Argo AWR508CL Technical Service Manual

Argo AWR508CL Manual Online:

4.2, 835 votes
Argo AWR508CL User Manual
Argo AWR508CL User Guide
Argo AWR508CL Online Manual

Text of Argo AWR508CL User Guide:

  • Argo AWR508CL, 10-2. Air conditioner does not operate. 10-2-1. Circuit breaker trips (or fuse blows). A. When the circuit breaker is set to ON, it is tripped soon. (Resetting is not possible.) ● There is a possibility of ground fault. ● Check insulation resistance. If resistance value is 2MΩ or less, insulation is defective (“NO”). NO Measure insulation resistance of electrical parts in outdoor unit. NO Set circuit breaker to OFF. * Measure insulation resistance of electrical parts in indoor unit. 1 Remove inter-unit wires from terminal plate in out

  • Using the Remote Control Unit How to Install Batteries 1. Slide the cover in the direction indicated by the arrow and remove it. 2. Install two AAA alkaline batteries. Make sure the batteries point in the direction marked in the battery compartment. 3. Use a thin object such as the tip of a pen to press the ACL button. NOTE • The batteries last about six months, depe

  • Argo AWR508CL, Operation without the Remote Control Unit If you have lost the remote control unit or it has trouble, follow the steps below. 1. When the air conditioner is not running If you want to turn on the air conditioner, switch the operation selector to the OFF position, and then to the ON position. NOTE The set temperature and fan speed are automatically set at the last selection before stopping. 2. When the air conditioner is running If you want to turn off the air conditioner, switch the operation selector to the OFF position. Care a

  • Argo AWR508CL, 2-3. Other Component Specifications 115 Outdoor Unit AER508SCLA AER509SCLA AER512SCLA Thermistor (Room sensor) DTN-TKS134B Resistance kΩ 25°C 5.0 ± 3% Thermistor (Coil sensor) DTN-TKS131B Resistance kΩ 0°C 15.0 ± 2% Transformer (TR) ATR-J105 Rating Primary AC 230V, 50/60Hz Secondary 19V, 0.526A Capacity 10VA Coil resistance Ω (at 21°C) Primary (WHT – WHT): 205 ± 10% Secondary (BRN – BRN): 2.0 ± 10% Thermal cut-off temp. 150°C Indoor Unit AWR508CL AWR509CL AWR512CL Thermistor (Coil sensor TH1) PBC–41E–S4 Resistance kΩ –20°C 40.1± 5% 20°C 6.5± 5% –10°C 24.4± 5% 30°C 4.4± 5% 0°C 15.3± 5% 40°C 3.0± 5% 10°C 9.9± 5% 50°C 2.1± 5% Power Rel

  • Adjusting the Airflow Direction 1. Horizontal The horizontal airflow can be adjusted by moving the vertical vanes with your hands to the left or right. CAUTION When the humidity is high, the vertical vanes should be in the front position during the cooling or dehumidifying operation. If the vertical vanes are positioned all of the way to the right or left, condensati

  • Argo AWR508CL, 9-7. Charging additional refrigerant 9-7-1.When tubes are extended • Observe the proper amount of refrigerant as stated in this service manual or the installation manual that came with the indoor unit. Charge additional refrigerant in liquid state. ● Never charge additional refrigerant if refrigerant is leaking from the unit. Follow instructions given in "10-6. In case refrigerant is leaking" and completely carry out repairs. Only then should you recharge the refrigerant. 9-8. Retro-fitting existing systems 9-8-1 Use of existing units • Never use new refrigerant R407C for existing units which use R22. This will cause th

  • Argo AWR508CL, Remote Control Unit (Display) ON OFF 1HR. C SET TEMP (1) Operation mode COOL ....................................... MILD DRY................................ (2) Fan speed Automatic operation.............. HIGH ........................................ MEDIUM.................................. LOW......................................... ON Displayed when transmitting data Displayed when setting temperature Displayed when temperature is shown Displayed when the temperature setting is at the upper or lower allowable limit Displayed when setting timer

  • Argo AWR508CL, Indoor Unit Outdoor Unit Complete Unit Fan Motor Fan Motor Compressor Performance at 230V ~ 50Hz Rating Conditions Running Amps. A 0.12 0.24 4.04 4.4 Power Input kW 0.027 0.055 0.858 0.94 Full Load Conditions Running Amps. A 0.12 0.24 4.54 4.9 Power Input kW 0.027 0.055 0.998 1.08 Rating Conditions : Indoor Ai

  • Argo AWR508CL, Remote Control Unit (continued) NOTE The remote control unit sends the temperature signal to the air conditioner regularly at three minute intervals. If the signal from the remote control unit stops for more than ten minutes due to the loss of the remote control unit or other trouble, the air conditioner will switch to the temperature sensor which is built into the indoor unit and control the room temperature. In these cases, the temperature around the remote control unit may differ from the temperature detected at the air conditioner’s position. TIMER SELECT button No display : The timer does not operate. : The air conditioner stops at

  • Argo AWR508CL, D. Check remote control unit. E. Check fuse on the indoor PCB Ass'y. F. Check TIMER on the remote control unit. • Timer is turned ON. Check to see if or is displayed on remote control YES Cancel the timer mode. ON OK OK • Check fuse on indoor PCB Ass'y for continuity. (F) • Check operation lamp to see if light is ON. Light is OFF • Measure resistance of primary and secondary winding of transformer. (TR) • Indoor PCB Ass'y is defective. OK OK • Measure resistance of indoor and/or outdoor

  • Argo AWR508CL, 39 7. INSTALLATION INSTRUCTIONS 7-1. Installation Site Selection To prevent abnormal heat generation and the possibility of fire, don’t place obstacles, enclosures and grills in front of or surrounding the air conditioner in a way that may block air flow. AVOID: ● direct sunlight. ● nearby heat sources that may affect performance of the unit. ● areas where leakage of flammable gas may be expected. ● places where large amounts of oil mist exist. DO: ● select an appropriate position from which every corner of the room can be uniformly air-conditioned. (High on a wall is best) ● select a location that will hold the weight of the unit. ● s

  • B. Circuit breaker trips in several minutes after turning the air conditioner on. ● There is a possibility of short circuit. 10-2-2. Neither indoor nor outdoor unit runs. A. Power is not supplied. B. Check "OPERATION selector" switch in the indoor unit. C. Check transformer in indoor unit. • Measure resistance of primary and secondary winding.

  • Argo AWR508CL, 10. TROUBLESHOOTING 10-1. Check before and after troubleshooting 10-1-1. Check power supply wiring. ● Check that power supply wires are correctly connected to terminals L and N on the terminal plate in the indoor unit. 10-1-2. Check inter-unit wiring. ● Check that inter-unit wiring is correctly connected to the outdoor unit from the indoor unit. 10-1-3. Check power supply. ● Check that voltage is in specified range (±10% of the rating). ● Check that power is being supplied. 10-1-4. Check lead wires and connectors in indoor and outdoor units. ● Check that coating of lead wires is not damaged.

  • Argo AWR508CL, 11 Indoor Unit FCR512CL Controller PCB Part No. POW-K185GS-N Controls Microprocessor Control circuit fuse 250 V 3 A Remote Control Unit RCS-5PS3E Fan & Fan Motor Type Cross-flow Q'ty ... Dia. and length mm 2 ... ø130 / L180 Fan motor model ... Q'ty K48407-M01416 ... 1 No. of poles ... rpm (230 V, High) 4 ... 1,160 Nominal output W 20 Coil resistance (Ambient temp. 20°C) Ω GRY-WHT : 311±7% WHT-VLT : 97.6±7% VLT-YEL : 97.6±7% WHT-PNK : 425±7% —— Safety devices Type Internal protector Operating temp. Open °C 145±5 Close Automatic reclosing Run capacitor µF 1.5 VAC 440 Flap Motor Model M2LJ24ZE31 R

  • Argo AWR508CL, 16 Transformer (TR) ATR-H85 Rating Primary AC 235V, 50Hz Secondary 11V, 0.727A Capacity 8VA Coil resistance Ω (at 21°C) Primary (WHT – WHT): 214 ± 10% Secondary (BRN – BRN): 1.58 ± 10% Thermal cut-off temp. 145°C, 2A, 250V Thermistor (Coil sensor TH1) DHPBC-41ES-14N Resistance kΩ –20°C40.1 ±5% –10°C24.4 ±5% 0°C15.3 ±5% -10°C9.9 ±5% Thermistor (Room sensor TH2) DHKTEC-35-S6N Resistance kΩ -20°C 10 ±5% -10° 7.9 ±5% -20°C6.3 ±5% -10°C5.0 ±5% Indoor Unit AFR509CL

  • Argo AWR508CL, 67 12-4. Removing Flap Motor (1) Remove the 3 screws used to mount the top panel. (Fig. 6) (2) While unlatching the 2 tabs inside the back of the top panel, lift the top panel diagonally in the direction of the arrow.(Fig. 6) (3) Remove the 2 screws to pull off the flap motor. The arm and cam come off together with the motor. (Fig. 7) 12-5. Removing Evaporator (=Indoor Heat Exchange Coil) (1) Remove the 7 screws used to mount the blades. (Fig. 8) (2) Lift the blades in the direction of the arrow.(Fig. 8) Top panel Flap motor Screw Blade Arm Cam Screw Flap motor Screw Blades Fig.6 Fig.7 Fig.8

  • Argo AWR508CL, 8 Indoor Unit AWR509CL Controller PCB Part No. POW-K8E(A), POW-K8E(B) Controls Microprocessor Control circuit fuse 250 V 3.15 A Remote Control Unit RCS-8PS3E Fan & Fan Motor Type Cross-flow Q'ty ... Dia. and length mm 1 ... ø95 / L617 Fan motor model ... Q'ty KFV4Q-11H5P-S ... 1 No. of poles ... rpm (230 V, High) 4 ... 1,190 Nominal output W 10 Coil resistance (Ambient temp. 20°C) Ω BRN-WHT : 561.8 VLT-WHT : 197.4 VLT-ORG : 63.4 YEL-ORG : 155.7 YEL-PNK : 115.9 Safety devices Type Internal fuse Operating temp. Open °C 145±2 Close — Run capacitor µF 0.8 VAC 440 Flap Motor Ty

  • Argo AWR508CL, 19 Indoor Unit AWR508CL AWR509CL AWR512CL 58.599.5 805 177 41.0 41.0 270 Narrow tube ø6.35 (1/4") Wide tube ø9.52 (3/8") AWR508,AWR509 Wide tube ø12.7 (1/2") AWR512 Center of tubing hole (2 places) Drain hose ø18 Remote control unit 18.5 61 172.5 Unit : mm

  • Argo AWR508CL, i Important! Please Read Before Starting This air conditioning system meets strict safety and operating standards. As the installer or service person, it is an important part of your job to install or service the system so it operates safely and efficiently. For safe installation and trouble-free operation, you must: ●Carefully read this instruction booklet before beginning. ●Follow each installation or repair step exactly as shown. ●Observe all local, state, and national electrical codes. ●Pay close attention to all warning and caution notices given in thi

  • RATING CAPACITY 3.3 kW AIR FLOW RATE 700 m³/h EVAPORATOR CONDENSER ENT.TEMP. °C OUTDOOR AMBIENT TEMP. °C W.B. D.B. 25 30 35 40 43 TC 3.13 3.03 2.89 2.71 2.50 CM 1.14 1.21 1.30 1.43 1.56 21 SHC 2.14 2.10 2.03 1.94 1.84 23 SHC 2.43 2.38 2.31 2.22 2.12 15 25 SHC 2.71 2.65 2.58 2.50 2.40 27 SHC 2.99 2.93 2.86 2.71 2.50 29 SHC 3.13 3.03 2.89 2.71 2.50 31 SHC 3.13 3.03 2.89 2.71 2.50 TC 3.39 3.

  • Argo AWR508CL, 5. PERFORMANCE DATA 5-1. Performance charts 23 Indoor inlet air D.B. temp. (°C) 1.38 (13) 1.28 (12) 1.18 (11) 1.08 (10) 0.98 ( 9 ) 0.89 ( 8 ) 0.79 ( 7 ) 0.69 ( 6 ) 25 30 35 40 45 50 Outdoor inlet air D.B. temp. (°C) Low pressure at wide tube service valve MPa (kgf/cm 2 G) 0.59 ( 5 ) 0.49 ( 4 ) 0.39 ( 3 ) ■ Cooling Characteristics 9 8 7 6 5 4 3 2 1 25 30 35 40 45 50 Outdoor inlet air D.B. temp. (°C) Operating current (A) 10 Indoor inlet air D.B. temp. (°C) 32 27 19.4 32 27 19.4 32 27 19.4 ● ...... Points of Rating condition Black dots in above charts indicate the following rating conditions. Cooling: Indoor air temperature 2

  • Argo AWR508CL, 18 3. DIMENSIONAL DATA Indoor Unit FCR512CL Remote control unit 86 74 74 Center of tubing hole ø75 (4 places) Wide tube ø12.7 (1/2") Narrow tube ø6.35 (1/4") Drain hose ø26 74 74 900 86 41 41 190 680 18.5 61 172.5 Unit : mm

  • 66 12-2. Removing Side Panels (1) Remove the 3 screws attaching the left side panel. (Fig. 3) (2) Note the position of the hook on the inside of the left side panel. To disengage the hook from the slot, slide down the panel for removal. (Fig. 3) (3) Do the same procedure for the right side panel. 12-3. Access and Removal of Electrical Component Box (1) Remove the front scr

More Instructions:

DOWNLOAD

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Dell 1535 - Studio Core 2 Duo T8100 2.10GHz 4GB 320GB Service manual dell/1535-studio-core-2-duo-t8100-2-10ghz-4gb-320gb-E36.pdf 03 Sep 2022 41 1.12 Mb
2 Promate reTrax-2 Operation & user’s manual promate/retrax-2-6S6.pdf 11 Aug 2023 40
3 Acer Aspire 8930 Series Manual  acer/aspire-8930-series-874.pdf 19 May 2023 13 1.14 Mb
4 Black & Decker Slice Right EK700BK Use and care book black-decker/slice-right-ek700bk-1A5.pdf 01 Jun 2023 2 0.42 Mb
5 ALERTEGPS G200 Owner's manual alertegps/g200-K4Z.pdf 18 Oct 2023 7
6 Tascam LA-80MKII Owner's manual tascam/la-80mkii-47T.pdf 05 Dec 2023 16 1.45 Mb

Similar Resources:

  • Daikin

    RXS50E2V1B

    (13 pages)
    INSTALLATION MANUALR410A Split SeriesModels RXS50E2V1B RKS50E2V1BRXS60E2V1B RKS60E2V1BRXS71E2V1B RKS71E2V1BRYN50E2V1B RYN60E2V1BRN50E2V1B RN60E2V1BARXS50E2V1BDeutschFrançaisNederlandsEspañolItalianoΕλληνικÜPortuguesРóссêийTürkçeEnglishMontaj kýlavuzlarý R410A Split serisiInstallation manualR410A Split seriesInstallationsanleitungSpli …
  • Morgan

    MAC-080 DANDELION

    (8 pages)
    USER MANUALMAC-080 DANDELIONE-mail: [email protected] ExpansionServices bywww.dksh.com.myfacebook.com/morganappliancesPortable AirConditioner …
  • Daikin

    FCQ24MVJU

    (16 pages)
    MODELSCeiling-mounted Cassette type (Multi flow model)FCQ24MVJUFCQ30MVJUFCQ36MVJUFCQ42MVJUSPLIT SYSTEM Air ConditionersINSTALLATION MANUALRead these instructions carefully before installation. Keep this manual in a handy place for future reference. This manual should be left with the equipment owner.00_CV_3PN06240-3E (A4 Letter).fm Page 1 Tuesday, Septemb …
  • TJERNLUND

    PAI-1G

    (19 pages)
    INSTALLATION INSTRUCTIONSIN-FORCERTMMODELSPAI-1G & PAI-2GPAI-10 & PAI-2OOWNER'S INSTRUCTIONS, DO NOT DESTROYCopyright © 2001, Tjernlund Products, Inc. All rights reserved. P/N 8504038THIS DEVICE MUST BE INSTALLED BY A QUALIFIED PERSON.READ INSTRUCTIONS CAREFULLY PRIOR TO INSTALLATION AND OPERATION OF THE AIR INTAKE SYSTEM.REV. A 5/01TJERNLUND …
  • Hisense

    AVWW-76FKFW

    (69 pages)
    Models:Water Source Units;AVWW-76FKFW AVWW-96FKFW AVWW-114FKFW AVWW-136FKFW AVWW-154FKFW AVWW-170FKFW AVWW-190FKFWAVWW-210FKFW AVWW-228FKFWAVWW-250FKFW AVWW-268FKFW AVWW-286FKFW AVWW-304FKFWAVWW-326FKFWAVWW-344FKFW AVWW-360FKFW AVWW-380FKFW AVWW-400FKFW AVWW-418FKFW AVWW-440FKFW AVWW-456FKFW AVWW-476FKFW AVWW-494FKFW AVWW-516FKFW AVWW-534FKFW AVWW-550FKFW AV …
  • Gree

    FP-51XD-E

    (18 pages)
    FP-51XD-EFP-51XDS-EFP-51XDM-EFP-51XDSM-EFP-68XD-EFP-68XDS-EFP-68XDM-EFP-68XDSM-EApplicable Models : Change for lifeCassette Type Fan Coil Unit Thank you for choosing commercial or household air conditioners.Please read this Owner’s Manual carefully before operation and retain it for future reference. If you have lost the Owner's Manual, please contact …

Comments, Questions and Opinions: