  • Bay Technical Associates BayTech DS62, DS62-Network, DS62-MD4 Network/Modem Host Module 17 Serial Port Configuration Handshaking, Baud Rate, Word Size, Stop Bits, and Parity are configured through either the serial or Ethernet ports using the menus. RTS and DTR Line Drivers can only be configured through the phone line via a modem. The default settings are 9600bps, 8 data bits, no parity, one stop bit, RTS and DTR High. IMPORTANT: Changing the Host module serial port configuration could create a communications lock-out if the terminal computer serial port configuration does not match the host module. Handshaking For a simple communication betwee

  • DS62-Network, DS62-MD4 Network/Modem Host Module 38 Select 1), List Outlet Groups to list any outlet groups, the DS display: Select 2), Add Group to add a specific outlet group, the DS display: The DS displays the following and asks for a name for the new Group: Select 3), Delete Group to delete a specific outlet group, the DS displays the follo

  • Bay Technical Associates BayTech DS62, DS62-Network, DS62-MD4 Network/Modem Host Module 15 Unit Configuration Menu The configuration menu allows the admin user to establish the parameters the DS-Series will operate. Select the number of the host module and the following menu is displayed: Configuration Status The Status menu displays the modules installed and the current configuration of the host module. The following are the factory default settings: Accept changes ? (Y/N) :y Changes accepted. Configuration DS62 module #1..........1 DS74 module #2......

  • Bay Technical Associates BayTech DS62, DS62-Network, DS62-MD4 Network/Modem Host Module 51 BayTech Product Warranty Bay Technical Associates (BayTech) warrants that its products will be free from defects in materials and workmanship under normal use for a period of two years from date of purchase (or from date of shipment from BayTech if proof of purchase is not provided). During this warranty period, BayTech shall, at its discretion, either repair or exchange any defective product at no charge for labor and materials, or refund the amount p

  • Bay Technical Associates BayTech DS62, DS62-Network, DS62-MD4 Network/Modem Host Module 34 If you have SNMPv3 software, only the newer firmware will have this option. Selecting this option the DS displays, Default is Disabled. Select this option to enable a SNMP trap to be sent if an authentication attempt failed, the DS displays, Default is Disabled. Web Server Configuration Selecting the Web Server Configuration option and the DS displays the following: NOTE: For this feature to operate the network port must have an IP Address assigned. Depending on the firmware in your DS unit, the new

  • Bay Technical Associates BayTech DS62, DS62-Network, DS62-MD4 Network/Modem Host Module 39 Note: There will be no confirmation the groups have been deleted. Select option 1 from the Outlet Group Configuration to verify all outlet groups were deleted. Firmware / Config Download This option allows the admin to flash upgrade the firmware to the Host module through an FTP client. The admin can upload the configuration file, make changes, and download back to the unit. This feature ensures multiple units will have the same configuration without having to manually configure each unit separately. NOTE: Contact Baytech Support for the instruction sheet and firmware upgrade file

  • Bay Technical Associates BayTech DS62, DS62-Network, DS62-MD4 Network/Modem Host Module 52 Technical Support BayTech offers Tech Support for the lifetime of the product. A staff of Applications Engineers is on duty to assist with installation, set up or operation issues. Support is available from 8:00 a.m. to 5 p.m. (CST or CDT), Monday through Friday at the phone numbers or website provided below. Please have the following information available to help the Applications Engineers answer questions efficiently: 1. BayTech model type 2

  • Bay Technical Associates BayTech DS62, DS62-Network, DS62-MD4 Network/Modem Host Module 6 Connection Description BayTech's host communication module provides an interface that controls user access to the DS Series data switch and other DS Series connected modules. EIA-232 SERIAL CONNECTION The DS-Series host communications modules have an RJ-45 port which uses an 8-pin crossed modular cable to connect to a local EIA-232 device such as a computer terminal or external modem. Most serial computers do not have RJ-45 connections; therefore an adapter is provided with this unit to convert from a DE-9 connector to an RJ-45 connector (Bay Tech Part No. 9FRJ45PC-4). An adapter to convert f

  • DS62-Network, DS62-MD4 Network/Modem Host Module 5 ABOUT THIS OWNER’S MANUAL This document is applicable to the DS62 Network Module and the DS62-MD4 Network/Modem Module EXCEPT those paragraphs specifically mentioning the DS62-MD4 do not apply to the DS62. This document provides information required for installing and operating your Bay Tech equipme

  • Bay Technical Associates BayTech DS62, DS62-Network, DS62-MD4 Network/Modem Host Module 23 Select the Change Password option to change the user password, the Host Module displays the following: Select “Change Port Access Rights” to change the user’s assigned ports. If you select the “root user” the Host Module will display the following: Select a non-root user and the DS displays: Type ‘all’ and press <cr>, the DS displays all ports available to ‘user1’: Type ‘none’ and press <cr>, the DS displays the user with no assigned ports: To add specific ports to the user, enter the modul

  • Bay Technical Associates BayTech DS62, DS62-Network, DS62-MD4 Network/Modem Host Module 32 Select D), Delete Rule to delete a specific rule. The DS displays: SNMP Configuration Selecting the SNMP Configuration and the Host Module respond: Depending on the firmware, SNMP Configuration allows the admin to control whether or not a user has Read/Write access or Read access only. It also allows the admin to control which IP addresses are allowed to receive a host trap, and simply whether to enable or disable the entire

  • Bay Technical Associates BayTech DS62, DS62-Network, DS62-MD4 Network/Modem Host Module 10 Attention Character If no Baytech power strips are to be controlled through this Data Server, skip this step. Pressing the Attention Character 5 consecutive times will access the network main menu. The Default is a semi- colon (;). Select this option to change the attention character. The DS displays the following: Attention Character is........... ; Enter Attention Character : Login Setup Menu Figure 3 Access Control This security feature allows the admin to enable or disable usernames and passwords for both network and serial port

  • Bay Technical Associates BayTech DS62, DS62-Network, DS62-MD4 Network/Modem Host Module 11 Radius Configuration Radius is used to authenticate logins for the serial and the network ports if passwords and user names are enabled on the DS. If the Radius server rejects either the username or password or does not respond, the DS will display “Invalid Password”. TACACS Configuration TACACS can be used to authenticate logins for the serial port, the network port, and modem. When a telnet / SSH session (or rs232 session) is started the Host module will prompt for the username and password. The

  • DS62-Network, DS62-MD4 Network/Modem Host Module 24 Enter an incorrect port the DS displays: Delete User Select D), press <cr>, and type the number of the user to be deleted: NOTE: the ‘root’ user can not be deleted. Direct Port Connection This will allow the user to be connected directly to a DS serial port, as determined by the TCP port, starting at TCP port 50

  • Bay Technical Associates BayTech DS62, DS62-Network, DS62-MD4 Network/Modem Host Module 27 Select “TACACS Encryption Enable” to turn TACACS+ encryption off or on. Sending unencrypted TACACS packets is useful for troubleshooting but should not be used under normal operations. Select “TACACS Server Port to assign a more secure port, default is TCP 49. If you type a port number less than 1024 the Host Module responds with the following until a valid entry is typed: Network Port Configuration This menu is used to change the network configuration options such as the IP Address, Subnet Mask, Gateway, DHCP, and Telnet; all of which are necessary during initial startup.

  • Bay Technical Associates BayTech DS62, DS62-Network, DS62-MD4 Network/Modem Host Module 46 Logged Users This option shows the number of active sessions. For each session, the name of the user account, the type of interface (serial or network) and the status is provided. Terminate a session by typing “T” at the prompt. The Host Module responds: Memory Usage Current Routing Cache IP Data currently held in cache or none upon power cycle. eth0 Link encap:Ethernet HWaddr 00:C0:48:00:01:FD inet addr:192.168.2.136 Bcast:192.168.2.255 Mask:255.255.255.0 UP BROADCAST RUNNING MULTICAST MTU:1500 Metric:1 RX packets:0 errors:0 dropped:0 overruns:0 fr

  • Bay Technical Associates BayTech DS62, DS62-Network, DS62-MD4 Network/Modem Host Module 12 Cabling RJ-45 Cables and Adapters DS62 EIA-232 RJ-45 Signal Pin EIA 232 Signal Signal Direction Description 1 DTR Out Handshake, Line Driver Inactive State = High: +12V when power is applied. Used as a handshake line to enable/disable the receiving of characters. 2 GND Signal Ground 3 RTS Out Handshake, Line Driver Inactive State = High: +12 V when power is applied. Not used to enable/disable. 4 TX Out Transmit Data Out 5 RX In Receive Data In 6 DSR In Handshake In. –12V when not used. 7 GND Signal Ground 8 CTS In Used as a

  • Bay Technical Associates BayTech DS62, DS62-Network, DS62-MD4 Network/Modem Host Module 3 ABOUT THIS OWNER’S MANUAL ........................................................................................................5 Connection Description.......................................................................................................................6 EIA-232 SERIAL CONNECTION.....................................................................................................6 Internal MODEM CONNECTION............................................

  • Bay Technical Associates BayTech DS62, DS62-Network, DS62-MD4 Network/Modem Host Module 29 Select 2) to enter the Subnet Mask followed by <cr>. Failure to enter the address in the decimal form causes the DS to display the following until it is entered correctly. Default Subnet Mask is 0.0.0.0. Gateway Address The Gateway is the address of a router to connect to other parts of a network. The Gateway address consists of four bytes, each byte ranging from 0 to 255. If your network uses gateways, this parameter must be programmed before the DS can be accessed through the network. Select 3) to enter the Gateway address. Failure to enter the address i

  • Bay Technical Associates BayTech DS62, DS62-Network, DS62-MD4 Network/Modem Host Module 18 via binary, it is very likely that these values could be transmitted as data and the transmission would fail. 2. Hardware Handshaking: This style uses actual hardware lines. Like the TX and Rx lines, the RTS/CTS and DTR/DSR lines work together. When a receiver is ready for data, it will assert the RTS (Request to Send) line. This is then read by the sender at the CTS (Clear to Send) input, indicating it is clear to send the data. DTR (Data Termin

  • Bay Technical Associates BayTech DS62, DS62-Network, DS62-MD4 Network/Modem Host Module 22 ADD User Select A), and press <cr> to add a user and their password. The DS displays the following: NOTE: Log Out will be the only option available to the user if port access is not assigned. NOTE: If you forget your password, the administrator has to delete the user then add them back in. IMPORTANT: You can change the admin password. If you forget, resetting the unit back to factory default is the only way to get the admin password back. Change User’s Port Acces

  • DS62-Network, DS62-MD4 Network/Modem Host Module 33 The SNMP Trap Host is a trap management station that receives and processes traps. Traps are system alerts that the Baytech device generates when certain events occur. By default, no trap manager is defined, and no traps are issued. Up to four SNMP Trap Hosts maybe assigned to receive traps. Select a “SNMP Trap Host”, the DS wi

  • DS62-Network, DS62-MD4 Network/Modem Host Module 9 Figure 1 Select option ‘C’ for the configuration menu. Select the DS62 module option and the following menu is displayed: Figure 2 DS-Series - F 2.10.05 (C) 2005 Bay Technical Associates Module Name: DS62 Module: 1 Attention Character: ; Device A (2, 1).........1 Device B

  • DS62-Network, DS62-MD4 Network/Modem Host Module 48 Enter a PID number and press ‘Enter’ to terminate the process. IMPORTANT: If a process is terminated, the functionality of the unit maybe interrupted. To reestablish the unit’s functionality, power the unit off than back on. UnitInfo Database Unit Reset NOTE: Resetting the unit do

  • Bay Technical Associates BayTech DS62, DS62-Network, DS62-MD4 Network/Modem Host Module 47 Route Setup Every TCP/IP client machine, regardless of operating system, needs to make decisions about where to send a packet after it has been addressed. The route table is the network map that tells your Baytech product how to deliver the packet to its network addressee. • Destination, is a list of routes. “0” represents any number. • Gateway, is the network gateway for the route. The connection point to your company network. • Genmask, It defines how

  • Bay Technical Associates BayTech DS62, DS62-Network, DS62-MD4 Network/Modem Host Module 49 Troubleshooting: Functional Solutions: 1. No menu serial port: a. DS power is on and cable connected to EIA232 serial port. b. Verify the cable and adapter has the correct pin out, RJ08X007 and 9FRJ45PC-1. c. Cisco Rollover cables have the same pin out as RJ08X007. d. Type 5(;), the Attention Character will not echo to the screen, if it does than it may have been changed to a character other than the semi-colon. 2. No Menu Ethernet Port: a. Note w

  • Bay Technical Associates BayTech DS62, DS62-Network, DS62-MD4 Network/Modem Host Module 30 DHCP/Telnet/SSH Dynamic Host Configuration Protocol (DHCP) is a communications protocol that lets network administrators manage centrally and automate the assignment of Internet Protocol (IP) addresses in an organization's network. Default setting is DISABLED. Telnet is a user command and an underlying TCP/IP protocol for accessing remote devices. On the Web, HTTP and FTP protocols allow you to request specific files from remote computers, but not to actually be logged on as a user of that computer. Default setting is ENABLED. IMPORTANT: Changing this setting will logout all SS

  • Bay Technical Associates BayTech DS62, DS62-Network, DS62-MD4 Network/Modem Host Module 44 Select “Parity” the DS displays the following: Default is None. Rings to Auto Answer Select “Rings to Auto Answer” to set the number of rings before the unit answers. The module displays the following: The default setting is 2. Modem Connectivity Timeout Select the Modem Connectivity Timeout option to set the continuous connectivity time (1 to 120 minutes) before the modem automatically disconnects. Entering a time of 0 disables the Connectivity Timeout.

Related Products and Documents (Network Card):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Wilson Electronics AG Pro Quint Selectable Installation manual wilson-electronics/ag-pro-quint-selectable-VA6.pdf 22 Nov 2022 16
2 Baxi Main System Eco Elite Range User's manual and important warranty information baxi/main-system-eco-elite-range-932.pdf 18 Mar 2023 12
3 Sony CDX-F5000C Service manual sony/cdx-f5000c-619.pdf 28 Jun 2023 46
4 VTech CS6120-2 Quick start manual vtech/cs6120-2-HP1.pdf 21 Jul 2023 2 1.46 Mb
5 Logitek Pilot Manual  logitek-electronics/pilot-OAG.pdf 25 Feb 2024 33
6 Fujitsu FTP-627MCL354 Specifications fujitsu/ftp-627mcl354-74C.pdf 14 Apr 2024 6 0.19 Mb

Similar Resources:

  • Cisco

    ASR 9000 Series

    (204 pages)
    Americas HeadquartersCisco Systems, Inc.170 West Tasman DriveSan Jose, CA 95134-1706 USAhttp://www.cisco.comTel: 408 526-4000800 553-NETS (6387)Fax: 408 527-0883Cisco ASR 9000 Series Aggregation Services Router Modular Quality of Service Configuration GuideCisco IOS XR Software Release 4.0.0 December, 2010Text Part Number: OL-23108-02 …
  • Lucent Technologies

    Brick Series

    (52 pages)
    Lucent Security Management ServerBrick® Hardware GuideRelease 8.0260-100-002R8.0C109542290Version 8.0-1January 2005Lucent Technologies - ProprietaryThis document contains proprietary information of Lucent Technologies and is not to be disclosed or used except in Accordance with applicable agreementsCopyright © 2005 Lucent TechnologiesUnpublished and Not fo …
  • Quantum

    Tape Drives A-Series

    (105 pages)
    81-81487-04 A01A-Series Tape DrivesA-Series Tape Drives5SERS'UIDE5SERS'UIDE5SERS'UIDE5SERS'UIDE5SERS'UIDE5SERS'UIDE5SERS'UIDE …
  • Samsung

    SADT-100HM

    (1 pages)
    56 / 57SAMSUNG VIDEO SECURITY SYSTEM I CAMERAS|Dimensions (unit:mm)SBR-100DCMCeiling-Mount Bracket|Specifications• Solid structure• Metallic material|Features* Conditions for Installation : The installation place should be able to bear up to 4 times the total product weight (about 16Kg).This product is to be used when the thickness of the ceiling board …
  • Viking

    FXI-1

    (8 pages)
    Viking’s FXI-1 universal paging interface allows you to provide pagingfrom virtually any type of phone system instead of from a microphone.You can also provide background music and electronic night bell overthe audio system.The FXI-1 provides 26V talk battery for interfacing with an FXO orunused analog line input/trunk port. With the flip of a switch, the …
  • D-Link

    DWA-643

    (32 pages)
    1WIRELESS N EXPRESSCARD NOTEBOOK ADAPTERDWA-643Quick Install Guide+Installations-Anleitung+Guide d’installation+Guía de instalación+Guida di Installazione+Installatiehandleiding+Instrukcja instalacji+Instalační příručka+Telepítési Segédlet+Installasjonsveiledning+Installationsvejledning+Asennusopas+Installationsguide+Guia de Instalação+Οδηγ …

Comments, Questions and Opinions: