Compaq Pro UPS 500 Operation And Reference Manual
|
Compaq Pro UPS 500, Operation 3-5 “ON” Mode ■ Function: ENABLES battery backup. ■ UPS Conditions: The UPS battery is charging. Power is ON at the UPS receptacles. The green LINE STATUS indicator ( ) is illuminated. ■ Setting Advantages: Provides battery backup in the event of a blackout or brownout. “STANDBY” Mode ■ Function: DISABLES battery backup. ■ UPS Conditions: The UPS battery is charging. Power is ON at the UPS receptacles. The green LINE STATUS indicator ( ) is flashing. The UPS audio alarm is sounding once per minute. ■ Setting Advantages: Continues to charge
Compaq Pro UPS 500, 1-4 Compaq Pro UPS 500 Operation and Reference Guide Rear Panels The Compaq Pro UPS 500 models feature the following rear panel configurations: 2 5 6 4 3 1 Figure 1-2. Rear panel configuration - 100VA and 120VA models Communications port Battery compartment Noise and surge-protected receptacles Battery, noise, and surge-protected receptacles Non-detachable input power cord with NEMA 5-15 plug RJ11 Phone/Fax Surge Protectors
Compaq Pro UPS 500, Index 3 connecting the Phone/Fax Surge Protector 2-5 requirements hardware 2-2 software 2-2 tools 2-2 starting the UPS 2-7 L LINE STATUS indicator 3-10 load calculating total load (VA) 2-6 overload 2-6 M mode of operation Automatic Shutdown mode 3-5 Automatic Voltage Regulation (Boost mode) 3-6 Battery Operate mode 3-5 ON mode 3-5 STANDBY mode 3-5 O ON BATTERY indicator 3-10 Battery Operate mode 3-5 illuminated 3-5 ON mode 3-5 Operating mode selecting 3-3 operating the UPS BATTERY LOW/ALARM indicator illuminated 3-5 ON BATTERY
Compaq Pro UPS 500, Introduction 1-7 For example, if the software detects an extended utility power blackout, the program will initiate messaging across the system and will start an operating system shutdown. For more information on using the Compaq Power Manager Pro UPS software, see Chapter 4, “Software.” NOTE: Select Compaq NeoServers have UPS power management software preinstalled. Some NeoServer customers may not need to install Compaq Power Manager Pro UPS software. Please see the NeoServer documentation included with the NeoServer unit for specific power managem
Compaq Pro UPS 500, Appendix A Regulatory Compliance Notices Federal Communications Commission Notice Part 15 of the Federal Communications Commission (FCC) Rules and Regulations has established Radio Frequency (RF) emission limits to provide an interference-free radio frequency spectrum. Many electronic devices, including computers, generate RF energy incidental to their intended function and are, therefore, covered by these rules. These rules place computers and related peripheral devices into two classes, A and B, depending upon their intended installation. Class A devices are those that may reasonably be expected to be in
Compaq Pro UPS 500, Introduction 1-5 5 4 3 1 2 Figure 1-3. Rear panel configuration - 230VA model Communications port Battery compartment Noise and surge-protected receptacle Battery, noise, and surge-protected receptacles IEC-320 power inlet
Compaq Pro UPS 500, 2-8 Compaq Pro UPS 500 Operation and Reference Guide Connecting Devices to the Battery-and-Surge-Protected Receptacles Plug the equipment that needs battery backup support in the event of a blackout (such as the computer, monitor, and external modem) into the Battery-and-Surge-Protected receptacles ( ) on the UPS rear panel. The 100VA/120VA (left) and 230VA (right) models are illustrated below. 1 1 Figure 2-3. Connecting devices to the Battery-and-Surge-Protected receptacles ( )
Compaq Pro UPS 500, 3-14 Compaq Pro UPS 500 Operation and Reference Guide RJ11 Phone/Fax Surge Protector Select Compaq Pro UPS 500 models include a Phone/Fax Surge Protector to safeguard communications equipment (such as a fax machine or a modem) from spikes and surges from transients present on telephone lines. Communications Port The communications port connects the UPS to any computer or workstation. Use the communications port with Compaq Power Manager Pro UPS software to enable automatic shutdown and power management functionality. Surge-Protected Receptacle(s) These receptacles provide connected equipment with AC line power during normal operation. They also safeguard equipment against damaging sur
Compaq Pro UPS 500, About This Guide viii Getting Help If you have a problem and have exhausted the information in this guide, you can get further information and other help in the following locations. Compaq Technical Support In North America, call the Compaq Technical Phone Support Center at 1-800-OK-COMPAQ (1-800-652-6672) 1 . This service is available 24 hours a day, 7 days a week. Outside North America, call the nearest Compaq Technical Support Phone Center. Telephone numbers for world wide Technical Support Centers are listed on the Compaq website. Access the Compaq website at: http://www.compaq.com. Be sure to have the following information available before calling Compaq: ■ Techni
Compaq Pro UPS 500, 1-2 Compaq Pro UPS 500 Operation and Reference Guide Compaq Pro UPS 500 Models The Compaq Pro UPS 500 includes the following models and part numbers: Table 1-1 Compaq Pro UPS 500 Model Descriptions UPS Model UPS Kit Part Number Comments 500 136386-001 120VA; North America; Tower 500 136386-291 100VA; Japan; Tower 500 136386-B31 230VA; International; Tower Table 1-2 Compaq Pro UPS 500 Model – Additional Part Information UPS Model Spare Parts Kit Number RJ11 Phone/Fax Surge Protector Cable Part Number 500 155373-1 112666-010 500 155373-291 112666-010 500 155373-2 Not Applicable
Compaq Pro UPS 500, 3-2 Compaq Pro UPS 500 Operation and Reference Guide Operation Precautions Observe these precautions when using the UPS. WARNING: To reduce the risk of personal injury from earth conductor leakage current: ■ Do not operate a UPS that is disconnected from the utility power source. ■ Disconnect protected devices from the UPS before disconnecting the UPS from utility power. ■ Use the TEST/ALARM RESET button to test the battery rather than unplugging the UPS. For more information, see “Initiating a UPS Self-
Compaq Pro UPS 500, 3-8 Compaq Pro UPS 500 Operation and Reference Guide TEST/ALARM RESET Button The TEST/ALARM RESET button ( ) is a momentary switch that allows you to initiate a UPS self-test or silence an audio alarm. Initiating a UPS Self-Test 2 31 Figure 3-4. Initiating a UPS self-test BATTERY LOW/REPLACE indicato r UPS LOAD indicato r TEST/ALARM RESET button In the ON mode, pressing and holding the TEST/ALARM RESET button ( ) (until the UPS acknowledges with a beep) will initiate a self-test of the UPS battery, full function of the backup system, and the load condition of the Battery-and-Surge-Protected receptacles. During
Compaq Pro UPS 500, Introduction 1-3 Front Panels The Compaq Pro UPS 500 models feature the following front panel configuration: 5 62 3 41 Figure 1-1. Front panel configuration Symbol ON/STANDBY button LINE STATUS indicator ON BATTERY indicator BATTERY LOW/REPLACE indicator UPS LOAD indicator TEST/ALARM RESET button
Compaq Pro UPS 500, Operation 3-7 WARNING: To reduce the risk of personal injury resulting from electric shock or to avoid damage to the equipment: ■ Plug the input line cord into a grounded (earthed) electrical outlet that is installed near the equipment and is easily accessible. ■ Do not disable the grounding plug on the input line cord. The grounding plug is an important safety feature. ■ Do not use an extension cord. IMPORTANT: ■ Performing a UPS Start-On-Battery with load present requires more power than keeping an already-operating load running. You may not be able to start as large a load as usual when performing a UPS Start-On-Battery using the
Compaq Pro UPS 500, vii Compaq Pro UPS 500 Operation and Reference Guide Symbols in Text These symbols may be found in the text of this guide. They have the following meanings. WARNING: Text set off in this manner indicates that failure to follow directions in the warning could result in bodily harm or loss of life. CAUTION: Text set off in this manner indicates that failure to follow directions could result in damage to equipment or loss of information. IMPORTANT: Text set off in this manner presents clarifying information or specific instructions. NOTE: Text set off in this manner presen
Software 4-3 UPS Control Functions Perform the following UPS control functions, using the software security features to: ■ Protect access. ■ Execute a UPS self-test. ■ Shut down the operating system and UPS. Configuration Parameters System administrators and operators can configure Compaq Power Manager Pro UPS software parameters through the web-based int
3-6 Compaq Pro UPS 500 Operation and Reference Guide ■ Automatic Voltage Regulation (Boost) Mode: When an undervoltage occurs, the UPS will automatically correct the voltage level without switching to battery power. When this occurs, the UPS may emit a clicking sound. The more the UPS adjusts the voltage level, the more the UPS will click. This is a normal, auto
Compaq Pro UPS 500, About This Guide This guide is designed to be used as step-by-step instructions for installation and as a reference for operation, troubleshooting, and future upgrades. Text Conventions This document uses the following conventions to distinguish elements of text: Keys Keys appear in boldface. A plus sign (+) between two keys indicates that they should be pressed simultaneously. USER INPUT User input appears in a different typeface and in uppercase. FILENAMES File names appear in uppercase italics. Menu Options, Command Names, Dialog Box Names These elements appear in initial capital letters. COMMANDS, DIRECTORY NAMES, and DRIVE NAMES These elements appear in uppercase. Type Whe
Compaq Pro UPS 500, 3-10 Compaq Pro UPS 500 Operation and Reference Guide Front Panel Indicators and Audio Alarms The front panel indicators signal the status of the UPS. LINE STATUS Indicator (Green) The LINE STATUS indicator illuminates whenever the UPS is connected to acceptable AC utility line power. While the UPS is in the ON mode, the LINE STATUS indicator will remain constantly illuminated to indicate that battery backup is enabled and will be available at the Battery-and-Surge-Protected receptacles in the event of a blackout or brownout. While the UPS is in the STANDBY mode, this indicator will flash (and an alarm will sound
Battery Maintenance 5-3 When to Replace the Battery If the BATTERY LOW/REPLACE indicator ( ) illuminates during a self-test, the UPS may require service. The indicator will be accompanied by an audio alarm. 1 Figure 5-1. BATTERY LOW/REPLACE indicator ( ) Verify that battery replacement is required by allowing the UPS to charge the battery for 12 hours, then initiate a confirming self-test.
Compaq Pro UPS 500, Software 4-5 Installation Wizard Notification Compaq Power Manager Pro UPS software takes advantage of the Microsoft AutoPlay feature. To install Compaq Power Manager Pro UPS software using this Install Wizard, follow the steps below: 1. The Compaq Power Manager Pro UPS software Select Language screen is displayed when the CD-ROM is inserted into the drive. Select the desired language. Figure 4-1. Select Language Screen
Compaq Pro UPS 500, Installation 2-9 Connecting Devices to the Surge-Protected Receptacle(s) Plug non-critical equipment into the Surge-Protected receptacle(s) on the UPS rear panel, as illustrated in the following figure. The Surge-Protected receptacle(s) ( ) will provide connected peripherals with surge protection without committing valuable battery power to support the peripherals during blackouts. The 100VA/120VA (left) and 230VA (right) models are illustrated below. 2 2 Figure 2-4. Connecting devices to the Surge-Protected receptacles ( ) NOTE: When the UPS is con
CyberPower PR2200LCDSL UPS Operation & user’s manual
PR2200LCDSL |
Tripp Lite SU8000RT3U UPS Specifications
SU8000RT3U |
Compaq R1500 - UPS - Lead Acid UPS Specification
R1500 - UPS - Lead Acid |
Compaq Presario 3000 Series UPS Operation and reference manual
Presario 3000 Series |
Njoy Eris 600 UPS Operation & user’s manual
Eris 600 |
Cleanline D Series UPS Operation & user’s manual
D Series |
Delta M-1K UPS Operation & user’s manual
M-1K |
Compaq 1000 Series UPS Operation and reference manual
1000 Series |
# | Manufacturer | Model | Document Type | File | Updated | Pages | Size |
---|---|---|---|---|---|---|---|
1 | SMITH SYSTEM | Lift Desk | Assembly instructions manual | smith-system/lift-desk-M49.pdf | 10 Jan 2024 | 8 | |
2 | Philips | CED1910BT | Operation & user’s manual | philips/ced1910bt-D51.pdf | 28 Aug 2023 | 45 | 4.76 Mb |
3 | YASKAWA | NX100 | Instruction manual | yaskawa/nx100-768.pdf | 04 Jul 2023 | 88 | |
4 | REVELL | Concerta C10 | Owner's manual | revell/concerta-c10-NBZ.pdf | 22 Aug 2023 | 9 | 0.27 Mb |
5 | AMD | 7ZXR | Manual | amd/7zxr-Q2Z.pdf | 16 Jul 2022 | 119 | 1.83 Mb |
6 | Watec | WAT-704R | Operation manual | watec/wat-704r-X1V.pdf | 30 Sep 2023 | 1 |
Keatec Energy
Keatec RTM Series Modular Online UPS 208V/120Vac 2PH 2PH Rack AssemblyVersion: 2017-05-15User GuideUNLESS SPECIFICALLY AGREED TO IN WRITING, SELLER(A) MAKES NO WARRANTY AS TO THE ACCURACY, SUFFICIENCY OR SUITABILITY OF ANY TECHNICAL OR OTHER INFORMATION PROVIDED IN ITS MANUALS OR OTHER DOCUMENTATION;(B) ASSUMES NO RESPONSIBILITY OR LIABILITY FOR LOSSES, DA …
RTM Series(19 pages) |
CyberPower
BR650ELCD / BR850ELCD / BR1000ELCD / BR1200ELCD User’s Manual K01-C0000110-00 This manual contains important instructions that should be followed during installation and maintenance of the UPS and batteries. Please read and follow all instructions carefully during installation and operation of the unit. Read this manual thorou …
BR850ELCD(2 pages) |
Omron
• This manual provides important safety-related information. Thoroughly read and understand this manual before installing and using the product. • Keep this manual in a convenient location so that you can refer to it whenever necessary.Uninterruptible Power Supply (UPS)Instruction ManualBU50SW/BU75SW/BU100SW/BU150SW-バッテリ 交換バッテリ …
Powli BU50SW(74 pages) |
Power Walker
EN Line Interactive UPS PowerWalker VI 1000RT LCD PowerWalker VI 1500RT LCD PowerWalker VI 2000RT LCD PowerWalker VI 3000RT LCD Manual EN, DE
…
VI 1000RT LCD(75 pages) |
CyberPower
User’s Manual OL6000ERT3UD OL8000ERT3UD OL10000ERT3UD OL6KERT3UDPM OL8KERT3UDPM OL10KERT3UDPM Cyber Power Systems Inc. www.cyberpower.com K01-0000424-03
…
OL6KERT3UDPM(25 pages) |
GE
GuardSwitch™ Series 300341-BT341-BT-06(J)(K)341-BT-12(J)(K)341-BT-20K341-BT-25J341-B3T-06J341-B3T-12J341-B3T-20J341-B3T-25JSafety Interlock SwitchInstallationUse non-removable screws, bolts, or nuts to mount the switch and actuator. Do notover-torque mounting hardware.1. Position the switch and actuator so the labels are reading in the same direction(See F …
300(4 pages) |
Gallagher Battery Charger 3E3446 M5800iGallagher 3E3446 M5800i Battery Charger Instructions manual 3E3446 M5800i, 64 |
Ubiquiti Solar panel sunMAXSolar panel #FCP5R9 sunMAX, 60 |
Raritan Network Router CC-SGRaritan Network Router CC-SG Administrator's manual CC-SG, 258 |
Toyota Automobile 2015 AvalonOwner's manual for Toyota 2015 Avalon Automobile 2015 Avalon, 472 |
Speco Amplifier VID-DISTAmplifier PDF Specifications VID-DIST, 1 |
Sony Camcorder HDR-HC7Sony HDR-HC7 Guide (Doc Type: Camcorder Software manual) HDR-HC7, 34 |
Maytag Ranges CRE9900ACBMaytag CRE9900ACB User Guide (Owner's manual), @FY7689 CRE9900ACB, 26 |
Sony Flat Panel TV KDL-22BX300 - Bravia Bx Series Lcd Television#9G8V72: KDL-22BX300 - Bravia Bx Series Lcd Television Flat Panel TV Service manual KDL-22BX300 - Bravia Bx Series Lcd Television, 24 |
Zelmer Mixer 581Zelmer 581 Manual (Doc Type: Mixer Operation & user’s manual) 581, 42 |
Kramer Amplifier VM-1010Kramer Amplifier VM-1010 Operation & user’s manual VM-1010, 27 |
iLive Speaker System ITP100BSpeaker System PDF Operation & user’s manual ITP100B, 12 |