Manualios.com

Cisco Cisco Line Card 4500 E-Series Installation Manual

  • Cisco Line Card 4500 E-Series Switch
  • maAoYETC2l8J.
  • Installation Manual
  • PDF / Adobe Acrobat Reader
  • 172

Cisco Cisco Line Card 4500 E-Series Manual Online:

4.25, 701 votes
Cisco Cisco Line Card 4500 E-Series User Manual
Cisco Cisco Line Card 4500 E-Series User Guide
Cisco Cisco Line Card 4500 E-Series Online Manual

Text of Cisco Cisco Line Card 4500 E-Series User Guide:

  • Cisco Cisco Line Card 4500 E-Series, 4-5 Catalyst 4500 E-Series Switches Installation Guide OL-13972-02 Chapter 4 Removal and Replacement Procedures Removing and Installing the AC-Input Power Supplies Figure 4-5 Loosening the Captive Screws Caution Use both hands to grasp and support a power supply. Step 5 Grasp the power supply handle with one hand. Place your other hand underneath to support the bottom of the power supply, as shown in Figure 4-6. Figure 4-6 Handling an AC-Input Power Supply Step 6 Slide the power supply out o

  • 1-25 Catalyst 4500 E-Series Switches Installation Guide OL-13972-02 Chapter 1 Product Overview Catalyst 4510R+E Switch Ta b l e 1-11 Catalyst 4510R+E Switch Features Feature Description Chassis Ten horizontal slots. Slots are numbered from 1 (top) to 10 (bottom). Supervisor engines • Supports the following supervisor engines: – Supervisor Engine 7-E –

  • Cisco Cisco Line Card 4500 E-Series, CHAPTER 1-1 Catalyst 4500 E-Series Switches Installation Guide OL-13972-02 1 Product Overview This chapter describes the Catalyst 4500 E-series switches and contains these sections: • Catalyst 4503-E Switch, page 1-2 • Catalyst 4506-E Switch, page 1-6 • Catalyst 4507R-E Switch, page 1-10 • Catalyst 4510R-E Switch, page 1-15 • Catalyst 4507R+E Switch, page 1-19 • Catalyst 4510R+E Switch, page 1-23 Note The Catalyst 4500 series switches are described in a separate publication. Tip For additional information about the Cisco Catalyst 4500 E-series switches (including configuration examples and troubl

  • Cisco Cisco Line Card 4500 E-Series, 4-13 Catalyst 4500 E-Series Switches Installation Guide OL-13972-02 Chapter 4 Removal and Replacement Procedures Removing and Installing the Chassis Fan Tray Assembly Step 11 Check the power supply and system status from the system console by entering the show power command. For more information on the commands, see the command reference publication for your switch and software. Step 12 If the LEDs or the show power command (Cisco IOS) output indicate a power problem or other system problem, see Chapter 5, “Troubleshooting,” for more information. Removing and Installing the Chassis Fan Tray Assembly This section describes how to remove and install th

  • A-18 Catalyst 4500 E-Series Switches Installation Guide OL-13972-02 Appendix A Power Supply Specifications 1400 W Triple-Input DC-Input Power Supply 1400 W Triple-Input DC-Input Power Supply The 1400 W triple-input DC-input power supply (PWR-C45-1400DC), shown in Figure A-5, is supported in the following Catalyst 4500 E-series switches. • Catalyst 4503-E • Cata

  • Cisco Cisco Line Card 4500 E-Series, 1-24 Catalyst 4500 E-Series Switches Installation Guide OL-13972-02 Chapter 1 Product Overview Catalyst 4510R+E Switch Figure 1-6 Catalyst 4510R+E Switch Chassis (Front View) Table 1-11 describes the features of the Catalyst 4510R+E switch. 1 Fan tray 3 Supervisor engines (primary in slot 5 and secondary in slot 6) 2 Switching modules (slots 1–4, 7–10) 4 Power supplies + E S e r i e s RE M O VE L ABEL FO R SY S TEM G ROUND Mini mum Cat 4500 Software Requi rement V e rsi on: I OS: 12.2(37) S G 1 2 279247 4506 2 3 4 1 S T A T U S 1 2 1 1 1 0 9 8 7 6 5 4 3 2 1 1 4 1 3 1 6 1 5 2 8 2 7 2 6 2 5 2 4 2 3 2 2 2 1 2 0 1

  • iii Catalyst 4500 E-Series Switches Installation Guide OL-13972-02 CONTENTS Preface vii Audience vii Organization vii Conventions viii Statement 1071—Warning Definition ix Related Documentation xiv Hardware Documents xv Software Documentation xv Cisco IOS Documentation xvi CHAPTER 1 Product Overview 1-1 Catalyst 450

  • Cisco Cisco Line Card 4500 E-Series, 3-4 Catalyst 4500 E-Series Switches Installation Guide OL-13972-02 Chapter 3 Installing the Switch Unpacking the Switch Unpacking the Switch To check the contents of the shipping cartons, follow these steps: Step 1 Check the contents of the accessories box against the accessories box components checklist and the packing slip that were included with your switch. Verify that you received all listed equipment, including the following: • Rack-mount kit, cable guide kit, and system grou

  • Cisco Cisco Line Card 4500 E-Series, CHAPTER 5-1 Catalyst 4500 E-Series Switches Installation Guide OL-13972-02 5 Troubleshooting This chapter describes how to perform basic troubleshooting on the Catalyst 4500 E-series switch. Problems with the initial startup are often caused by a switching module that has become dislodged from the backplane or a power cord that is disconnected from the power supply. Although temperature conditions above the maximum acceptable level rarely occur at initial startup, some environmental monitoring functions are included in th

  • Cisco Cisco Line Card 4500 E-Series, A-5 Catalyst 4500 E-Series Switches Installation Guide OL-13972-02 Appendix A Power Supply Specifications 1000 W AC-Input Power Supply Ta b l e A-3 1000 W AC Power Supply Power Cords Locale Power Cord Part Number Length Cordset Rating Plug Type North America CAB-US515-C15-US= (was CAB-7KAC=) 8.2 ft (2.5 m) 15 A, 125 VAC NEMA 5-15P Australia, New Zealand CAB-AS3112-C15-AU= (was CAB-7ACA=) 8.2 ft (2.5 m) 15 A, 250 VAC AS/NZS 3112-1993 Europe (except Italy) CAB-CEE77-C15-EU= (was CAB-7ACE=) 8.2 ft (2.5 m) 16 A, 250 VAC CEE 7/7 Italy

  • Cisco Cisco Line Card 4500 E-Series, 2-12 Catalyst 4500 E-Series Switches Installation Guide OL-13972-02 Chapter 2 Preparing for Installation Site Requirements After you install the system ground lug, follow these steps to correctly attach the ESD wrist strap: Step 1 Attach the ESD wrist strap to bare skin as follows: a. If you are using the ESD wrist strap supplied with the FRUs, open the wrist strap package and unwrap the ESD wrist strap. Place the black conductive loop over your wrist and tighten the strap so that it makes good contact with your bare skin. b. If you are using an ESD wrist strap equipped with an alligator clip, open the package and remove the ESD wrist strap. Locate

  • Cisco Cisco Line Card 4500 E-Series, A-36 Catalyst 4500 E-Series Switches Installation Guide OL-13972-02 Appendix A Power Supply Specifications 6000 W AC-Input Power Supply Table A-30 list the 6000 W AC-input power supply LEDs and their meanings. Power supply output Total output depends on the number of inputs connected and the source AC voltage. If two inputs are used, they should both be of the same AC voltage. • 1050 W operation (with one 120 VAC nominal input) – 70.8 A @ 12 VDC (data only) – 12.5 A @ 3.3 VDC (data only) – 18.4 A @ –50 VDC (PoE if used)

  • Cisco Cisco Line Card 4500 E-Series, 2-14 Catalyst 4500 E-Series Switches Installation Guide OL-13972-02 Chapter 2 Preparing for Installation Power Requirements • If you are using a 200/240 VAC power source in North America, the circuit must be protected by a two-pole circuit breaker. • The source AC outlet must be within 6 feet (1.8 meters) of the system and should be easily accessible. • The AC power receptacles used to plug in the chassis must be the grounding type. The grounding conductors that connect to the receptacles should connect to protective earth ground at the service e

  • Cisco Cisco Line Card 4500 E-Series, 2-11 Catalyst 4500 E-Series Switches Installation Guide OL-13972-02 Chapter 2 Preparing for Installation Site Requirements • Use approved power cables only. You have been provided with one or more power cables with your chassis power supply that are intended for use in your country, based on the shipping location. Should you need to purchase additional power cables, ensure that they are rated for the product and for the voltage and current marked on the product’s electrical ratings label. The voltage and current rating of the power cable should be greater than the ratings marked on the label. • To help prevent electrical shock, plug all power cables

  • Cisco Cisco Line Card 4500 E-Series, Index IN-2 Catalyst 4500 E-Series Switches Installation Guide OL-13972-02 chassis dimensions 1-5 fan trays 1-4 front view 1-2 power supplies 1-4 repacking B-1 supervisor engines 1-3 Catalyst 4506-E switches attaching cable guides (figure) 3-7 chassis dimensions 1-9 fan trays 1-8 front view 1-6 installing in racks (figure) 3-6 power supplies 1-8 repacking B-1 supervisor engines 1-7 Catalyst 4507R+E switches chassis dimensions 1-21 fan trays 1-20 p

  • Cisco Cisco Line Card 4500 E-Series, 5-2 Catalyst 4500 E-Series Switches Installation Guide OL-13972-02 Chapter 5 Troubleshooting System Boot Verification • Troubleshooting the Fan Assembly, page 5-6 • Troubleshooting Backplane Modules, page 5-7 • Troubleshooting Switching Modules, page 5-8 • Troubleshooting Supervisor Engines, page 5-10 • Some Problems and Solutions, page 5-14 Note This chapter covers only the chassis component hardware aspects of troubleshooting. For software configuration issues, refer to the software configuratio

  • Contents v Catalyst 4500 E-Series Switches Installation Guide OL-13972-02 Required Tools and Components 4-20 Installing the Remote Power-Cycling Control Wires 4-20 Installing the Ferrite Bead 4-21 CHAPTER 5 Troubleshooting 5-1 System Boot Verification 5-2 Using LEDs to Identify Startup Problems 5-3 System Messages 5-4 Troubles

  • 3-6 Catalyst 4500 E-Series Switches Installation Guide OL-13972-02 Chapter 3 Installing the Switch Installing the Switch in a Rack Figure 3-1 Installing the Switch in the Rack (Catalyst 4506-E Switch Shown) a. Attach the cable guide, if needed, using the M3 screws provided in the cable management kit. The cable guide attaches to prethreaded holes in either L bracket. (See Figure 3-2.)

  • 4-9 Catalyst 4500 E-Series Switches Installation Guide OL-13972-02 Chapter 4 Removal and Replacement Procedures Removing and Installing the DC-Input Power Supplies Figure 4-9 DC-Input Power Supply Figure 4-10 DC Triple-Input Power Supply Step 4 Disconnect the DC-input wires from the terminal block. Disconnect the ground wire last (see Figure 4-11 or Figure 4-12). Warn

  • Cisco Cisco Line Card 4500 E-Series, 5-4 Catalyst 4500 E-Series Switches Installation Guide OL-13972-02 Chapter 5 Troubleshooting System Messages Step 5 If the boot information and system banner are not displayed, verify that the terminal is set for 9600 baud, 8 data bits, no parity, and 1 stop bit and connected properly to the console port. System Messages System messages appear on the console if you have enabled console logging or appear in the syslog if you have enabled syslog. Many messages are for informational purposes only and do not indicate an error condition. Enter the show logging command to display the log messages. To be

  • Cisco Cisco Line Card 4500 E-Series, A-11 Catalyst 4500 E-Series Switches Installation Guide OL-13972-02 Appendix A Power Supply Specifications 1400 W AC-Input Power Supply Figure A-3 1400 W AC-Input Power Supply Features 1400 W AC-Input Power Supply Specifications Table A-7 lists the specifications for the 1400 W AC-input power supply. 1 AC-input receptacle 3 Captive installation screws 2 Power on/off switch 231375 1 2 3 Ta b l e A-7 1400 W AC-Input Power Supply Specifications Item Specification AC-input type Autoranging input with power factor corrector Note Power factor correction is a standard feature on all Catalyst 4500 E-series AC-input power supplies. PFC reduces the reactive component in

  • Cisco Cisco Line Card 4500 E-Series, 4-6 Catalyst 4500 E-Series Switches Installation Guide OL-13972-02 Chapter 4 Removal and Replacement Procedures Removing and Installing the AC-Input Power Supplies Warning Blank faceplates and cover panels serve three important functions: they prevent exposure to hazardous voltages and currents inside the chassis; they contain electromagnetic interference (EMI) that might disrupt other equipment; and they direct the flow of cooling air through the chassis. Do not operate the system unless all cards, faceplates, front covers, and rear c

  • Cisco Cisco Line Card 4500 E-Series, 5-12 Catalyst 4500 E-Series Switches Installation Guide OL-13972-02 Chapter 5 Troubleshooting Troubleshooting Supervisor Engines Useful CLI Commands Some problems can be solved by resetting the supervisor engine. Use the hw-module module <n> reset power-cycle command to reset a switching module, or remove and re-insert the switching module, which resets, restarts and power cycles the switching module. Pressing the reset button on the supervisor engine causes the software to reload, but does not power cycle the supervisor engine. Note When you power-cycle or remove a supervisor engine in a redundant system the other supervisor engine becomes the active supervisor and

  • Cisco Cisco Line Card 4500 E-Series, 3-7 Catalyst 4500 E-Series Switches Installation Guide OL-13972-02 Chapter 3 Installing the Switch Establishing the System Ground Connection Figure 3-2 Attaching the Cable Guide to the Chassis (Catalyst 4506-E Switch Shown) Step 6 Verify that on all installed supervisor engines and switching modules, the ejector levers are completely closed and that the captive installation screws are tight. Establishing the System Ground Connection The system (NEBS) ground provides additional grounding for EMI shielding requirements and grounding for the low voltage supplies (DC-DC converters) on the modules and is intended to satisfy the Telcordia Technologies NEBS r

  • Cisco Cisco Line Card 4500 E-Series, A-9 Catalyst 4500 E-Series Switches Installation Guide OL-13972-02 Appendix A Power Supply Specifications 1300 W AC-Input Power Supply Ta b l e A-6 1300 W AC-Input Power Supply Power Cords Locale Power Cord Part Number Length Cordset Rating AC Source Plug Type North America CAB-US520-C19-US= (was CAB-7513AC=) 14 ft (4.3 m) 20 A, 125 VA C NEMA 5-20 Australia, New Zealand CAB-A3112-C19-AUS= (was CAB-7513ACA=) 14 ft (4.3 m) 15 A, 250 VA C SAA/3, AS/NZZS 3112-1993 Europe (except Italy) CAB-CEE77-C19-EU= (was CAB-7513ACE=) 14 ft (4.3 m) 16 A, 250 VA C CEE 7/7 Italy CAB-C2316-C19-IT= (was CAB-7513ACI=) 14 ft (4.3 m)

  • Cisco Cisco Line Card 4500 E-Series, CHAPTER 3-1 Catalyst 4500 E-Series Switches Installation Guide OL-13972-02 3 Installing the Switch Revised: October 25, 2011 This chapter describes how to install Catalyst 4500 E-series switches in an equipment rack. The chapter contains the following sections: • Installation Process, page 3-2 • Rack-Mounting Guidelines, page 3-2 • Unpacking the Switch, page 3-4 • Installing the Switch in a Rack, page 3-4 • Establishing the System Ground Connection, page 3-7 • Completing the Installation Process, page 3-9 Warning This unit is intended for installation in restricted access areas. A restricted access

  • Cisco Cisco Line Card 4500 E-Series, A-42 Catalyst 4500 E-Series Switches Installation Guide OL-13972-02 Appendix A Power Supply Specifications Environmental Monitoring Feature Environmental Monitoring Feature With the environmental monitoring and reporting feature, you can keep your system running by resolving adverse environmental conditions before a loss of operation. The power supply monitors its own internal temperature and voltages. In the event of excessive internal temperature, the power supply shuts down to prevent damage. When the power supply returns to a safe operating temperature

Related Products and Documents (Switch):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 AUDIOLINE TEL36CLIP Operating instructions manual audioline/tel36clip-548.pdf 09 Aug 2022 32 0.81 Mb
2 Toshiba M35X-S1143 Specifications toshiba/m35x-s1143-2TR.pdf 26 Oct 2023 7
3 Tripp Lite SU5000XFMRT2U Specifications tripp-lite/su5000xfmrt2u-V1Q.pdf 20 Sep 2023 3 0.1 Mb
4 Icom IC-2340H Service manual icom/ic-2340h-V4X.pdf 04 Oct 2023 61
5 Canon ImageCLASS MF4690 Driver manual canon/imageclass-mf4690-IGJ.pdf 14 Mar 2024 80 2.08 Mb
6 Sony XM-752EQX Specifications sony/xm-752eqx-UQC.pdf 31 Oct 2023 2 0.57 Mb

Similar Resources:

  • Viking

    25AE

    (12 pages)
    1Paging Horns 14Ceiling Speakers 16 How to Designa Paging SystemPlanning--Speaker Placement Volume Control--ZoningProduct RecommendationsProvided byVIKING ELECTRONICSHudson, WI 54016 • (715) [email protected] Our Web Site: www.VikingElectronics.comTelecom and Security Solutions for the 21st Century …
  • steute

    Ex ZS 75 SR

    (16 pages)
    // Ex ZS 75 SR1 / 16steute Technologies GmbH & Co. KG, Brückenstraße 91, 32584 Löhne, Germany, www.steute.comMontage- und Anschlussanleitung / BandschieflaufschalterMounting and wiring instructions / Belt alignment switchInstructions de montage et de câblage / Interrupteur de déport de bandeIstruzioni di montaggio e collegamento / Interruttore di al …
  • ADC

    ADX Active Digital Cross-Connect ADX200

    (2 pages)
    w w w . a d c . c o m • + 1 - 9 5 2 - 9 3 8 - 8 0 8 0 • 1 - 8 0 0 - 3 6 6 - 3 8 9 1Spec SheetADX Active Digital Cross-ConnectADX200 and ADX201The ADX Active Digital Cross-Connect provides an innovative solution for interconnecting systems in telecommunications and exchange buildings, reducing space by 50 to 80 percent, increasing flexibility and …
  • TRENDnet

    TE100-S88

    (2 pages)
    The TE100-S88 is an IEEE 802.3u standard compliant 10/100Mbps Ethernet switching hub designed for 8 auto-sensing 10/100Mbps ports. This 19" rack-mountable hub provides 8 independent segments for 10Mbps and 100Mbps via switching technology. Network traffic that needs to go from one segment to another is automatically forwarded by the switch, without inte …
  • D-Link

    DCM-200

    (12 pages)
    DCM-200 DOCSIS 1.0 DOCSIS 1.1 Upgradable USB/Ethernet Cable Modem Manual Third Edition (Dec 2001) 6DCM200...04 Made in Taiwan RECYCLABLE …
  • D-Link

    DKVM-2KU

    (40 pages)
    2-PORT PS/2 USB KVM SWITCHDKVM-2KUQUICK INSTALLATION GUIDEINSTALLATIONSANLEITUNGGUIDE D’INSTALLATIONGUÍA DE INSTALACIÓNGUIDA DI INSTALLAZIONEINSTALLATIEHANDLEIDINGINSTRUKCJA INSTALACJIINSTALAČNÍ PŘÍRUČKATELEPÍTÉSI SEGÉDLETINSTALLASJONSVEILEDNINGINSTALLATIONSVEJLEDNINGASENNUSOPASINSTALLATIONSGUIDEGUIA DE INSTALAÇÃOΟΔΗΓΟΣ ΓΡΗΓΟΡΗΣ � …

Comments, Questions and Opinions: