Manualios.com

Crestron TPS-IMC-BV Operation Manual

Crestron TPS-IMC-BV Manual Online:

4.9, 2320 votes
Crestron TPS-IMC-BV User Manual
Crestron TPS-IMC-BV User Guide
Crestron TPS-IMC-BV Online Manual

Text of Crestron TPS-IMC-BV User Guide:

  • Crestron TPS-IMC-BV, Crestron TPS-IMC-BV Interface Module Operations Guide - DOC. 5921 Interface Module: TPS-IMC-BV •• i Contents Interface Module: TPS-IMC-BV 1 Description .......................................................................................................................... 1 Functional Description............................................................................................ 1 Physical Description............................................................................................... 1 I/O Ports.........................................................................................

  • Crestron TPS-IMC-BV, Crestron TPS-IMC-BV Interface Module Operations Guide - DOC. 5921 Interface Module: TPS-IMC-BV •• 1 Interface Module: TPS-IMC-BV Description Functional Description The TPS-IMC-BV is designed specifically to serve as an interface module for those Crestron TPS-5000 and TPS-6000 tilt touchpanels that have the RGB Computer Interface Card, TPS-XVGA-BV, installed. A tilt touchpanel is not a stationary user interface; it is impractical to have an excessive amount of cable connections directly to the panel. The design of an interface module provides a multitude of interconnections for the versatile touchpanel. More

  • Interface Module Crestron TPS-IMC-BV 2 •• Interface Module: TPS-IMC-BV Operations Guide - DOC. 5921 composite and S-video input for TV video card. Consult the latest revision of the TPS-VID Operations & Installation Guide (Doc. 5869) for details. Use either the two BNC connectors (unbalanced

  • Crestron TPS-IMC-BV, Crestron TPS-IMC-BV Interface Module Operations Guide - DOC. 5921 Interface Module: TPS-IMC-BV •• 3 Power Pack Specifications CRESTRON POWER PACK OUTPUT SPECS PW-2420RU 24VDC 2A, regulated Power Pack Output Connector Polarity • NET – This four-pin connector is used to connect to other four-wire devices in the Cresnet system. If making network connections to control system or Cresnet peripherals, refer to "Network Wiring" on page 5. • NET/VIDEO – This 10-position RJ45 mates with the TPS-5000 or TPS-6000 touchpanel and

  • Crestron TPS-IMC-BV, Interface Module Crestron TPS-IMC-BV 4 •• Interface Module: TPS-IMC-BV Operations Guide - DOC. 5921 RGB to the Panel Pinouts (RJ45 Port) PIN # DESIGNATION DESCRIPTION 1 V- Vertical Sync (Negative) 2 H- Horizontal or Composite (Negative) 3 R- Red Video (Negative) 4 R+ Red Video (Positive) 5 G- Green Video (Negative) 6 G+ Green Video (Positive) 7 B- Blue Video (Negative) 8 B+ Blue Video (Positive) 9 H+ Horizontal or Composite (Positive

  • Crestron TPS-IMC-BV, Crestron TPS-IMC-BV Interface Module Operations Guide - DOC. 5921 Interface Module: TPS-IMC-BV •• 5 AUDIO INPUT Pinouts (6-Pin Port) PIN DESCRIPTION S Shield R+ Right Positive R- Right Negative L+ Left Positive L- Left Negative S Shield • MIC OUT – The port mates with a three-pin connector, supplied, and produces line level differential output. Description of the pinouts is shown in the table after this paragraph. MICROPHONE Pinouts PIN DESCRIPTION M+ Positive M- Negative S Shield BAL/COAX Video Switch A single two-position toggle switch is centrally located on the top panel of the TP

  • Crestron TPS-IMC-BV, Interface Module Crestron TPS-IMC-BV 6 •• Interface Module: TPS-IMC-BV Operations Guide - DOC. 5921 When calculating the wire gauge for a particular network run, the length of the run and the power factor of each network unit to be connected must be taken into consideration. If network units are to be daisy-chained on the run, the power factor of each network unit to be daisy-chained must be added together to determine the power factor of the entire chain. The length

  • Crestron TPS-IMC-BV, Crestron TPS-IMC-BV Interface Module Operations Guide - DOC. 5921 Interface Module: TPS-IMC-BV •• 7 Hardware Hookup The TPS-IMC-BV serves as an interface between the touchpanel and the Cresnet system. Refer to the illustration after this paragraph for proper connections; apply power last. When making network connections to the control system or Cresnet peripherals, refer to "Network Wiring" on page 5. It is not necessary to make connections to a vid

  • Crestron TPS-IMC-BV, Interface Module Crestron TPS-IMC-BV 8 •• Interface Module: TPS-IMC-BV Operations Guide - DOC. 5921 Problem Solving Troubleshooting The table below provides corrective action for possible trouble situations. If further assistance is required, please contact a Crestron customer service representative. TPS-IMC-BV Troubleshooting TROUBLE POSSIBLE CAUSE(S) CORRECTIVE ACTION Touchpanel does not function. Touchpanel is not communicating to the network. Use Performance Viewport (via SIMPL Windows or VT Pro-e) to poll the network. Verify network connection to the touchpanel. Touchpanel is not rec

  • Crestron TPS-IMC-BV Interface Module Operations Guide - DOC. 5921 Interface Module: TPS-IMC-BV •• 9 Return and Warranty Policies Merchandise Returns / Repair Service 1. No merchandise may be returned for credit, exchange, or service without prior authorization from CRESTRON. To obtain warran

  • Interface Module Crestron TPS-IMC-BV 10 •• Interface Module: TPS-IMC-BV Operations Guide - DOC. 5921 This page intentionally left blank.

  • Crestron TPS-IMC-BV, Crestron TPS-IMC-BV Interface Module Operations Guide - DOC. 5921 Interface Module: TPS-IMC-BV •• 11 This page intentionally left blank.

  • Crestron TPS-IMC-BV, Crestron Electronics, Inc. Operations Guide – DOC. 5921 15 Volvo Drive Rockleigh, NJ 07647 08.01 Tel: 888.CRESTRON Fax: 201.767.7576 Specifications subject to www.crestron.com change without notice.

Related Products and Documents (Network Card):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Panasonic ER?GN25 Operating instructions manual panasonic/er-gn25-Q6Z.pdf 15 Feb 2024 50 1 Mb
2 Yamaha DTXPLORER Drum Trigger Module DTXPLORER Owner's manual yamaha/dtxplorer-drum-trigger-module-dtxplorer-AK2.pdf 31 May 2023 36 0.66 Mb
3 UNI-T UT232 Operating manual uni-t/ut232-E68.pdf 15 Jul 2022 43 1.71 Mb
4 Lenovo ThinkCentre M72z Operation & user’s manual lenovo/thinkcentre-m72z-7J6.pdf 08 Oct 2023 112
5 Philips LR6PS16C Specification sheet philips/lr6ps16c-EVX.pdf 27 Jan 2023 2 0.34 Mb
6 Hasbro Cyclonus 7058 Manual  hasbro/cyclonus-7058-E73.pdf 10 Mar 2023 16 8.89 Mb

Similar Resources:

  • BBV

    BBV RX100

    (40 pages)
    RX100 Dome Interface Receiver Building Block Video Ltd., 17 Apex Park, Diplocks Industrial Estate, Hailsham, East Sussex, BN27 3JU UK. Tel: +44(0)1323 842727 Fax: +44(0)1323 842728 Support: +44(0)1323 444600 www.bbvcctv.com Installation Guide …
  • NetComm

    NP1500

    (2 pages)
    NETCOMM LIMITED ABN 85 002 490 486 • 2-6 Orion Road, LANE COVE, NSW, 2066 • phone 02 9424 2070 • fax 02 9424 2010 • email [email protected]/100 MBPS FAST ETHERNET LAN ADAPTORCORPORATE SERIESProduct Code: NP1500NETWORKING & COMMUNICATIONS CONVERGEDRenowned Intel reliabilityDouble your network data rates up to 20/200Mbps – …
  • Solarflare

    XtremeScale SFN8542

    (12 pages)
    Issue 3 © Copyright 2019 Xilinx, Inc 1Solarflare SFN8542 network adapterQuick Start GuideXtremeScale™ Dual-Port 40GbE QSFP+ PCIe 3.1 Server I/O Adapter Part numbers: SFN8542 and SFN8542-PlusInformation in this document is subject to change without notice.The information disclosed to you hereunder (the “Materials”) is provided solely for the selection …
  • Quantum

    SDLT 600

    (24 pages)
    Quick Start Guide SDLT 600 Tape Drive•iQuantumPROCEDURESGetting Started - - - - - - - - - 1Checking the Tape Drive 1Connecting the Tape Drive 2Confirming the Installation 3Performing a Trial Backup 3VORGÄNGEErste Schritte - - - - - - - - - - 4Überprüfen des Bandlaufwerks 4Anschließen des Bandlaufwerks 5Überprüfen der Installatio …
  • Fairchild

    AC/DC to Logic Interface Optocoupler HCPL-3700

    (11 pages)
    tm HCPL-3700 AC/DC to Logic Interface Optocoupler April 2007 ©2005 Fairchild Semiconductor Corporation www.fairchildsemi.comHCPL-3700 Rev. 1.0.1 HCPL-3700AC/DC to Logic Interface Optocoupler Features ■ AC or DC input ■ Programmable sense voltage ■ Logic level compatibility ■ Threshold guaranteed over temperature (0°C to 70°C) ■ Optoplanar™ c …
  • ADC

    Fiber Optic Panel FL2000 Series

    (19 pages)
    10/07 • 103743AE Fiber Optic Panels38www.adc.com • +1-952-938-8080 • 1-800-366-3891Rack Mount Panel SolutionsSingle Fiber AccessThe FL2000 system is a flexible and modular series of fiber products for today‘s and tomorrow‘s evolving communications and data networks.This product family is a complete line of modular panels developed for rack and …

Comments, Questions and Opinions: