwise). Turn off the SE detector (push the button and let it release). Turn the spot size to 500 (this is the lowest lens current setting). Turn the magnific

Related Products and Documents (Microscope):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 LG Deluxe central controller Installation manual lg/deluxe-central-controller-4G6.pdf 30 May 2023 28
2 MAGNEPLANAR MG1.6 Instruction manual magneplanar/mg1-6-RHX.pdf 30 Sep 2023 9
3 OK. OFC 1111 Instruction manual ok/ofc-1111-IT9.pdf 07 Apr 2023 48
4 AIDETEK VC99+ Operation & user’s manual aidetek/vc99-5XM.pdf 10 Jul 2022 5
5 Toro 20334 - Personal Pace Electric Start Walk Power Mower Operator's manual toro/20334-personal-pace-electric-start-walk-power-mower-2A7.pdf 31 Aug 2022 20 1.43 Mb
6 Dell PowerConnect 7048 Getting started manual dell/powerconnect-7048-F53.pdf 23 Apr 2023 402 25.72 Mb

Similar Resources:

  • Barska

    AY11240

    (10 pages)
    1721 Wright Avenue La Verne, CA 91750Tel: 909.445.8168 Fax: 909.445.8169www.barska.com© 2008 BARSKA OpticsPrinted in China6-08.MICROSCOPEUSER MANUALMODEL AY1123640X,100X,400X,1000XCOMPOUNDMODEL AY112327X-45XSTEREO ZOOMMODEL AY1123020X,40XSTEREO TRINOCULARMODEL AY112347X-45XZOOM STEREOTRINOCULARMODEL AY1124040X,100X,400XCOMPOUND MONOCULARMODEL AY1123840X …
  • Olympus

    IX2-RFSPOT

    (4 pages)
    INSTRUCTIONSPINHOLE UNITAX7383IX2-RFSPOTThe IX2-RFSPOT has been designed to be used in place of the field iris diaphragm (FS) of a IX2 Series reflectedfluorescence illuminator (IX2-RFAL). When the IX2-RFSPOT is used, a desired pinhole* can be projected on thespecimen plane, which is convenient for canceling the cage on caged specimens. * No pinhole is provid …
  • Bresser

    junior

    (44 pages)
    Art. No. 8856000DE BedienungsanleitungEN Operating InstructionsFR Mode d’emploiNL HandleidingIT Istruzioni per l’usoES Instrucciones de usoRU Руководство по эксплуатацииCZ Návod k obsluzeMikroskopMicroscope40x-640x …
  • Microscope

    SZ

    (6 pages)
    SZ Series Stereo Microscope Please read the Instruction Manual carefully before installation and keep it for future use. INSTRUCTION MANUAL SZ Series Stereo Microscope Instruction Manual …
  • LW Scientific

    VFA-12

    (1 pages)
    Part# Description MagnificationPFA-12 Paragon on Flex Arm 10X/20XPFA-13 Paragon on Flex Arm 10X/30XPFA-24 Paragon on Flex Arm 20X/40XFlex Arm SystemsInspection SystemsThe Paragon Flex Arm stereoscope exceeds the performance demands of dental, industrialand laboratory technicians at an industry-leading price. The Flex Arm stand has spring-loaded hinge joints …
  • VWR

    VisiScope BL224T1

    (16 pages)
    VWRVersion: 1Issued: 17, 12, 2015 Model European Catalogue NumberBL224T1 630-2672 BL254T1 630-2673 Microscope series 200INSTRUCTION MANUALMANUALE D’ISTRUZIONIMANUAL DE INSTRUCCIONESMANUEL D’UTILISATIONBEDIENUNGSANLEITUNG MANUAL DE INSTRUÇÕES …

Comments, Questions and Opinions: