Manualios.com

Carrier Access Network Device Axxius 800 Operation & User’s Manual

  • Network Device Axxius 800 Network Card
  • manvrjfUnLjHo
  • Operation & User’s Manual
  • PDF / Adobe Acrobat Reader
  • 568

Carrier Access Network Device Axxius 800 Manual Online:

3.9, 2017 votes
Carrier Access Network Device Axxius 800 User Manual
Carrier Access Network Device Axxius 800 User Guide
Carrier Access Network Device Axxius 800 Online Manual

Text of Carrier Access Network Device Axxius 800 User Guide:

  • Axxius 800 - Release 2.2 5-25 CLI Commands add {src-ip-addr/bits} The destination IP address and number of significant bits. The address "0.0.0.0/0" matches any address. src-ip-addr Enter the IP Address of the remote device or network that this rule will affect. If you enter the address of a remote device, this rule will affect only the session e

  • Carrier Access Network Device Axxius 800, 5-254 Axxius 800 - Release 2.2 CLI Commands status status (router-trunk) Use the status (router-trunk) command to display the current status information for the specified Trunk on the Router card. Syntax: status {rtr_trunk-addr) Example: status 3:1:1-4 > status 3:1:1-4 SLOT 3: Status for TSR 1 Trunk 1: Link Alarm: NO SLOT 3: Status for TSR 1 Trunk 2: Link Alarm: NO SLOT 3: Status for TSR 1 Trunk 3: Link Alarm: NO SLOT 3: Status for TSR 1 Trunk 4: Link Alarm: NO

  • Carrier Access Network Device Axxius 800, 5-234 Axxius 800 - Release 2.2 CLI Commands status status (ds1) performance history Use the status (ds1) performance history command to display performance statistics for the current 15 minute interval and all previous 15 minute intervals (up to a total of 96) of a DS1. Syntax: status {ds1-addr} performance history Example: status a:1 performance history SLOT A: Performance Statistics for DS1 1: U A S SES ES SEFS LES CSS BES D M L C V P C V curr. interval: 288 0 0 0 0 0 0 0 0 0 prev. intvl 1: 900 0 0 0 0 0 0 0 0 0 pr

  • Carrier Access Network Device Axxius 800, Axxius 800 - Release 2.2 Glossary - 19 Glossary V.90 V.90 The standard for full-duplex modems sending and receiving data across phone lines at up to 56,600 bps, approved by the International Telecommunication Union (ITU) in February, 1998. VC MUX Virtual Channel Multiplexer. Voice Over IP (VoIP) An emerging technology that is, voice delivered using the Internet Protocol, is a term used in IP telephony for a set of facilities for managing the delivery of voice information using the Internet Protocol (IP). In general, this means se

  • Carrier Access Network Device Axxius 800, Axxius 800 - Release 2.2 xxv Table of Contents Power Consumption . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-6 Environment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-6 Physical. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-6 Card Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-7 CLI Commands. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-7 Basic Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

  • Carrier Access Network Device Axxius 800, Axxius 800 - Release 2.2 C-7 Loopback Tests Overview Overview A loopback test is a diagnostic procedure in which a signal is transmitted and returned to the sending device after passing through all or a portion of a network or circuit. The returned signal is compared with the transmitted signal in order to evaluate the integrity of the equipment or transmission path. DS1 Loopbacks Note: T1 LEDs flash green during any DS1 loopback. DS1 Line Loop Loops at DS1 (at framer), signal not reframed. Have DS1 vendor check for framing/ errors. Enable Line Loopback > se

  • Carrier Access Network Device Axxius 800, 5-230 Axxius 800 - Release 2.2 CLI Commands status status (bri) performance history Use the status (bri) performance history command to display the performance statistics for the current 1 hour interval and all previous 1 hour intervals for the ISDN BRI card. Syntax: status {bri-addr} performance history Example: status 5:1 performance history SLOT 5: Performance Statistics for BRI Port 1: HES HSES BE DES DSES current interval 0 0 0 0 0 prev. interval 1 0

  • Carrier Access Network Device Axxius 800, 5-228 Axxius 800 - Release 2.2 CLI Commands status status (bri) Use the status (bri) command to display the status information for the ISDN BRI card. Syntax: status {bri-addr} Example: status 3:1 The example displays status of port 1 (BRI) on slot 3. > status 3:1 SLOT 3: Status for BRI Port 1: Loopback: NONE Corrupt CRC: NONE {bri-addr} The BRI address, in the form {slot:port}. slot The slot number (1-8) that contains the BRI card port Port number, range or all

  • Carrier Access Network Device Axxius 800, 4-24 Axxius 800 - Release 2.2 Configuration Setup of DS0 Management Channel 9. Select the following on this screen: At the Select WAN Port Number: < None>, scroll from None to 1 (which is the remote Axxius1). Set DLCI to 16. 10. Select [ESC] to exit the Trunk Port configuration window. 11. Select [ESC] to exit and <Yes> to save changes.

  • Carrier Access Network Device Axxius 800, Axxius 800 - Release 2.2 5-221 CLI Commands show show time The show time command displays the system time, in 24 hour hh:mm:ss format. Syntax: show time Example: show time > show time time: 00:22:51 show users The show users command displays a list of all users and their settings, and if they are logged on at the time (0=not logged on, 1=logged on). Syntax: show users Example: > show users User Level Last Login Logged In ---- ----- ---------- --------- * jack 1 00:00:13 01/01/1999 1 * indicates self

  • 15-2 Axxius 800 - Release 2.2 Terminal Server Router Card Overview Overview The Quad-Port Terminal Server Router (TSR) card combines the performance and expand ability of a selectable four-port RS-232 and 10/100Base-TX Ethernet switch with dedicated routing functionality in a low-cost solution to help wireless service providers remotely manage cell site LMU and switching devices, and deliver r

  • Carrier Access Network Device Axxius 800, Axxius 800 - Release 2.2 5-207 CLI Commands show {rtr_lan-addr} The Router address is in the form {slot:port} or {slot "profile-name"} [address|custom|protocol|all] This setting will display the defined filter types of the specified filters. slot The slot number (1-8) that contains the Router card. port Port number of the Router. "profile-name" The profile name for the Router interface. Name must be enclosed in quotes, with a maximum length of 11 characters. address Display Address filters only. cu

  • Carrier Access Network Device Axxius 800, 5-172 Axxius 800 - Release 2.2 CLI Commands set set (v54) Use the set (v54) command to setup V.54 Loopback Test Parameters. The command specifies the range of channels within that card, and the setting to apply. Syntax: set {v54-addr} v54 {setting} [off|on] [n] [nnn] Example: set 6:1 v54 equipment clear The example will clear the loop test counter on the V.54 card in slot 6, port 1. {v54-addr} In the form of {slot:port}. {setting} slot Slot number (1-8) of the Axxius chassis where the V.35/54 card is located port Port number or range. equipment Set the V.54 Equipment (Tx) parameters: address Syntax: set {v54-addr} v54 equipment address {nnn} Set V.54 loop test address [nnn] Set

  • Carrier Access Network Device Axxius 800, 15-4 Axxius 800 - Release 2.2 Terminal Server Router Card Technical Specifications Technical Specifications Controller Software Required l Release 1.0 or higher is required for the TSR service card l Release 2.0 or higher to support a TSR Service card with TBOS l TSR release 1.2 or higher to support all features listed in this chapter Management l CLI driven via RS-232 or Ethernet l Menu-driven via RS-232 or Ethernet, see the Terminal Server Router User Manual for information on the Menu-driven software l SNMP l Ping, Trace Route l Ethernet management port l IP management DS0 bearer channel l Code download via TFTP l Conf

  • Carrier Access Network Device Axxius 800, 1-8 Axxius 800 - Release 2.2 Base Platform Technical Specifications Alarm Connectors The alarm contact outputs are per Telcordia definitions for visible and audible. They operate per the spec with the exception that the audible outputs can be disabled with the ACO button. l The alarm output contacts are designed for use at 48V nominal with a current draw of 0.5A maximum. l The alarm inputs are dry contact with a current capacity of 10mA. Network Standards l ANSI/TIA - T1.403 ESF FDL Management l Craft Interface - front access from RS-232 (D

  • Glossary - 12 Axxius 800 - Release 2.2 Glossary Line Coding Violation (LCV) Line Coding Violation (LCV) This parameter is a count of both BPVs and EXZs occurring over the accumulation period. An EXZ increments the LCV by one regardless of the length of the zero string. Line Errored Seconds (LES) A Line Errored Second is a second in which one or more CVs occurred OR one or more LOS de

  • Carrier Access Network Device Axxius 800, 5-46 Axxius 800 - Release 2.2 CLI Commands delete delete (router) snmp trap Use the delete (router) snmp trap command to delete a trap destination from the specified Router card. Syntax: delete {rtr_card-addr} snmp trap {"community-name"} {ip-addr} Example: delete 2 snmp trap "commune" 192.168.100.245 The example will delete the previously added SNMP community named "commune" from the Router in slot 2. {rtr_card-addr} The slot number (1-8) that contains the Router card. {"community-name"} The name of an existing community. This name must be enclosed in quotes, with a maximum of 12 characters. {ip-addr} The IP address of the

  • Carrier Access Network Device Axxius 800, 3-12 Axxius 800 - Release 2.2 Electrical Installation and Cabling Chassis Connections Slot (1-8) Wire-Wrap Connectors The Axxius 800 provides wire-wrap connectors for each slot (1-8) of the unit. Pinouts are clearly labeled with the pins. CAUTION! DISCONNECT FROM NETWORK BEFORE INSTALLING WIRE-WRAP CONNECTIONS. Wire-Wrap Connectors

  • Carrier Access Network Device Axxius 800, Axxius 800 - Release 2.2 5-225 CLI Commands status status (adpcm) Use the status (adpcm) command to display the status information for the ADPCM card. Syntax: status {adpcm-addr} Example: status 6:1 > status 6:1 SLOT 6: Status for DS1 1: Receive: Loss of Signal Transmit: RAI/Yellow Alarm Loopback: OFF {adpcm-addr} The ADPCM address is in the form {slot|slot:port}. Where {slot} displays information for all ports on the card, {slot:port} for only the defined port. slot Slot number (1-8) where the ADPCM card is located port Port number. range 1-4.

  • Carrier Access Network Device Axxius 800, CHAPTER OCU-DP Card In this Chapter n Overview n Features n Technical Specifications n Card Configuration - CLI Commands - Basic Setup n LEDs n Jumper Settings n Alarms n Line Rates/Line Lengths n Connector Pinouts - DDS RJ-48S - Wire-Wrap Pinout 4 Wire Services

  • Carrier Access Network Device Axxius 800, Axxius 800 - Release 2.2 15-17 Terminal Server Router Card Connector Pinout Connector Pinout 10Base-T Ethernet The pinout for the RJ-48C (female) connectors on the front of the card are as follows: RS-232 If the card is set to use the RS-232 connector (with jumpers) use the above RS-232 pinouts. There is a RS-232 to DB-9 converter cable available, P/N 005-0106. The pinout is as follows: Pin Name Description 1 Receive + Receive from network 2 Receive - Receive from network 3 Transmit + Transmit to network 4 - 5 N/C Not connected 6 Transmit - Transm

Related Products and Documents (Network Card):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Samsung UN40D6400UF Service manual samsung/un40d6400uf-LUL.pdf 18 Dec 2023 87
2 Planet XRT-401F Operation & user’s manual planet/xrt-401f-K92.pdf 02 Sep 2023 79
3 Creative CD-R Operation & user’s manual creative/cd-r-83J.pdf 16 Sep 2022 45
4 Toshiba 32E200U Owner's manual toshiba/32e200u-8AI.pdf 22 Dec 2023 62 15.03 Mb
5 Clarity CE125 Operation & user’s manual clarity/ce125-GM4.pdf 28 Apr 2023 3 0.24 Mb
6 Crown AMB-5 Operation & user’s manual crown/amb-5-44T.pdf 12 Feb 2023 222 1.44 Mb

Similar Resources:

  • TDK

    TSL Series TSL1112

    (2 pages)
    (1/2)003-02 / 20080702 / e532_tsl1112.fm• All specifications are subject to change without notice.Radial Lead Inductors(Coils)For Power LineTSL Series TSL1112 FEATURES• The TSL series feature low DC resistance and high current han-dling capacities, making them ideal for power supply line appli-cations.• These parts are manufactured to a high degree of …
  • Black Box

    LE7005A-UTP-R2

    (2 pages)
    Simultaneous data/fax modem and Ethernet accessfor your notebook computer.Platform-independent—supports all PCMCIA 2.1,Type II-compliant PCs.The Fax/Modem installs as a COM port, runs anextended AT command set, and works with allmajor DOS and Windows®fax/modem software.Supports K56flex™, ITU V.34, V.32 bis, V.32, V.22 bis, V.22A/B, V.23, V.21 and Bell 2 …
  • ADTRAN

    Total Access 1100F

    (2 pages)
    Product Features Sealed GR-487 compliant unit Dual Optical GigE Networkfeeds  Networks with Total Access1124 or 1148 DSLAM for fiberdeployment 7 Gbps switching capacity Easily configurable for bothelectrical and optical expan-sion interfaces Priority Queuing (802.1p)  Integrated Security Support Replication of Multicast T …
  • Delta Electronics

    USB/RS485 Communication Interface VFD-USB01

    (2 pages)
    5011661301-TUS120070718 VFD-USB01 USB/RS485 Communication InterfaceInstruction Sheet  Please thoroughly read this instruction sheet before installation and putting it into use.  The content of this instruction sheet and the driver file may be revised without prior notice. Please consult our distributors or download the most updated instruction/driver …
  • Tripp Lite

    48U SmartRack Premium Enclosure SR48UB

    (4 pages)
    Tripp Lite1111 West 35th StreetChicago, IL 60609 USATelephone: +(773) 869 1234E-mail: [email protected] #: SR48UB48U SmartRack Premium Enclosure (includes doors and side panels) Highlights48U SmartRack enclosure with doors and side panels4 interior vertical posts with unthreaded square hole openingsStandard 24" width for optimizing floor spa …
  • Cisco

    ATA-186

    (228 pages)
    Corporate HeadquartersCisco Systems, Inc.170 West Tasman DriveSan Jose, CA 95134-1706 USAhttp://www.cisco.comTel: 408 526-4000800 553-NETS (6387)Fax: 408 526-4100Cisco ATA 186 and Cisco ATA 188Analog Telephone Adaptor Administrator’s Guide (H.323)Customer Order Number: OL-4008-01 …

Comments, Questions and Opinions: