Comtech EF Data CDD-880 Installation And Operation Manual
|
Comtech EF Data CDD-880, CDD-880 Multi Receiver Router Revision 0 Ethernet Management MN-CDD880 5–14 5.4.4.4.2 Configuration | Demod Figure 5-10. Configuration| Mod page The ‘Configuration | Demod’ page (Figure 5-10) permits the user to configure CDD-880 Tx modulator operations. Note that, for any configuration item requiring text entry, a reference to the operational ranges for that text box is provided to the right of that text box. Global Demodulator Settings Base Rx Frequency – The Base Rx Frequency defines the 70 MHz range for which all demods m
CDD-880 Multi Receiver Router Revision 0 Ethernet Management MN-CDD880 5–10 5.4.4.3.4 Admin | Firmware Figure 5-6. Admin | Firmware page The ‘Admin | Firmware’ page (Figure 5-6) is used to select the c urrent active firmware image to be loaded for operation upon power-up or soft reboot. Slot Information This read-only status section provides infor
Comtech EF Data CDD-880, CDD-880 Multi Receiver Router Revision 0 Appendix A MN-CDD880 A–3 1. Enter the 20-character FAST Option Purchase Access Code here 2. Click when done. A.2.2 Record Serial Number When contacting a Comtech EF Data sales representative during normal business hours to order features, the user will be asked to provide the CDD-880’s serial number. This serial number is provided in the FAST Code section of the ‘Admin | FAST’ page: The user should write this number down prior to contacting Comtech EF Data: Unit Serial Number: _________________________ A.2.3
Comtech EF Data CDD-880, CDD-880 Multi Receiver Router Revision 0 Introduction MN-CDD880 1–9 Figure 1-6. Rx Carrier Level vs. Symbol Rate (L-Band 950 – 2150 MHz) 1.4.2 Low Noise Block Converter (LNB) Support Parameters Specifications LNB Voltage +13 volts, +18 volts per DiSEq, and +24 volts DC at 500 mA maximum 10 MHz Reference • -3 dBm ± 3 dB via Rx connector center conductor • Source: Either Internal modem reference or External reference • Performance: For phase noise, refer to L-Band modulator 10 MHz. • Frequency Stability: Same as the modulator
CDD-880 Multi Receiver Router Revision 0 Installation MN-CDD880 2–3 The kit is installed as illustrated in Figure 2-1 and per the following procedure: Step Description 1 Secure the Adapter Plates to each side of the chassis at the rear, using the #10 flat head screws as shown. 2 Secure the #10 shoulder screws through the Adapter plate mounting slots using the
Comtech EF Data CDD-880, CDD-880 Multi Receiver Router Revision 0 Rear Panel Connector Pinouts MN-CDD880 3–4 3.4.3 MONITOR Connector, DB-15M The MONITOR connector provides the Rx constellation and analog AGC level of the selected demod via a 15-pin Type ‘D’ male (DB-15M) connector. The connector pinouts are as follows: Pin # Description Direction 1 Ground – 2 Reserved – 3 Constellation Q channel Out 4 Reserved – 5 Reserved – 6 Reserved – 7 Reserved – 8 Reserved – 9 Res
Comtech EF Data CDD-880, CDD-880 Multi Receiver Router Revision 0 Ethernet Management MN-CDD880 5–12 5.4.4.4 Configuration Pages The ‘Configuration’ pages are used to configure all router parameters. Click the Interface, Demod, ARP, or Routing tab to continue (the ‘Configuration | LNB’ page is inoperable at this time). 5.4.4.4.1 Configuration | Interface Click the FE Mgt or GE tab to continue. 5.4.4.4.1.1 Configuration | Interface | FE Mgt Figure 5-8. Configuration | Interface | FE Mgt page The ‘Configuration | Interface | FE Mgt’ page (Figure 5-8) perm it
Comtech EF Data CDD-880, CDD-880 Multi Receiver Router Revision 0 Forward Error Correction MN-CDD880 6–5 Figure 6-4. VersaFEC Codec – 8-QAM, Rate 0.642, 0.711, and 0.780 1E-9 1E-8 1E-7 1E-6 1E-5 1E-4 1E-3 1E-2 1E-1 1 2 3 4 5 6 7 8 9 10 11 12 Eb/No in dB Uncoded BPSK/QPSK Comtech VersaFEC® Codec Rate 0.642, 0.711, 0.780 8-QAM 1 2 3 4 5
CDD-880 Multi Receiver Router Revision 0 Flash Upgrading MN-CDD880 4–4 9 Transfer the files: Type "put FW0000423x.bin" (where ‘x’ denotes the revision letter) to begin the file transfers. It will take a few seconds to transfer the file. The process sequences through several blocks – this may take several minutes. When the upgrade image has been r
Comtech EF Data CDD-880, CDD-880 Multi Receiver Router Revision 0 Flash Upgrading MN-CDD880 4–3 3 Download the correct firmware file to this temporary folder. As shown in Figure 4-1: a) Go online to: www.comtechefdata.com ; b) Click on: Support tab; c) Click on: Software Downloads drop-down or hyperlink from Support page; d) Click on: Download Flash and Software Update Files icon; e) Click on: (Select a Product Line) Advanced VSAT Series hyperlink; f) Select the CDD-880 product hyperlink; g) Select th
Comtech EF Data CDD-880, CDD-880 Multi Receiver Router Revision 0 Flash Upgrading MN-CDD880 4–2 4.2 Ethernet FTP Upload Procedure Step Procedure 1 Identify the reflashable product, firmware number, and version for download. a) Using a terminal emulator connected to the serial CONSOLE port, upon power-up of the unit a number of operational parameters, including the firmware number and version, are displayed on the Command Line Interface as per the following example: b) Alternately, when using the Web Server Interface (via the MANAGEMENT FE 10/100 BaseT Fast Ethernet port), the Bootrom, Slot1 and Slot2 firmware loads may be obtained from viewing the ‘Admin | Firmware’ page: Fo
CDD-880 Multi Receiver Router Revision 0 Ethernet Management MN-CDD880 5–11 5.4.4.3.5 Admin | Auto Logout Figure 5-7. Admin | Auto Logout page The ‘Admin | Auto Logout’ page (Figure 5-7) provides a security measure for safeguarding access to a previously logged-in unit. Once configured, the active session will be terminated if the unit is allowed to remain
Comtech EF Data CDD-880, CDD-880 Multi Receiver Router Revision 0 Ethernet Management MN-CDD880 5–22 For each operating demodulator, note the following: Pkts Rx – Packets received. UC Pkts Rx – Unicast packets received. MC Pkts Rx – Multicast packets received. Current (Mbps) – Most recent symbol rate (in megabits per second). Maximum (Mbps) – Peak symbol rate (in megabits per second). (Satellite Rx Statistics) Satellite RX Overrun Errors – Packets dropped after being combined from all 12 demods (aggregate data rate too high). Satellite RX Oversized Errors – Packets dropped because size is greater than 2047 bytes. Satellite RX Undersized Errors – Packets dropped because
Comtech EF Data CDD-880, CDD-880 Multi Receiver Router Revision 0 Ethernet Management MN-CDD880 5–13 Negotiated Link Mode – The read-only actual negotiated line speed and duplex setting for the FE interface is displayed here. The viewable settings are: • 1000 BaseT / Full Duplex • 100 BaseT / Half Duplex • 10 BaseT / Half Duplex • 100 BaseT / Full Duplex (GigE only) • 10 BaseT / Full Duplex Once the desired configuration settings have been made on this page, click [Submit] as needed to save these changes. 5.4.4.4.1.2 Configuration | Inte
Comtech EF Data CDD-880, CDD-880 Multi Receiver Router Revision 0 Preface MN-CDD880 xiii Warranty Policy Comtech EF Data products are warranted against defects in material and workmanship for a specific period from the date of shipment, and this period varies by product. In most cases, the warranty period is two years. During the warranty period, Comtech EF Data will, at its option, repair or replace products that prove to be defective. Repairs are warranted for the remainder of the original warranty or a 90 day extended warranty, whichever is long
Comtech EF Data CDD-880, CDD-880 Multi Receiver Router Revision 0 Ethernet Management MN-CDD880 5–26 5.4.4.6 Utility page Figure 5-17. Utility page The ‘Utility’ page (Figure 5-18) pr ovides an array of top-level system operation controls, configuration storage/selection, and test utilities. Modem Unit Name – The assigned product label is identified here. System Contact / System Location – E-mail and telephone contact information for Comtech EF Data Customer Support are provided here. Click [Submit] once the desired changes have been made to these items.
Comtech EF Data CDD-880, CDD-880 Multi Receiver Router Revision 0 Table of Contents MN-CDD880 v 3.5.1 Alternating Current (AC) Power Connector (Standard) ........................................... 3–5 3.5.2 Ground Connector .................................................................................................... 3–5 CHAPTER 4. FLASH UPGRADING .......................................................................... 4–1 4.1 Flash Updating via Internet ..............................................................
Comtech EF Data CDD-880, CDD-880 Multi Receiver Router Revision 0 Introduction MN-CDD880 1–3 1.3 Features 1.3.1 Physical Description The CDD-880 Multi Receiver Router is constructed as a 1RU-high rack-mounting chassis, which can be free-standing if desired. Handles at the front to facilitate removal from and placement into a rack. The unit uses a single printed circuit board assembly for high reliability. All operational upgrades and enhancements are afforded via remote firmware upgrade. 1.3.1.1 Standard Assemblies Assembly Description Whe
Comtech EF Data CDD-880, CDD-880 Multi Receiver Router Revision 0 Appendix A MN-CDD880 A–2 A.2 Activation Procedure via Web Server (HTTP) Interface The CDD-880 available FAST options are listed – and the FAST Code entry/option activation controls are provided – via the Web Server Interface on the ‘Admin | FAST’ page. Refer to Chapter 5.4. WEB SERVER (HTTP) INTERFACE for a complete overview on CDD-880 operations via this interface. A.2.1 View Currently Installed Features To view currently installed features, the user may refer to the FAST Configuration section of the ‘Admin | FAST’ page: This read-only section displays the CDD-880’s available FAS
DOWNLOAD |
Airlink101 AR325W Network Router Operation & user’s manual
AR325W |
Comtech EF Data Vipersat SLM-5650A Network Router Operation & user’s manual
Vipersat SLM-5650A |
Comtech EF Data Vipersat CDM-570 Network Router Operation & user’s manual
Vipersat CDM-570 |
Comtech EF Data Vipersat CDM-570 Network Router Installation and operation manual
Vipersat CDM-570 |
Comtech EF Data CDM-800 Network Router Installation and operation manual
CDM-800 |
Comtech EF Data Vipersat CDM-570 Network Router Operation & user’s manual
Vipersat CDM-570 |
Comtech EF Data CDM-800 Network Router Installation and operation manual
CDM-800 |
Encore ENDSL-A2+R2 Network Router Specifications
ENDSL-A2+R2 |
# | Manufacturer | Model | Document Type | File | Updated | Pages | Size |
---|---|---|---|---|---|---|---|
1 | Sony | D-NE520 - Atrac Cd Walkman Portable Player | Operating instructions manual | sony/d-ne520-atrac-cd-walkman-portable-player-9Y1.pdf | 06 Oct 2023 | 103 | |
2 | Creative | ZEN SLEEK PHOTO - | Quick start manual | creative/zen-sleek-photo-8X2.pdf | 24 Sep 2022 | 200 | 5.87 Mb |
3 | EdgeStar | PUR700W | Owner's manual | edgestar/pur700w-793.pdf | 12 Mar 2023 | 14 | |
4 | Black & Decker | 90518528 | Instruction manual | black-decker/90518528-Z8L.pdf | 28 Jun 2023 | 5 | 1.77 Mb |
5 | AUSTRALIAN MONITOR | AMIS1202P | Operating manual | australian-monitor/amis1202p-6JN.pdf | 23 Jan 2024 | 5 | 0.26 Mb |
6 | Honeywell | 5804 - Ademco Wireless Key | Installation manual | honeywell/5804-ademco-wireless-key-6T5.pdf | 10 Jul 2022 | 2 | 0.06 Mb |
Optical Systems Design
QUICK INSTALLATION GUIDE OSD2145P SERIES 4-PORT PoE+ 10/100/1000BASE-T + 2-PORT 100/1000BASE SFP ETHERNET SWITCH
…
OSD2145P SERIES(12 pages) |
HP
HP 6125 Blade Switch Series Layer 3 - IP Services Configuration Guide Part number: 5998-3156 Software version: Release 2103 Document version: 6W100-20120907
…
6125G(165 pages) |
Zhone
ADSL2+ Modem (Conexant)6411-A2-xxx✓ ADSL2+ Annex M supportdata rates up to 3MB✓ Multiple PVC up to 8support✓ Static IP, Dynamic RIProuting support✓ Network AddressTranslation (NAT)✓ Universal Plug and PlaySupport✓ TR-069 RemoteManagement SupportADSL2+ Modem with 1 Ethernet and 1 USB,Conexant chipsetThe Zhone 6411-A1 ADSL 2/2+ Ethernet USB Router …
6411(2 pages) |
Woodstock
-20-PARTSW1736 Overarm Router� …
W1736(2 pages) |
Moxa Technologies
— 1 — — 2 — — 3 — PowerTrans Switch PT-7728/7828 Series Hardware Installation Guide Third Edition, May 2008 Package Checklist The Moxa PowerTrans switch is shipped with the following items. If any of these items are missing or damaged, please contact your customer service representative for assistance. y 1 Moxa PowerTrans Switch y Hardw …
PT-7728 Series(2 pages) |
SMC Networks
BarricadeTMBroadband RouterBroadband Router with 4-Port Switch◆ Multi-User Internet Access via Single User Account◆ EZ 3-Click Installation Wizard◆ Configurable Parental Control◆ Stateful Packet Inspection and DoS Support◆ Supports a Wide Variety of Internet Applications◆ Virtual Private Network Using PPTP, L2TP, IPSec Pass-ThroughUser Gui …
7004VBR(112 pages) |
Philips Electric Shaver 7825XLPhilips Product User Manual: 7825XL PDF Specifications - V1O42B 7825XL, 2 |
Runco Projector DTV-1101Owner's operating manual for Runco DTV-1101 Projector DTV-1101, 53 |
Stern Plumbing Product SWAN 1010Stern Plumbing Product SWAN 1010 Installation and maintenance manual SWAN 1010, 20 |
HYOSUNG Motorcycle GT650 - PARTS CATALOGUE#7U83P6 GT650 - PARTS CATALOGUE: HYOSUNG Motorcycle Owner Documentation GT650 - PARTS CATALOGUE, 102 |
Bosch Radio GML 20 ProfessionalGML 20 Professional Original instructions manual - 6YJ1K3 GML 20 Professional, 317 |
GE Microwave Oven Spacemaker LVM1540Spacemaker LVM1540 (Microwave Oven ePDF Manual, #6A1VUH) Spacemaker LVM1540, 40 |
Electrolux Freezer EN3601AOX#LCJA92: EN3601AOX Freezer Operation & user’s manual EN3601AOX, 92 |
VTech Toy Cluck Cluck ChickenOperation & user’s manual for VTech Cluck Cluck Chicken Toy Cluck Cluck Chicken, 8 |
Somogyi Scales HG M 08Somogyi Scales Instruction manual (File: somogyi-hg-m-08-instruction-manual-12, 24.01.2024) HG M 08, 12 |
Brother Printer HL-7050 Series#R594FD HL-7050 Series: Brother Printer Owner Documentation HL-7050 Series, 35 |
American Standard Indoor Furnishing Retrospect 0291.004PDF Guide (@287RI4), American Standard Retrospect 0291.004 Indoor Furnishing (29.01.2024) Retrospect 0291.004, 1 |