Cisco SFE2000P Installation And Configuration Manual
|
Cisco SFE2000P, 6-13 Cisco SCE 2000 4xGBE Installation and Configuration Guide OL-7824-06 Chapter 6 Cabling the Line Ports and Completing the Installation Information About Cascaded Systems • Connection mode — Redundancy is achieved by cascading two SCE platforms. Therefore the connection mode for both SCE platforms may be either: – Inline-cascade – Receive-only-cascade • Physically-connected-links — For each of the cascaded SCE platforms, this parameter defines the number of the link (Link 0 or Link 1) connected to this SCE platform. • Priority
Cisco SFE2000P, 4-18 Cisco SCE 2000 4xGBE Installation and Configuration Guide OL-7824-06 Chapter 4 Installation and Maintenance Removing and Replacing a Power Supply Unit Note Make sure that the power supply unit is switched off before replacing it (NO hot-swap). Note that one AC-input power supply can be running when the other power supply is being removed or replaced. • What to Do Next SUMMARY STEPS 1. Place the on/off switch on the AC-input power supply in the OFF position. 2. Observe that the corresponding Power LED on the front panel turns off. 3. Remo
Cisco SFE2000P, 4-20 Cisco SCE 2000 4xGBE Installation and Configuration Guide OL-7824-06 Chapter 4 Installation and Maintenance Reconnecting the Power SUMMARY STEPS 1. Grasp the power supply unit handle with one hand and place your other hand underneath the power supply for support. 2. Fit the groove in the side of the new power supply module into the guide in the chassis. 3. Gently, but firmly, slide the module into the chassis until its faceplate is flush with the chassis rear panel. 4. Seat the power supply in the SCE 2000 platform by tightening the ca
Cisco SFE2000P, 5-3 Cisco SCE 2000 4xGBE Installation and Configuration Guide OL-7824-06 Chapter 5 Connecting the Management Interfaces and Performing Initial System Configuration Initial System Configuration Initial System Configuration Upon initial connection to the local terminal, as described above, the system configuration wizard automatically runs to guide the user through the entire setup process. The wizard prompts for all necessary parameters, displaying default values, where applicable. You may accept the default values or define ot
Cisco SFE2000P, 7-6 Cisco SCE 2000 4xGBE Installation and Configuration Guide OL-7824-06 Chapter 7 Basic SCE 2000 Platform Operations Managing SCE 2000 Configurations SUMMARY STEPS 1. At the SCE 2000# prompt, type show running-configto view the running configuration. 2. Check the displayed configuration to make sure that it is set the way you want. If not, make the changes you want before saving. 3. Type copy running-config startup-config. DETAILED STEPS Step 1 At the SCE 2000# prompt, type show running-configto view the running configuration. The running configu
7-7 Cisco SCE 2000 4xGBE Installation and Configuration Guide OL-7824-06 Chapter 7 Basic SCE 2000 Platform Operations Managing SCE 2000 Configurations The following example illustrates how to remove all DNS settings from the running configuration. SCE 2000(config)#no ip name-serverSCE 2000(config)# How to Recover a Previous Configuration When you save a new configu
Cisco SFE2000P, 8-10 Cisco SCE 2000 4xGBE Installation and Configuration Guide OL-7824-06 Chapter 8 Troubleshooting Troubleshooting Overview Management link up: • Mng LINK LED is lit • pingto management interface fails CLI commands • show ip route • show ip default-gateway One of the following configurations may be wrong: • IP address / subnet mask • IP default gateway See Connecting the Management Interfaces and Performing Initial System Configuration Refer to " IP Configuration " in the Cisco Service Control Engine (SCE) Software Configuration Guide. CLI command show access-lists An ACL may be assigned that denies entry. See Connecting
Cisco SFE2000P, 5-27 Cisco SCE 2000 4xGBE Installation and Configuration Guide OL-7824-06 Chapter 5 Connecting the Management Interfaces and Performing Initial System Configuration Connecting the Management Interface DETAILED STEPS Step 1 After you connect the cable to the appropriate Mng port and to your network, check the relevant Mng port LEDS. There are two Mng LEDs — Link/Active, and 10/100/1000 (refer to Front Panel). At this point, check that the Link/Active LED is green. The state of the 10/100/1000 LED will depend on the Ethernet network settings. Green indic
Cisco SFE2000P, CHAPTER 5-1 Cisco SCE 2000 4xGBE Installation and Configuration Guide OL-7824-06 5 Connecting the Management Interfaces and Performing Initial System Configuration This chapter explains how to connect the SCE 2000 platform to a local console and perform the initial system configuration via the setup wizard that runs automatically. Additionally, this chapter contains instructions for cabling the Fast Ethernet Management interfaces. Note When installing a cascaded system, it is extremely important
Cisco SFE2000P, 6-15 Cisco SCE 2000 4xGBE Installation and Configuration Guide OL-7824-06 Chapter 6 Cabling the Line Ports and Completing the Installation How to Load and Activate a Service Control Application How to View the Current Connection Mode Step 1 From the SCE 2000# prompt, type show interfacelinecard 0 connection-modeand press Enter. How to View the Current Link Mode Step 1 From the SCE 2000# prompt, type show interface linecard 0 link modeand press Enter. How to View the Current Link Mappings Step 1 From the SCE 2000# prompt, type show interfacelinecard 0 physically-connected-linksand press Enter. How to Load and Activate a Servic
Cisco SFE2000P, 5-12 Cisco SCE 2000 4xGBE Installation and Configuration Guide OL-7824-06 Chapter 5 Connecting the Management Interfaces and Performing Initial System Configuration Initial System Configuration EXAMPLE: Following is a sample DNS configuration dialog. The default domain name is pcube.com, and the IP address of the Domain Name Server is 10.1.1.230. Would you like to enter the DNS configuration menu? [no]: yEnable IP DNS-based hostname translation? [yes]: Enter default domain name []: pcube.comEnter Primary DNS IP address: 10.1.1.230Would you l
Cisco SFE2000P, 2-8 Cisco SCE 2000 4xGBE Installation and Configuration Guide OL-7824-06 Chapter 2 Introduction to the SCE Platform Information About The SCE Platform Network interface cables and devices connected System power turned on System boot complete (SYSTEM–UP LED is on) Correct hardware configuration displayed after system banner appears Table 2-5 SCE 2000 Installation Checklist Task Verified By Date
Cisco SFE2000P, 6-14 Cisco SCE 2000 4xGBE Installation and Configuration Guide OL-7824-06 Chapter 6 Cabling the Line Ports and Completing the Installation Information About Cascaded Systems • cutoff • sniffing Normally, the link mode is selected by the SCE platform software according to the configured connection-mode. However, the link-modecommand can be used to enforce a specific desired mode. This may be useful when debugging the network, or in cases where we would like the SCE platform just to forward the traffic. (Note that this is only relevant to inline topologies even though the configuration is available also when in receive-only mode.) The following link mode
Cisco SFE2000P, 4-23 Cisco SCE 2000 4xGBE Installation and Configuration Guide OL-7824-06 Chapter 4 Installation and Maintenance Fan Module Overview Figure 4-17 Connecting the DC Power Note The color coding of the DC-input power supply leads depends on the color coding of the DC power source at your site. Make certain the lead color coding you choose for the DC-input power supply matches lead color coding used at the DC power source. Note Use 12 AWG (2.5 mm) copper wire only with hex or loop connectors. Ring terminals must be UL approved and suitable for 12 AWG wire. Step 4 Using the number 2 Phillips screwdriver, securely fasten the pro
3-8 Cisco SCE 2000 4xGBE Installation and Configuration Guide OL-7824-06 Chapter 3 Information About Topology Information About Topology Considerations Figure 3-4 SCE Platform Dual Link Receive-Only Topology Note When implementing receive-only topologies with a switch, the switch must support SPAN functionality that includes separation between ingress and egress tra
Cisco SFE2000P, 3-3 Cisco SCE 2000 4xGBE Installation and Configuration Guide OL-7824-06 Chapter 3 Information About Topology Information About Topology Considerations Note that when the SCE 2000 is connected to the network through an optical splitter, a failure of the SCE 2000 does not affect the traffic flow, as the traffic continues to flow through the optical splitter. • Bypass Mechanism • Maintaining the Network Links vs Maintaining SCE 2000 Platform Functionality Bypass Mechanism The SCE 2000 includes a Network Interface Card with a bypass mechanism that is ena
8-9 Cisco SCE 2000 4xGBE Installation and Configuration Guide OL-7824-06 Chapter 8 Troubleshooting Troubleshooting Overview Troubleshooting the Management Subsystem Check the following to help isolate a problem in the management subsystem. Problems in the management subsystem could be any of the following: • Management link is down. (Mng LINK LED not lit--also S
Cisco SFE2000P, 5-13 Cisco SCE 2000 4xGBE Installation and Configuration Guide OL-7824-06 Chapter 5 Connecting the Management Interfaces and Performing Initial System Configuration Initial System Configuration Note ACL #0 is a pre-defined list that permits access to all IP addresses. Configuration of access control lists is done in two stages. 1. Create the access control lists. You may create 99 ACLs with a maximum of 20 entries per list. Each entry consists of an IP address, and an indication of whether access is permitted or denied to this IP address. 2. Assign the ACLs to the appropriate management interface. (See .) The dialog permits you to skip the creation/ed
Cisco SFE2000P, 4-10 Cisco SCE 2000 4xGBE Installation and Configuration Guide OL-7824-06 Chapter 4 Installation and Maintenance Installing the SCE 2000 Platform Figure 4-9 Attaching the Crossrails to the Rack Step 5 Repeat steps 2 through 4 on the other side of the rack, keeping the brackets flush against the posts and parallel to the supporting bracket on first side of the rack. How to Mount the System to the Rack When the appropriate mounting brackets are securely installed, the SCE 2000 can be installed into the rack. SUMMARY STE
5-25 Cisco SCE 2000 4xGBE Installation and Configuration Guide OL-7824-06 Chapter 5 Connecting the Management Interfaces and Performing Initial System Configuration Connecting the Management Interface Although not demonstrated in this example, it is recommended that you always view the configuration before applying it. Data collection for the system configuration is completed
Cisco SFE2000P, CHAPTER 7-1 Cisco SCE 2000 4xGBE Installation and Configuration Guide OL-7824-06 7 Basic SCE 2000 Platform Operations This chapter describes how to start up the SCE 2000 platform, reboot, and shutdown. It also describes how to manage configurations. • Starting the SCE 2000 Platform • Managing SCE 2000 Configurations • How to Display the SCE Platform Version Information • How to Display the SCE Platform Inventory • How to Display the System Uptime • Rebooting and Shutting Down the SCE Platform Starting the SCE 20
Cisco SFE2000P, 4-8 Cisco SCE 2000 4xGBE Installation and Configuration Guide OL-7824-06 Chapter 4 Installation and Maintenance Installing the SCE 2000 Platform DETAILED STEPS Step 1 Align the rack-mount bracket to the side of the SCE 2000. Choose the proper bracket for your installation (2-post rack or 4-post rack) as illustrated in Rack-Mounting a SCE 2000 Platform (on page 4-6). Step 2 Insert and tighten three screws. Figure 4-6 Attaching the Mounting Brackets (4-post) Figure 4-7 Attaching the Mounting Brackets (2-post) Step 3 Repeat steps 1 and 2 on the other side of the SCE 2000 . This completes the steps for attaching t
Cisco SFE2000P, 5-9 Cisco SCE 2000 4xGBE Installation and Configuration Guide OL-7824-06 Chapter 5 Connecting the Management Interfaces and Performing Initial System Configuration Initial System Configuration EXAMPLE: Following is an example of changing all passwords. Password encryption is not enabled (default). Enter a User password [cisco]: userinEnter an Admin password [cisco]: mng123Enter a Root password [cisco]: cistechEnable passwords encryption? [no]: Step 4: How to Configure Time Settings The time settings menu configures all time and date related parameters in the system. The time settings
Cisco SFE2000P, 2-7 Cisco SCE 2000 4xGBE Installation and Configuration Guide OL-7824-06 Chapter 2 Introduction to the SCE Platform Information About The SCE Platform SCE 2000 Installation Checklist To assist you with your installation and to provide a historical record of what was done by whom, photocopy the following SCE 2000 Installation Checklist. Indicate when each procedure or verification is completed. When the checklist is completed, place it in your site log along with the other records for you
Cisco SFE2000P, 1-2 Cisco SCE 2000 4xGBE Installation and Configuration Guide OL-7824-06 Chapter 1 General Overview Cisco Service Control Capabilities Service Control for Broadband Service Providers Service providers of any access technology (DSL, cable, mobile, and so on) targeting residential and business consumers must find new ways to get maximum leverage from their existing infrastructure, while differentiating their offerings with enhanced IP services. The Cisco Service Control Application for Broadband adds a new layer of service intelligence and control to existing networks that can: • Report and analyze network traffic at subscriber and aggregate level for capacity planning • Pro
2-4 Cisco SCE 2000 4xGBE Installation and Configuration Guide OL-7824-06 Chapter 2 Introduction to the SCE Platform Information About The SCE Platform Bypass • Continuous green — indicates that the traffic bypasses the SCE 2000 through an internal electrical bypass module. Single SCE 2000 topology — The SCE 2000 is either in bypass or sniffing mode Cascaded topology — Eith
Cisco SFE2000P, 6-7 Cisco SCE 2000 4xGBE Installation and Configuration Guide OL-7824-06 Chapter 6 Cabling the Line Ports and Completing the Installation Connecting the line ports to the network How to Configure the GBE Interface Parameters By default, the SCE 2000 GBE line interface ports are configured with auto-negotiation disabled. The procedure for enabling auto-negotiation for the GBE line interface ports is explained in the following section. Note Auto-negotiation must be disabled when the SCE 2000 is deployed via an external optical splitter (receive-only topology) Note If you change any parameters, you must save
Cisco SFE2000P, 4-15 Cisco SCE 2000 4xGBE Installation and Configuration Guide OL-7824-06 Chapter 4 Installation and Maintenance Removing and Replacing a Power Supply Unit • Dual line feed DC power — requires appropriate cables (hex or loop connectors) (see How to Reconnect DC-Input Power Supply Unit ). The dual power supply units supply hot-swappable, redundant power. Redundant power is useful as a failover; if a situation occurs where one power supply is down (for instance, a power supply fails or a new power supply needs to be installed), the SCE 2000 can continue to run properly using the other power s
Cisco SRW208MP Network Router Datasheet
SRW208MP |
Cisco IPS-4240-K9 - Intrusion Protection Sys 4240 Network Router Getting started manual
IPS-4240-K9 - Intrusion Protection Sys 4240 |
Cisco Nexus 7000 Series Network Router Configuration manual
Nexus 7000 Series |
Cisco 4900M - Catalyst Switch Network Router Installation manual
4900M - Catalyst Switch |
Cisco 805 Network Router Hardware installation manual
805 |
Cisco Catalyst X6748 Network Router Product bulletin
Catalyst X6748 |
Cisco Catalyst X4418 Network Router Datasheet
Catalyst X4418 |
Cisco 1720 Network Router Datasheet
1720 |
# | Manufacturer | Model | Document Type | File | Updated | Pages | Size |
---|---|---|---|---|---|---|---|
1 | UltraDisk | DVR 10 | Operation & user’s manual | ultradisk/dvr-10-654.pdf | 04 Nov 2022 | 11 | |
2 | Beko | CN 151120 | Operation & user’s manual | beko/cn-151120-HTH.pdf | 17 Jul 2022 | 31 | |
3 | Kathrein | NCF 31 | Operation & user’s manual | kathrein/ncf-31-1HR.pdf | 09 Nov 2023 | 2 | |
4 | Weider | 9015 | Manual | weider/9015-68X.pdf | 18 May 2023 | 31 | 2.93 Mb |
5 | Goodman | CONDENSING UNIT | Installation & service reference | goodman-mfg/condensing-unit-CB4.pdf | 15 Jan 2024 | 24 | |
6 | Suunto | T4C | Operation & user’s manual | suunto/t4c-NE2.pdf | 07 Feb 2024 | 54 |
Caimore
厦 门 才 茂 通 信 科 技 有 限 公司Xiamen Caimore Communication TechnologyCo.,LtdAdd: 3F, 1st Building, 23# Wanghai Road, Xiamen Tel: +86-592-5902655Web:http://en.caimore.com Fax:+86-592-5975885User ManualCM520-6X Series RouterXiamen Caimore Communication Technology Co.,LtdAdd: 3F, 1st Building, 23# Wanghai Road, XiamenTel:0592-5902655 Fax:059 …
CM520-6X Series(45 pages) |
Porter-Cable
)NSTRUCTIONMANUAL4HE -ODEL AND 3ERIAL .O PLATE IS LOCATED ON THEMAINHOUSINGOFTHETOOL2ECORDTHESENUMBERSINTHESPACESBELOWANDRETAINFORFUTUREREFERENCE-ODEL.O??????????????????????????????????4YPE???????????????????????????????????????3ERIAL.O ??????????? …
7539(18 pages) |
Moxa Technologies
2014 Moxa Inc. All rights reserved. P/N: 1802002050025 EDS-205A/208A Series Hardware Installation Guide Moxa EtherDevice Switch Sixth Edition, April 2014
…
EtherDevice EDS-208A series(16 pages) |
Nortel
302771-E Rev 00 1Quick Reference for theVersalar Switch Router 15000Carrier Networking Services V15K_2.0.0.0The BCC is case-sensitive. Enter all commands using lowercase letters.To recall any command from the history list, press the up arrow (or Control-p) or downarrow (or Control-n).To display online Help, enter thehelpcommands after either the bcc> prom …
15000(20 pages) |
Festool
Originalbetriebsanleitung/Ersatzteilliste 6Original operating manual/Spare parts list 12Notice d’utilisation d’origine/Liste de pièces de rechange 17Manual de instrucciones original/Lista de piezas de repuesto 23Istruzioni per l’uso originali/Elenco parti di ricambio 29Originele gebruiksaanwijzing/Lijst met reserveonderdelen 35Originalbruksanvisning/R …
MFK 700 EQ(9 pages) |
Omnitron Systems Technology
iConverter 4GT Standalone Module User ManualProduct OverviewThe iConverter 4GT standalone module is an unmanaged four-port 10/100/1000Mbps Ethernet switch that supports Half/Full Duplex and auto-negotiation on each RJ-45 port.Model NumbersModel Number Description8482-4-D Wall mount with External US AC Power Supply8482-4-E Wall mount with External Universal A …
iConverter 4GT(2 pages) |
Airrex Dehumidifier ADH-1000#7XF225: ADH-1000 Dehumidifier Operation & user’s manual ADH-1000, 20 |
Edlund Company Can Opener G-2#14H94S G-2: Edlund Company Can Opener Owner Documentation G-2, 5 |
IEI Technology Motherboard IMBA-9454B-R11IEI Technology Motherboard Quick installation manual (File: iei-technology-imba-9454b-r11-quick-installation-manual-12, 24.12.2023) IMBA-9454B-R11, 12 |
Ramblewood Green Cooktop EC2-30Ramblewood Green Cooktop Operation & user’s manual (File: ramblewood-green-ec2-30-operation-user-s-manual-8, 06/02/2024) EC2-30, 8 |
AmbiCom Adapter WL250N-USB#MVM3XO WL250N-USB: AmbiCom Adapter Owner Documentation WL250N-USB, 29 |
SWEEX Media Player MP420FM#I893VP: MP420FM Media Player Operation & user’s manual MP420FM, 4 |
HP Measuring Instruments 8719ET#N6IL1E: 8719ET Measuring Instruments Service manual 8719ET, 52 |
ELECRAFT Transceiver K3K3 Modification - 5L28T9 K3, 5 |
ECX Toy Boost ECX03004Instruction manual for ECX Boost ECX03004 Toy Boost ECX03004, 19 |
Uniflame Outdoor Fireplace WAD996SPUniflame WAD996SP User Manual (Doc Type: Outdoor Fireplace Owner's manual) WAD996SP, 2 |
Siemens Telephone Accessories Gigaset AS150Telephone Accessories Manual (Siemens Gigaset AS150) Gigaset AS150, 11 |
Emtec Receiver Movie Cube N500HPDF User Manual (@1OUR75), Emtec Movie Cube N500H Receiver (Tuesday 17-10-2023) Movie Cube N500H, 3 |