Manualios.com

Canon MLT (F) Operation & User’s Manual

  • MLT (F) Camera Accessories
  • maE7Tp6grtnrU
  • Operation & User’s Manual
  • PDF / Adobe Acrobat Reader
  • 40

Canon MLT (F) Manual Online:

4.9, 1393 votes
Canon MLT (F) User Manual
Canon MLT (F) User Guide
Canon MLT (F) Online Manual

Text of Canon MLT (F) User Guide:

  • Canon MLT (F), Continued on the following page >> 3.QA Mode Settings – 15 – 2 Select MLT (F) FREQUENCY If MLT (F) FREQUENCY is not currently selected (in this case, the DWT ENHANCE., DWT DEP, and DWT NOISE R. tabs are not displayed), touch the Frequency Pro- cessing Mode button to open the window, then touch [MLT (F) FREQUECY]. Frequency Processing Mode Window 3 Select the tab Touch the desired tab from among three tabs: DWT ENHANCE., DWT DEP, DWT NOISE R. 4 Change the parameters Set the parameters provide

  • Canon MLT (F), – 14 – 3. QA Mode Settings The examples used in this chapter are the screens of CXDI System Software version 6.3. 3.1 Procedures to Change Parameters Image processing of the exposure images with CXDI is called QA (Quality Assurance) Process- ing, and can be performed by adjusting the parameters on the QA Mode screen to optimize the exposure image. 1 Display the QA Mode screen Display the QA Mode screen by one of the following methods: QA Mode Screen To display the QA Mode screen automatically right after x-r

  • Canon MLT (F), Notation Conventions Notation 1 In this manual, the name of button is enclosed with a pair of brackets [ ], and the buttons that are selected in succession are connected with > to indicate the order. Example: On the Exposure screen, touch the followings: [SYSTEM] > [SETUP MENU] Operation: Touch the SYSTEM button on the first screen, and then touch the SETUP MENU button on the second screen. Touch the SYSTEM button (left), and then touch the SETUP MENU button (right) Notation 2 If any detailed explanation for the operation or setting is available on other page in this manual, the page to refer is indi- cated with (→ page number). Ex

  • Canon MLT (F), 3.QA Mode Settings – 26 – 3.4 Changing DWT Noise R. Tab 1 Set the DWT Noise Reduction effective Touch [NOISE REDUCTION] to display the parameters. The appearance of the button switches over between the highlight (in white outline characters against a colored back- ground) and normal display each time you touch the button. The parameters are available when the button is displayed in highlight. DWT NOISE R. Screen with Parameters 2 Set the EFFECT parameter Touch the or button, and set the val

  • Canon MLT (F), Continued on the following page >> – 27 – 4. QA Parameters When MLT(F) frequency processing is selected, the QA parameters (%IP_PARAM%) in Anno- tation are displayed in the format below. n stands for the numeric value, character or symbol displayed on Annotation. 1 REX The parameter is displayed as follows: REXn If LUT is set to REX ADJUST for x-ray exposure, F-REX is displayed. 2 Frequency Processing Mode If MLT (F) FREQUENCY is selected as the Frequency Processing Mode, Q1 is displayed. Q0 is displayed for STD. FREQUENCY, and Q2 displayed for MLT (M) FREQUENCY. For other QA parameters displayed when the mode

  • – 23 – 3.QA Mode Settings 3 Display the MORE window Touch [MORE] to open the window. MORE Window 4 Set the HIGH WEIGHT parameter Touch the or button, and set the value within the range between 0 to 20. The value on the left is the setting saved previously, and the value on the right is the cur- rent setting. For details of the parameter, refer to the step 3 in

  • Canon MLT (F), 2.Edit Exposure Mode Settings – 4 – 4 Select the Exposure Mode Make sure that [EDIT PARA.] at the top-left is highlighted, and select the desired Expo- sure Mode. The EDIT PARA. screen appears. EDIT PARA. Screen (first page) 5 Display the next page Touch [NEXT PAGE]. EDIT PARA. Screen (second page) Availability of Frequency Processing Mode If your CXDI System Software is the version 5.0 or before, there is no need to select the frequency processing mode as described in the next step (step 6). Skip the step 6 and proceed to the step 7.

  • Canon MLT (F), – 21 – 3.QA Mode Settings . Switching the display of the graph Touch the graph area to switch over the Frequency Base Graph (bar graph) and Density Base graph (line graph). Actual processing shall not be performed unless the DWT Edge Enhancement is effective, although the graph is displayed on the screen. Frequency Base Graph (Bar Graph) Density Base Graph (Line Graph)

  • Canon MLT (F), – 25 – 3.QA Mode Settings 3 Display the MORE window Touch [MORE] to open the window. MORE Window 4 Set the LOW WEIGHT parameter Touch the or button, and set the value within the range between 0 to 20. The value on the left is the setting saved previously, and the value on the right is the cur- rent setting. For details of the parameter, refer to the step 3 in 2.3.2 Setting DWT DEP for Low- Density Field (→ P.12) . 5 Set the LOW EFFECT parameter Touch the or button, and set the value within t

  • Canon MLT (F), 3.QA Mode Settings – 16 – 5 Save the new parameters To save new parameters as the default values of the Exposure Mode (except opening from Study List), touch [SAVE PARAM]. The window displaying the following message appears: Are you sure you want to change the default generator parameters? Then, touch [YES]. 6 Close the QA Mode screen Touch [OK]. When Password is required If the password is specified, a different message is displayed as follows: Administrator’s authority is needed. Enter system password. In this case, touch within the frame

  • Canon MLT (F), Continued on the following page >> 3.QA Mode Settings – 17 – 3.2 Changing DWT ENHANCE. Tab 1 Set the DWT Edge Enhancement effective Touch [DWT EDGE ENHANCE.] to display the parameters. The appearance of the but- ton switches over between the highlight (in white outline characters against a colored background) and normal display each time you touch the button. The parameters are available when the button is displayed in highlight. DWT ENHANCE. Screen with Parameters 2 Set the EFFECT parameter Touch the or button, and set the value within the range between 1 to 20

  • Canon MLT (F), – 1 – 1. Overview 1.1 About MLT (F) NOTE: MLT (F) is supported by CXDI System Software Version 4.3 or later. The CXDI Image Processing Software MLT (F) (called “MLT (F)” in this manual) is designed to extend the image processing functions provided with the CXDI series of Canon dig- ital radiography system (called “CXDI” in this manual). By installing MLT (F) on the Control PC, the advanced image processing features of MLT (F) are brought into full scope both in the Edit Exposure Mode and QA Mode. The following examples show the QA Mode screens of CXDI System Software version 6.3. Standard QA Mode Screen (DEP Tab) QA Mode Screen Extend

  • Canon MLT (F), 3.QA Mode Settings – 20 – 7 Select the DENSITY BASE parameter Touch the desired Density Base button. The parameter is selected for the Density Base, and the DENSITY BASE window is closed. 8 Set the settings valid, and close the MORE window Touch [OK]. Representation of the enhancement degree on a line graph After the Density Base is set, a line graph is displayed at the top-right of the screen to illustrate the comparisons with density and the degree of enhancement. The horizontal axis represents density, and the vertical axis represents the degree of enhancement in each density, indi

  • Canon MLT (F), Before using the instrument, be sure to read this manual thoroughly. Also, read the manuals of other instruments in this system. Keep the manual where it is easily accessible. User’s Manual MLT (F) CXDI Image Processing Software

  • Canon MLT (F), Contents 1. Overview ......................................................................................1 1.1 About MLT (F) .......................................................................................1 1.2 Available Functions of MLT (F) .............................................................2 2. Edit Exposure Mode Settings ......................................................3 2.1 Procedures to Edit Exposure Mode .......................................................3 2.2 Setting DWT ENHANCE. Tab ...............................................................7 2.3 Set

  • CANON INC. Medical Equipment Group 30-2, Shimomaruko 3-chome, Ohta-ku, Tokyo, Japan Telephone: (81)-3-3758-2111 CANON U.S.A., INC. CANON MEDICAL SYSTEMS 15955 Alton Parkway, Irvine, CA 92618-3616, U.S.A. Telephone: (1)-949-753-4160 CANON EUROPA N.V. Medical Products Division Bovenkerkerweg 59-61, 1185 XB Amstelveen, The Netherlands Telephone: (31)-20-545-8926 PUB. L-IE-4

  • Canon MLT (F), – 29 – 4.QA Parameters 9 Suppress Grid Processing One of the following parameters is displayed: Z0 (No grid stripe is detected), Z1 (Grid stripes are suppressed), Z* (Processing is not determined yet) If the Grid Reduction Processing is not effective, nothing is displayed. 10 High-Density Clipping Processing (HIGH IN. CLIPPING) One of the following parameters is displayed: C0 (Clipping is not performed), C1 (Clipping is performed), C* (Processing is not determined yet) If the High-Density Clipping Processing is not effective, nothing is displayed. 11 Dose-Depend Processing (D. DEPEND MTF IMP) One of the fo

  • Canon MLT (F), 1.Overview – 2 – 1.2 Available Functions of MLT (F) This manual describes the operating procedures of the following three image processing func- tions that are available with MLT (F). For details and information on other image processing functions, please refer to Operation Manual and Setup Guide. DWT*1 Edge Enhancement (→ P.7) The DWT ENHANCE. tab provides the function to accentuate edge details of the expo- sure image by specifying the three parameters; the degree of enhancement (EFFECT), type of enhancement (FREQUENCY BASE), and type of density dependent of the image (DENSITY BASE). DWT DEP*2 (�

Related Products and Documents (Camera Accessories):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 KitchenAid KFP0718 Manual  kitchenaid/kfp0718-CG8.pdf 26 Mar 2024 56
2 Samsung MG1480STB Owner's manual samsung/mg1480stb-J7Z.pdf 23 Mar 2023 28 0.95 Mb
3 Big clinker 10500 20 In. Owner's manual big-clinker/10500-20-in-YL9.pdf 12 Aug 2023 8
4 Klark Teknik 76-KT Quick start manual klark-teknik/76-kt-TL5.pdf 27 Jan 2023 11
5 HP Vectra XA 6/xxx Operation & user’s manual hp/vectra-xa-6-xxx-E28.pdf 11 Feb 2024 102
6 Turbosound TXP-151 Datasheet turbosound/txp-151-125.pdf 15 Aug 2023 7 0.71 Mb

Similar Resources:

  • Voltacon

    Li2021 48V50Ah LFP

    (30 pages)
    VOLTACON Li2021 BATTERY 2.4KWH 48V User ManualVoltacon Li2021 2.4KWH 48V Battery User Manual Dear customer, This is your Li2021 48V50Ah LFP battery battery for home energy storage system. We provide safe, well-designed and high-performance standard LFP battery pack for you. The battery pack is compact, easy to install, free of maintenance and used as the bui …
  • Sony

    SPK-LA

    (4 pages)
    SERVICE MANUALSPK-LASPORTS PACKUS ModelCanadian ModelAEP ModelChinese ModelSPK-LAVer. 1.1 2008.11MAIN FEATURESPECIFICATIONSMaterialPlastic (PC, ABS), stainless steel, glassWater-resistanceWaterproof gasket, bucklePressure-resistanceTo a depth of up to 3 m (9.8 feet) underwaterSwitches that can be externally operatedPower, Mode, Shutter, Zoom, Flash, Macro, …
  • Philips

    R6B4A210

    (2 pages)
    Enjoy your music longerwith these 2100mAh AA rechargeable accusIdeal for all your digital devices. These high capacity AA accus do not need draining before recharging, simply top them up whenever it is convenient for you. What's more you can recharge them up to a thousand times.Top Performance• NiMH technology for recharging multiple times• The batt …
  • BAFANG

    BT C01. UC Series

    (12 pages)
    1 BF-UM-C-BT C01-EN October 2019USER MANUAL FOR BATTERY8.1 Instructions 28.1.1 Battery 28.1.1.1 Safety Instructions 28.1.1.2 Battery Storage 38.1.1.3 Battery Wear 38.1.1.4 Pedelec Riding Distance 38.1.2 Charger 48.1.2.1 Battery charger Instructions 48.2 Operation 58.2.1 Installing the Battery 58.2.2 Removing the Battery 58.2.3 Charging the …
  • MIOPS

    MIOPSMobile Dongle Kit

    (2 pages)
    !!QUICK!START!GUIDE!!MIOPSMOBILE!DONGLE!KIT!miops.com0000Application0Settings0You!can!open!the!application!settings,!by!touching!the!gear!icon !at!the !right!top !corner!of!the!screen.!You!can!various!settings!of!the!app!using!this!screen.!The!chan ges!to !the!settin gs!will!be!saved!automatically.!The!first!setting!is!the!“Pulse!Length”.!MIOPSMOBILE!gen …
  • MOVOFILMS

    MF-DCC

    (4 pages)
    DSLR Camera Cage I N S T R U C T I O N M A N U A L MF-DC C © Copyright Flyboyfilms NV. All rights Reserved Green Hill I Hoge Wei 16 I 1930 Zaventem I Belgium [email protected] I www.movofilms.be …

Comments, Questions and Opinions: