  • Chromalox CAS-20CM, (Supersedes PQ435) PQ435-1 cas 161-562795-001 JUNE, 1994 4 and Installation, Operation RENEWAL PARTS IDENTIFICATION Type CAS-20CM Electric Steam Boiler (Standard Trim is 100 PSI — 0-90 PSI Operating Pressure Range) © 2010 Chromalox, Inc. Model Electric Capacity BHP Rating Voltage Phase Amperes Drawn Contactor 20 kW 2.0 208 1 96 50A, 4 Pole 16/20 kW 1.6/2.0 208/230 3 45/51 60A, 3 Pole CAS-20CM 20 kW 2.0 240 1 84 50A, 4 Pole 20 kW 2.0 346 3 34 40A, 3 Pole 20 kW 2.0 380 1 53 60A, 2 Pole 20 kW 2.0 480 3 24 30A, 3 Pole Note: Control circuit 120V Boiler Serial No. ___________________________________________

  • Chromalox CAS-20CM, INSTALLATION WARNING: To avoid electrical shock hazard, boilers must be suitably grounded to earth. Note: Chromalox boilers are pre-tested before shipment; no inter- nal piping or wiring is necessary. WARNING: Substitution of components or modification of wiring without prior consent of Chromalox voids warranty. 1. Bolt unit securely to level floor or platform. Note: A minimum distance of 18 inches from wall, other equipment, etc. must be allowed for removal of the elements. 2. Complete all piping to boiler. Connect water line to tagged fit- ting on the motor and pump assembly if used, or to tagged fit- ting on water control feeder. 3. When any type of feed other than a pu

  • SOLID STATE FLOATLESS LIQUID LEVEL CONTROL SYSTEM This boiler is equipped with a solid state, floatless liquid level control which operates by sensing the electrical resistance of water. Note: Control will not work with de-ionized or demineral- ized water. Two probes are provided. The HI probe activates and controls the feed water relay. The LOW probe is a safety back-up probe that t

  • Chromalox CAS-20CM, MAINTENANCE WARNING: Hazard of Electric Shock. Disconnect all power before working on boiler. 1. A monthly inspection should be made to ensure that all electri- cal connections are tight. 2. When steam or water leaks are observed, fittings should be tightened immediately. 3. Every four months, the Solid State Liquid Control probes should be checked for deposits and cleaned if necessary. Remove deposits from probe and teflon sleeve. This is accom- plished by removing the inspection plate and with the use of a standard spark plug wre

  • Chromalox CAS-20CM, -5- RENEWAL PARTS IDENTIFICATION HEATING ELEMENTS Description Part Number 20kW 240V 1PH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 155-300121-006 20kW 208V 1-3PH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 155-554735-023 16/20kW 208/230V 3PH . . . . . . . . . . . . . . . . . . . . . . . . . . . . 155-554735-024 20kW 346V 1-3PH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 155-554735-051 20kW 380V 1PH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 155-554735-042 20kW 480V 3PH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 155-554735-030 Element Gasket

  • Chromalox CAS-20CM, 2150 N. RULON WHITE BLVD., OGDEN, UT 84404 Phone: 1-800-368-2493 www.chromalox.com Limited Warranty: Please refer to the Chromalox limited warranty applicable to this product at http://www.chromalox.com/customer-service/policies/termsofsale.aspx.

Related Products and Documents (Boiler):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Uniden Grant XL Operating manual uniden/grant-xl-75B.pdf 08 Aug 2022 21
2 Vetek FR-MS Operation & user’s manual vetek/fr-ms-I9N.pdf 10 Feb 2024 5
3 Best EB15 Specification sheet best/eb15-GM7.pdf 21 Nov 2023 1 0.13 Mb
4 Hussmann IMPACT M5NE Datasheet hussmann/impact-m5ne-534.pdf 30 May 2023 6
5 Asus BT1AD Specification asus/bt1ad-Q1F.pdf 03 Nov 2022 2 0.52 Mb
6 DeWalt DW083-XE Instruction manual dewalt/dw083-xe-J95.pdf 12 Mar 2023 12

Similar Resources:

  • TES

    TES Series

    (15 pages)
    DNAGNITAREPO,NOITALLATSNIROFSNOITCURTSNIECIVRESTES®SEIRESRELIOBDERIF-,reliobnonoitamrofnignikeesnehW.rotcartnocgnitaehruoyllac,reliobotsriaperroecivresroF.lebaLgnitaRnonwohssarebmuNlaireSdnarebmuNledoMrelioBedivorprebmuNledoMrelioBrebmuNlaireSrelioB etaDnoitallatsnIrotcartnoCgnitaeHrebmuNenohPsserddAGASgGASASGAS/OIL …
  • Burco

    C10STHF

    (12 pages)
    083184001 ISS 4 User Instruction Manual Electric Catering Urn Please read and keep these instructions These instructions cover the Burco 10, 20 and 30 Litre electric catering urns SKU’s 444448528, 444448529 & 444448530 C10STHF C20STHF C30STHF 444448528 444448529 444448530 Glen Dimplex UK Ltd., trading as, Glen Dimplex Heating & …
  • Allied Engineering

    6MSE

    (20 pages)
    PN4330651 INSTALLATION AND SERVICE MANUAL Models 6MSE to 54MSE for Hydronic Heating 6 kW to 54 kW, 208 Vac to 600 Vac, Single or Three Phase MINI-STAR® ELECTRIC BOILER WARNING Risk of electric shock. This unit may be connected to more than one electrical circuit. Turn off all electrical supply circuits before servicing. IMPORTANT • The …
  • State Water Heaters

    ASME SW 37-670

    (20 pages)
    PRINTED 0110 316393-000Instruction ManualPLACE THESE INSTRUCTIONS ADJACENT TO BOILER AND NOTIFY OWNER TO KEEP FOR FUTURE REFERENCE.COMMERCIAL ELECTRIC BOILERS Thank you for buying this energy efficient boiler from us. We appreciate your confidence in our products.MODELS SW 37-670INSTALLATION - OPERATION - SERVICE - MAINTENANCE - LIMITED WARRANTYA DI …
  • Ariston

    GENUS PREMIUM EVO HP

    (64 pages)
    GENUS PREMIUM EVO HP GENUS PREMIUMEVO HP 45/65/85/100/115/150Installation and Servicing InstructionsES - Instrucciones de instalación y de utilizaciónCALDERA MURAL A GASA CONDENSACIÓNWALL-HUNG CONDENSINGGAS BOILER …
  • Alpha

    Alpha CD18

    (4 pages)
    Supplementary LPG BoilerInstructionsNepicar House, London Road,Wrotham Heath, Sevenoaks,Kent TN15 7RSFor Technical help or for Service call ...ALPHA HELPLINETel: 0870 3001964Alpha CD18/24/30/32Wall Mounted, Fan Assisted, Room Sealed, Gas FiredHigh Efficiency Condensing BoilersAlpha CD18S British Gas G.C. No. 41 532 13Alpha CD24C British Gas G.C. No. 47 532 …

Comments, Questions and Opinions: