  • Broan-NuTone AE60, 7 3. INSTALL THE UNIT Choose an appropriate location for the unit, far from the areas of the house where peace and quiet are desired. • So as to provide easy access for filter maintenance (sometimes, by installing the unit upside down, it becomes easier to get at the filter). • Close to an exterior wall, so as to limit the length of the insulated flexible ducts to and from the unit. • Away from hot chimneys and other fire hazards. • Allow for a power source (standard 3-prong grounding outlet). 3.1 LOCATING AND MOUNTING THE UNIT • Phillips screwdriver no. 2 or Robertson no. 2 • Scissors or utility knife (to cut duct tape a

  • Broan-NuTone AE60, La bouche extérieure double doit être installée à une distance minimum de 18 po (457 mm) du sol. Voir l’illustration ci-contre. 1. À l’aide d’une scie va-et-vient, faire un trou de 6 po de diamètre dans le mur extérieur et y insérer la transition Tandem. 3. INSTALLATION DE L’APPAREIL (SUITE) 3.7 INSTALLATION DE LA (DES) BOUCHE(S) EXTÉRIEURE(S) (SUITE) 3.7.1 TRANSITION TANDEM AVEC LA BOUCHE EXTÉRIEURE DOUBLE (SUITE) VD0083F 18 po (457 mm) AVERTISSEMENT S’assurer que la bouche est à une distance d’au moins 6 pi (1,8 m) (ou plus, selon les codes et stand

  • Broan-NuTone AE60, 3. INSTALL THE UNIT (CONT’D) 3.5 INSTALLING 6’’ DUCTS AND REGISTERS (CONT’D) 3.5.3 SUGGESTED REGISTER LOCATIONS VA0032 BUNGALOW Basement stairwell (A): Open, lateral. One stale air exhaust register (1) in the highest lived-in level of the house and one fresh air distribution register (2) in the lowest lived-in level of the house. 1 2 A VA0033 BUNGALOW Basement stairwell (A): Closed. One stale air exhaust register (1) in the highest lived-in level of the house and one fresh air distribution register (2) in the lowest lived-in level of the house. For the closed stai

  • Broan-NuTone AE60, 1. YOUR UNIT AND ITS PURPOSE . . . . . . . . . . . . . . . . . . . . . . . . .4 2. TYPICAL INSTALLATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 2.1 Basement Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 2.2 Attic Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 2.3 Mounting Considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6 3. INSTALL THE UNIT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7 3.1 Locating and Mounting the Unit . . . . . . . . . . .

  • Broan-NuTone AE60, 22 1 . Débrancher l’appareil. 2. Nettoyer le filtre . • Retirer le filtre. • Passer l’aspirateur pour y enlever la plus grande partie des poussières. • Laver dans une solution d’eau chaude et de savon doux. De l’eau de Javel peut être ajoutée, si désiré (1 cuillerée à table par gallon). Rincer à fond. Secouer le filtre pour retirer l’excédent d’eau et laisser égoutter. NOTE : Il est possible de laver ce filtre au lave-vaisselle, dans le plateau du haut. Cependant, le cadre d’aluminium risque de ternir. 3. Rebrancher l’appareil. 4. Réinitialiser l’indicateur d’entretien des filtres en insérant un

  • Broan-NuTone AE60, 24 5.3 MASTER RESET 5. MAINTENANCE (CONT’D) Use the master reset only if you perform the annual maintenance before the annual maintenance indicator is on. By inserting a small rod (e.g.: paper clip end) during 5 seconds and more into the reset filter hole of the wall control, a master reset will be done and both biannual and annual maintenance filter are reset. If the wall control is in Off position, Fresh air light indicator will flash for 1 second. If the wall control is in Normal or Boost position, the unit motor and the Fresh air light indicator will turn off for 3 seconds. If the wall control is in Recirc

  • 9. Splice back the end of the cable to access the 4 wires. Remove the insulated sleeve of each wire ends. Connect each wires in their corresponding terminal (YELLOW in “Y”, RED in “R”, GREEN in “G” and BLACK in “B”). 10.Reinstall the electric box cover and plug the unit. 4. WALL CONTROL 4.1 INSTALLATION OF THE WALL CONTROL (CONT’D) 4.2

  • Broan-NuTone AE60, 4. Snap the assembled exterior hood on its backplate and secure with 2 provided screws (no. 8 x 3/4” long). 3. Lean the exterior backplate to the exterior wall. Using 4 no. 8 x 1½” screws, fix it to the wall. Seal the outline with caulking. 3. INSTALL THE UNIT (CONT’D) 3.7 EXTERIOR OPENING(S) INSTALLATION (CONT’D) 3.7.1 TANDEM TRANSITION WITH DUAL EXTERIOR HOOD (CONT’D) 2. Join the end of the Tandem transition to the rear of the exterior backplate. Secure with 2 Xmas tree pins and seal properly with duct tape. VD0085 CAUTION The exterior backplate must be installed with the word “TOP” pointing upward. Xmas tree pin VD00

  • 5. Passer l’autre bout du fil à travers le mur. À l’aide d’ancrages de gypse (non inclus) et des vis fournies, installer la commande au mur. Voir les illustrations ci-dessous. 1) Ancrages de gypse 4) Commande 1) Boîte de raccordement 3) Commande 2) Fil de la commande 5) Vis 2) Fil de la commande 4) Vis 3) Plaque arrière 6. Acheminer le fil à l’appareil. 7. Enlever le couvercle du b

  • Broan-NuTone AE60, 4. COMMANDE MURALE 4.1 INSTALLATION DE LA COMMANDE MURALE 18 AVERTISSEMENT Toujours débrancher l’appareil avant d’effectuer toutes connexions. Le fait de ne pas débrancher l’appareil pourrait créer un choc électrique, endommager l’appareil, endommager la commande murale ou le module électronique à l’intérieur de l’appareil. ! ATTENTION Ne jamais installer plus d’une commande murale par appareil. 1. Déterminer l’emplacement de la commande murale le plus commode pour vous. 2. Retirer la plaque (1) de la commande murale. Si vous

  • Broan-NuTone AE60, 3. INSTALL THE UNIT (CONT’D) 3.5 INSTALLING 6’’ DUCTS AND REGISTERS (CONT’D) 3.5.3 SUGGESTED REGISTER LOCATIONS (CONT’D) VA0035 MULTI-LEVEL Stairwell (A): Open, central. Two stale air exhaust registers (1) in the upper lived-in levels of the house and one fresh air distribution register (2) in the lowest lived-in level of the house. 1 1 2 A VA0036 COTTAGE Basement stairwell (A): Open. Two stale air exhaust registers (1) in the upper lived-in levels of the house and one fresh air distribution register (2) in the lowest lived-in level of the house. 1 1 2 A A VA0037 COTTAGE Basement stairwell (A): One part open, some parts closed (B). One stale air exhaust r

  • Broan-NuTone AE60, 3. INSTALLATION DE L’APPAREIL (SUITE) 3.7 INSTALLATION DE LA (DES) BOUCHE(S) EXTÉRIEURE(S) (SUITE) 3.7.2 EMPLACEMENT DES 2 BOUCHES EXTÉRIEURES Si l’installation de l’appareil doit être faite avec 2 bouches extérieures, se procurer une bouche extérieure additionnelle (bouche extérieure simple vendue séparément; numéro de pièce 13940). Choisir un endroit approprié pour l’installation des bouches extérieures. • La bouche extérieure double doit être située à au moins 4 pouces (102 mm) du sol. • La bouche extérieure simple doit être située à au

  • Broan-NuTone AE60, 5. Pass the other end of the cable through the wall. Reinstall the cover plate. Using wall anchors (not included) and provided screws, mount the wall control on the wall. See illustrations below. 1) Wall anchors 4) Control 1) Outlet box 3) Control 2) Control cable 5) Screws 2) Control cable 4) Screws 3) Control backplate 6. Route the cable to the unit. 7. Remove the electrical box cover on the side of the unit. 8. Slide the sleeve (included) over the cable control and pass the cable through the grommet. 1) Cable control 2) Sleeve 3) Grommet 4. WALL CONTROL (CONT’D) 4.1

  • 6 2. INSTALLATIONS TYPIQUES (SUITE) Cet appareil peut être utilisé pour en remplacer un déjà installé. Relier les conduits existants aux bouches correspondantes de l’appareil. Si les conduits d’origine d’évacuation d’air vicié et d’aspiration d’air frais sont de 5 po de diamètre, visser les adaptateurs de 5 po de diamètre (inclus) par dessus les bouches de 4 po

  • Broan-NuTone AE60, 22 1. Disconnect the power supply. 2. Clean filter • Remove filter. • Vacuum to remove most of the dust. • Wash with a mixture of warm water and mild soap. You may add bleach if you wish to disinfect (one tablespoon per gallon). Rinse thoroughly. Shake filter to remove excess water and let dry. NOTE: Washing the filter in the top tray of the dishwasher is possible, but the aluminum frame might tarnish. 3. Plug back the unit. 4. Reset the filter maintenance indicator by inserting a small rod (e.g.: paper clip end) into the reset filter hole of the optional wall control. Press lightly until the Filter Maintenance indicator light tur

  • Broan-NuTone AE60, 3. INSTALL THE UNIT (CONT’D) 3.7 EXTERIOR OPENING(S) INSTALLATION (CONT’D) 3.7.2 LOCATING 2 EXTERIOR HOODS If this unit installation needs to have 2 exterior hoods, an additional exterior hood must be bought (sold separately, single exterior hood, part number 13940). Choose an appropriate location for installing the exterior hoods. • The dual exterior hood must be located at a minimum distance of 4 inches (102 mm) from the ground. • The single exterior hood must be located at a minimum distance of 18 inches (457 mm) from the ground. • There must be a minimum distance of 6 feet (1.8 m) between the hoods to avoid cross-contamination. See figu

  • Broan-NuTone AE60, 7 3. INSTALLATION DE L’APPAREIL Choisir un bon emplacement pour l’appareil, éloigné des pièces où l’on recherche la tranquilité. • De façon à pouvoir accéder facilement au filtre, pour l’entretien (quelquefois, en installant l’appareil à l’envers, il est possible de faciliter cet accès). • Près d’un mur extérieur, afin de limiter la longueur des conduits flexibles isolés. • Éloigné des cheminées et autres risques d’incendie. • Prévoir une source d’alimentation électrique (prise standard 3 trous avec une mise à la terre). 3.1 EMPLACEMENT ET INSTALLATION DE L’APPAREIL • Un tournevis Phillips n° 2 ou Robertson n° 2 • Des ciseaux ou un

  • Broan-NuTone AE60, 2 ! AVERTISSEMENT AFIN DE RÉDUIRE LES RISQUES D’INCENDIE, D’ÉLECTROCUTION OU DE BLESSURES CORPORELLES, VEUILLEZ SUIVRE LES INSTRUCTIONS SUIVANTES : 1. Cet appareil a été conçu pour usage résidentiel seulement. 2. N’utilisez cet appareil que de la façon prévue par le manufacturier. Si vous avez des questions, contactez le manufacturier à l’adresse ou au numéro de téléphone indiqués dans le texte de la garantie. 3. Avant de remplacer les filtres, de nettoyer ou de réparer l’appareil, déb

  • Broan-NuTone AE60, AE60 / EA 1500 / HV 1.5 VB0063 Guide d’installation et d’utilisation Adresse de votre installateur 06095 rév. A USAGE RÉSIDENTIEL SEULEMENT INSTALLATEUR : LAISSER CE GUIDE AU PROPRIÉTAIRE. PROPRIÉTAIRE : INSTRUCTIONS D’UTILISATION ET D’ENTRETIEN EN PAGES 20 À 24. LIRE ET CONSERVER CES INSTRUCTIONS

More Instructions:

DOWNLOAD

Related Products and Documents (Air Cleaner):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 SeaLand 3000 Owner's manual sealand/3000-J94.pdf 12 Jan 2023 24 1.13 Mb
2 Lennox XP16?024?230 Installation instructions manual lennox/xp16-024-230-KF5.pdf 26 Jul 2023 43
3 Connected Essentials Splash-proof Operation & user’s manual connected-essentials/splash-proof-PON.pdf 18 Jun 2023 5
4 LightSpeed Technologies Wall Speaker Specifications lightspeed-technologies/wall-speaker-9OA.pdf 29 May 2023 1
5 EarthQuake SWS-6.5X Installation reference manual earthquake/sws-6-5x-7S2.pdf 05 Sep 2022 6 0.08 Mb
6 Roland G-33 Owner's manual roland/g-33-4RL.pdf 17 Aug 2023 6 1.56 Mb

Similar Resources:

  • Alpina

    SF-5068

    (45 pages)
    EN SF‐5068AirPurifierInstructionforuseDE SF‐5068 Luftreiniger BedienungshinweiseFR SF‐5068Purificateurd’air Moded`emploiIT SF‐5068Purificatored’aria Manualed´usoNL SF‐5068Luchtreiniger GebruiksaanwijzingSW SF‐5068Luftrenare …
  • Ultravation

    PHOTRONIC UVMatrix CW Series

    (4 pages)
    PHOTRONIC UVMatrixTM CW Series Standalone Air Cleaning System OWNERS GUIDE Models: 70-001, 70-002 Table of Contents: Page 2- Shipping and Packaging list, Introduction and Application, Safety Precautions, Installation Requirements Page 3- Maintenance, Germicidal UVC Lamp replacement, General Dime …
  • PUR

    PD-890AIV

    (10 pages)
    OWNER’S MANUAL MODEL PD-890AIV DELUXE CONSOLE ELECTRONIC AIR CLEANER, IONIZER & VOC FILTER IMPORTANT: PLEASE READ MANUAL BEFORE OPERATING UNIT Features  Lifetime Electronic Filter never needs replacing — simply washes clean  Electronically removes dust, mites, pollen, pet dander, mold, bacteria, viruses, tobacco s …
  • Hunter

    ExtremeAir HPF500

    (16 pages)
    EnglishModels:HPF500HPF500WHSHPF500BLSHPF500GRSHPF500WHRExtremeAir® Air PurifierWith True HEPA and EcoSilver® Pre-FilterForm #HPF50020200611©2020 Produced exclusively for Mindful, LLC under license by Hunter Fan Company All rights reserved …
  • FRANCO

    RoofCooler

    (24 pages)
    INSTRUCTION MANUAL FOR USE AND MAINTENANCE ROOF COOLER EVAPORATIVE COOLER E N G L I S H Before installing or running the unit, it is obligatory to carefully read and consult this manual. Manual version: 06-011/2020 Franco srl – Via Nazionale, 80 12010 Cervasca (CN) INDEX …
  • Trox Technik

    PURELINE50

    (16 pages)
    Product overviewFig. 1: Schematic illustration of PL50-*-SF①Diffuser face (with 1- to 4‑slots)②Adjustable air control element③Screw fixing④End plate⑤End angle⑥Neck⑦Plenum box⑧Suspension lug⑨Connector⑩Lip seal⑪Damper unit for volume flow rate balancingOptional equipment: ③ ④ ⑤ ⑩ ⑪Installation instructionsGB/enAir diffusersSlo …

Comments, Questions and Opinions: