Manualios.com

BellSouth E911 Owner's Manual

BellSouth E911 Manual Online:

4.05, 880 votes
BellSouth E911 User Manual
BellSouth E911 User Guide
BellSouth E911 Online Manual

Text of BellSouth E911 User Guide:

  • BellSouth E911, CG-EWCG-001 Wireless E911 Guide Issue 3, January 6, 2004 TN Errors and Corrective Action Table H Error Codes and Corrective Action (continued) Error Code Error Message Occurs when. . . Corrective Action for . . . 107 House number contains invalid characters The house number on the incoming SOIR contains characters other than alpha or numeric. Determine the correct MSAG valid house number and submit corrective SOIR for errored TN 108 House number is too long The house number on the incoming SOIR contains too many characters Determine the correct MSAG valid house numbe

  • BellSouth E911, Wireless E911 Guide CG-EWCG-001 TN Database Updates Issue 3, January 6, 2004 Table C Instructions for NXX Table Update Form (continued) Instructions for NXX Table Update Form NPA / NXX(s): List all NPA/NXXs for pANI records in this service area. E911 TANDEM CLLI: Enter the CLLI code for the E911 tandem for which 911 calls using a pANI with This NXX will be routed to. (The BST Wireless E911 Implementation Manager can assist you in determining this value). The NPA/NXXs for the pANI records must be valid in this E911selec

  • BellSouth E911, CG-EWCG-001 Wireless E911 Guide Issue 3, January 6, 2004 Coordination of Wireless Interconnection 2. Coordination of Wireless Interconnection 2.1 Overview This section provides the Wireless Carrier with the steps necessary to interconnect with the BellSouth (BST) E911 network. The FCC Wireless Phase 1 Order requires the Wireless Carrier to provide both the cell site sector location information and the wireless subscribers call - back number for wireless 911 calls. Phase 2 requires the additional data fields longitude and latitude

  • BellSouth E911, CG-EWCG-001 Wireless E911 Guide Issue 3, January 6, 2004 Network Specifications and Ordering 3. Network Specifications and Ordering 3.1 Overview This section provides the Wireless Carrier with the Network Specifications and Ordering Procedures to be followed when ordering facilities to interconnect to the BST E911 network. Due to the complex nature and many processes involved with interconnecting to the BST E911 network, coordination between the Wireless Carrier and the various BST organizations involved will be accomplished through the Wireless Carrier’s Mark

  • BellSouth E911, Wireless E911 Guide CG-EWCG-001 BellSouth Wireless E9–1–1/SS7 Interconnection Guide Issue 3, January 6, 2004 NENA (National Emergency Number Association) has published a Technical Information Document: "NENA 05-501 Technical Information Document on SS7 Guidelines for MSC to Selective Router Connectivity." (available at: h ttp://www.nena9-1-1.org/9-1-1TechStandards/tech_info_docs.htm ). That document identifies many of the possible call setup parameter options that can occur within the enhanced 9-1-1 network on a

  • Wireless E911 Guide CG-EWCG-001 Coordination of Wireless Interconnection Issue 3, January 6, 2004 2.5.2 Initial Establishment of Mobile Position Center Provider The first step for the Wireless Carrier in establishing their MPC provider is to contact the BST Wireless E911 Implementation Manager. At that time a discussion will take place to determine the method of connectivity. The Wireless Carrier

  • BellSouth E911, CG-EWCG-001 Wireless E911 Guide Issue 3, January 6, 2004 TN Errors and Corrective Action Table F Confirmation Report Fields and Descriptions (continued) COMMUNITY NAME Valid service community of the street name/house number as designated by the MSAG. STATE Alpha state abbreviation LOCATION Additional address information (free formatted) describing the exact location of the Calling Number (e.g. APT 718). CUSTOMER NAME Subscriber name associated with the Calling Number. CLASS OF SERVICE Value of: • 8=Moble (pre-Phase 1) • G=Wirel

  • BellSouth E911, Wireless E911 Guide CG-EWCG-001 TN Database Updates Issue 3, January 6, 2004 STEP ACTION 11 Three(3) weeks prior to testing or implementing a new NXX, the Wireless Carrier must furnish the NXX Table update form to the BST Wireless E911 Implementation Manager. The form and instructions for its completion are contained in this tab. 12 Work with E911 Customer to resolve address or ESN discrepancies. 13 Transfer data files to INTRADO to test database processing at least one week prior to service implementation. 14 Identify and resolve special requirements for premises

  • BellSouth E911, CG-EWCG-001 Wireless E911 Guide Issue 3, January 6, 2004 BellSouth Wireless E9–1–1/SS7 Interconnection Guide The WSP (or their agent) must have the ALI database pre-populated with records matching the pANIs (ESRD/ESRK) they will use, or the call will default route, and the PSAP will receive a "no record found" rather than the expected location information. A.6 Wireless CCS Network Interconnection Architecture A.6.1 General Interconnection Information Signaling System 7 - Common Channel Signaling using ISDN User Part protocol (SS7/ISUP) for Wireless E9-1-1 is only supported for Type 2C trunks (interc

  • CG-EWCG-001 Wireless E911 Guide Issue 3, January 6, 2004 TN Errors and Corrective Action 6. TN Errors and Corrective Action 6.1 Overview This section provides procedures for correcting errors that are generated when updates to the E911 database do not pass database edits. Records that fail the edits will be sent daily in an error report to the Wireless Carrier. Errors are sorted in TN order

  • CG-EWCG-001 Wireless E911 Guide Issue 3, January 6, 2004 BellSouth Wireless E9–1–1/SS7 Interconnection Guide not modify it, it simply passes whatever value it receives. Once again, the NDET sets this value, but as of NA013 does not use it to identify wireless calls. In NA016, the NDET began checking the OLI parameter on wireless E9-1-1 calls ONLY when usi

  • BellSouth E911, Wireless E911 Guide CG-EWCG-001 BellSouth Wireless E9–1–1/SS7 Interconnection Guide Issue 3, January 6, 2004 A.7.2 Calling Party Number Parameter Calling Party Number is a required parameter in the IAM. The Called Party Number parameter value is variable depending upon which trunk group signaling option is being used. In any case it shall either contain the digits "911" or a pANI. The Called Party Number parameter includes the digits "911" when the pANI is provided in the Generic Digits Parameter (WRLS_STD signaling option), or when the Calling Party Number contains the pANI (E911_STD for Wireline Compatibility Mode). The Called Party

  • Wireless E911 Guide CG-EWCG-001 TN Errors and Corrective Action Issue 3, January 6, 2004 to Intrado Connect, (2) click on the transfer key, and (3) click on the download key and automatically retrieve your reports. 6.2.4 TN Error Deletion When a SOIR is processed, a check is made to determine if an error record exists in the error file with the same TN on the SOIR. If an error record other than

  • BellSouth E911, CG-EWCG-001 Wireless E911 Guide Issue 3, January 6, 2004 Coordination of Wireless Interconnection • If the Wireless Carrier is connecting to a DMS100 E911 tandem utilizing an existing Nortel wireless connection to the ALI computers, no additional data circuits will be required for Phase 1. • If the Wireless Carrier provides their own wireless solution hardware in their network, the Wireless Carrier must provide the data circuits. • If the Wireless Carrier contracts with a third party to provide the connection to the ALI computers, the data

  • BellSouth E911, Wireless E911 Guide CG-EWCG-001 Network Specifications and Ordering Issue 3, January 6, 2004 3.2.2 Specification & Ordering Process: Option 2: Third Party Vendor Solution The Wireless Carrier will be required to order a minimum of two (2), Type 2C, CAMA or SS7/ISUP signaling trunks, connecting to the appropriate BellSouth E911 Tandem switch. If SS7 connectivity will be used, refer to Appendix A of this guide. If using CAMA signaling, the Wireless Carrier must be able to deliver to the BellSouth E911 Tandem the two(2) stage CAMA MF signal required for interfacing directly with the appropriate BellSouth E911 Tandem switches. This signal is in the following format: Stage 1: KP + 11 + ST S

  • BellSouth E911, Wireless E911 Guide CG-EWCG-001 TN Errors and Corrective Action Issue 3, January 6, 2004 Table F Confirmation Report Fields and Descriptions (continued) GENERAL USE Mutually used by data exchange partners to pass information not defined in previous fields. CUSTOMER CODE Code used to uniquely identify customer. COMMENTS Optional notes may be displayed at PSAP X COORDINATE Longitude / X coordinate Y COORDINATE Latitude / Y coordinate Z COORDINATE Structure elevation CELL ID Identification number indicating a geographic region of cellular coverage. SECTOR ID Sub set / section of a cell. TAR CODE Taxing

  • Wireless E911 Guide CG-EWCG-001 TN Database Updates Issue 3, January 6, 2004 5.12 SOIR File Header Record Layout 5.12.1 Table: SOIR File Header Record - BellSouth 512 Character Format for Data Exchange Field Name Position Bytes Type BellSouth Description HEADER INDICATOR 1-5 5 A Always "UHL " EXTRACT DATE 6-11 6 N Date formatted as MMDDYY COMPANY NAME 12-61 50 AN CYC

  • BellSouth E911, Wireless E911 Guide CG-EWCG-001 BellSouth Wireless E9–1–1/SS7 Interconnection Guide Issue 3, January 6, 2004 A.8 Cross Reference Tables to J-STD-036-A The intention of this section is to provide a method for a WSP to assess which type of BellSouth supported SS7/ISUP signaling option can best fit their needs. Each decision MUST take into account the capability of the WSPs MSC and the capability of the PSAP CPE, and may be impacted by the type of ALI steering options involved. The following pages in this section represent

  • BellSouth E911, Wireless E911 Guide CG-EWCG-001 TN Database Updates Issue 3, January 6, 2004 Table D BellSouth Street Suffix (Thoroughfare) Abbreviations (Table) (continued) T / F Abbrev Description T / F Abbrev Description FRK FORK RUN RUN FRWY FREEWAY SQ SQUARE GRDN GARDEN ST STREET HBR HARBOR STA STATION HL HILL TER TERRACE HLS HILLS THRWY THRUWAY HOLW HOLLOW TR TRAIL HT HEIGHT TRC TRACE HTS HEIGHTS TRNPK TURNPIKE HWY HIGHWAY VLG VILLAGE ISL ISLAND WAY WAY JCTN JUNCTION WHF WHARK LDG LANDING WK WALK LK LAKE YD YARD When "Avenue" precedes a street name that is a letter or number, it is not considered a street suff

  • BellSouth E911, CG-EWCG-001 Wireless E911 Guide Issue 3, January 6, 2004 BellSouth Wireless E9–1–1/SS7 Interconnection Guide A.7.4 Charge Number Parameter If present, the Charge Number parameter shall contain the caller’s CBN or the non-dialable callback number, or in Wireline Compatibility Mode it shall contain the pANI. Charge Number is an optional parameter in the IAM. Charge Number is an optional parameter in the IAM. NOTE: Charge Number Parameter is ignored by the NDET when using either of the WRLS_ xxx signaling options.) A.7.5 Calling Party Category Parameter (CPC, aka: CPCat) The Calling Party C

  • BellSouth E911, CG-EWCG-001 Wireless E911 Guide Issue 3, January 6, 2004 Overview of E911 1.7 Glossary of Terms Table B Glossary of Terms Term Definition ACAC Access Carrier Advocacy Center Address Verification Request (AVR) A form issued by each telco to refer and resolve address discrepancies with the E911 Customer. ALEC Alternative Local Exchange Carrier Alternate Routing A standard feature provided to allow E911 calls to be routed to a designated alternate location if : 1. all E911 trunks to the primary PSAP are busy OR 2. the primary PSAP closes down for a period. (i.e. night service) Automatic Location Identification (ALI) A feature by which the address associated with the telephone num

  • BellSouth E911, Wireless E911 Guide CG-EWCG-001 Coordination of Wireless Interconnection Issue 3, January 6, 2004 of the appropriate E911 tandem, 911 call routing, default routing for ANI failures, and assignment of geographically valid pANI numbers from the wireless carrier’s number range. The E911 customers must agree on which PSAP will accept 911 calls from the various cell sites including when ANI failures occur. Wireless Carriers should also determine if the E911 Customers wish to segregate wireless 911 calls from wireline 911 calls by implementing separate trunk groups to the PSAP. All premises based E911 databases should be identified as well as any special procedures nec

  • BellSouth E911, CG-EWCG-001 Wireless E911 Guide Issue 3, January 6, 2004 TN Database Updates STEP ACTION 5 Coordinate MSAG updates for the cell sites (or PSAPs) submitted on Maintenance Ledgers by the E911 Customer (including naming/numbering street data) 6 Update address on pseudo-ANI (TN) records as address data or cell site coverage area is modified. 7 Any new service and all subsequent activity affecting the cell site location or PSAP records must be updated into the TN database. Each record affected must be sent individually with the appropriate changes. For example, if the address changes for a cell site which has 3 pseudo-ANI telephone numbers, all three(3) individual

  • BellSouth E911, Wireless E911 Guide CG-EWCG-001 TN Database Updates Issue 3, January 6, 2004 5.10 Service Order Interface File Specifications This section describes BellSouth Service Order Interface file specifications and Service Order Interface Record (SOIR) layouts. BellSouth SOIR layouts resemble the 512 character NENA Version 2 layouts for Data Exchange with some BellSouth specific differences. Files for updating the BellSouth E911 database must adhere to the following file specifications: 1. All files contain a single file header record, followed by one or more data records, followed by a single file trailer record. All records are 512 charact

Related Products and Documents (Wireless Router):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Snapper LT1644 Parts manual snapper/lt1644-R42.pdf 04 Aug 2022 52 1.19 Mb
2 Haier HWM65-0528 Operation & user’s manual haier/hwm65-0528-1R5.pdf 28 Sep 2023 10 1.02 Mb
3 Yamaha Electone B-55N Operation & user’s manual yamaha/electone-b-55n-D92.pdf 18 Sep 2023 18 4.7 Mb
4 Renesas M3T-FLX-64NSA Operation & user’s manual renesas/m3t-flx-64nsa-478.pdf 30 Jan 2024 4 0.2 Mb
5 Brother BE-0901EAC Upgrade manual brother/be-0901eac-BU5.pdf 10 Mar 2024 3 0.12 Mb
6 Panasonic EY6808 Service manual panasonic/ey6808-665.pdf 06 Jan 2023 7 0.19 Mb

Similar Resources:

  • TP-Link

    Archer C50

    (2 pages)
    Quick Installation GuideAC1200 Wireless Dual Band Router If your Internet connection is through an Ethernet cable from the wall instead of through a DSL / Cable / Satellite modem, connect the Ethernet cable directly to the router’s Internet port, then follow steps 4 and 5 to complete the hardware connection.7106505693 REV2.0.0Verify that the hardware con …
  • TRENDnet

    TEW-OA14D

    (2 pages)
    TRENDnet's TEW-OA14D Outdoor Directional Antenna provides long distance point-to-point connection for your wireless network. As an optional antenna for your IEEE 802.11b 2.4GHz 11Mbps wireless network equipments, you can install it outdoor for connecting network up to 8 Km away, or install it in the building to blast through o …
  • Cradlepoint

    COR IBR1100LPE

    (4 pages)
    ©Cradlepoint. All Rights Reserved. | +1.855.813.3385 | cradlepoint.com1Quick Start Guide / COR IBR1100 Series + Cloud-managed + Dual-band, dual-concurrent WiFi + Ruggedized + Ignition sensing + 9-36 DC voltage input range + Active GPS Support + Software-defined radio + Integrated 3G/4G/LTE modemCOR IBR1100 Key Features:COR IBR1100 SeriesMission-Cr …
  • Dell

    2300

    (178 pages)
    Dell™TrueMobile™2300 Wireless Broadband RouterUser's Guide Contents Introduction Managing Your Router Configuration Steps for Common Scenarios Technical Specifications and Regulatory Information FAQs Glossary Online Customer Support Information in this document is subject to change without notice.© 2003 Dell Computer Corporation. All rights reserv …
  • Tenda

    W150M

    (5 pages)
    Review and Guide to setup the New Tenda W150M WiFi 150MBPS WifibridgeI've been testing the Tenda W150M AP/Router/Wirelessbridge for the last month or so to test its stability and reliability as found the Vonets Tenda W150M works as good as any 85MBPS Homeplugs! Its works absolutely superb and is a doddle to setup! The Tenda W150M can be purchased from …
  • D-Link

    DIR-412

    (34 pages)
    MOBILE WIRELESS ROUTERDIR-412QUICK INSTALLATION GUIDE快速安裝指南� …

Comments, Questions and Opinions: