Manualios.com

Audiovox MA200C Installation Manual And Owner's Manual

  • MA200C Security System
  • maPrLe7ynJLMw
  • Installation Manual And Owner's Manual
  • PDF / Adobe Acrobat Reader
  • 12

Audiovox MA200C Manual Online:

3.4, 1437 votes
Audiovox MA200C User Manual
Audiovox MA200C User Guide
Audiovox MA200C Online Manual

Text of Audiovox MA200C User Guide:

  • 2 MOUNTING THE SIREN/CONTROL MODULE 1. Choose a location that is away from hot and mov- ing parts considering the Red wire length must be connected to the to the positive terminal of the bat- tery. Prevent access to the siren as much as pos- sible, by mounting in a hidden location. Typical locations are underneath the gas tank, seat or ex- terior body panels. Avoid areas which a

  • Audiovox MA200C, 3 BLACK (LONG): Using the attached wire lug, connect the Black (long) wire of the siren to the negative terminal of the battery or a good ground source. BLACK (SHORT): Stretch the short Black antenna wire as long as pos- sible, avoiding metal contact if possible. This is the an- tenna wire for the alarm system; route it as high as possible! BROWN/BLACK: This wire is used when an additional horn is connected to the alarm system. To connect an additional horn, a relay is required (included in the kit). The relay may be used as a horn, park light or starter kill. The relay, when- ever possible, should be protected from water, engine heat or grease. NOTE: Additional

  • 4 CONNECTING THE RELAY (HORN FEATURE) IMPORTANT! The relay has been shipped with the BLACK wire loaded into terminal 87a of the Relay Socket. The wire must be removed from this location and placed into the outer terminal of the Relay Harness 87. 1. Connect the ORANGE wire from the relay harness to the BROWN/BLACK wire from the main harness. Be sure to insulate this sp

  • Audiovox MA200C, 5 CONNECTING THE RELAY (STARTER/IGNITION) IMPORTANT ! When using the relay to disable the starter, leave the BLACK wire in ter- minal 87a of the relay connector in the location shown in the Figure 5. 1. Connect the ORANGE wire from the relay harness to the ORANGE wire from the siren harness. Be sure to insulate this splice with electrical tape. Refer to Figure 5. Be certain to remove the series resistor before connecting the relay. 2. Gain access to the wires coming from the ignition switch. Connect the RED wire from the relay h

  • Audiovox MA200C, 6 CONNECTING THE RELAY (HEAD LAMP FLASH FEATURE) IMPORTANT! When using the relay to flash the vehicle’s parking lights, unload the BLACK wire from terminal 87A of the relay harness and load it into terminal 87. Refer to Figure 6. 1. Connect the ORANGE wire from the relay harness to the WHITE wire from the main harness. Be sure to insulate this splice with electrical tape. Refer to Figure 6. 2. Gain access to the wires coming from the back of the head lamp socket. Switch the head lamp on, and locate the wire that measures + 12 volts on the logic probe. Switch the head lamp off, and verify that this wire now measures 0 volts. Cut this wire in half. Connec

  • Audiovox MA200C, 7 2. Turn the ignition "ON" then "OFF" 5 times. The system will sound a long chirp to confirm entry into the program mode. 3. Press the "LEFT" button of each transmitter to be programed (up to Two Transmitters). The siren will chirp to confirm each transmitter is now programmed. 4. Turn the ignition "ON" then "OFF" to exit the program mode. The siren will sound a long chirp to confirm the exit from the program mode. Final Touches If there are any wires from the main harness that you did you not connect, simply because

  • Audiovox MA200C, 8 NOTE: If the alarm issues three warnings within 15 seconds, the siren will sound a regular alarm tone which lasts for 30 seconds. After 30 seconds, the siren will automatically stop and the alarm will arm itself. OPERATING THE SYSTEM Operation of the system is described in this section. Sounds that can be produced by the alarm system will consist of siren chirp tones or sounds from the motorcycle horn (optional relay). The equivalent sounds are shown in parenthesis. Also if an additional optional relay was included in the package and

  • Audiovox MA200C, 9 To activate the panic feature: 1. Press and hold button 1 on the keychain transmitter for 3 seconds. 2. The alarm will sound, and continue to sound for 30 seconds. 3. To silence the alarm before the 30-second shut- down, press and hold button #2 on the keychain transmitter. WARNING: In most areas, it is illegal to activate the alarm while the motorcycle is moving. For the safety of your passengers and other motorists, do not activate the alarm while your motorcycle is in motion. Override Function Operation : The override function is provided in the event of an emergency; a lost or a malfunctioning transmitter. The override function allows the user to disarm the system. NOTE: Th

  • Audiovox MA200C, 10 Replacing the Transmitter Battery The keychain transmitters have a small, red LED visible through the top cover. This LED can be used to indicate battery condition. You will also notice a decrease in effective transmitter range as the battery deteriorates. The replacement battery must be a 12 volt type GP27A or equivalent. To replace the transmitter battery: 1. Remove the small phillips head screw(s) from the bottom of the transmitter, and carefully pry the top cover (button side) away from the transmitter. 2. Remove the discharged battery, making note of the orientation of the + and - contacts

  • Audiovox MA200C, 11 TROUBLESHOOTING: Symptom: The Transmitters will not program to the control module. Check: 1. Verify that the 1 Amp fuse in the red wire from the siren control module is in good condition. Replace it if it is blown. 2. Verify that the connections of the red and black wires have been made according to the wiring section of this manual. 4. The battery in the motorcycle and/or transmitter is weak or dead. Change or replace the batteries as needed. Symptom: The alarm will not arm and disarm using the keychain transmitter. Check: 1. Verify the transmitter batt

Related Products and Documents (Security System):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Asus PU500CA Operation & user’s manual asus/pu500ca-8E7.pdf 27 Oct 2022 100 5.76 Mb
2 Marbella M880 Operation & user’s manual marbella/m880-51Y.pdf 31 Oct 2023 48
3 Kyocera KM-1820 Specifications kyocera/km-1820-P7E.pdf 04 Dec 2023 1
4 Peak PKC0BU7 Owner's manual and warranty peak/pkc0bu7-U55.pdf 26 Jul 2022 10
5 Shimano RD-M760 Service instructions shimano/rd-m760-34M.pdf 31 Dec 2023 1
6 Walker MDD Owner's manual walker/mdd-P13.pdf 10 Dec 2023 80 3.32 Mb

Similar Resources:

  • Cisco

    5505 - ASA Firewall Edition Bundle

    (2 pages)
    Before you install the Cisco ASA 5505 Adaptive Security Appliance, please read the Regulatory Compliance and Safety Information for the Cisco ASA 5500 Series Adaptive Security Appliance document on Cisco.com or in the product CD that ships with the chassis.1. Verifying the Package ContentsCisco ASA 5505Power cable(US shown)Power supply adapterBlue console ca …
  • SILENTRON

    5034 SR-P

    (4 pages)
    1Dichiarazione di conformità CE. Silentron s.p.a. dichiara soo la propria responsabilità che i prodo descri nel presente manuale sono conformi ai requisi stabili dalle Direve e relave Norme e/o speciche tecniche che seguono:1) Direva CE 1999/5/CE - R&TTE - del 9 marzo 1999 (in Italia D.L. 9/05/2001 n. 269) riguardante le appa …
  • Security Brands

    RIDGE 2.0

    (6 pages)
    QUICK START GUIDE1 of 62Make sure you have all items shown here. (Screwdriver not shown)9-V BatteryMust be installed before use.Reset ButtonFor performing reset procedures on keypadSTART HEREKeypad Unit Transceiver 9-V Battery Key Carriage Bolt( 4x )Hex Nut( 4x )What’s what?Important components labeledTransceiverShown with cover removed.Internal wiring not …
  • Venner

    DruGuardian

    (7 pages)
    Manufactured for:Venner Medical (Singapore) Pte Ltd35 Joo Koon Circle, Singapore 629110www.vennermedical.comEU Authorised Representative:Venner Medical Technologies SAOsprey House, Old Street, St Helier Jersey JE2 3RGwww.vennermedical.comen OPERATING MANUAL™ …
  • Seneca

    MyALARM2

    (16 pages)
    1 1. CONTENUTO DELLA CONFEZIONE Nella confezione è incluso: Nr. 1 MyALARM2 Nr. 1 Alimentatore AC/DC con uscita 12V Nr. 1 CD contenente: software di configurazione manuali installazione manuali utente guida rapida Nr. 1 cavo miniUSB Nr. 1 antenna GSM Nr. 1 supporto per guida DIN completo di viti e tasselli Nelle versioni MyALARM2 …
  • Samsung

    SDE-5003

    (2 pages)
    For your safety All-In-One Security KitsWWW.SOLTECHSECURITY.COMFIRST EDITION 06-2012SDE-5003• 16CH real time DVR with built-in 1TB HDD (SATA)• Free DDNS service for on the go remote monitoring• 8 ea of IP65 weather proof night vision (15m) camera• Simple user interface for quick setup• Remote web viewer/mobile phone viewer support16 Chan …

Comments, Questions and Opinions: