Manualios.com

Axminster AWC10HP Operation & User’s Manual

Axminster AWC10HP Manual Online:

4.25, 1645 votes
Axminster AWC10HP User Manual
Axminster AWC10HP User Guide
Axminster AWC10HP Online Manual

Text of Axminster AWC10HP User Guide:

  • Axminster AWC10HP, AWC10HP Air Compressor Direct drive, oil lubricated, ducted air cooled, portable compressor A small, direct drive, oil lubricated, ducted air cooled, portable compressor. Great in the workshop or around the home for low volume air tools such as air staplers and nailers, air brush painting, occasional tyre inflation etc. Quite a robust little unit with a cast iron cylinder for long life. Twin pressure gauges monitor receiver and output pressures. Supplied with four rubber feet, top grab handle for easy mobility, output pressure control valve and a 1/4” BSP female quick release fitting. Axminst

  • Index of Contents Declaration of Conformity 02 Page No Index of Contents............................................................................................................................................................................................. 02 Declaration of Conformity..........................................................................

  • Axminster AWC10HP, What’s Included 03 Safety Precautions Good Working Practices/Safety The following suggestions will enable you to observe good working practices, keep yourself and fellow workers safe and maintain your tools and equipment in good working order. WARNING!! KEEP TOOLS AND EQUIPMENT OUT OF THE REACH OF YOUNG CHILDREN Air Powered Tools 1. Always perform pre-operation checks before starting up the compressor. 2. Never leave inflammable objects or materials near to the compressor. 3. Always check oil level before using the compressor. 4. The cylinder,

  • Axminster AWC10HP, 04 Remove the compressor from the packaging and check for damage or missing parts. Report any problems to Axminster Power Tool Centre’s Customer Services Department. Fit the rubber feet, air filter and quick release coupling. (see instructions below) Remove the oil filler plug (See fig 2) and fill with a good quality compressor oil, (see our catalogue) until the level is in line with the circle marked on the oil level indicator. (See page 05) The compressor is now ready for use. Specification (AWC10HP Air Compressor) Assembly Instru

  • Axminster AWC10HP, 05 Assembly Instructions Illustration and Parts Description of Air Compressor Oil level indicator Pressure relief valve Pressure regulator adjuster Tank pressure gauge (A) & Outlet pressure gauge (B) Oil drain plug Fitting the quick release coupling Wrap some PTFE tape (A) around the outlet thread and screw on the 1/4" BSP female coupling (B) and, lightly tighten with a spanner. (DO NOT OVERTIGHTEN) A B A B Closed Open

  • Axminster AWC10HP, 06 Illustration and Parts Description of Air Compressor Fig 1 Tank On/Off switch Handle Wheel Rubber foot Motor cover Cylinder Pressure adjuster Outlet pressure gauge Tank pressure gauge Pressure switch Pressure relief valve Crankcase Water drain valve

  • Operating Instructions 08 The outlet air pressure can be regulated by rotating the regulator knob clockwise to increase the pressure and anticlockwise to reduce it. Do not leave the regulator set at maximum setting unnecessarily; reduce the setting by about two turns after finishing and then re-set to the required pressure when starting work again. Connect t

  • Axminster AWC10HP, Maintenance 09 Fig 5 Fig 6 Fig 7 Fig 8 Daily: Drain water from tank. (See fig 5) Weekly: Check oil level and top-up if necessary. (See fig 6-8) Monthly: Un-clip and remove the air inlet filter outer casing and clean the filter element with the following: (See fig 7) (a) Compressed air. (b) Wash in soapy water and left to dry. Do not use the compressor without the air filter fitted. Six Monthly: Change the oil. With the oil still warm remove the oil filler plug, place a suitable container under the drain plug and drain the oil right out. Replace drain plug and refill to the level mark on the sight glass (See figs 6-

  • Axminster AWC10HP, Tank pressure drops. The pressure switch valve leaks when the compressor is stopped Leakage at connections or joints. Non-return valve seal dirty or defective Set the compressor to maximum pressure. Switch off and brush a soapy water solution onto all connections and joints. Look for bubbles. Tighten connections or joints where leakage is visible. Release any air in tank. Remove non-return valve seal. If necessary, replace the seal. Re-assemble Press the reset button on the current over-load and wait for a minute. The motor will run when it has cooled Wait

Related Products and Documents (Air Compressor):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Adaptec 71605Q Datasheet adaptec/71605q-JU7.pdf 11 Mar 2023 2 0.9 Mb
2 Toastess TCP709 Instruction booklet toastess/tcp709-4X4.pdf 15 Dec 2023 5 0.18 Mb
3 Macro Machines Storage Strip Manual  macro-machines/storage-strip-CHJ.pdf 21 Nov 2023 4
4 Traxon Allegro Dot M/L Direct View Installation manual traxon/allegro-dot-ml-direct-view-JGA.pdf 13 Apr 2024 23
5 Monoprice 36373 Operation & user’s manual monoprice/36373-C41.pdf 18 Oct 2023 13
6 Heatcraft 1/2-6 HP Technical manual heatcraft/12-6-hp-2AO.pdf 31 Dec 2023 32

Similar Resources:

  • Airmax

    ProAir 4

    (2 pages)
    airmaxeco.com | 866-424-7629 | P.O.Box 38 | Romeo, MI 48065ProAir™ 4 DiuserFor All PondSeries™ and LakeSeries™ Aeration SystemsItem # 5101664INSTALLATION INSTRUCTIONSProduct Contents .........................2Installation ..............................3Maintenance .............................4Troubleshooting ..........................4Replacem …
  • Rolls

    CL151 GLC

    (2 pages)
    USER GUIDEROLLS CORPORATIONSALT LAKE CITY, UTAH1/04CL151 GLCCompressor/Limiter/GateSPECIFICATIONSMax Input: XLR: -10 dBm Balanced 1/4": +14 dBV BalancedMax Out: +14 dBV BalancedNoise Floor: -72 dBV, Out Level Min, Gate OffPhantom Power: 12 VDCFrequency Response: 10 Hz - 30 kHz, +0 -3 dBGate Release Time: 150 mS - 1 SGate Attack Time: …
  • Grizzly

    G0471

    (32 pages)
    COPYRIGHT © JULY, 2005 BY GRIZZLY INDUSTRIAL, INC.WARNING: NO PORTION OF THIS MANUAL MAY BE REPRODUCED IN ANY SHAPE OR FORM WITHOUT THE WRITTEN APPROVAL OF GRIZZLY INDUSTRIAL, INC.#EW7400 PRINTED IN CHINAAIR COMPRESSORMODEL G0471INSTRUCTION MANUAL …
  • Kobalt

    0320541

    (20 pages)
    kobalttools.com1AB13664C KOBALT® and the K Design® are registered trademarks of LF, LLC. All Rights Reserved.5 GAL. ELECTRIC AIR COMPRESSORITEM #0476123MODEL #0320541Français p. 14Español p. 27Questions, problems, missing parts? Before returning to your retailer, call our customer service department at 1-888-3KOBALT (1-888-356-2258), 8 a.m. - 8 p. …
  • Husky

    D28752

    (60 pages)
    ESPAÑOL . . . . . . . . . . . . . . .21-39FRANÇAIS . . . . . . . . . . . .40-60Questions? 1-800-888-2468Part No. D28752 Rev. 1 05/21/03READ AND SAVE THESE INSTRUCTIONSAir CompressorOperator’s ManualModel No. Y6010 …
  • Strobl

    STROCOMP 400

    (80 pages)
    G870455_0012009/07/jbrg-08Originalbedienungsanleitung Teil 1 I/1 Teil 2 II/1Original operating manual Part 1 I/3 Part 2 II/9Notice d’utilisation d’origine Partie 1 I/5 Partie 2 II/17Manual de instrucciones original Parte 1 I/7 Parte 2 II/26Originele gebruiksaanwijzing Deel 1 I/9 Deel 2 II/35Oryginalna instrukcja eksploatacji Części 1I/11Częś …

Comments, Questions and Opinions: