Compatible Systems Octal V.35 - 10/100 RIOP Installation Manual
|
Compatible Systems Octal V.35 - 10/100 RIOP, Octal V.35-10/100 RIOP Installation Guide, Version 1.0 Copyright© 1999, Compatible Systems Corporation All rights reserved. VSR, VSR-2, MicroRouter and CompatiView are trademarks of Compatible Systems Corporation. Other trademarks are the property of their respective holders. FCC Notice: This product has been certified to comply with the limits for a Class A computing device, pursuant to Subpart J of Part 15 of FCC Rules. It is designed to provide reasonable protection against radio or television communication interference in a commercial environment. Operation of this equipment in a residential area could cause interference with radio or televisio
Table of Contents i Introduction to the Octal V.35-10/100 RIOP 1 Chapter 1 - Network Installation 2 Connecting the Octal V.35-10/100 to the Ethernet 2 Telco Line Connection Requirements 3 Connecting a Line Device to the V.35 Interfaces 3 Connecting a Management Console 3 Powering Up the Router 3 Chapter 2 - Quickstart Instructions 4 ETHERNET INTERFACE CONFIGURATION 4 IP Protocol 4
Table of Contents ii Required for IP Unnumbered Interface 8 Suggested for IP 9 IPX Protocol 9 Required for IPX 9 Suggested for IPX 9 AppleTalk Protocol 9 Required for AppleTalk 9 Suggested for AppleTalk 9 DECnet Protocol 10 Required for DECnet 10 SMDS Configuration 10 Link Configuration 10 SMDS Addressing 10 SAVING A CONFIGURATION FILE TO FLASH ROM 10 Chapte
Compatible Systems Octal V.35 - 10/100 RIOP, Introduction to the Octal V.35-10/100 RIOP 1 Introduction to the Octal V.35-10/100 RIOP The Octal V.35-10/100 Routing Input/Output Processor (RIOP), as part of the VSR multigi- gabit switching router, allows you to connect a local Ethernet and up to eight remote corporate networks. Each of the V.35 interfaces has a data capacity of up to 2.048 Mbps, while the Ethernet interface can operate at either 10 Mbps or 100 Mbps. This section of the manual contains information specific to the Octal V.35-10/100 RIOP. It is divided into the following sections: Chapter 1: Network Installation Here you will find step-by-step instructions on how to physically
Compatible Systems Octal V.35 - 10/100 RIOP, Chapter 1 - Network Installation 2 Chapter 1 - Network Installation Octal V.35-10/100 RIOP Front Panel This section of the manual will help you install the Octal V.35-10/100 RIOP to connect a local Ethernet and up to eight remote corporate networks. These connections can be made to other Compatible Systems devices or internetworking equipment from other vendors. In summary, the steps for installation are: 1. After mounting the router or placing it on a desktop, make sure it is not connected to any power source. 2. Connect the router to the Ethernet netw
Compatible Systems Octal V.35 - 10/100 RIOP, Chapter 1 - Network Installation 3 Telco Line Connection Requirements The Octal V.35-10/100 is not a line communications device. In order to connect each V.35 port to a wide area transmission line, you must use a 56K CSU/DSU, ISDN Terminal Adapter, or T1/E1 CSU/DSU. Which of these devices you use depends on the type of telco line you are connecting to. v Note: Before attempting to connect the Octal V.35-10/100 to a leased telco line, use the loopback features of your CSU/DSUs to check the line. This can save you a considerable amount of time, since the
Compatible Systems Octal V.35 - 10/100 RIOP, Chapter 2 - Quickstart Instructions 4 Chapter 2 - Quickstart Instructions This Quickstart chapter briefly discusses the major parameters that must be set in order to use the Octal V.35-10/100 RIOP as part of your VSR multigigabit switching router. Detailed information on the meaning of the router’s parameters is provided in the Compa- tiView Management Software Reference Guide and the Text-Based Configuration and Command Line Management Reference Guide. You should use this chapter as a starting point to look up more specific information in the other documents. If you need more general information
Compatible Systems Octal V.35 - 10/100 RIOP, Chapter 2 - Quickstart Instructions 5 Suggested for IP These parameters help supply information about the segment that the interface is connected to. With this information, routing can take place. • Set IP RIP 1, IP RIP 2 or OSPF (Open Shortest Path First) • IP static routes CV: Use the TCP/IP Routing: Ethernet 0 Dialog Box to set RIP, and the IP Static Routing Dialog Box (under Global/IP Static Routes) to set static routes. OSPF can only be configured using text-based configuration. TB: Use configure and set either the RIPVersion keyword or the OSPFEnabled keyword for the IP Ethernet 0 section. U
Compatible Systems Octal V.35 - 10/100 RIOP, Chapter 2 - Quickstart Instructions 6 In CompatiView you must set a global parameter and a port-specific parameter. Suggested for DECnet Setting the parameters above should be adequate for most installations. WAN Interface Configuration The default setting for all WAN interfaces on your Octal V.35-10/100 RIOP is Off for all protocols and for the link configuration. In order to use a WAN interface, you must first set some physical parameters and then set up the link and protocol parameters. Physical Communications Settings You may need to set the baud rate or other ph
Compatible Systems Octal V.35 - 10/100 RIOP, Chapter 2 - Quickstart Instructions 7 ured using text-based configuration. TB: Use configure and set either the RIPVersion keyword or the OSPFEnabled keyword in the IP WAN 0 (and/or any other port you wish to configure) section. Add static routes and a default router using the edit config IP Static command. v Note: Due to the complexity of BGP, configuration parameters for BGP are not given in this Quickstart. For help with BGP configuration parameters, and other configuration questions, refer to the Tech Support pages on the Compatible Systems Web site at: http://www.compatible.com/. IPX Protocol Required for IPX WAN interfaces
Chapter 2 - Quickstart Instructions 8 WAN Link Configuration Required for Dedicated Line Operation Frame Relay is presently supported in the Octal V.35-10/100 RIOP only via synchronous dedi- cated line operation. • Set Dedicated connection • Set Frame Relay connection CV: Use the Link Configuration: WAN Dialog Box. TB: Use configure and then set the Mode and ConnectMode keywords in the
Compatible Systems Octal V.35 - 10/100 RIOP, Chapter 2 - Quickstart Instructions 9 Suggested for IP These parameters help supply information about the segment that the interface is connected to. With this information, routing can take place. • Set IP RIP 1, IP RIP 2, OSPF (Open Shortest Path First) or BGP (Border Gateway Protocol) • IP static routes CV: Use the TCP/IP Routing: WAN Dialog Box to set RIP, and the IP Static Routing Dialog Box (under Global/IP Static Routes) to set static routes. OSPF and BGP can only be config- ured using text-based configuration. TB: Use configure and set either the R
Compatible Systems Octal V.35 - 10/100 RIOP, Chapter 2 - Quickstart Instructions 10 TB: Use configure and set keywords in the AppleTalk WAN 0 (and/or any other port you wish to configure) section. DECnet Protocol Required for DECnet In order to be used, DECnet must be turned on both globally and for a particular port. WAN interfaces which are set for Frame Relay operation do not need any additional parame- ters set in order to function. • Set DECnet on (globally, and for this port) CV: Use the DECnet Routing Dialog Box (under Global/DECnet Routing) and the DECnet: WAN
Compatible Systems Octal V.35 - 10/100 RIOP, Chapter 3 - Shipping Defaults 11 Chapter 3 - Shipping Defaults Ethernet Interface IP Routing Defaults • On • Address: 198.41.12.1 • Subnet Mask: 255.255.255.0 • Broadcast Address: 198.41.12.255 • IP RIP off IPX Routing Defaults • 802.3 on, autoseeding • 802.2 on, autoseeding • Type II on, nonseeding • 802.2 SNAP on, nonseeding AppleTalk Routing Defaults • Phase 1 off • Phase 2 on, autoseeding DECnet Defaults • Off WAN Interfaces • Off
Compatible Systems Octal V.35 - 10/100 RIOP, Chapter 4 - LED Patterns 12 Chapter 4 - LED Patterns Some of the LEDs on the front of the VSR multigigabit switching router serve dual functions. In addition to indicating certain router-wide operating conditions, they may also display port- specific information. v Note: Any continuous flashing pattern not noted in this chapter may be caused by a hard- ware failure. Please call Compatible Systems Technical Support if your router shows a hard- ware failure. Router LED Patterns The following LEDs and light patterns provide information about the VSR’s physical state and operating conditions. Over Temp The router is above the proper operating temperature. The fil
Compatible Systems Octal V.35 - 10/100 RIOP, Appendix A - Connector and Cable Pin Outs 13 Appendix A - Connector and Cable Pin Outs Pin Outs for HD D-Sub Male to V.35 Male Cable 1 Unused by the V.35 interface circuitry. 2 Receive Line Signal Detect (RLSD) must be asserted by the CSU/DSU when the WAN line is operational. The CSU/DSU should be configured to have (RLSD) follow the state of the link. 3 Data Terminal Ready (DTR) will be asserted by the VSR V.35 circuitry when the VSR is ready to communicate. 4 Used only when internal clocking has been sel
Compatible Systems RISC 3400R Network Router Installation manual
RISC 3400R |
Compatible Systems MicroRouter 2220R Network Router Installation manual
MicroRouter 2220R |
Compatible Systems DS3- Quad 10/100 RIOP Network Router Installation manual
DS3- Quad 10/100 RIOP |
Compatible Systems DS3- Quad 10/100 RIOP Network Router Installation manual
DS3- Quad 10/100 RIOP |
Aztech SDSL Bridge & Router Network Router User's & technical manual
SDSL Bridge & Router |
Compatible Systems MicroRouter 1200i Network Router Installation manual
MicroRouter 1200i |
Compatible Systems 1250I Network Router Installation manual
1250I |
Asus GX-D1051 Network Router Quick start manual
GX-D1051 |
# | Manufacturer | Model | Document Type | File | Updated | Pages | Size |
---|---|---|---|---|---|---|---|
1 | Califone | 8104 | Specifications | califone/8104-4MS.pdf | 02 Aug 2022 | 1 | 0.12 Mb |
2 | Thermador | CIT304KB | Brochure & specs | thermador/cit304kb-CEK.pdf | 11 Jul 2023 | 10 | 5.64 Mb |
3 | Robot Coupe | CMP250VV | Specifications | robot-coupe/cmp250vv-I2Q.pdf | 04 Jul 2022 | 2 | 0.74 Mb |
4 | Samsung | MW83U | Owner's instructions manual | samsung/mw83u-391.pdf | 23 Apr 2023 | 12 | 0.65 Mb |
5 | Ampeg | B410HE | Operation & user’s manual | ampeg/b410he-3OG.pdf | 21 Dec 2023 | 4 | 0.46 Mb |
6 | ViewSonic | VS13340 | Specification sheet | viewsonic/vs13340-R2T.pdf | 30 Oct 2022 | 2 | 0.45 Mb |
Cisco
Americas HeadquartersCisco Systems, Inc.170 West Tasman DriveSan Jose, CA 95134-1706 USAhttp://www.cisco.comTel: 408 526-4000800 553-NETS (6387)Fax: 408 527-0883Catalyst 2350 Switch Command ReferenceCisco IOS Release 12.2(46)EY February 2009Text Part Number: OL-19055-01
…
WS-C2350-48TD-S(652 pages) |
Huawei
1Modem Conguration GuideHG658 Conguring in Layer2 PPPoE for Windows 8IMPORTANT MESSAGEYour modem has already been pre-configured, you do not need to follow each step of the set-up guide but should retain this document in case you need to manually configure your equipment.To configure your PC/Laptop with your wireless password including changing your …
HG658(4 pages) |
SMC Networks
www.smc-europe.com www.smc.comADSL BarricadeTM gSMC7204BRB4-Port ADSL Router with Built-in Annex B ADSL ModemThe ADSL BarricadeTM (SMC7204BRB) is an external Ethernet standards based ADSL modem and Router that provides high-speed Internet access to both the residential and the small and home office (SoHo) user. This new Modem/Router provides unrivaled asymm …
7204BRB(2 pages) |
SingTel
Setting up your WiFi Connection You can nd the WiFi network name (SSID) and password on the base of your Wireless Router. To get help on connecting to WiFi on different operating systems and devices, go to: bit.ly/connwireless or scan the QR code on the right.Connecting a Home Digital LineConnect your home phone to “TEL 1” port in the ONT using a Tele …
AC1900(2 pages) |
KMC Controls
Complete the following steps to install a Conquest™ BAC-5051 BACnet Router.Refer to the Conquest BAC-5051E BACnet Router data sheet for router specic information on the web at kmccontrols.com.INSTALL CONTROLLERNOTE: Complete steps 1–2 to install the router with screws. Complete steps 3–7 to install the router on a 35 mm DIN rail.NOTE: Install the …
Conquest BAC-5051(3 pages) |
Linksys
PRODUCT DATABUSINESS SERIES4-Port Gigabit Security Router with VPNModel: RVS4000Secure, smart Gigabit networking for growing businessProtection of your network is a mission critical activity. At Linksys, we build powerful security into every product, to keep your wired and wireless networks safe. Linksys Small Business Series systems have advanced firewall, …
RVS4000(3 pages) |
Telex Monitor PAM-100PDF Guide (@O6YNA6), Telex PAM-100 Monitor (16/10/2023) PAM-100, 1 |
Luxman Amplifier P-750uLuxman Amplifier Owner's manual (File: luxman-p-750u-owner-s-manual-20, Sun 09.2023) P-750u, 20 |
Amped Wireless Extender RE1750A#6P3NQA RE1750A: Amped Wireless Extender Owner Documentation RE1750A, 2 |
Roland Synthesizer FA 08Synthesizer Application manual (Roland FA 08) FA 08, 16 |
IDTECH Card Reader Spectrum AirIDTECH Card Reader Operation & user’s manual (File: idtech-spectrum-air-operation-user-s-manual-39, Thursday 25-01-2024) Spectrum Air, 39 |
Lilly Insulin Pen Humalog KwikPen#676R6X: Humalog KwikPen Insulin Pen User manual manual Humalog KwikPen, 8 |
King Kooker Grill OUTDOOR COOKERS WITH GAS SHUT-OFF TECHNOLOGYKing Kooker OUTDOOR COOKERS WITH GAS SHUT-OFF TECHNOLOGY Grill Use and care manual OUTDOOR COOKERS WITH GAS SHUT-OFF TECHNOLOGY, 32 |
Omron Power Supply S8JX-P300 Series#6N34Q4 S8JX-P300 Series: Omron Power Supply Owner Documentation S8JX-P300 Series, 2 |
Morel Speakers VARIO SeriesMorel Speakers VARIO Series User manual and installation manual VARIO Series, 4 |
AT&T IP Phone TL96457TL96457 (IP Phone ePDF User Manual, #Z3CUQ6) TL96457, 213 |
Kenwood Receiver KRC-659RKenwood Receiver KRC-659R Instruction manual KRC-659R, 46 |
Supero Motherboard X7DCL-3X7DCL-3 (Motherboard ePDF Manual, #P31ZNG) X7DCL-3, 104 |