  • Bacharach ADM800, Instruction 3015-4275 35 Audible Alarm This parameter selects the function of the ADM800’s internal audible alarm. 1. Press the AUDIBLE ALARM key to adjust the setting. 2. Use the UP/DOWN cursor keys to select unused, monitor on, evacuate, spill, leak, fault, or alarm. 3. Press ENTER to accept the new entry or QUIT to revert to the previous setting. Enabling Building Management System Connection This enables or disables the connection to a Building Management System. 1. Press the BMS key to adjust the setting. 2. Use the UP/DOWN cursor keys to toggle the setting. 3. Press ENTER to accept the new entry or QUIT to revert to the previous setting. Building

  • Bacharach ADM800, Instruction 3015-4275 i Table of Contents INTRODUCTION..............................................................................................................................................................II SAFETY PRECAUTIONS .................................................................................................................................................III WARNING STATEMENTS ........................................................................................ERROR! BOOKMARK NOT DEFINED. CAUTION STATEMENTS .........................................................................................ERROR! BOOKMARK NOT D

  • 22 Instruction 3015-4275 ADM800 - Interior Schematic Microcontroller Board CPU Reset Switch Main Board Ground Stud AC Power Front Panel Chassis Power Supply Board 120–230 VAC Input Microcontroller B oa r d CPU Reset S wi tc h Main Board AC IN Connector T3

  • Instruction 3015-4275 19 ADM800 Installation ADM800 Oblique Photo Upper & Lower Mounting Brackets Upper Mounting Bracket Lower Mounting Bracket

  • Bacharach ADM800, Instruction 3015-4275 1 AGM300 Installation Upper Mounting Bracket Lower Mounting Br ac k et Water Trap STANDARD ACCESSORIES FOR A 4 POINT SYSTEM 5 Line-End Filters (P/N 3015-3420) AGM300/ADM800 Instruction Manual (P/N 3015-4275) LED Indicators

  • Bacharach ADM800, Instruction 3015-4275 61 Service Mode When activated, the Service Mode will disable a specific AGM300 unit for a specified length of time. The default is 60 minutes. This time interval can be changed per Section Service Timeout on Page 40. IMPORTANT: Note that while in the Service Mode no measurements are made, nor are any alarms activated. From the System Screen (Page 31), select the key adjacent to the AGM unit you wish to place into its Service Mode. From AGM Setup Screen #1 (Page 37) press the SERVICE MODE ENTRY key twice within 3 seconds. Note that the System Screen will show what monitors are

  • Bacharach ADM800, 24 Instruction 3015-4275 ADM800 - Electrical Wiring It is highly recommended that the ADM800 be connected directly to the AC power source, preferably on its own circuit. The connection should be completed with a UL rated multi-conductor wire (14-18 AWG). Locate service knockouts on exterior of enclosure and install electrical conduit in the typical manner. The ADM800 is available in either a 120 or 230 VAC configuration. The unit’s AC voltage rating is marked on the outside of the enclosure. Do one of the following to connect the AC power leads and ground: • 120 VAC Installation Locate AC IN connector T3 and the Ground Stud on the inside of the enclosure (Page 22).

  • Bacharach ADM800, Instruction 3015-4275 53 Working with the Trend Screen Overview - Log Interval The AGM300 retains a data log of 100 measurements for each zone. The log interval is the number of minutes from 1 to 1440 between each log point. This parameter can be changed from the Zone Setup #1 Screen (Page 41). The default setting for this parameter is 1440 minutes (24 hours). If the log interval time is set to 0, then a measurement is recorded in the trend log after every measurement cycle. Therefore, after the trend log is filled it will contain the last 100 measurement points for a zone. If you want the data l

  • Bacharach ADM800, 4 Instruction 3015-4275 AGM300 - Connecting Air Lines Overview Individual sample lines are run from the AGM300 to each area of the facility to be monitored. Additionally, a purge line is installed to provide clean air for resetting the infrared zero baseline. An exhaust line is installed to vent residual gas away from the monitor. All sample line connections are made on the left side of the enclosure as indicated in the photograph below. AGM300 Side View Intake Ports Exhaust Port Purge Port RS-232 Connector Inlet / Purge Ports RS-232 I

  • Instruction 3015-4275 15 USB Type Laptops Some of the newer laptops have USB ports and no RS-232 9-pin ports. You will be required to purchase a PCMCIA card that provides an RS-232 output. We recommend the PCMCIA card manufactured by: SEALEVEL SYSTEMS, INC. 155 TECHNOLOGY PLACE P. O. BOX 830 LIBERTY, SC 29657 PHONE – 864-843-4343 www.sealevel.com

  • Bacharach ADM800, Headquarters: 621 Hunt Valley Circle, New Kensington, PA 15068 Ph: 724-334-5000 • Fax: 724-334-5001 • Toll Free: 1-800-736-4666 Website: www.bacharach-inc.com • E-mail: [email protected] Printed in U.S.A. ® Registered Trademark of Bacharach Inc.

  • Bacharach ADM800, 48 Instruction 3015-4275 Alarm Log From the System Screen press the key adjacent to the AGM300 unit that you wish to view. AGM Setup #1 Screen Press the ALARM EVENT LOG key to display Alarm Log Screen. Alarm Log Screen Use the LEFT/RIGHT and UP/DOWN cursor keys to move through the log. The Alarm log shows the last 20 alarm events. An alarm event is the occurrence of any alarm, any change in alarm level, or the clearing of any alarm. The alarm level is indicated by an L

  • Bacharach ADM800, 56 Instruction 3015-4275 Clearing System Faults If the fault condition is associated with an AGM300, the monitor will return to normal operation soon after the problem is corrected. At that time the YELLOW LED will turn off and any external alarms connected to the monitor’s alarm relays will also turn off. The ADM800 will return to normal operation the next time it polls the affected AGM300 monitor. Once the system malfunction has been corrected it may take some time for the fault condition to clear completely. If the fault is associated with a specific zone, th

  • Bacharach ADM800, 72 Instruction 3015-4275 Status Register Register 0x0011h R/W 10 bytes Variable Type Length Description Mode UC 1 byte Defines Operating Mode of AGM300. 0 = normal Mode; 1 = Zone_Hold Mode; 2 = Diagnostic Mode; 3 = Service mode. DO NOT MODIFY (use zone hold register or service mode register to change this parameter) State UC 1 byte Defines AGM300 Current State. 0 = Idle; 1 = Sampling; 2 = Zeroing; 3 = Warm Up, 4 = Pressure Check DO NOT MODIFY Measuring UC 1 byte Value = 1 if unit is acquiring detector signal for running avg. DO NOT MODIFY Active_Zone UC 1 byte Current Zon

  • Bacharach ADM800, Instruction 3015-4275 83 AGM300 - Specifications Product Type: Ammonia gas, multiple area infrared monitoring system for low level continuous monitoring of ammonia refrigerant gas used in most commercial refrigeration systems. System design supports compliance to the refrigerant monitoring requirements of ANS/BSR ASHRE 15-1994. Coverage: 4-point standard, expandable to 16 points in 4 point increments Detector Type: Infrared non-dispersive, computer enhanced Gas: Ammonia, NH 3 , R-717 Sensitivity: 1 ppm Measuring Ran

  • Bacharach ADM800, 46 Instruction 3015-4275 If the current Zone Screen appears normal, scroll through the displays using the NEXT/BACK keys or the UP/DOWN cursor keys until you locate the affected zone. You can further investigate the status of the affected zone by pressing the adjacent key and going to the Zone Setup #1 Screen (Page 41). You may also press the ALARM key to go directly to the Alarm Summary Screen (Page 50). See Working with Alarms on Page 50 to learn more about responding to alarms. Fault Conditions If a system malfunction occurs, the yellow FAULT LED will glow. Additionally, an external alarm device may activate and an audible alarm may sound if those features have been en

  • Bacharach ADM800, Instruction 3015-4275 11 Changing Terminator Settings The terminator switch is shipped from the factory in the terminated or “IN” position. This is the correct setting if the AGM300 is connected as a single device, or it is the last device on the network chain. If the AGM300 is being installed in the middle of a network, the terminator must be moved to the “OUT” position. Locate the switch and determine its position. If it needs to be moved, slide the switch to the appropriate position. Node Address DIP Switch Settings (Refer to Multiple AGM's and Connecting to a Building Management System) Each AG

  • Bacharach ADM800, 34 Instruction 3015-4275 Navigating to the 1 st ADM Setup Screen From the top level System Screen press the ADM SETUP key to go to ADM Setup Screen #1. ADM Setup Screen #1 Contrast This value sets the screen brightness. 1. Press the CONTRAST key to adjust its setting. 2. Use the UP/DOWN cursor keys to modify the setting. 3. Press ENTER to accept the new entry or QUIT to revert to the previous setting. Number of AGM Units This is the number of AGM300 monitors from 1–4 connected to the ADM800. 1. Press the #OF AGMS ON NET key to adjust the number. 2. Use the UP/DOWN cursor keys to modify the setting. 3. Press ENTER to accept the new entry or QUIT to

  • Bacharach ADM800, vi Instruction 3015-4275 AGM300 / ADM800 Refrigerant Gas Leak Monitor Mechanical Room Placement The ADM800 should be mounted outside of the mechanical room or at least just inside of a door to the room. This is the “split architecture design” for safety of the operator. The ADM800 can be located up to 4500 feet from the AGM300. The ADM800 is the main interface by which you program the AGM300, acknowledge alarms, and observe conditions inside of the mechanical room. Note that there are two additional alarm relay

  • Bacharach ADM800, Instruction 3015-4275 13 MULTIPLE AGM300’s CONNECTED TO A BUILDING MANAGEMENT SYSTEM DAISY CHAIN FASHION RS-485 TERMINATOR “IN” TERMINATOR TERMINATOR TERMINATOR TERMINATOR “OUT” “OUT” “OUT” “IN” AGM300 - PC Software Programming the AGM300 Using PC Software NOTE 1: There are two versions of PC software. Use Version 1.0 with AGM300 units with v1.0 Unit Firmware, which were built Ju

  • 2 Instruction 3015-4275 AGM300 - Installation Considerations Locating the Monitor The AGM300 should be centrally located in the facility and should be easily accessible for visual monitoring and servicing. Intake sample lines can be up to 500 feet in length, but it is important to remember that sampling cycle time is proportional to the total number and length of individual samp

More Instructions:

DOWNLOAD

Related Products and Documents (Security System):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Adamson IS7 Operation & user’s manual adamson/is7-884.pdf 12 May 2023 8
2 Rainforest Automation EAGLE Quick start manual rainforest-automation/eagle-B75.pdf 18 Apr 2023 2
3 Pitney Bowes DM125 Installing manual pitney-bowes/dm125-546.pdf 07 May 2023 25
4 Sony D-25 Operating instructions manual sony/d-25-1WJ.pdf 04 Mar 2023 12 0.66 Mb
5 Viking F20537B EN Use & care manual viking/f20537b-en-32B.pdf 29 Dec 2023 28 1.7 Mb
6 Denon DRW-585 Operating instructions manual denon/drw-585-9NK.pdf 04 Apr 2023 17 2.63 Mb

Similar Resources:

  • Gentex

    GN-503 SERIES

    (12 pages)
    PHOTOELECTRIC TYPESINGLE/MULTIPLE STATIONSMOKE ALARM, AC POWERED,WITH BATTERY BACK-UP &TANDEM WIRE CONNECTIONAND ELECTROCHEMICALCARBON MONOXIDE ALARMGN-503 SERIESCOMBINATIONPHOTOELECTRIC SMOKE& CARBON MONOXIDE (CO)ALARMLIMITED WARRANTYFor a period of 12 months from the date of purchase, or a maximum of 18 months from thedate of manufacture, Gentex wa …
  • Ksenia

    Lares

    (40 pages)
    GEBRUIKERSHANDLEIDING - USER GUIDE - MANUEL UTILISATEURCentrales - Integrated Panels - Centrale IntegréeKSI1000016.300 - KSI1100016.300 - KSI1000048.300 - KSI1100048.300 - KSI1100128.300www.kseniasecurity.com …
  • DUAL LITE

    LZ Series

    (2 pages)
    Final AssemblyEnergize unit. Charge a minimum of 24 hours prior to testing.4.Aim lamp heads towards center of unit and dress wires neatly to prevent pinching.1.➤2. Align housing slots over back plate tabs. Pivot housing and snap closed.3.Press test switch and hold. Aim lamp heads for proper light distribution.5.TROUBLE SHOOTINGAC-On Light does not illu …
  • Helmer

    i.C3

    (46 pages)
    i.C³® User GuideFor Helmer i.Series® Products360405/ALabratory RefrigeratoriLR105-GX, iLR113-GXBlood Bank RefrigeratoriBR105-GX, iBR113-GX Pharmacy RefrigeratoriPR105-GX, iPR113-GX …
  • Fire Burglary

    XL-31 Series

    (48 pages)
    XL-31Hookup and Installation Instructions(Includes XL-31 and XL-31B)FIRE BURGLARY INSTRUMENTS, INC.A Subsidary of HtWay Corp.N9340 11/93 @993, FBX149 Hleen Way, Syosset, NY 11791(800) 645-5430* (51 6) 921-8666 …
  • Gewiss

    Chorus

    (160 pages)
    Cronotermostato da pareteprogramma giornaliero settimanaleWall time-thermostat daily-weekly programmeChronothermostat mural programme journalier-hebdomadaireCronotermostato de pared programa diario-semanalWandzeitthermostat Täglich-wöchentliches ProgrammCronotermostat de perete cu program zilnic sau săptămânalGW 10 701 GW 14 701CHORUS …

Comments, Questions and Opinions: