Manualios.com

CompuSTAR CM6300 Installation Manual

CompuSTAR CM6300 Manual Online:

3.55, 683 votes
CompuSTAR CM6300 User Manual
CompuSTAR CM6300 User Guide
CompuSTAR CM6300 Online Manual

Text of CompuSTAR CM6300 User Guide:

  • CM6300 Install Guide Alarm System www.firstechonline.com | www.compustar.com Copyright 2012 Firstech, LLC. Page 30 How To Program Options With 1 Way Remotes With 2 Way Remotes (Wait for chirp between each tap) Scroll Through Menu (Wait for chirp between each tap) Wait for corresponding parking light flash and/ or siren chirp before selecting the option Select Option 1 Select Opt

  • CompuSTAR CM6300, Version 7.11 Please visit www.firstechonline.com for additional installation resources MODEL: RF-2W900FM-5PT Firstech, LLC. 21903 68th Ave S. Kent, WA 98032 Phone. 888-820-3690 Fax. 206-957-3330 Installation Manual CM6300 Alarm System

  • CompuSTAR CM6300, Connector 7 (CN7), 4-Pin to 4-Pin or 6-Pin (Pre-wired Antenna Cable) Connect your antenna cable to this port. You can only use 4 to 4 pin or 4 to 6 pin antenna cables. 6 to 6 Pin antenna cables do not work. Do not use both Connector 7 and Connector 8 at the same time. Pin 1 Yellow - RX input. This wire receives the signal from remote. Pin 2 White - TX output. This wire transmits the signal to remote. Pin 3 Red – Constant 12V positive (+) output. Pin 4 Black – Negative (-) ground. Connector 8 (CN8), 6-Pin to 6-Pin (Pre-wired Antenna Cable) Connect your antenna cable to this port. You can only use 6 to 6 pin antenna cables. 4 to 4 or 4 to 6 Pin antenna cables

  • CM6300 Install Guide Alarm System www.firstechonline.com | www.compustar.com Copyright 2012 Firstech, LLC. Page 21 Option Group 4 Feature Default Setting - I Optional Setting - II Optional Setting - III Optional Setting - IV 4-01 Aux 1 output 0.5sec Latch 0.5 sec Pulse + Program Program 4-02 Aux 2 output 0.5sec Latch 0.5 sec Pulse + Program Program 4-03 Aux 1 output Control

  • CompuSTAR CM6300, CM6300 Install Guide Alarm System www.firstechonline.com | www.compustar.com At the end of menu 4, if diesel mode or auxiliary setting functions were enabled – or if any of the auxiliary outputs were set to “Program”, the duration of these settings can now be adjusted. Following the auxiliary and diesel settings (if selected), the POC options will be displayed on the OP500. The POCs can be set between 0 (default) and 19. All are only available on the CM5000. STEP 3: When finished with the adjustment of the

  • CompuSTAR CM6300, Connector 11 (CN11), 2-Pin (Pre-wired LED) Note: Do not mistake for Thermister port. Pin 1 Black - L.E.D negative (-) ground. Pin 2 Black/White- L.E.D. 3V positive (+) output. Connector 12 (CN12), 4-Pin (Pre-wired RPS) Pin 1 Black - Negative (-) ground. Pin 2 White - Negative (-) paging input. Pin 3 Red - 12V positive (+) output. Pin 4 Yellow - 9V positive (+) L.E.D. output. Connector 13 (CN13), 4-Pin (Pre-wired Shock Sensor or DAS Sensor) Pin 1 Black - Negative (-) ground. Pin 2 White - 2nd stage negative (-) input. (Instant

  • CompuSTAR CM6300, 1-04 Double Pulse Unlock - If enabled, this option will cause the system to double pulse the lock, unlock or both lock and unlock outputs. This can be used for vehicles that need two pulses to unlock or relock the doors. 1-07 Unlock / Disarm with Trunk Release - This option allows the user to configure or disable the unlock/ disarm outputs that trigger with the trunk release command. 1-08 Passive Mode - This option comes with default off. This feature controls what the lock wire does during passive mode. Passive must also be activated by the end user remote according to the

  • 4-07 Aux 2 Input – This option changes the input behavior of the instant trigger wire on the Aux Input Sensor green connector. Default 1:. Will instant trigger with a negative (-) ground input. Option 2: Will pre-warn with a negative (-) ground input. Option 3: Will arm the alarm with a negative (-) ground input. Used when adding an alarm to a

  • CompuSTAR CM6300, CM6300 Install Guide Alarm System www.firstechonline.com | www.compustar.com Thermister (Temperature Sensor) Every 2 Way LCD Firstech RF kit includes an optional thermister, which must be plugged into the 2 pin port of the control module for use. This plug is blue on the CM6300. The use of the thermister allows the 2 Way remote to display the vehicle’s interior temperature on the remote LCD (liquid crystal display) IMPORTANT: New thermister plugs are blue 2 pin connectors on the CM6 series but old white plug thermistors will still work. Hood Pin The hood pin switch triggers the alarm in the event the hood is opened while the system is armed. Backup Battery The backup battery

  • CompuSTAR CM6300, Special Option Groups 1 & 2 CM6300 IMPORTANT: The OP500 is required to change settings in Special Option Groups 1 and 2. Special Option Group 1 2 Aux 1 Output Timing – Option 4-01 must first be set to setting 4. This special option allows a specific output duration for Aux 1 to be programmed. 3 Aux 2 Output Timing – Option 4-02 must first be set to setting 4. This special option allows a specific output duration for Aux 2 to be programmed. 4-8 Aux 3 – 7 Output Timing – O

  • CompuSTAR CM6300, 2 Way LCD remote paging To page a 2 Way LCD remote just tap the ‘Red Circle’ twice. Touch Panel Sensitivity To change touch sensitivity open the driver’s door, hold the button on the back of the RPS Touch until the LEDs go out. Release button and tap again. The number of solid LEDs represent sensitivity of touch, 1 being the lowest, 5 the highest. RPS Touch On or Off You can turn the RPS Touch off from your remote. Just follow the instructions below: STEP 1: Enter remote programming mode by holding down buttons 2

  • CompuSTAR CM6300, STEP 5: The LED on the RPS will confirm your first number by flashing BLUE slowly. Once the LED begins to flash rapidly in BLUE, enter your second number by repeating step 4. STEP 6: Repeat steps 4 & 5 to enter all four numbers. STEP 7: Turn the ignition OFF - the RPS disarm/unlock passcode is now programmed. Follow steps 3 – 5 to enter your disarm/unlock code. Alarm rearm and lock To rearm, knock on your sensor 5 times. Alarm disarm and unlock To disarm, knock on your sensor 5 times. Wait for the Blue LEDs to

  • CompuSTAR CM6300, Placement and Use of Components CM6300 RPS Touch and RPS (Remote Paging Sensor) The RPS is an optional feature. The car call/RPS feature uses a small sensor that is mounted on the inside of your windshield. Important: When using the RPS Touch, you cannot use the LED port or Secure Valet Switch. RPS Touch (Remote Paging Sensor) The new RPS touch has multiple features including: remote paging, 4 digit pin unlock/disarm, and arm/ lock. All features are operated with a simple touch of the sensor. Please program Option 3-16 to Setting 2. RPS Touch

  • CompuSTAR CM6300, Installation Basics CM6300 If you are new to installing Firstech Series Remote Starts and / or Alarms, we highly recommended that you thoroughly review this manual to installing your first unit. Key Points to Consider Before Installation: You must code remotes to this system before anything will function. Program remotes by cycling the ignition ON / OFF five times within seven seconds and tap button 1 (half second) on the first remote, and then tap butt

  • CompuSTAR CM6300, CM6300 Install Guide Alarm System www.firstechonline.com | www.compustar.com Firstech technical support is reserved for authorized dealers only. Monday - Friday: 888-820-3690 (8:00 am – 5:00 pm Pacific Coast Time) Email: [email protected] Web: www.compustar.com/dealersupport Wire Diagrams Click on the “Installogy Access Client” link found on your desktop. If you are a qualified dealer and unable to access this site, call your sales representative or the number above. Technical Support Contacts

  • Installing The FT-EZGO Testing The FT-EZGO STEP 1: Flash your CM6 Series control module for FT-EZGO compatible firmware. STEP 2: Set Option 1-14 to Setting 2, 3 or 4 STEP 3: Connect included 6 Pin to 6 Pin with Ground Wire to control module. If connecting to a 4 Pin to 4 Pin antenna, use the included 6 Pin to 4 Pin adapter. STEP 4: Connect the ground wire from the included 6 Pin

  • CompuSTAR CM6300, 3-02 Confirmation chirps- This feature will allow the user to select a shorter siren output time to simulate a quieter arm/disarm/start output. 3-03 Dome Light Delay – This option is used when connecting the door trigger input to the vehicles dome light circuit. It delays the door trigger input to prevent the door open icon displaying on 2 Way remotes upon lock/arm. 3-04 Starter-Kill – This option determines the mode of the anti-grind/starter-kill relay. Default 1: Anti-grind + starter-kill Option 2: Anti-grind only (no starter-kill) Op

  • CompuSTAR CM6300, Troubleshooting CM6300 Alarm LED Diagnostics When the alarm is triggered the LED on the RPS (if installed), Secure Valet (if installed) and the LED (if in- stalled) will flash a certain amount of times as shown in the table below. This is intended for users with 1 Way remotes. Priority Trigger LED Flash Diagnostic 1 Door/Hood/Trunk/Ign Triggered 2 flashes, break, then repeat 2 2nd Shock Triggered 3 flashes, break, then repeat 3 2nd Auxiliary Input Triggered 4 flashes, break, then repeat 4 P

  • CompuSTAR CM6300, Option Programming Tables CM6300 Option Group 2 Not Available in CM6300 CM6300 Install Guide Alarm System www.firstechonline.com | www.compustar.com Copyright 2012 Firstech, LLC. Page 20 Option Group 3 Feature Default Setting - I Optional Setting - II Optional Setting - III Optional Setting - IV 3-02 Confirmation Chirps Medium (30 ms) Short (15 ms) Normal (60 ms) 3-03 Dome Light Delay Off 5 sec 45 sec Auto 3-04 Starter-Kill Relay Anti-Grind + Starter Kill Anti-Grind Ant

  • CompuSTAR CM6300, Pin 11 Black [POC 5] – Auxiliary 2 250mA negative (-) output. This is an optional output that will provide a programmable output to trigger sliding doors, power windows or whatever other features you’d like. Pin 12 Brown/White - This wire looks for key sense negative (-) input. The proper wire will show a (-) trigger only when the key is in the ignition. The purpose of the key sense is to prevent the system from passively arming or relocking while the key is still in the ignition. Pin 13 Orange [POC 6] - Factory Arm 250mA negative (-) output. This is an optional output that will provide a (-) pulse during lock, after crank and again af

  • CompuSTAR CM6300, How to Program Options on 2-Way Remotes with Separate Lock and Unlock Buttons With 2 Way Remotes (Wait for chirp between each tap) Scroll Through Menu (Wait for chirp between each tap) Wait for corresponding parking light flash and/ or siren chirp before selecting the option Select Option 1 Select Option 2 Select Option 3 Select Option 4 Option Menu 1 Lock + Unlock for 2.5 seconds then Lock + Unlock for 2.5 seconds Tap Key Button Tap Lock Button Tap Unlock Button Hold Trunk Button for 2.5 seconds Tap Key Button Option Menu 2 Lock + Unlock for 2.5 seconds then Lock +

  • CompuSTAR CM6300, 3-11 Auxiliary settings – The Auxiliary settings adds five additional independent auxiliary outputs for a total of seven with this option turned on. Special Option Group 1 allows for independent timing of these outputs. 3-15 Soft Disarm - When a vehicle has factory security, and the Firstech alarm is triggered, you may have both alarms sounding at the same time. In the default setting, silencing the Firstech system will not shut down the factory system, therefore requiring the user to first silence the Firstech system (by tap ping unlock 1 time) and then unlock a 2nd time to si

  • CompuSTAR CM6300, Connector 5 (CN5), 6-Pin Pin 1 Not used Pin 2 Violet/White - Trunk release 250mA negative (-) output. This is an optional output that will release the trunk. Use CN1, Pin 2 if the vehicle is equipped with a (+) trunk release. System will unlock doors and disarm alarm prior to trunk release. Pin 3 Orange/Black - 2nd Unlock 250mA negative (-) output. This is an optional output that will provide a (-) pulse for driver’s priority door lock. IMPORTANT: You must isolate the driver’s door and turn on Option 1-3. Pin 4 Blue - Unlock 250mA negative (-) ou

  • Placement and Use of Components CM6300 CM6300 Install Guide Alarm System www.firstechonline.com | www.compustar.com Copyright 2012 Firstech, LLC. Page 10 The DAS sensor monitors forward movement for remote starting manual transmissions, dual stage impact, and auto adjusting tilt sensor. Follow the steps below to properly setup your DAS sensor. Insta

  • CompuSTAR CM6300, Connector 1 (CN1), 4-Pin Pin 1 Red - Constant 12V positive (+) power input. This wire must be connected. The proper vehicle wire will test (+) 12V at all times while the key is in the off position, the on position and during crank. Pin 2 Green/White – This is a dual-purpose wire that features selectable functionality thru the trunk/light jumper on the control module. It is either a positive (+) parking light output or positive (+) trunk output. This wire carries a 10 amp fuse. Default - Parking light positive (+) output. The proper vehicle wire will test (+) 12V when the parking light switch is in the on position. Optional – Trunk rele

  • CompuSTAR CM6300, Introduction CM6300 Thank you for purchasing this Firstech system for your vehicle. The following installation manual is in- tended for experienced and authorized Firstech technicians. We highly recommend that you contact your local Firstech dealer and seek professional installation. Call 888-820-3690 or visit our websites at www. compustar.com or www.firstechllc.com to locate your nearest dealer. If you need additional or replacement remotes and / or online support please visit www.compustar.co

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Ezviz A1 Quick start manual ezviz/a1-GKK.pdf 05 May 2023 105
2 National Instruments SCXI-1120 Operation & user’s manual national-instruments/scxi-1120-P33.pdf 11 Mar 2024 130
3 Planar PX191 Operation & user’s manual planar/px191-T61.pdf 28 Jan 2024 22
4 Husqvarna B1100028 Software manual husqvarna/b1100028-8LP.pdf 08 Jun 2023 5
5 Telex PS15 Manuallines telex/ps15-49A.pdf 10 Mar 2024 8 0.45 Mb
6 HP COMPAQ 6510B Maintenance and service manual hp/compaq-6510b-254.pdf 12 Dec 2023 166

Similar Resources:

  • Zipato

    Zipabox

    (2 pages)
    TRADEMARKSZipato and the Zipato logo are registered Trademarks. All other product names mentioned herein may be trademarks or registered trademarks of their respective companies. NOTICE Although Zipato has attempted to ensure the accuracy of the content of this manual, it is possible that this document may contain technical inaccuracies, typographical, or …
  • Gentex

    GN-503 SERIES

    (4 pages)
    G N - 5 0 3S E R I E SStandard Product Features• GN-503 available in 120VAC with 9VDC battery back-up• Horn frequency 3100 Hz (nominal)• Meets sensitivity requirements of ANSI/UL 2034• F Model: One (1) set of Form A/Form C contacts that activatefor smoke and/or CO events•• FFFF MMooddeell:: TTwwoo ((22)) sseettss ooff FFoorrmm AA//FFoorrmm CC cco …
  • Nortek

    2GIG eSeries GC2e

    (68 pages)
    PRINTERS INSTRUCTIONS: INSTALLATION & PROGRAMMING GUIDE,CONTROL PANEL,GC2E (ENGLISH) 10022313 Rev-C - INK: BLACK - MATERIAL: 20 LB MEAD BOND WITH 80 LB COATED COVER - SIZE: 8.5 x 11 INCH VERTICAL - SCALING 1-1 - FOLDING: ALBUM FOLD - BINDING: SADDLE-STICHWARNING: OWNER’S INSTRUCTION NOTICE. Not to be removed by anyone except occupant. GC2e Panel Ins …
  • NTI

    ENVIROMUX Series

    (59 pages)
    MAN154-SCM Rev Date 5/8/19 Serial Control Manual E-16D/-5D/-2D Enterprise Environment Monitoring System ENVIROMUX® Series Front View of E-5D Front View of E-2D Front and Rear View of E-16D …
  • Watchguard

    V2

    (56 pages)
    Watchguard Digital V2 Back-To-Base Monitored Alarm System with Wireless Detectors, Remote Controls & Wireless External Siren Designed in Australia. Made in Taiwan I N S T R U C T I O N M A N U A L R e v 1 . 1 Thank you for purchasing an Australian Designed RhinoCo Technology Product. Please read this manual carefull …
  • Liberty Pumps

    ALM-P1

    (12 pages)
    ©Copyright 2012 Liberty Pumps Inc. All rights reserved 1 Supplemental Installation Manual 7247000C MODEL ALM-P1 Supplemental Installation Instructions for your ALM-P1 Alarm Product Description The ALM-P1 is an alarm system that utilizes a water sensor connected to an alar …

Comments, Questions and Opinions: