Manualios.com

Citizen CSRA-09 Instruction Manual

Citizen CSRA-09 Manual Online:

3.7, 1754 votes
Citizen CSRA-09 User Manual
Citizen CSRA-09 User Guide
Citizen CSRA-09 Online Manual

Text of Citizen CSRA-09 User Guide:

  • Split Type Wall-mounted Room Air Conditioner Instruction Manual Thank you for purchasing of CITIZEN air conditioner. To guarantee safety and best efficiency, please read this manual carefully and keep a suitable storage for reference. Applicable to CSRA-09 CSRA-12 CSRA-18

  • To Consumers 1. The air conditioner should be installed and repaired by the qualified professional technicians according to this manual. 2. The air conditioner must be earthed reliably in installation. 3. Please pull out the plug (shut the power) when it is not in use,especial in the following situations:  In disused seasons  In thunderstorm weather. 4.

  • Quantity 1 1 1 1 1 1 1 2 1 1 1 Order 1 2 3 4 5 6 7 8 9 10 11 Packing List Name Indoor Unit Remove Controller Wall-mounted Plate Instruction Manual Certificate of Quality Guarantee Certificate Remote Controller , s Brace Batteries (AAA SIZE 1.5V) Outdoor Unit Drain Hose Catchment Trough Remarks In the outdoor unit packing box In the indoor unit packing box 2

  • Citizen CSRA-09, SAFETY PRECAUTIONS    Please read the Safety Precaution carefully before operating the unit to ensure correct usage of the unit.    Please observe the following safety precautions when using your air conditioner. If you fail to observe the precautions, it could cause fire, electrical shock or personalinjury. WARNING CAUTION This sign warns of risk of death or serious injury. This sign warns of injury or damage to property. This symbol denotes an action that is PROHIB

  • Citizen CSRA-09, 4 OPERATION PRECAUTIONS WARNING CAUTION   Do not touch or operate with wet hands, this could cause fatal accident.   Avoid an extended period of direct airflow, or you well feel uncomfortable.   Do not insert sticks, fingers or any other object into the unit.   Do not try to repair the unit yourself. It will lead to electricity shock or fire if it is treated improperly. Please contact with the seller.   Do not damage the power cord, or it will cause electricity shock or fire. If

  • Contents To Consumers Features Packing List Safety Precautions Part : Operation Instruction Parts Names and Functions Preparations before Operation Operation Contents Setting Operation of Timer Running Mode Air Direction Controlling Maintenance Method Operation Experience Guide Trouble Shooting Part : Installation Instruction Select the Location for Installatio

  • Citizen CSRA-09, Part    Operation Instruction 1.Parts Names and Functions 1-1 Indoor Unit 6 Outlet vent Intake vent Signal receiving window Air filter nets(2) CSRA-09 CSRA-12 Signal receiving window Indicator Iamps Outlet vent Intake vent Air filter nets(2) Indicator lamps Emergency Switch Emergency Switch

  • Citizen CSRA-09, 7 1-2 Outdoor Unit CSRA-18 CSRA-18 Outlet vent Intake vent Outlet vent Intake vent CSRA-09,CSRA-12 Outlet vent Intake vent Signal receiving window Indicator Iamps Air filter nets(2) Auxiliary buckle(4) Emergency Switch

  • Citizen CSRA-09, 8 1-3 Remote Controller Directions:                      Signal transmitting display: Mode display: cooling dehumidifying heating Temperature setting display: Wind speed display : low medium high automatic Air direction display: (Air direction adjusting) Timer display: Timer setting display: Liquid crystal display Infrared transmit tube Transmit signal to indoor unit Mode key Choose cooling/dehumidifying/heating Temperature setting key(16J30) Wind speed key Choose Low/Medium/High/Auto Air directi

  • Citizen CSRA-09, 2. Preparations before Operation Remove the back cover of the remote controller according to the arrow direction. Fill in two AAA size 1.5V batteries after confirming the porlarities. Reinstall the back cover. 1. 2. 3. 3. Operation Contents Setting 3-1 Illustration of Indicating Lamps 9 1. 2. 3. 4. 5. There may be difference between the temperature set by the remote controller (The air conditioner will stop working while cooling or heating reach this temperature) and measured by temperature measuring device. You can regulate the temperature you want only by the remote controller. It is not certain that the room temperature can reach the temperature displayed on the rem

  • 10 3-2 Pre-set Temperature Operation 3-3 Up and Down Air Direction Controlling Press “MODE” button and select “cooling” or “heating” (Heat Pump Type)mode, then press the temperature setting “” or “” button once, the pre-set temperature will be raised or lowered by 1. Press the air “DIRECTION” button, the ventilating door will act in turns as following: If yo

  • Citizen CSRA-09, 11 6.Air Direction Controlling 7. Maintenance Methods 6-1 Up and down air direction controlling 6-2 Left and right air direction controlling The detailed operation see 3-3. Regulate the left and right air direction by moving the horziontal air direction guide board with hand. Dip the cloth into the cold water or warm water under 40 twist it and then rub the unit. Wash it with soft things similar as sponge and then dry it. If it is very dirty, the neutral detergent solu- tion can be used. Clean the remote controller Clean the intake vent grille        �

  • Citizen CSRA-09, 12 Clean the air filter (once per two weeks is suitable) 1. Hold the two ends of the grille and pull it up-forward, then draw out the air filters downward gently (Do not shake them,or the dust will be raised). 2. Use vaccum cleaner or water to clean them.Please dry them in shade after they have been washed. 3. Hold the two ends of the inlet grille,install the air fil- ters according to the diagram,then shut the inlet grille.    When the machine will not be used for a long period of time: Run it to dry the insi

  • Citizen CSRA-09, 13 9. Trouble Shooting Before calling a serviceman,please check the followings: The air conditioner does not work The compressor stops working In heating operation the unit cannot emits warm air (Heat Pump Type) The efficiency of cooling or heating is low Noise Abnormality of the remote controller display Cold water leaks from the air conditioner Symptom Possible reason    Dew will occur in the air outlet due to the temperature difference.          The power of the batteries has run out. The batteries are inserted inversely. Take out the batteries and insert them again. Attention:The dirt between the fins of the

  • Citizen CSRA-09, 14 Part    Installation Instruction 1. Select the Location for Installation 1-1 Indoor Unit Preface 1-2 Outdoor Unit To guarantee the unit working normally,please read the manual carefully before installation, and try to install it strictly according to this manual. Earth the air conditioner properly. Check the connecting cables and pipes carefully,make sure they are correct and firm before connecting the power of the air conditioner. The maximum length of the connecting pipe between the indoor unit and outdoor unit should be less than 5 metres. It will affect th

  • Citizen CSRA-09, 15 2. Installation of Indoor Unit 2-1 Fix the Wall-mounted Plate Find a rigid parts of the wall (such as pillar etc.),install the plate at the same level,the plate must be fixed horizontally,or it will result in the indoor unit dropping water and abnormal noise.    There should be more than 10cm space at the up,left and right sides while installing the indoor unit. Select the position of the wall-hole. Use an aiguille to drill a hole with ø6.5 cm or so. Insert the wall-through sheath into the hole.          2-2 Drill Hole in the Wall 2-3 Installation of the Power Source Warning: It is absolute wrong to cut the pow

  • Citizen CSRA-09, 16 2-4 Installation of Drain Hose Put together the refrigerent pipe,drain hose and the connecting wire of indoor and outdoor units etc.Wrap them with binding belt.          2-5 Arrangement of Pipes The drain hose should be put below the refrigerant pipe (copper pipe) Do not bend the drain hose or raise it. Do not wrap the drain hose in tensile state.             Arrange the pipes can toward five directions such as back, right, down, left, and

  • Citizen CSRA-09, 17 3-1 Flaring Joint       There are flaring joint equipments on the indoor unit and the outdoor unit. As follow diagram indicates,the refrigerant pipe is used to connect the indoor unit and outdoor unit.    Refrigerant regulation  If the length of the pipe is more than 5m, please refill the refrigerant (fleon R410A). 3-2 Pipe Joint    One of the major reason causes gas leakage is the result of defective flare work, so please check the quality of the flare work according to the follow procedures. Pipe length less than 5m more than 5m need not to refil

  • Citizen CSRA-09,                  18 Connection of indoor unit Connect the thick and thin pipes to the indoor unit. Apply a thin coat of refrigerating oil at the pipes joint. When connecting, first aim at the centre, then screw the first 3-4 turns of the connecting nut by hand. Take the wring torque diagram as the standard of indoor pipe’s connection, use two spaners to tighten them, over-tighten will damage the flared part. Connection of outdoor unit Take the same way as that of the indoor unit, connect the pipe with the stop valve pipe of outdoor unit. Use a spanner to grip the valve and use the torque spann

  • Citizen CSRA-09, 19 Attention: Be careful! Do not misconnect the wires or it will cause the air conditioner can’t work normally, or cause fuses blown out or other serious accidents. The method of installation is as the diagram indicates, connect the power wires according to the stipulated fixed colour and order. a. Distinguish the colour, order and diameter of wires clearly while installation,the power wires between the indoor unit and the outdoor unit must be corresponding with each other, never be mi

  • Citizen CSRA-09, 20 4-2 Test Run Procedure Before test run operation, please check all the connecting wires and pipes carefully to see if they are correctly connected and firm, the stop valve has been completely opened or not, and if the air conditioner has been connected to earth reliablly. 1. Connect the air conditioner system to the power source, aDusound emitted by the indoor buzzer should be heard . 2. Turn on the air conditioner with the remote controller. Please choose the heating mode and set temperature at 25=to check its heating function. Please choose thecooling�

  • Citizen CSRA-09, Cooling & Heating 3500W 3800W 1090W 1052W 11kg/37kg 550m 3 /h 3.6MPa 1.2MPa R410A/1.1kg Main Specifications The above-mentioned cooling capacity and heating capacity are measured un- der a certain standard situation, it may be changed as the ambient temperature or humidity varies. Please use the unit when the outdoor temperature ranges from -7to 43 The power supply of Air conditioner should be connected to separate circuit. Extra notice will not be given if there are changes of the data, please take the nameplate o

Related Products and Documents (Air Conditioner):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Sylvania SY14Q5184CUQ-A Instruction manual sylvania/sy14q5184cuq-a-XJJ.pdf 05 Aug 2023 26
2 Sanus Systems Motorized Mount LA112 Installation manual sanus-systems/motorized-mount-la112-Q28.pdf 19 Sep 2022 31 11.54 Mb
3 Rola 4 Place Bike Carrier - Folding Assembly and installation instructions manual rola/4-place-bike-carrier-folding-XK5.pdf 30 May 2023 9
4 Kozy-World EIR1123 Installation instructions and owner's manual kozy-world/eir1123-QAY.pdf 21 Oct 2023 24
5 DAHON SRAM SPARC 16V Manual  dahon/sram-sparc-16v-KPW.pdf 20 Aug 2022 80 1.44 Mb
6 3Com IntelliJack NJ105 Operation & user’s manual 3com/intellijack-nj105-HAA.pdf 23 Nov 2022 44 0.37 Mb

Similar Resources:

  • McLean Cooling Technology

    LOBOY 16

    (12 pages)
    INSTRUCTION MANUAL FOR: LOBOY 16 AIR CONDITIONERS McLean Midwest Corp. dba: McLean Cooling Technology 11611 Business Park Blvd. N Champlin, MN 55316 Tel: 763-323-8200 Fax: 763-576-3200 www.mcleancoolingtech.com …
  • Samsung

    ND022QHXEA

    (38 pages)
    02_ featuresFor easy future reference write the model and serial number down. You will find your model number on the right side of the air conditioner.Model # Serial # features of your new air conditioner• Cool Summer OfferOn those hot sweltering summer days and long restless nights, there is no better escape from the heat than the cool comforts of h …
  • Zibro

    SC 3032

    (2 pages)
    SC 3032Product rangeBrand nameModelColourEAN code indoor unitEAN code outdoor unitCooling HeatingEER / COP * W/W 3.23 3.7EE-Class / Heating performance * A ACapacity * (nom.) kW 3.2 3.6Capacity * (min-max) kW 0.7 - 4.0 0.8 - 4.7Power consumption (nom.) kW 0.99 0.97Power supply V/Hz/PhCurrent ** AAir flow (min-max.) **m3/hFor rooms up to **m3Dehumidification …
  • Sharp

    AY-A079E

    (36 pages)
    AY/AE-A079EAY/AE-A099E1PageSPECIFICATIONS ........................................................................................................................................... 2EXTERNAL DIMENSIONS............................................................................................................................... 3WIRING DIAGRAMS ............. …
  • LG

    TS-C096YDA1

    (9 pages)
    Room Air ConditionerSVC MANUAL(Exploded View)MODEL : TS-C096YDA1 TS-C126TDA1 CAUTIONBefore Servicing the unit, read the safety precautions in General SVC manual.Only for authorized service personnel.http://biz.lgservice.com …
  • Mitsubishi Electric

    Mr.SLIM PK-1.6GKL

    (80 pages)
    INSTALLATION MANUALFor safe and correct use, please read this installation manual thoroughly before installing the air-conditioner unit.INSTALLATIONSHANDBUCHZum sicheren und ordnungsgemäßen Gebrauch der Klimaanlage das Installationshandbuch gründlich durchlesen.MANUEL D’INSTALLATIONVeuillez lire le manuel d’installation en entier avant d’installer c …

Comments, Questions and Opinions: