Cisco UCS C210 Installation And Service Manual

Cisco UCS C210 Manual Online:

3.8, 1340 votes
Cisco UCS C210 User Manual
Cisco UCS C210 User Guide
Cisco UCS C210 Online Manual

Text of Cisco UCS C210 User Guide:

  • Cisco UCS C210, 3-15 Cisco UCS C210 Server Installation and Service Guide OL-20887-02 Chapter To replace or install a hot-pluggable hard drive or SSD, follow these steps: Step 1 Remove the drive that you are replacing or remove a blank panel from an empty bay (see Figure 3-7): a. Press the release button to expose the ejector lever. b. Pull the ejector lever toward you, and then pull the drive sled from the drive bay. c. If you are replacing an existing drive, remove the drive from the sled by removing the four screws from the sides of the sled. Step 2 Install a new drive: a. Place the drive in the

  • 3-34 Cisco UCS C210 Server Installation and Service Guide OL-20887-02 Chapter Replacing a PCIe Card This section contains the following topics: • Replacing a PCIe Card, page 3-34 • Special Considerations for the Cisco UCS P81E Virtual Interface Card (N2XX-ACPCI01), page 3-37 • Installing Multiple PCIe Cards and Resolving Limited Resources, page 3-

  • Cisco UCS C210, 3-37 Cisco UCS C210 Server Installation and Service Guide OL-20887-02 Chapter Special Considerations for the Cisco UCS P81E Virtual Interface Card (N2XX-ACPCI01) The Cisco UCS P81E Virtual Interface Card is a standard-profile, half-length, dual-port 10 Gb PCIe card with SFP+. See the following special considerations and prerequisites. • This card is supported in server Generations M1 and M2. • This server supports installation of one of these cards. • This card is supported only in PCIe slots 1 or 2 of this server. N

  • Cisco UCS C210, B-3 Cisco UCS C210 Server Installation and Service Guide OL-20887-02 Appendix AC Power Cord Illustrations This section contains the AC power cord illustrations. Figure B-2 SFS-250V-10A-AR Figure B-3 CAB-9K10A-AU CAB-N5K6A-NA Power Cord, 250 VAC 13 A NEMA 6-15 Plug, North America 8.2 2.5 Figure B-12 CAB-9K12A-NA Power cord, 125 VAC, 13 A, NEMA 5-15 Plug North America 8.2 2.5 Figure B-13 CAB-C13-C14-JMPR Cabinet Jumper Power Cord, 250 VAC 13 A, C13-C14 Connectors 2.2 0.7 Figure B-14 Table B-1 Supported Power Cords for the Server (Continued) Description Length Power Cord Reference IllustrationFeet Meters 186571 25

  • Cisco UCS C210, vii Cisco UCS C210 Server Installation and Service Guide OL-20887-02 Preface This preface describes the audience, organization, and conventions of the Cisco UCS C210 Server Installation and Service Guide. It also provides information on how to obtain related documentation. This guide covers UCS C210 Server Generations M1 and M2. Differences between the generations are noted in text. Related Documentation The documentation set for the Cisco Unified Computing System (UCS) C-Series rack-mount servers is described in the roadmap d

  • Cisco UCS C210, 3-13 Cisco UCS C210 Server Installation and Service Guide OL-20887-02 Chapter Installing or Replacing Components Warning This unit might have more than one power cord. To reduce the risk of electric shock, disconnect the two power supply cords before servicing the unit. Statement 14 Warning Blank faceplates and cover panels serve three important functions: they prevent exposure to hazardous voltages and currents inside the chassis; they contain electromagnetic interference (EMI) that might disrupt other equipment; and they direct the flow of cooling air through the chassis. Do not operate the system unless all cards, faceplates, front covers, and r

  • Cisco UCS C210, C-4 Cisco UCS C210 Server Installation and Service Guide OL-20887-02 Appendix In some cases, the default extender backplane requires different cables than the optional expander backplane. The cable connections required for each type of controller are as follows: • Integrated ICH10R: – Extender: Connect one SATA cable from the motherboard connector to the drives 1–4 connector on the extender. – Expander: This integrated controller cannot be used with the expander. • 1064E mezzanine card: – Extender: Connect one long SAS cable from the single connector on the mezza

  • Cisco UCS C210, 2-2 Cisco UCS C210 Server Installation and Service Guide OL-20887-02 Chapter Unpacking and Inspecting the Server Tip Keep the shipping container in case the server requires shipping in the future. Note The chassis is thoroughly inspected before shipment. If any damage occurred during transportation or any items are missing, contact your customer service representative immediately. To inspect the shipment, follow these steps: Step 1 Remove the server from its cardboard container—save all packaging material. Step 2 Compare the shipment to the equipment list provided by your customer service representative and Figure 2-1. Verify that you have all items. Step 3 Check for damage and rep

  • 2-10 Cisco UCS C210 Server Installation and Service Guide OL-20887-02 Chapter Step 2 Use the supplied KVM cable to connect a keyboard and VGA monitor to the console connector on the front panel (see Figure 1-1 on page 1-1). Note Alternatively, you can use the VGA and USB ports on the rear panel. However, you cannot use the front panel console connector VGA and the rear panel V

  • Cisco UCS C210, 3-14 Cisco UCS C210 Server Installation and Service Guide OL-20887-02 Chapter Installing Hard Drives and Solid State Drives The qualified and supported part numbers for this component are subject to change over time. For the most up-to-date list of replaceable components, see the following URL and then scroll to Technical Specifications: http://www.cisco.com/en/US/products/ps10493/products_data_sheets_list.html Tip You do not have to shut down or power off the server to replace hard drives or SSDs because they a

  • THE SPECIFICATIONS AND INFORMATION REGARDING THE PRODUCTS IN THIS MANUAL ARE SUBJECT TO CHANGE WITHOUT NOTICE. ALL STATEMENTS, INFORMATION, AND RECOMMENDATIONS IN THIS MANUAL ARE BELIEVED TO BE ACCURATE BUT ARE PRESENTED WITHOUT WARRANTY OF ANY KIND, EXPRESS OR IMPLIED. USERS MUST TAKE FULL RESPONSIBILITY FOR THEIR APPLICATION OF ANY PRODUCTS. THE SOFTWARE LICENSE AND L

  • Cisco UCS C210, A-2 Cisco UCS C210 Server Installation and Service Guide OL-20887-02 Appendix Environmental Specifications Table A-2 lists the environmental specifications for the server. Power Specifications Table A-3 lists the specifications for each power supply (Cisco part number R2X0-PSU2-650W). You can get more specific power information for your exact server configuration by using the Cisco UCS Power Calculator: http://www.cisco.com/assets/cdc_content_elements/flash/dataCenter/cisco_ucs_power_calculator/ Ta b l e A-2 Environmental Specifications Description Specification Temperature, operating: Derate 1°C

  • Cisco UCS C210, 2-9 Cisco UCS C210 Server Installation and Service Guide OL-20887-02 Chapter Initial Server Setup This section contains the following topics: • Connecting and Powering On the Server (Standalone Mode), page 2-9 • NIC Modes and NIC Redundancy Settings, page 2-12 Connecting and Powering On the Server (Standalone Mode) Note This section describes how to power on the server, assign an IP address, and connect to server management when using the server in standalone mode. To use the server in UCS integration, specific cabling and settings are required. See Installation

  • 2-16 Cisco UCS C210 Server Installation and Service Guide OL-20887-02 Chapter Using the BIOS Recovery Jumper J1E5 to Recover Corrupt BIOS This jumper is adjacent to the CMOS battery (see Figure 2-6 on page 2-15). You can use this jumper to force the server to flash a new BIOS, in the case of a system hang. For example, if the system hangs after a BIOS update,

  • Cisco UCS C210, 2-7 Cisco UCS C210 Server Installation and Service Guide OL-20887-02 Chapter d. Attach the second slide-rail assembly to the opposite side of the rack. Ensure that the two slide-rail assemblies are level and at the same height with each other. e. Pull the inner slide rails on each assembly out toward the rack front until they hit the internal stops and lock in place. Tip You can optionally use the #2 Phillips screws that come with the slide rails to increase stability after installation. These screws can be installed on the front attachment bracket on each assembly, but are not required. Step 2 Attach mounting b

  • Cisco UCS C210, iii Cisco UCS C210 Server Installation and Service Guide OL-20887-02 CONTENTS Preface vii Related Documentation vii Audience vii Organization vii Conventions viii Obtaining Documentation and Submitting a Service Request xiii CHAPTER 1 Overview 1-1 CHAPTER 2 Installing the Server 2-1 Unpacking and Inspecting the Server 2-2 Preparing for Installation 2-3 Installation Guidelines 2-3 Rack Requirements 2-4 Required Equipment 2-4 Slide Rail Adjustment Range

  • Cisco UCS C210, CHAPTER 3-1 Cisco UCS C210 Server Installation and Service Guide OL-20887-02 3 Maintaining the Server This chapter describes how to diagnose hardware problems with status LEDs and how to install or replace hardware components, and includes the following sections: • Server Monitoring and Management Tools, page 3-1 • Status LEDs, page 3-2 • Preparing for Component Installation, page 3-7 • Installing or Replacing Components, page 3-13 Server Monitoring and Management Tools Cisco Integrated Management Interface (CIMC) You can monitor the server inventory, health, and system event

  • Cisco UCS C210, 3-28 Cisco UCS C210 Server Installation and Service Guide OL-20887-02 Chapter Figure 3-14 Removing and Replacing CPUs and Heatsinks 1 Captive heatsink screws (two per CPU) 2 CPU cover plate (open) 3 CPU socket alignment keys (two) 4 CPU socket latch (open) 195923 1 4 2 3 1

  • Cisco UCS C210, CHAPTER 2-1 Cisco UCS C210 Server Installation and Service Guide OL-20887-02 2 Installing the Server This chapter describes how to install the server and includes the following sections: • Unpacking and Inspecting the Server, page 2-2 • Preparing for Installation, page 2-3 • Installing the Server Into a Rack, page 2-5 • Initial Server Setup, page 2-9 • System BIOS and CIMC Firmware, page 2-13 Note Before you install, operate, or service a server, review the Regulatory Compliance and Safety Information for Cisco UCS C-Series Servers for important safety information.

  • Cisco UCS C210, 3-17 Cisco UCS C210 Server Installation and Service Guide OL-20887-02 Chapter Installing a DVD Drive The qualified and supported part numbers for this component are subject to change over time. For the most up-to-date list of replaceable components, see the following URL and then scroll to Technical Specifications: http://www.cisco.com/en/US/products/ps10493/products_data_sheets_list.html Warning Class 1 laser product. Statement 1008 To replace a DVD drive, follow these steps: Step 1 Remove a DVD drive: a. Power off the server as described in the “Shutting Down and Powering Off the Server”

  • Cisco UCS C210, 3-40 Cisco UCS C210 Server Installation and Service Guide OL-20887-02 Chapter Replacing a SAS Extender or SAS Expander This server has two factory-configurable options for hard drive backplane connection: the SAS extender or the SAS expander. Note The extender and the expander are field-replaceable, but you cannot upgrade an extender to an expander after-factory. The SAS Extender Figure 3-20 shows the SAS extender. Figure 3-20 SAS Extender • The extender supports connection for up to eight drives. Connector 1 provides connection for drives 1–4, connector 2 provides connection for drives 5–8. See Supported RAID Controllers and Required Cables, page C-1 for the

  • Cisco UCS C210, 3-24 Cisco UCS C210 Server Installation and Service Guide OL-20887-02 Chapter Memory Mirroring and RAS • The CPUs support memory mirroring only when Channels A and B on CPU 1 are populated with DIMMs that are identical in configuration, size, and speed. Do not populate channel C. If three channels are populated with DIMMs, memory mirroring is automatically disabled. • If DIMMs on CPU 2 are populated, channels D and E must be populated with DIMMs that are identical in configuration, size, and speed. Do not populate c

Related Products and Documents (Server):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 NI 9477 Getting started manual ni/9477-7G5.pdf 21 Feb 2023 18
2 Polaroid PDV-523M2 Operation manual polaroid/pdv-523m2-LY1.pdf 03 Apr 2023 41
3 HP Laserjet,Color Laserjet 4550 Operation & user’s manual hp/laserjet-color-laserjet-4550-NLM.pdf 07 Sep 2022 104 3.11 Mb
4 Sony 4-147-228-12(1) Operating instructions manual sony/4-147-228-12-1-P9H.pdf 17 Oct 2022 123 3.18 Mb
5 Planet VIP-160 Operation & user’s manual planet-technology/vip-160-KQG.pdf 06 Aug 2023 24
6 LG 60LN5600 Specifications lg/60ln5600-OQM.pdf 26 Jan 2024 2

Similar Resources:

  • Vxl

    Itona LQ Series

    (5 pages)
    Itona LQ SeriesHardware Installation GuideGuide d’Installation HardwareHardware-InstallationsanweisungenInstalación del hardwareThis Class B digital apparatus complies with Canadian ICES-003. Cet appareil numérique de classe B est conforme à la norme canadienne ICES-003. Dieses digitale Class B-Gerät entspricht der Canandian ICES-003. Este apar …
  • Avaya

    MCC1

    (6 pages)
    Job Aid Cabling Guide—MCC1 and SCC1 Media GatewayCabling Guide — MCC1 and SCC1 Media Gateway 1555-245-771, Issue 2, June 2004Job AidCabling Guide—MCC1 and SCC1 Media GatewayThis cabling guide provides graphical representations on various cable connections for the Avaya MCC1 and SCC1 Media Gateways used in an S8700 Multi-Connect configuration. Different …
  • JVC

    DD-8E

    (89 pages)
    SERVICE MANUALCOPYRIGHT © 2006 Victor Company of Japan, LimitedNo.MB5632006/11NETWORK MEDIA SYSTEMMB563200611DD-8B,DD-8E,DD-8EN,DD-8EV,DD-8EE,DD-3B,DD-3E,DD-3EN,DD-3EV,DD-3EELead free solder used in the board (material : Sn-Ag-Cu, melting point : 219 Centigrade)TABLE OF CONTENTS1 PRECAUTION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . …
  • Siemens

    SINUMERIK 840D sl

    (1102 pages)
    Basesoftware and operating software ___________________ ___________________ ___________________ ___________________ ___________________ ___________________ ___________________ SINUMERIK SINUMERIK 840D sl Basesoftware and operating software Commissioning Manual Valid for Control: SINUMERIK 840D sl/840DE sl Software: CNC software V4.5 SP2 SINUMERIK …
  • Dell

    PowerEdge R210 II

    (16 pages)
    Intel Xeon E3-1200 v2 Series Processors—Information UpdateImportant Information• The Dell PowerEdge R210 II and T110 II systems, originally installed with Intel Xeon E3-1200 series processors, support Intel Xeon E3-1200 v2 series processors after a BIOS and baseboard management controller (BMC) firmware upgrade. • To support Intel Xeon E3-1200 v2 serie …
  • Dell

    1955

    (162 pages)
    www.dell.com | support.dell.comGetting StartedWith Your SystemZačínáme se systémemGuide de mise en routeErste Schritte mit dem SystemΤα πρώτα βήµατα Με το σύστηµά σαςRozpoczęcie pracy z systememНачало работы с системойProcedimientos iniciales con el sistemaModel BMX …

Comments, Questions and Opinions: