  • Carrier INFINITY 1620, GAPAB Infinityt Air Purifier for F an Coils Sizes 1620, 2020 and 2420 Installation Instructions NOTE: Read the entire instruction manual before starting the install. TABLE OF CONTENTS PAGE INTRODUCTION 1.................................... HOW IT WORKS 1.................................... SAFETY CONSIDERATIONS 1.......................... APPLICATION CONSIDERATIONS 2.................... INSTALLATION 3 --6................................... START--UP AND OPERATION 7......................... MAINTENANCE 7 -- 8................................. TROUBLESHOOTING 9................................ SPE

  • Carrier INFINITY 1620, 2 PERSONAL INJURY HAZARD Failure to follow this caution may result in personal injury. Ozone in concentrations above 0.05 PPM may be hazardous to health. Des concentrations d’ozone superieures a 0.05 PPM peuvent etre nocives pour la sante. CAUTION ! APPLICATION CONSIDERATIONS The Infinityt Air Purifier is designed for use in the return air duct of a forced air heating, cooling, and ventilation system. Models GAPABXCC1620, GAPABXCC2020 and GAPABXCC2420 are specifically designed for use in systems with a fan coil. Air Conditioning The Infinity

  • Carrier INFINITY 1620, 3 INSTALLATION Step 1 —Check Infinityt Air Purifier Components CUT HAZARD Failure to follow this caution may result in personal injury. Sheet metal parts may have sharp edges or burrs. Use care and wear appropriate protective clothing and gloves when handling parts. CAUTION ! a. Carefully remove all items from the box. Step 2 —Identify Mounting Location a. Identify a mounting orientation for the Infinityt Air Pu- rifier in the return air duct (see Fig. 4). b. Ensure airflow direction through the Infinityt Air Purifi- er matches the arrows on the face of the air purifier car- tridge. The Infini

  • 4 Step 3 —Mount Cabinet a. Turn off power to the heating and cooling system. b. Remove the existing fan coil filter and discard. Excessive system static pressure may result if the Infinityt Air Puri- fier is used with other filtration devices. c. Remove the air purifier cartridge and enhancement mod- ule from the Infinityt Air Purifier cabinet. d. Position the cabinet between the fan coil an

  • Carrier INFINITY 1620, 5 Step 4 —Wiring a. Ensure power has been removed from the heating and cooling system. b. Turn the Infinityt Air Purifier power switch off. c. Connect the power cord and the flow sensor cord to the power supply connector and the flow sensor connector (see Fig. 7 and Fig. 8). NOTE: The power cord can be routed through the opposite side of the cabinet. Zip ties have been enclosed to secure the power cord to the side of the power supply. NOTE: Cable connector and block--off plates will need to be re

  • Carrier INFINITY 1620, 6 TO FAN COIL FIELD POWER CONNECTION FUSED POWER CONNECTOR LEADS FROM INSTALLATION COMPONENTS (IN BAG ATTACHED TO POWER CORD) AIR PURIFIER POWER CORD TO FAN COIL FIELD POWER CONNECTION TO L2 FIELD POWER SUPPLY TO L1 FIELD POWER SUPPLY 5 AMP IN-LINE FUSES GROUND: ATTACH TO FAN COIL GROUND (CHASSIS) CABLE CONNECTOR TO SECURE POWER CORD TO FAN COIL CABINET A06515 Fig. 10 --- Fan Coil Chassis Ground A ir Flow Sensor 1) Slide flow sensor tabs into support bracket 2) Rotate flow sensor and clip into bracket A06412 Fig. 11 --- Flow Sensor Install GAPAB

  • Carrier INFINITY 1620, 7 START--UP AND OPERATION Step 1 —Checking Air Purifier Operation ELECTRICAL SHOCK AND HIGH VOLTAGE HAZARD Failure to follow this warning could result in personal injury or death. Before installing or servicing system, always turn off main power to system. There may be more than one (1) disconnect switch. ! WARNING a. Attach the Infinityt Air Purifier door to the cabinet. A magnet in the door (see Fig. 8) is used to activate a safety switch in the power supply when the door is installed. The power supply will not energize the air purifier unless the safety switch is activated. b. Turn the HVAC system power on and adjust the thermo- stat or Infinityt System Control to activate the system

  • 8 At the time of air purifier cartridge replacement, if a powdery residue is notic ed on the tips o f the points in the ionization array, proceed to clean them by completing the following steps: Step 1 —Turn heating and cooling system power off. ELECTRICAL SHOCK AND HIGH VOLTAGE HAZARD Failure to follow this warning could result in personal injury or death. Before in

  • Carrier INFINITY 1620, 9 TROUBLESHOOTING SAFETY HAZARD Failure to follow t his caution may result in personal injury or equipment damage. The following instructions are for use by qualified personnel only. CAUTION ! ELECTRICAL SHOCK AND HIGH VOLTAGE HAZARD Failure to follow this warning could result in personal injury or death. The following procedures will expose electrical components. Disconnect power between checks and proceed carefully. ! WARNING The Infinityt Air Purifier is equipped with a power indicator light

  • Carrier INFINITY 1620, 10 SPECIFICATIONS AND DIMENSIONS Table 1—Specifications and Dimensions Specifications GAPABXCC1620 GAPABXCC2020 GAPABXCC2420 Color Taupe Metallic Taupe Metallic Taupe Metallic Cabinet Material 20 Ga. Powder Coated Steel 20 Ga. Powder Coated Steel 20 Ga. Powder Coated Steel Electrical 208/230v/60Hz 208/230v/60Hz 208/230v/60Hz Maximum Airflow (CFM) 1350 1800 2000 Efficiency Equivalent to MERV 15 Equivalent to MERV 15 Equivalent to MERV 15 Replacement Cartridge GAPCCCAR1620 GAPCCCAR2020 GAPCCCAR2420 Initial Pressure Drop (in w.c.) (at maximum airflow) .22 .25 .22 Dimensions GAPABXCC1620 GAP

  • Carrier INFINITY 1620, 11 WARRANTY FOR SERVICE OR REPAIR, FOLLOW THESE STEPS IN ORDER: FIRST: Contact the installer. You may find their name on the product or i n your Homeowner’s Packet. If the installer’s name is not known, call your builder or home retailer if yours is a new residence. SECOND: Contact the nearest distributor. (See telephone yellow pages.) THIRD: Contact: CARRIER CORPORATION Consumer Relations P.O. Box 4808 Syracuse, New York 13221 Telephone: 1--800--CARRIER (227--7437) 1--315--432--7885 (Canada) Model No. ____________________________________________ Unit Serial No. ______________________________________ Date of Installation ______

  • Carrier INFINITY 1620, 12 Copyright 2007 Carrier Corp. S 7310 W. Morris St. S Indianapolis, IN 46231 Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. Catalog No: GAPAB--2SI Replaces: GAPAB--1SI Printed in U.S.A. Edition Date: 02/07 GAPAB

Related Products and Documents (Air Cleaner):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 LG 30FZ1DC Specification sheet lg/30fz1dc-E7M.pdf 06 Jun 2023 2
2 Pure Digital Contour Air 200i Owner's manual pure-digital/contour-air-200i-E49.pdf 03 Oct 2023 28
3 Smeg 142396 User manual manual smeg/142396-2I6.pdf 10 Oct 2022 20 1.43 Mb
4 NEFF B1691N0GB Introduction neff/b1691n0gb-175.pdf 29 Apr 2023 1
5 Sylvania SCR1384 Specification sheet sylvania/scr1384-52A.pdf 16 Sep 2022 1 0.31 Mb
6 Breckwell SP1002 Owner's manual breckwell/sp1002-684.pdf 16 Oct 2023 28 2.02 Mb

Similar Resources:

  • Blaupunkt

    AP 1.1

    (50 pages)
    Enjoy it.DE - BedienungsanleitungEN - Operating InstructionsPL - Instrukcja obsługiDA - BrugsanvisningES - Operación manualFR - Mode d‘emploiIT - Manuale operativoNL - HandleidingAIR PURIFIERAIRPURE AP 1.1 …
  • Honeywell

    16180 SERIES

    (6 pages)
    OWNER’S GUIDE PLUG & CLEANAIR CLEANER WITH NIGHT-LIGHTMODEL 16180 SERIESM20197OffOnJANHIP3DJH7KXUVGD\6HSWHPEHU30 …
  • Trion

    HE Plus 1400

    (2 pages)
    Residential & Light Commercial HVACHE Plus1400/2000Electronic Whole-House Air CleanersPERFORMANCE:Rated air flow up to 2000 cfmTested in accordance with ANSI/ASHRAE 52.1-1992Aluminum mesh pre-filter traps large particles such as dirt, lint and pet hairFEATURES:The strongest, most reliable power supply and the sturdiest cell in the industry – recognized …
  • Hunter

    30526

    (16 pages)
    www.hunterfan.com41599-01 05/05/2006 © 2006 Hunter Fan CompanyReplacement Filter InformationPre-Filter309013090130901Model305263052720528 Model 30526HEPAtech®Air PurifierHEPAtech Filter309313093130931®41599-01_05.05.06.pmd 5/5/06, 9:05 AM1 …
  • Edelbrock

    1207*

    (3 pages)
    1 of 3Edelbrock Air CleanerBrochure #63-0019©2014 Edelbrock LLC Rev. 2/13/14 QT/mcEDELBROCK AIR CLEANER Part Numbers: 1207, 1208, 1209, 1221, 1222, 1235, 1236, 4207, 4208, 4210, 4220- 4237, 4239, 41613, 42203INSTALLATION INSTRUCTIONSPlease study these instructions carefully before installing your new Air Cleaner Assemblies. If you have any questions, do no …
  • Welcare

    PUREAIR WPA300

    (20 pages)
    MODEL: WPA300Instruction Manual & Warranty InformationRead Instructions Carefully Before UseWPA300_Instruction-Manual_A5-working.indd 1WPA300_Instruction-Manual_A5-working.indd 1 12/8/21 1:26 pm12/8/21 1:26 pm …

Comments, Questions and Opinions: