Cabletron Systems SWPIM-BRI Installation Manual
|
Cabletron Systems SWPIM-BRI, Environmental Requirements SWPIM-BRI Installation Guide A-3 A.2.2 Pinout for the U-Interface Connector The network interface pin assignments for the U-interface network connector are listed in Table A-2. The connector for the U-interface is shown in Figure A-2: Figure A-2 U-Interface RJ48 Pinout A.3 ENVIRONMENTAL REQUIREMENTS Table A-2 Pinouts for the U-Interface Connection Pin Signal Direction 1 No Connection 2 No Connection 3 Uline I/O 4 Uline I/O 5 No Connection 6 No Connection Operating Temperature: +5° to +40°C (41° to 104°F) Non-o
Cabletron Systems SWPIM-BRI, SWPIM-BRI Installation Guide B-3 AFFIDAVIT FOR THE CONNECTION OF CUSTOMER EQUIPMENT TO 1.544 MBPS AND/OR SUBRATE DIGITAL SERVICES For the work to be performed in the certified territory of Telco’s name: State of: Country of: I, , of (Name of Authorized Representative) (Customer Name)
Cabletron Systems SWPIM-BRI, SWPIM-BRI Installation Guide xiii INTRODUCTION Welcome to the Cabletron Systems SWPIM-BRI Installation Guide . This manual gives an introduction to the SWPIM-BRI, lists features and capabilities, details the cabling pinouts, and explains how to install the SWPIM-BRI. The SWPIM-BRI provides S/T-interface (digital) functionality or U-interface (analog) functionality for a host platform designed to receive the SWPIM (Sliding WAN Physical Interface Module) architecture. USING THIS GUIDE Read through this guide completely to understand the features and capabilities of the SWPIM-BRI. A general working knowledge of WAN and Ethernet and IEEE 802.
Cabletron Systems SWPIM-BRI, Notice SWPIM-BRI Installation Guide v CABLETRON SYSTEMS SALES AND SERVICE, INC. PROGRAM LICENSE AGREEMENT IMPORTANT: THIS LICENSE APPLIES FOR USE OF PRODUCT IN THE UNITED STATES OF AMERICA AND BY UNITED STATES OF AMERICA GOVERNMENT END USERS. BEFORE OPENING OR UTILIZING THE ENCLOSED PRODUCT, CAREFULLY READ THIS LICENSE AGREEMENT. This document is an agreement (“Agreement”) between You, the end user, and Cabletron Systems Sales and Service, Inc. (“Cabletron”) that sets forth your rights and obligations with respect to the Cabletron software program (“Program”) in the package. The Program may be contained in firmware, chips or other media.
Cabletron Systems SWPIM-BRI, SWPIM-BRI Installation Guide i NOTICE Cabletron Systems reserves the right to make changes in specifications and other information contained in this document without prior notice. The reader should in all cases consult Cabletron Systems to determine whether any such changes have been made. The hardware, firmware, or software described in this manual is subject to change without notice. IN NO EVENT SHALL CABLETRON SYSTEMS BE LIABLE FOR ANY INCIDENTAL, INDIRECT, SPECIAL, OR CONSEQUENTIAL DAMAGES WHATSOEVER (INCLUDING BUT NOT LIMITED TO LOST PROFITS) ARISING OUT OF OR RELATED TO THIS MANUAL OR THE INFORMATION CONTAINED IN IT, EVEN IF CABLETRON SYSTEMS HAS BEE
Cabletron Systems SWPIM-BRI, SWPIM-BRI Installation Guide xi CONTENTS INTRODUCTION Using This Guide.......................................................................... xiii Structure of This Guide.................................................................xiv SWPIM-BRI Features...................................................................xiv Related Manuals............................................................................xv Document Conventions ................................................................xvi Getting Help................................................................................. xvii CHAPTER 1 INSTALLATION 1.1 Unpacking the SWPIM-BRI ................
Cabletron Systems SWPIM-BRI, Introduction xvi SWPIM-BRI Installation Guide DOCUMENT CONVENTIONS The following conventions may be used in this document: NOTE Note symbol. Calls the reader’s attention to any item of information that may be of special importance. TIP Tip symbol. Conveys helpful hints concerning procedures or actions. ! CAUTION Caution symbol. Contains information essential to avoid damage to the equipment. Electrical Hazard Warning symbol. Warns against an action that could result in personal injury or death due to an electrical hazard.
Cabletron Systems SWPIM-BRI, Appendix A: Specifications A-4 SWPIM-BRI Installation Guide A.4 REGULATORY COMPLIANCE This equipment meets the following safety and electromagnetic compatibility (EMC) requirements: Safety UL 1950, CSA C22.2 No. 950, 73/23/EEC, EN 60950, IEC 950, EN 60825 Electromagnetic Compatibility (EMC) FCC Part 15, CSA C108.8, 89/336/EEC, EN 55022, EN 61000-3-2, EN 61000-3-3, EN 55024, AS/NZS 3548, VCCI V-3 Telecommunications FCC CFR47 Part 68, CS-03
Cabletron Systems SWPIM-BRI, Appendix B: FCC Part 68 - User’s Information B-4 SWPIM-BRI Installation Guide I attest that the operator(s) maintainer(s) of the digital CPE responsible for the establishment, maintenance and adjustment of the encoded analog content and billing information has (have) been trained to perform these functions by successfully completing one of the following: Check appropriate one(s). a. A training course provided by the manufacturer/grantee of the equipment used to encode analog signals; or b. A training course provided by t
Cabletron Systems SWPIM-BRI, Introduction SWPIM-BRI Installation Guide xvii GETTING HELP For additional support related to this device or document, contact Cabletron Systems using one of the following methods: Before calling Cabletron Systems, have the following information ready: • Your Cabletron Systems service contract number • A description of the failure • A description of any action(s) already taken to resolve the problem (e.g., changing mode switches, rebooting the unit, etc.) • The serial and revision numbers of all involved Cabletron Systems products in the network • A description of your
Introduction xiv SWPIM-BRI Installation Guide STRUCTURE OF THIS GUIDE This guide is organized as follows: This Introduction provides preliminary information that will aid in using this manual, lists technology and user’s guides that may help the user to set up and manage the SWPIM-BRI, gives an overview of the SWPIM-BRI and its features, and information on how to
Cabletron Systems SWPIM-BRI, Chapter 1: Installation 1-4 SWPIM-BRI Installation Guide 1.3 LANVIEW LED INDICATIONS Refer to Table 1-1 for the link LED indications for the SWPIM-BRI. Refer to Table 1-2 for the status LED indications for the SWPIM-BRI. Table 1-1 Link LED Color Indication Off Disabled or Not Configured Red No Link Blinking Red Failure Blinking Amber Transmit or Receive Traffic Green Port is Active Table 1-2 Status LED Color Indication Off Normal or Disabled Blinking Amber Port in Loopback Test Mode Green Active Call (B1 and/or B2 is Active) Blinking Green Failure due to Framing Errors
Cabletron Systems SWPIM-BRI, Connecting to the Network SWPIM-BRI Installation Guide 1-5 1.4 CONNECTING TO THE NETWORK Figure 1-2 depicts a typical configuration for the SWPIM-BRI. The Cabletron Systems part number for the cable is 9360005-x, where x is the length of the cable. Figure 1-2 Typical Configurations 1.5 COMPLETING THE INSTALLATION After installing the SWPIM-BRI, the SWPIM-BRI will need to be configured for the network. Refer to the host platform software documentation in order to set up and manage the SWPIM-BRI using the software. SSR-600 SWPIM-BRI S/T-interface Site 2 WAN Cloud NT SSR-600 SWPIM-BRI U-interface Site 1 U-interface
Introduction SWPIM-BRI Installation Guide xv RELATED MANUALS The following Cabletron Systems manuals may help the user to set up and manage the SWPIM-BRI: SSR-600 Installation Guide HSIM-SSR-600 Installation Guide 6C105 SmartSwitch 6000 Overview and Setup Guide Ethernet Technology Guide Cabling Guide The manuals referenced above can be obtained on the World W
Cabletron Systems SWPIM-BRI, Notice SWPIM-BRI Installation Guide iii CABLETRON SYSTEMS, INC. PROGRAM LICENSE AGREEMENT IMPORTANT: THIS LICENSE APPLIES FOR USE OF PRODUCT IN THE FOLLOWING GEOGRAPHICAL REGIONS: CANADA MEXICO CENTRAL AMERICA SOUTH AMERICA BEFORE OPENING OR UTILIZING THE ENCLOSED PRODUCT, CAREFULLY READ THIS LICENSE AGREEMENT. This document is an agreement (“Agreement”) between You, the end user, and Cabletron Systems, Inc. (“Cabletron”) that sets forth your rights and obligations with respect to the Cabletron software program (“Program”) in the pack
Cabletron Systems SWPIM-BRI, Appendix B: FCC Part 68 - User’s Information B-2 SWPIM-BRI Installation Guide 8. In the event of equipment malfunction, all repairs should be performed by our Company or an authorized agent. It is the responsibility of the users requiring service to report the need for service to our Company or to one of our authorized agents. Service can be obtained at Cabletron Systems Technical Support: Address: Cabletron Systems, Inc. 35 Industrial Way Rochester, NH 03867-0505 Phone: (603) 332-9400 Internet mail: [email protected]
Cabletron Systems SWPIM-BRI, Notice iv SWPIM-BRI Installation Guide If the Program is exported from the United States pursuant to the License Exception TSR under the U.S. Export Administration Regulations, in addition to the restriction on transfer set forth in Sections 1 or 2 of this Agreement, You agree not to (i) reexport or release the Program, the source code for the Program or technology to a national of a country in Country Groups D:1 or E:2 (Albania, Armenia, Azerbaijan, Belarus, Bulgaria, Cambodia, Cuba, Estonia, Georgia, Iraq, Kazakhstan, Kyrgyzstan, Laos, Latvia, Libya, Lithuania, Moldova, North Korea, the People’s R
Cabletron Systems SWPIM-BRI, Notice ii SWPIM-BRI Installation Guide INDUSTRY CANADA NOTICE This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications. Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la class A prescrites dans le Règlement sur le brouillage radioélectrique édicté par le ministère des Communications du Canada. NOTICE: The Industry Canada label
Cabletron Systems SWPIM-BRI, Appendix A: Specifications A-2 SWPIM-BRI Installation Guide A.2 NETWORK INTERFACE The SWPIM-BRI uses an RJ48 connector for the network port, with two separate pinouts, one for the S/T-interface and the other for the U-interface. The Cabletron Systems Part Number for the cable for both the S/T-interface and the U-interface is 9360005-x, where x is the length of the cable. A.2.1 Pinout for the S/T-Interface Connector The connector for the S/T-interface can be seen in Figure A-1: Figure A-1 S/T-Interface RJ48 Pinout Table A-1 Pinouts for the S/T-Interface Connection Pin Function Polarity Terminal Equipment (TE) Network Equipmen
Cabletron Systems STH 24 STH-24 Network Card Operation & user’s manual
STH 24 STH-24 |
Cabletron Systems CBUQBR Network Card Operation & user’s manual
CBUQBR |
Cabletron Systems 6H133-37 Network Card Operation & user’s manual
6H133-37 |
Cabletron Systems 9000 Network Card Appendix
9000 |
Cabletron Systems CBU-NM Network Card Operation & user’s manual
CBU-NM |
Cabletron Systems Spectrum EMM-E6 Network Card Addendum manual
Spectrum EMM-E6 |
Cabletron Systems MMAC-Plus 9T125-24 Network Card Operation & user’s manual
MMAC-Plus 9T125-24 |
Cabletron Systems 9E132-15 Network Card Appendix
9E132-15 |
# | Manufacturer | Model | Document Type | File | Updated | Pages | Size |
---|---|---|---|---|---|---|---|
1 | Zanussi | ZWR 290 | Instruction book | zanussi/zwr-290-549.pdf | 24 Mar 2024 | 8 | 0.84 Mb |
2 | Aiphone | JF-1FD | Installation & operation manual | aiphone/jf-1fd-OWS.pdf | 08 Mar 2024 | 8 | 1.62 Mb |
3 | Senco | SNS40 | Specification sheet | senco/sns40-BX1.pdf | 17 Mar 2024 | 1 | 0.1 Mb |
4 | Electrolux | ECN 4157 | Operation and installation manual | electrolux/ecn-4157-B47.pdf | 13 Feb 2023 | 12 | 0.46 Mb |
5 | Toastmaster | B1048 | Use and care manual | toastmaster/b1048-4W8.pdf | 29 Jun 2023 | 4 | 0.04 Mb |
6 | Ericsson | MGM 148 | Maintenance manual | ericsson/mgm-148-Q3J.pdf | 21 Oct 2023 | 76 | 3.66 Mb |
Oki
Windows Installations □ Windows TCP/IP Network Installation .. 2□ Windows USB Local Installation ............ 6Macintosh Installations□ Macintosh Installation: Connections .... 10□ Macintosh Installation: Software ......... 11Service and SupportFirst …Consult the store where you purchased your printer.Additional OKI Resources䊳Available 24 hours a …
C3200n(24 pages) |
ADTRAN
1Section 61245201L1-5, Issue 361245201L1-5CFNID and T200 FNIDFractional T1 Network Interface DeviceInstallation and MaintenanceCONTENTS1. GENERAL ............................................................................ 12. INSTALLATION.................................................................. 23. CONNECTIONS....................................... …
FNID(16 pages) |
Socket
56K Modem Card CompactFlash modem card and software for adding connectivity to the following mobile computers: • Pocket PC 2000/2002/2003 • Handheld PC, Handheld PC Pro and HPC 2000 • Casio BE-300 Cassiopeia Pocket Manager • Windows 950B/98/Me/2000/XP notebook User’s Guide
…
Cordless 56K Modem(57 pages) |
LevelOne
1 LevelOne WUA-0605 300Mbps Wireless USB Network Adapter Quick Installation Guide English Deutsch Français Español Nederlands Dansk Italiano Ελληνικά Português Svenska Slovenščina 繁體中文 한국어 Русский Pols
…
WUA-0605(19 pages) |
Tyco
www.cemsys.comOVERVIEWThe Ethernet Input Output Controller (EIOC) is an addition to the Ethernet suite of devices for use on the AC2000 system. Connecting to the nearest network point the EIOC provides a flexible means to monitor and control an array of equipment.The EIOC features 16 analogue inputs and 8 digital outputs. The 16 analogue inputs can be cross …
Ethernet Input Output Controller EIOC(2 pages) |
Roland
1VS-2480/2480CD Q&ABASIC FUNCTIONSQ: What are the main differences between VS-2480/2480CD and VS-1880/1824?A: Main differences from VS-1880/1824 are as follows.• Accommodates 96kHz sampling rate• 24-bit linear recording• 2x R-BUS ports• Newly developed pre-amp circuit on analog input• Increased number of analog input jacks• 17 motorized fader …
VS-2480(9 pages) |
Roto Zip Tool Kitchen Appliances RZUser Guide: Roto Zip Tool RZ (T6H9SL, Upd.Tue 11.2023) RZ, 2 |
RYKOV Blower MK 110RYKOV MK 110 User Guide (Doc Type: Blower Operating instruction) MK 110, 27 |
JVC LCD TV LT-32C31BJEJVC LCD TV LT-32C31BJE Service manual LT-32C31BJE, 155 |
Interlogix DVR TruVision DVR 42#3Q728N: TruVision DVR 42 DVR Operation & user’s manual TruVision DVR 42, 184 |
Ecodyne Water Systems Water System EPWHCWWater System Installation and operation manual (Ecodyne Water Systems EPWHCW) EPWHCW, 24 |
Makita Battery Charger DC18RA#M7ZZM3 DC18RA: Makita Battery Charger Owner Documentation DC18RA, 12 |
Miele Oven H6461BPOven PDF Operating and installation instructions H6461BP, 132 |
Majestic fireplaces Indoor Fireplace PerfectView 33LDVGuide: Majestic fireplaces PerfectView 33LDV (Y747D1, Upd.23.12.2023) PerfectView 33LDV, 4 |
Velleman Test Equipment HPG1MK2Velleman HPG1MK2 Test Equipment User manual and information manual HPG1MK2, 6 |
Tote Vision Monitor LCD-640PDF Manual (@866M5Y), Tote Vision LCD-640 Monitor (Saturday 17-02-2024) LCD-640, 4 |
Epson Printer Stylus C66Stylus C66 Specification sheet - V7743O Stylus C66, 10 |
Cochlear Recording Equipment Baha 5 SuperPowerOperation & user’s manual for Cochlear Baha 5 SuperPower Recording Equipment Baha 5 SuperPower, 58 |