Manualios.com

Cisco WS-C4003 - Catalyst 4000 Chassis Switch Software Configuration Manual

  • WS-C4003 - Catalyst 4000 Chassis Switch Switch
  • mae.RT5SYoC5U
  • Software Configuration Manual
  • PDF / Adobe Acrobat Reader
  • 510

Cisco WS-C4003 - Catalyst 4000 Chassis Switch Manual Online:

4.2, 2282 votes
Cisco WS-C4003 - Catalyst 4000 Chassis Switch User Manual
Cisco WS-C4003 - Catalyst 4000 Chassis Switch User Guide
Cisco WS-C4003 - Catalyst 4000 Chassis Switch Online Manual

Text of Cisco WS-C4003 - Catalyst 4000 Chassis Switch User Guide:

  • Cisco WS-C4003 - Catalyst 4000 Chassis Switch, Contents xiii Software Configuration Guide—Catalyst 4000 Family, Catalyst 2948G, Catalyst 2980G, Releases 6.3 and 6.4 78-12647-02 Adding IP Addresses to the IP Permit List 17-2 Enabling IP Permit List 17-3 Disabling the IP Permit List 17-4 Clearing an IP Permit List Entry 17-4 CHAPTER 18 Configuring Protocol Filtering 18-1 Understanding How Protocol Filtering Works 18-1 Default Protocol Filtering Configuration 18-2 Configuring Protocol Filtering 18-2 Configuring Protocol Filtering 18-3 Disabling Protocol Filtering 18-3 PART 6 Monitoring and Managing the

  • Cisco WS-C4003 - Catalyst 4000 Chassis Switch, 28-4 Software Configuration Guide—Catalyst 4000 Family, Catalyst 2948G, Catalyst 2980G, Releases 6.3 and 6.4 78-12647-02 Chapter 28 Modifying the Switch Boot Configuration Default Switch Boot Configuration When the switch boots up, if any of the files specified in the CONFIG_FILE environment variable are valid configuration files, the configuration in NVRAM is erased and the system uses the specified configuration file to configure the switch. If multiple valid configuration files are specified, each configuration

  • 31-9 Software Configuration Guide—Catalyst 4000 Family, Catalyst 2948G, Catalyst 2980G, Releases 6.3 and 6.4 78-12647-02 Chapter 31 Working with Configuration Files Clearing the Configuration This example shows how to clear the configuration on a specific module: Console> (enable) clear config 2 This command will clear module 2 configuration. Do you want to continue (y/n) [n]? y

  • Cisco WS-C4003 - Catalyst 4000 Chassis Switch, 19-6 Software Configuration Guide—Catalyst 4000 Family, Catalyst 2948G, Catalyst 2980G, Releases 6.3 and 6.4 78-12647-02 Chapter 19 Checking Port Status and Connectivity Changing the Login Timer This example shows how to Telnet from the switch to the remote host labsparc: Console> (enable) telnet labsparc Trying 172.16.10.3... Connected to labsparc. Escape character is '^]'. UNIX(r) System V Release 4.0 (labsparc) login: Changing the Login Timer The login timer is the number of minutes after which an idle session is disconnected. To change the logout timer value, perform this ta

  • Cisco WS-C4003 - Catalyst 4000 Chassis Switch, A-4 Software Configuration Guide—Catalyst 4000 Family, Catalyst 2948G, Catalyst 2980G, Releases 6.3 and 6.4 78-12647-02 Appendix A Acronyms I ICD International Code Designator ICMP Internet Control Message Protocol IDP Initial Domain Part IGMP Internet Group Management Protocol ILMI Integrated Local Management Interface IMPL initial microprogram load IP Internet Protocol IPC interprocessor communication IPX Internetwork Packet Exchange ISL Inter-Switch Link ISO International Organization of Standardization K KDC Key Distribution Center L LAN local area network LANE LAN Emulation LAT local-area transport LCP Link Control Protocol LEC LAN Emulation Client LECS LAN

  • Cisco WS-C4003 - Catalyst 4000 Chassis Switch, Index IN-12 Software Configuration Guide—Catalyst 4000 Family, Catalyst 2948G, Catalyst 2980G, Releases 6.3 and 6.4 78-12647-02 running configuration downloading via rcp 31-6 S sc0 interface assigning IP address 3-5 configuring 3-5 DHCP and 3-10 overview 3-1, 3-4 RARP and 3-10 VLAN assignment 10-2 secure shell encryption See SSH security configuring 17-1 configuring passwords 27-15 IP permit list 17-1 set spantree portcost command 7-15 Simple Network Management Protocol See SNMP sl0 interface configuring 3-8 console port and 3-8 overview 3-1 SLIP interface See sl0 interface SNMP benefits 23-7 c

  • Cisco WS-C4003 - Catalyst 4000 Chassis Switch, 35-6 Software Configuration Guide—Catalyst 4000 Family, Catalyst 2948G, Catalyst 2980G, Releases 6.3 and 6.4 78-12647-02 Chapter 35 Configuring NTP Configuring NTP To enable the daylight saving time clock adjustment following the U.S. rules, perform this task in privileged mode: This example shows how to set the clock adjusted for Pacific Daylight Time following the U.S. standards: Console> (enable) set summertime enable PDT Console> (enable) set summertime recurring Summertime is enabled and set to 'PDT' Console&g

  • 7-11 Software Configuration Guide—Catalyst 4000 Family, Catalyst 2948G, Catalyst 2980G, Releases 6.3 and 6.4 78-12647-02 Chapter 7 Configuring Spanning Tree Understanding PVST+ and MISTP Modes Figure 7-7 Port 2 in Disabled State A disabled port performs as follows: • Discards frames received from the attached segment. • Discards frames switched from another port

  • 27-53 Software Configuration Guide—Catalyst 4000 Family, Catalyst 2948G, Catalyst 2980G, Releases 6.3 and 6.4 78-12647-02 Chapter 27 Configuring Switch Access Using AAA Configuring Authorization all: - - Console: -------- Primary Fallback ------- -------- exec: tacacs+ deny enable: tacacs+ deny commands: c

  • 12-8 Software Configuration Guide—Catalyst 4000 Family, Catalyst 2948G, Catalyst 2980G, Releases 6.3 and 6.4 78-12647-02 Chapter 12 Configuring Dynamic Port VLAN Membership with VMPS Dynamic Port VLAN Membership with VMPS Configuration Examples ! !vmps-port-group <group-name> ! device <device-id> { port <port-name> | all-ports } ! vmps-port-group WiringCloset1 de

  • Cisco WS-C4003 - Catalyst 4000 Chassis Switch, 28-5 Software Configuration Guide—Catalyst 4000 Family, Catalyst 2948G, Catalyst 2980G, Releases 6.3 and 6.4 78-12647-02 Chapter 28 Modifying the Switch Boot Configuration Setting the Configuration Register The following boot methods are supported: • ROM monitor—Use the rommon keyword to keep the switch in ROM-monitor mode at startup. • Bootflash—Use the bootflash keyword to cause the switch to boot from the first image stored in the onboard Flash. • System—Use the system keyword to boot from the im

  • Cisco WS-C4003 - Catalyst 4000 Chassis Switch, 7-36 Software Configuration Guide—Catalyst 4000 Family, Catalyst 2948G, Catalyst 2980G, Releases 6.3 and 6.4 78-12647-02 Chapter 7 Configuring Spanning Tree Configuring Spanning Tree BPDU Skewing Portfast bpdu-filter disabled for bridge. Uplinkfast disabled for bridge. Backbonefast disabled for bridge. Summary of connected spanning tree ports by vlan VLAN Blocking Listening Learning Forwarding STP Active ----- -------- --------- -------- ---------- ---------- 1 6 4 2 0 12 Blocking

  • Cisco WS-C4003 - Catalyst 4000 Chassis Switch, 5-6 Software Configuration Guide—Catalyst 4000 Family, Catalyst 2948G, Catalyst 2980G, Releases 6.3 and 6.4 78-12647-02 Chapter 5 Configuring Gigabit Ethernet Switching Default Gigabit Ethernet Configuration Default Gigabit Ethernet Configuration Table 5-7 shows the Gigabit Ethernet default configuration. Configuring Gigabit Ethernet These sections describe how to configure Gigabit Ethernet switching ports on the Catalyst enterprise LAN switches: • Setting the Port Name, page 5-7 • Setting the Port Priority Level, page 5-7 • Configuring Flow Control on Gigabit Ethernet Port

  • 7-7 Software Configuration Guide—Catalyst 4000 Family, Catalyst 2948G, Catalyst 2980G, Releases 6.3 and 6.4 78-12647-02 Chapter 7 Configuring Spanning Tree How Spanning Tree Protocols Work Blocking State A port in the blocking state, such as port 2 in Figure 7-3, does not participate in frame forwarding. After initialization a BPDU is sent to each port in the switch. A switch initial

  • Cisco WS-C4003 - Catalyst 4000 Chassis Switch, 27-6 Software Configuration Guide—Catalyst 4000 Family, Catalyst 2948G, Catalyst 2980G, Releases 6.3 and 6.4 78-12647-02 Chapter 27 Configuring Switch Access Using AAA Understanding How Authentication Works Using Kerberized Login Procedure You can use a Kerberized Telnet session if you are logging in through the in-band management port. After the Telnet client and services have been Kerberized, the following process takes place when a user attempts to Telnet to the switch: 1. The Telnet client asks the user for the username and issues a request for a TGT to the KDC on the Kerberos server. 2. The KDC creates the TGT, which cont

  • Cisco WS-C4003 - Catalyst 4000 Chassis Switch, 29-7 Software Configuration Guide—Catalyst 4000 Family, Catalyst 2948G, Catalyst 2980G, Releases 6.3 and 6.4 78-12647-02 Chapter 29 Working with System Software Images Downloading System Software Images to the Switch Using rcp Step 3 Download the software image from the rcp server using the copy rcp flash command. When prompted, enter the IP address or host name of the rcp server and the name of the file to download. On those platforms that support the Flash file system, you are also prompted for the Flash device to which to copy the file and the destination filename. Note The Catalyst 4

  • Cisco WS-C4003 - Catalyst 4000 Chassis Switch, 35-3 Software Configuration Guide—Catalyst 4000 Family, Catalyst 2948G, Catalyst 2980G, Releases 6.3 and 6.4 78-12647-02 Chapter 35 Configuring NTP Configuring NTP Configuring NTP in Broadcast-Client Mode Configure the switch in NTP broadcast-client mode if an NTP broadcast server, such as a router, regularly broadcasts time-of-day information on the network. To compensate for any server-to-client packet latency, you can specify an NTP broadcast delay (a time adjustment factor for the receiving of broadcast packets by the switch). To enable NTP broad

  • Cisco WS-C4003 - Catalyst 4000 Chassis Switch, 2-5 Software Configuration Guide—Catalyst 4000 Family, Catalyst 2948G, Catalyst 2980G, Releases 6.3 and 6.4 78-12647-02 Chapter 2 Using the Command-Line Interface Command-Line Editing To use the partial-keyword-lookup function, enter ? to display a list of commands that begin with a specific set of characters. Do not insert a space between the last letter of the variable and the question mark (?). For example, enter co? at the privileged prompt to display a list of commands that start with co. The system displays all commands that begin with co as follows: Console> (enable) co? configure Configure system from netw

  • Cisco WS-C4003 - Catalyst 4000 Chassis Switch, Contents v Software Configuration Guide—Catalyst 4000 Family, Catalyst 2948G, Catalyst 2980G, Releases 6.3 and 6.4 78-12647-02 Setting the Port Duplex Mode 4-5 Configuring a Timeout Period for Ports in errdisable State 4-6 Checking Connectivity 4-7 CHAPTER 5 Configuring Gigabit Ethernet Switching 5-1 Understanding How Gigabit Ethernet Works 5-1 Understanding How Gigabit Ethernet Flow Control Works 5-1 Flow-Control Overview 5-1 Sending and Receiving Pause Frames 5-2 Using Flow-Control Keywords 5-2 Understanding How Port Negotiation Works 5-3 Understanding How Oversubscrib

  • Cisco WS-C4003 - Catalyst 4000 Chassis Switch, 27-49 Software Configuration Guide—Catalyst 4000 Family, Catalyst 2948G, Catalyst 2980G, Releases 6.3 and 6.4 78-12647-02 Chapter 27 Configuring Switch Access Using AAA Understanding How Authorization Works Understanding How Authorization Works These sections describe how authorization works: • Authorization Overview, page 27-49 • Authorization Events, page 27-49 • TACACS+ Primary Options and Fallback Options, page 27-49 • TACACS+ Command Authorization, page 27-50 • RADIUS Authorization, page 27-50 Authorization Overview Your switch supports TACACS+ and RADIUS authorization to con

  • 15-7 Software Configuration Guide—Catalyst 4000 Family, Catalyst 2948G, Catalyst 2980G, Releases 6.3 and 6.4 78-12647-02 Chapter 15 Configuring Multicast Services Configuring CGMP Displaying Multicast Group Information To display information about multicast groups, perform one of these tasks in privileged mode: This example shows how to display information about all multic

  • Cisco WS-C4003 - Catalyst 4000 Chassis Switch, 11-17 Software Configuration Guide—Catalyst 4000 Family, Catalyst 2948G, Catalyst 2980G, Releases 6.3 and 6.4 78-12647-02 Chapter 11 Configuring VLAN Trunks on Fast Ethernet and Gigabit Ethernet Ports Example VLAN Trunk Configurations Figure 11-3 Parallel Trunk Configuration After Configuring VLAN Traffic Load-Sharing Figure 11-3 shows that both trunks are utilized when the network is operating normally and, if one trunk link fails, the other trunk link acts as an alternate forwarding path for the traffic previously traveling over the failed link. If Trunk 1 fails in the network shown in Figure 11-3, STP reconve

  • Cisco WS-C4003 - Catalyst 4000 Chassis Switch, Contents xv Software Configuration Guide—Catalyst 4000 Family, Catalyst 2948G, Catalyst 2980G, Releases 6.3 and 6.4 78-12647-02 Dispatcher 23-8 Message Processing Subsystem 23-8 Security Subsystem 23-9 Access Control Subsystem 23-9 Applications 23-9 Configuring SNMPv3 from an NMS 23-10 Configuring SNMPv3 from the CLI 23-10 Using CiscoWorks2000 23-13 CHAPTER 24 Configuring RMON 24-1 Understanding How RMON Works 24-1 Enabling RMON 24-2 Viewing RMON Data 24-2 Supported RMON and RMON2 MIB Objects 24-2 CHAPTER 25 Configuring SPAN and RSPAN 25-1 Understanding How SPAN and RSPAN Work 25-1 SPAN Session 25-1 Destination Port 25-2 Source Port 25-2 Reflector

  • Cisco WS-C4003 - Catalyst 4000 Chassis Switch, 2-9 Software Configuration Guide—Catalyst 4000 Family, Catalyst 2948G, Catalyst 2980G, Releases 6.3 and 6.4 78-12647-02 Chapter 2 Using the Command-Line Interface ROM Monitor Command-Line Interface ROM Monitor Command-Line Interface The ROM monitor is a ROM-based program that executes when the switch is powered on, reset, or when a fatal exception occurs. The system enters ROM monitor mode if the nonvolatile RAM (NVRAM) configuration is corrupted, if the switch does not find a valid system image or if the configuration register is set to enter ROM monitor mode. From the ROM monitor mode, you can load a s

  • Cisco WS-C4003 - Catalyst 4000 Chassis Switch, A-1 Software Configuration Guide—Catalyst 4000 Family, Catalyst 2948G, Catalyst 2980G, Releases 6.3 and 6.4 78-12647-02 APPENDIX A Acronyms This appendix defines the acronyms used in this publication. A AAL ATM adaptation layer ACE access control entry ADM add-drop multiplexer AFI Authority and Format Identifier AMP active monitor present APaRT automated packet recognition/translation ARP Address Resolution Protocol ASP ATM switch processor ATM Asynchronous Transfer Mode B BDPU Bridge Protocol Data Unit BRF Bridge Relay Function BUS broadcast and unknown server

Related Products and Documents (Switch):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Audio Technica unipoint U853AU Specifications audio-technica/unipoint-u853au-SL7.pdf 18 Jul 2023 1 0.44 Mb
2 Outdoor GreatRoom Company INSPIRATION-SS Owner's manual outdoor-greatroom-company/inspiration-ss-F8J.pdf 29 May 2023 16
3 Sony DAV-C900 - Compact Av System Operating instructions manual sony/dav-c900-compact-av-system-O7I.pdf 15 Jul 2022 84 0.85 Mb
4 HP Laserjet,Color Laserjet 4550 Getting started manual hp/laserjet-color-laserjet-4550-TG4.pdf 06 Nov 2023 2 0.9 Mb
5 Audiovox AXT-1200 Owner's manual audiovox/axt-1200-2NY.pdf 09 Sep 2023 14 0.59 Mb
6 Fender Jaco Pastorius Jazz Fretless Control function fender/jaco-pastorius-jazz-fretless-5WA.pdf 18 Mar 2023 1 0.05 Mb

Similar Resources:

  • D-Link

    DES-1005D

    (27 pages)
    Introduction This Quick Installation Guide gives step-by-step instructions for setting up the D-Link DES-1005D 10/100M Fast Ethernet Switch. The model you have purchased may appear slightly different from those shown in the illustrations. For more detailed information about the switch, its components, making network connections and technical s …
  • Grizzly

    G4572

    (2 pages)
    BLACKGREENREDCOLOR KEYBkGnRdYELLOW3L2 5L313NO2T14T26T314NOTESTTRIP IND.97 NO98 NO95 NC96 NC2T14T26T3OR54NONO53ONOFFRESET2 HP 220V Motor220 VoltSingle-PhasePower SourceMA1L1TECOCU-16Ground� …
  • AJA

    kumo 1604

    (8 pages)
    KUMOQuick Start GuideIntroductionThis Quick Start Guide provides a basic overview of KUMO system configuration.Figure 1. KUMO Devices1604 RouterTypical Router3232 Router6464 Router 1616 RouterRear PanelRear PanelRear PanelRear PanelKUMOControl PanelFront PanelVersion 4.0, November 18, 2016, Copyright © 2016 AJA Video Systems …
  • StarTech.com

    ST4200MINI

    (2 pages)
    4 Port Notebook Sized Mini USB 2.0 HubStarTech ID: ST4200MINITurn one USB 2.0 port into four with the StarTech.com ST4200MINI notebook-sized hub. Designed especiallyfor laptop users, this compact hub uses low levels of power so your notebook battery won’t bedrained. You’ll be able to maximize the performance of your USB 2.0 peripherals with up to 480Mbi …
  • Minuteman

    RPM 1600 Client

    (3 pages)
    MINUTEMAN® RPM™ – Remote Power ManagerThe MINUTEMAN RPM (Remote Power Manager) is theultimate power nerve center for controlling multiplenetwork devices and services. With the RPM, you canindividually control AC power for up to eight connecteddevices such as servers, hubs, routers, modems, andtelephone systems. Up to 15 client RPM units can beadded to c …
  • NETGEAR

    GS748T - ProSafe Smart Switch

    (2 pages)
    Start HereFollow these instructions to set up your smart switch.Prepare to Install Your Smart Switch• Prepare a PC with an Ethernet adapter and a CD ROM drive.• Before proceeding with the smart switch installation, familiarize yourself with the contents of the Resource CD, especially the manuals.First, Install the Smartwizard Discovery Utility on a PC1. …

Comments, Questions and Opinions: