Cisco AJ732A - MDS 9134 Fabric Switch Release Note
|
Cisco AJ732A - MDS 9134 Fabric Switch, Send documentation comments to [email protected] 14 Cisco Nexus 5000 Series Release Notes, Release 4.0(1a)N1(1a) OL-16601-01 Caveats • CSCsv00989 Symptom: The command show interface ethernet transceiver details may show all zero values for DOM-capable 1 G SFP. Workaround: None. • CSCsu48008 Symptom: When a Virtual Fibre Channel (VFC) interface is down, the fcIfOperStatusCause MIB object does not report the correct reason. Workaround: Get the OperStatus from the CLI using the show interface vfc x command. • CSCsu77946 Symptom: Within a configuration session, when you enable statistics on the PACL add more than 252 ACES to the ACL, and app
Cisco AJ732A - MDS 9134 Fabric Switch, Send documentation comments to [email protected] 3 Cisco Nexus 5000 Series Release Notes, Release 4.0(1a)N1(1a) OL-16601-01 New and Changed Features in Cisco NX-OS Release 4.0(1a)N1(1a) Cisco Nexus 5010 Switch The Cisco Nexus 5010 is a 28-port switch. It is a 1RU, 10-Gigabit Ethernet, Cisco Data Center Ethernet, FCoE, and Fibre Channel switch providing more than 500-Gbps throughput with very low latency. It has the following features: • Twenty fixed 10-Gigabit Ethernet, Cisco Data Center Ethernet, and FCoE SFP+ ports. Eight of the twenty fixed ports support GE and 10GE speed. • One expansion module slot that can be configured to support up to 6 a
Cisco AJ732A - MDS 9134 Fabric Switch, Send documentation comments to [email protected] 10 Cisco Nexus 5000 Series Release Notes, Release 4.0(1a)N1(1a) OL-16601-01 Limitations interface vfc 1/1 no shutdown vsan database vsan 1 interface vfc 1/1 Release 4.0(1a)N1(1a) Converted Configuration vlan 101 fcoe vsan 1 interface Ethernet 1/1 switchport mode trunk switchport trunk native vlan 2 switchport trunk allowed vlan 2,101 spanning-tree bpduguard enable spanning-tree port type edge trunk interface vfc 1 no shutdown vsan database vsan 1 interface vfc 1 Upgrading from Cisco NX-OS 4.0(0)-Based Releases When you upgrade your Cisco Nexus 5000 Series switch f
Cisco AJ732A - MDS 9134 Fabric Switch, Send documentation comments to [email protected] 25 Cisco Nexus 5000 Series Release Notes, Release 4.0(1a)N1(1a) OL-16601-01 Cisco Fabric Manager Zoning In the Edit Local Full Zone Database tool, virtual Fibre Channel interfaces must be specified using the Switch Port WWN method of adding members to a zone. In the Add Members to Zone dialog box, the Switch & Port method and the Domain & Port method are not supported for virtual Fibre Channel interfaces. Caveats This section lists the Cisco Fabric Manager caveats related to managing Nexus 5000 series switches. Open Caveats •
Cisco AJ732A - MDS 9134 Fabric Switch, Send documentation comments to [email protected] 24 Cisco Nexus 5000 Series Release Notes, Release 4.0(1a)N1(1a) OL-16601-01 Cisco Fabric Manager no lldp receive no lldp transmit • CSCsq36609 Symptom: For a virtual Ethernet or virtual Fibre Channel interface configured as a SPAN source, changing the interface administrative state results in a memory leak. Deleting and adding SPAN sessions also causes memory leaks. The memory leaks eventually cause a switch reboot. Workaround: Avoid using virtual Ethernet and virtual Fibre Channel interfaces as SPAN sources. Avoid deleting and
Cisco AJ732A - MDS 9134 Fabric Switch, Send documentation comments to [email protected] 2 Cisco Nexus 5000 Series Release Notes, Release 4.0(1a)N1(1a) OL-16601-01 Contents Contents This document includes the following sections: • Introduction, page 2 • New and Changed Features in Cisco NX-OS Release 4.0(1a)N1(1a), page 3 • Release 4.0(1a)N1(1a) Upgrade and Downgrade Issues, page 4 • Changes to the FCoE Model and Related Configuration, page 8 • Limitations, page 10 • Caveats, page 12 • Cisco Fabric Manager, page 24 • Related Documentation, page 26 • Obtaining Documentation and Submitting a Service Request, page 26 Introdu
Cisco AJ732A - MDS 9134 Fabric Switch, Send documentation comments to [email protected] 4 Cisco Nexus 5000 Series Release Notes, Release 4.0(1a)N1(1a) OL-16601-01 Release 4.0(1a)N1(1a) Upgrade and Downgrade Issues The errdisable recovery cause pause-rate-limit Command switch(config)# errdisable recovery cause ? pause-rate-limit Enable timer to recover from pause rate limit error disabled state switch(config)# [no] errdisable recovery cause pause-rate-limit When an Ethernet port experiences severe congestion due to a large amount of flow control (pause) frames received from the peer for an extended duration of time (10s), the port is placed in an error disabled state. The errdisable recovery cause
Send documentation comments to [email protected] 26 Cisco Nexus 5000 Series Release Notes, Release 4.0(1a)N1(1a) OL-16601-01 Related Documentation Related Documentation The Nexus 5000 Series documentation is available at the following URL: http://www.cisco.com/en/US/products/ps9670/tsd_products_support_series_home.html The following are related Cisco Nexus 5000 Seri
Send documentation comments to [email protected] Americas Headquarters: Cisco Systems, Inc., 170 West Tasman Drive, San Jose, CA 95134-1706 USA Cisco Nexus 5000 Series Release Notes, Release 4.0(1a)N1(1a) Current Release: 4.0(1a)N1(1a) -April 23, 2009 Part Number: OL-16601-01 G0 This document describes the features, caveats, and limitations for Nexus 5000 Series switch
Cisco AJ732A - MDS 9134 Fabric Switch, Send documentation comments to [email protected] 5 Cisco Nexus 5000 Series Release Notes, Release 4.0(1a)N1(1a) OL-16601-01 Release 4.0(1a)N1(1a) Upgrade and Downgrade Issues • If the startup-config has an RBAC role configured with more than 35 rules, then after a downgrade to the 4.0(0)N1(2a) release, the show running-config command causes the vshd process to core dump. This is due to a caveat (CSCsy37432). The workaround is to remove rules from the roles configuration in a way that a role does not have more than 35 rules before downgrading to the 4.0(0)N1(2a) release. • If the startup-config has an RBAC role configured with more than 20 role
Cisco AJ732A - MDS 9134 Fabric Switch, Send documentation comments to [email protected] 11 Cisco Nexus 5000 Series Release Notes, Release 4.0(1a)N1(1a) OL-16601-01 Limitations The correct VLAN tag is applied on the frame as it goes out the SPAN destination. The only exception is if frames ingress on a SPAN source port on an invalid VLAN. In this case, vlan 0 will be applied on a spanned frame. • RADIUS and AAA startup configuration is lost when you upgrade from 4.0(0)N based releases to 4.0(1a)N based releases and later releases or when you downgr
Cisco AJ732A - MDS 9134 Fabric Switch, Send documentation comments to [email protected] 21 Cisco Nexus 5000 Series Release Notes, Release 4.0(1a)N1(1a) OL-16601-01 Caveats • CSCsr39670 Symptom: Although SNMP notification is enabled on the switch, traps for the power supply and fan modules are not received. Workaround: None. • CSCsr47531 Symptom: When a VSAN is configured as SPAN source, traffic from all the member ports is spanned to the SPAN destination port. When a switch is rebooted, the VSAN SPAN source remains in the down state. Workaround: Delete and add the VSAN sources for the SPAN session. Resolved Caveats—
Cisco AJ732A - MDS 9134 Fabric Switch, Send documentation comments to [email protected] 16 Cisco Nexus 5000 Series Release Notes, Release 4.0(1a)N1(1a) OL-16601-01 Caveats • CSCsr64291 Symptom: When a port is congested due to traffic from multiple inputs, the traffic mapped to a user-defined QoS class can get discarded at a very slow rate (fewer frames per second) in spite of being configured with strict priority scheduling. Workaround: None. • CSCsr68690 Symptom: When an egress SPAN is configured on a port transmitting jumbo or large frames, the spanned frames are truncated to 2384 bytes. Workaround: None. • CSCsl21529 Symptom: An incorrect MTU value is displayed in the show interface command output. The Nex
Cisco AJ732A - MDS 9134 Fabric Switch, Send documentation comments to [email protected] 13 Cisco Nexus 5000 Series Release Notes, Release 4.0(1a)N1(1a) OL-16601-01 Caveats • CSCsv70815 Symptom: The default VRF is the system default for a VRF setting. Ideally, applications using VRF (such as TACACS+) assume a default VRF value if a VRF configuration is not specified by the administrator. However, TACACS+ is not set up properly unless the default VRF is configured. Workaround: The Cisco Nexus 5000 Series switches support two possible VRFs, the default and the management. Configure the desired VRF when using TACACS+ service. You can co
Cisco AJ732A - MDS 9134 Fabric Switch, Send documentation comments to [email protected] 20 Cisco Nexus 5000 Series Release Notes, Release 4.0(1a)N1(1a) OL-16601-01 Caveats • CSCso91286 Symptom: When TACACS+ authentication is used to authenticate AAA users using ACS, the Cisco Nexus 5000 Series switch ignores the user to role binding information specified in the ACS. Users are logged in with their default roles. The default role for a new user is network-operator and for a user who is an administrator is network-admin. Workaround: The user-to-role binding n
Cisco AJ732A - MDS 9134 Fabric Switch, Send documentation comments to [email protected] 18 Cisco Nexus 5000 Series Release Notes, Release 4.0(1a)N1(1a) OL-16601-01 Caveats Workaround: Configure a shorter query interval on the IGMP router to reduce the time it takes for ip-multicast traffic to converge in this topology. • CSCsq35728 Symptom: When a SAN port channel is created, the following syslog message is displayed: 2008 May 20 06:09:13 switch %PORT_CHANNEL-3-MSG_SEND_FAILURE: failed to send MAP_PARAM_FROM_CHANNEL to sap 45: Broken pipe" There is no functionality loss and this message can be ignored
Cisco AJ732A - MDS 9134 Fabric Switch, Send documentation comments to [email protected] 23 Cisco Nexus 5000 Series Release Notes, Release 4.0(1a)N1(1a) OL-16601-01 Caveats • CSCsq27576 Symptom: FC-SP authentication is supported only with a switch over the E/TE port. Authentication with native Fibre Channel (FC) and Fibre Channel over Ethernet (FCoE) initiator or target is not supported. Workaround: None. • CSCsq32710 Symptom: SNMP users configured with a user-defined roles cannot retrieve any Fibre Channel interfaces. Workaround: Use one of the predefined roles on the switch such as network-admin or netwo
Cisco AJ732A - MDS 9134 Fabric Switch, Send documentation comments to [email protected] 12 Cisco Nexus 5000 Series Release Notes, Release 4.0(1a)N1(1a) OL-16601-01 Caveats Caveats This section includes the following topics: • Open Caveats, page 12 • Resolved Caveats—Cisco NX-OS Release 4.0(1a)N1(1a), page 18 • Resolved Caveats—Cisco NX-OS Release 4.0(1a)N1(1), page 19 • Resolved Caveats—Cisco NX-OS Release 4.0(0)N1(2a), page 21 • Resolved Caveats—Cisco NX-OS Release 4.0(0)N1(2), page 22 • Resolved Caveats—Cisco NX-OS Release 4.0(0)N1(1a), page 23 • Resolved Caveats—Cisco NX-OS Release 4.0(0)N1(1), page 24 Open Caveats This section lists the open caveats for this release. • CSCsy5371
Send documentation comments to [email protected] 8 Cisco Nexus 5000 Series Release Notes, Release 4.0(1a)N1(1a) OL-16601-01 Changes to the FCoE Model and Related Configuration Changes to the FCoE Model and Related Configuration In the previous Cisco NX-OS 4.0(0)-based releases, the FCoE model allowed Ethernet and FCoE to co-exist on the interface. The virtual interfaces, virtual Ethernet an
Cisco 2960-48TC - Catalyst Switch Switch Datasheet
2960-48TC - Catalyst Switch |
Cisco CATALYST 6000 Switch Installation and configuration note
CATALYST 6000 |
Cisco AP775A - Nexus Converged Network Switch 5010 Switch Configuration manual
AP775A - Nexus Converged Network Switch 5010 |
Cisco Catalyst 4500 Series Switch Overview
Catalyst 4500 Series |
Cisco SOHO Series Switch Quick reference manual
SOHO Series |
Cisco Catalyst Series Switch 2940 Switch Datasheet
Catalyst Series Switch 2940 |
Cisco 2955 Switch Hardware installation manual
2955 |
Cisco AJ732A - MDS 9134 Fabric Switch Switch Installation manual
AJ732A - MDS 9134 Fabric Switch |
# | Manufacturer | Model | Document Type | File | Updated | Pages | Size |
---|---|---|---|---|---|---|---|
1 | Fisher-Price | M9780 | Owner's manual | fisher-price/m9780-L1D.pdf | 15 May 2023 | 36 | 4 Mb |
2 | Asus | WL-330N3G | Operation & user’s manual | asus/wl-330n3g-177.pdf | 26 Mar 2023 | 70 | 10.35 Mb |
3 | Philips | HTS3378/93 | Operation & user’s manual | philips/hts3378-93-E2V.pdf | 09 Nov 2022 | 54 | 15.86 Mb |
4 | Life Fitness | Lifecycle 9100R | Operation manual | life-fitness/lifecycle-9100r-974.pdf | 01 Jan 2023 | 32 | |
5 | TOTALINE | P374-2300FM | Owner's manual | totaline/p374-2300fm-F8B.pdf | 12 Nov 2023 | 24 | 3.91 Mb |
6 | Vitek | VT-3777 | Manual instruction | vitek/vt-3777-JIQ.pdf | 07 Aug 2022 | 12 | 0.88 Mb |
Toshiba
RD002-RGUIDE-01 2018-03-07 Rev. 1 1 / 15 © 2018 Toshiba Electronic Devices & Storage Corporation MOSFET Driver IC Application and Circuit of the TCK401G Reference Guide RD002-RGUIDE-01
…
TCK401G(15 pages) |
J5create
ULTRA STATIONJUD500QUICK INSTALLATION GUIDEGUÍA DE INSTALACIÓN RÁPIDAKURZANLEITUNG FÜR INSTALLATIONGUIDE D'INSTALLATION RAPIDE快速安裝EN : ES : DE : FR : 日本語 : 繁中文 :
…
JUD500(16 pages) |
Elko
02-3/2018 Rev.4RFJA-12B, RFJA-32BSwitch unit for shuttersENMade in Czech RepublicRFJA-12B/230V, RFJA-12B/120VRFJA-32B/230V, RFJA-32B/120VRFJA-12B/24VDCRFJA-32B/24VDC1/4Characteristics /• The switching unit for blinds has 2 output channels used to control garage doors, gates, blinds, awnings, etc.• It can be combined with Control or System units iNELS R …
Inels RFJA-12B(4 pages) |
3Com
SWITCHINGDATA SHEETOVERVIEW The 3Com®Switch 4500G Gigabit Family deliversflexible quad-speed performance—10/100/1000 and10-Gigabit—and advanced voice-optimized featuressuch as Power over Ethernet (PoE) and auto-voiceVLAN and QoS. This makes the Switch 4500G ideal formedium businesses and small enterprises seeking tobuild a secure converged network.KEY B …
4500G - Switch PWR(8 pages) |
Z-Wave
Z-Wave® Panic Button User’s Manual Introduction The Panic Button is a wireless switch designed to control the Panic or Scene status of other associated devices through the Z-Wave controller. After receiving the signals emitted by the Panic Button, the Z-Wave controller can then give commands or operate according to its own sett …
Panic Button(2 pages) |
WIKA
GBDFEOperating instructionsBetriebsanleitungMode d'emploiManual de instruccionesDruckschalter Typ PSA-31Pressure switch model PSA-31Pressure switch model PSA-31Pressostat type PSA-31Presostato modelo PSA-31
…
PSA-31(124 pages) |
Hitachi Power Tool J300U SeriesJ300U Series Function manual - 1IEY89 J300U Series, 44 |
RCA CD Player RCD200RCA RCD200 User Manual (Operation & user’s manual), @VLWB33 RCD200, 1 |
Mark Bass Music Equipment Nano Mark 300Mark Bass Nano Mark 300 Guide (Owner's manual), @14UT67 Nano Mark 300, 10 |
Siqura IP Camera CD820 SeriesQuick start manual for Siqura CD820 Series IP Camera CD820 Series, 2 |
Denon Receiver RC-7001RCI - Remote Control RF/IR Base StationOwner's manual for Denon RC-7001RCI - Remote Control RF/IR Base Station Receiver RC-7001RCI - Remote Control RF/IR Base Station, 20 |
Haier Freezer SC-25GHaier Freezer Instruction manual (File: haier-sc-25g-operation-user-s-manual-5, 19/12/2023) SC-25G, 5 |
Belkin Switch 4x4 USB Peripheral SwitchSwitch PDF Operation & user’s manual 4x4 USB Peripheral Switch, 20 |
Gardena Lawn Mower R40LiR40Li (Lawn Mower ePDF User Manual, #AA149K) R40Li, 290 |
Bosch Cooktop NIT5065UC - Strips 500 30" Induction CooktopCooktop #M58TA6 NIT5065UC - Strips 500 30" Induction Cooktop, 92 |
LSI PCI Card DB15-000556-12PCI Card #37U38V DB15-000556-12, 39 |
Haier Washer slim3User Guide: Haier slim3 (E4837Q, Upd.01/10/2023) slim3, 26 |
Monitor Audio Subwoofer RS W12Owner's manual for Monitor Audio RS W12 Subwoofer RS W12, 15 |