  • D-Link DVG-6004S, 39 Digit Map There are 50 sets of leading digit entries to choose voice routing interface – Auto select, PSTN or VoIP.  Default Call Route: The default call route can be Auto, VoIP, PSTN and Deny. Auto (VoIP first): The call route is VoIP first, and the next is PSTN. VoIP: The call route is VoIP only. PSTN: The call route is FXO only. Deny: The call will be deny if the dial-out number is not in the table.  Enab

  • 53 Provision Settings Fill in the parameters needed of Provision Server from your provider. System Operations (Save Settings) Some settings are effective by Restart. Remember to save all settings by Save Settings before to restart.  Save Settings: Save settings after comple

  • D-Link DVG-6004S, System Information This page shows that the status of VoIP Gateway. There are Port Status, Server Registration Status, WAN Port Information, LAN Port Information and Hardware.  Port Status: It includes if each port registers to Proxy successfully, the lasted dialed number, how many calls each port had since the system is start, etc.  Server Registration Status: It shows the registration status of DDNS, Phone Book Manager, STUN and UPnP.  WAN Port Information: It shows IP address, subnet mask, default gateway and DNS serv

  • D-Link DVG-6004S, 17  Listen Port UDP: It is not necessary to change the protocol of the communication port used by the gateway.  RTP Starting Port UDP: The initial value of port number for transmitting voice data among Gateway(s). Each line requires 2 ports (RTP/RTCP). It is not necessary to change these. For example: If the starting port is 9000, then Line 1 is using 9000(RTP) and 9001(RTCP),

  • 29 a desired channel, if assigned. If you register to a Proxy it MUST be checked. Description: If the remote party wants to assigns L4 (FXO) to make a call, he/she can dial 704 22520199. If this item isn’t checked, the gateway will select a line automatically to call out from. For example

  • D-Link DVG-6004S, 45 Detect function to prevent the FXO from engaging a line. However, if the line of the receiving party is engaged and his/her PSTN uses a voice prompt to replace the traditional beep sound, then the system would not be able to detect a busy tone. Drop Inactive Call should then be used to determine whether or not to end the call. CPT Auto Detect  2 PSTN phone numbers or 2 PBX extension lines are needed.  Connect one of the phone sets to the FXO port (P3 or P4 of MODEL 2S2O).  The line of “Dial Number” must be hook on.

  • D-Link DVG-6004S,  Enable Out-of-Band DTMF: To send DTMF keys (0~9, *, #,) follow the RFC2833 rules or via SIP Info.  Enable Hook Flash Event: The gateway will deliver the flash signal to remote party via RFC2833 or SIP Info.  Payload Type:Payload type of RFC2833.  Uses Second CPT for VoIP Call: This function is usually applied when the user selects VoIP as the primary path for outgoing calls and PSTN as the backup. By enabling this function, the gateway will generate a different set of tones to inform the user that VoIP is in service. Should VoIP fails and fallback to PSTN, the user will hear PSTN tones instead of the second set C

  • CPT/Cadence Settings CPT/Cadence setting parameters serve as the basis of an FXO interface to determine whether or not a PSTN-call receiving party has hung up the phone. If the following parameters differ from the parameters of the actual assigned lines, it could cause the FXO to continue to engage a line. Busy Tone Cadence Measurement  Busy Tone Cadence Measuremen

  • D-Link DVG-6004S, 15 PPPoE Character Conversion Table Number Input Key Upper Case Letter Input Key Lower Case Letter Input Key Symbol Input Key 0 00 A 11 a 41 @ 71 1 01 B 12 b 42 ‧ 72 2 02 C 13 c 43 ! 73 3 03 D 14 d 44 " 74 4 04 E 15 e 45 $ 75 5 05 F 16 f 46 % 76 6 06 G 17 g 47 & 77 7 07 H 18 h 48 ' 78 8 08 I 19 i 49 ( 79 9 09 J 20 j 50 ) 80 K 21 k 51 + 81 L 22 l 52 , 82 M 23 m 53

  • D-Link DVG-6004S, 35 Advanced Options  There are two levels to enter Web. Administrator is able to change all settings. Web UI only changes some settings. NOTE: Enter new Login ID and password for two levels.  Web UI auto log out: When logging in a web page, if a user does not act within the effective time range, the user will be disconnected from the web page to allow others to login.  Dial Wait Timeout: Use it to set the waiting time for the user’s first key pressing when dialing

  • D-Link DVG-6004S, Some Internet Service Providers (ISP) assigns the bandwidth via the MAC (Media Access Control) Address. You can click the " Clone" button to copy the MAC address of the Ethernet Card installed in the computer used to configure the device. It is only necessary to fill in the field if required by your ISP. The “Your MAC Address” will be blank as you log in through WAN port. Using Phone Books Manager  Enable Phone Books Manager Server: It allows other Gateway users to register the IP address and telephone number in this Phone books manager. It is recommended that the unit appoi

  • D-Link DVG-6004S, These settings are only necessary when the gateway is set up under a NAT that uses a dynamic IP address and do not support DDNS. Choose a DDNS Server: The current system allows users to choose either DynDNS、TZO、3322.org、 PeanutHull or a private server. Please apply for a user account before choosing a service provider.  Server address: Sets up the IP address or URL (Uniform Resource Locator) of the DDNS Server.  Hostname: The URL of the system (or NAT) – apply from a domain name registration providers. 

  • D-Link DVG-6004S, 23 QoS Settings WAN QoS  QoS (Quality of Service): Sets an external bandwidth to ensure sound quality during transmission (When this function is enabled, the voice packet has the highest priority to ensure telecommunication quality while less bandwidth is assigned for data transmission). Some models of the gateway without this function can adjust the bandwidth automatically.  ToS/DiffServ (Type of Service/DSCP): The voice packet has the highest priority to ensure telecommunication quality; the larger the value you

  • D-Link DVG-6004S, 37 Codec  Preferred Codec Type: Since different voice codec have different compression ratios, so the sound quality and occupied bandwidths are also different. It is recommended to use the default provided (G.723.1) because it occupies less bandwidth and will provide better sound quality.  Jitter Buffer: Adjusts the jitter to receive a packet. If the jitter range is too wide, it will delay voice transmission.  Silence Suppression: If one side of a connection

  • D-Link DVG-6004S, 5 Rear Panel DVG-6004S Model FXO ports 1 ~ 4 (telephone connectors) Phone sets connection ports WAN port Connects to broadband Networks such as ADSL, Cable Modem or Router POWER Connects to the power adapter (comes with the gateway) RESET To reset the gateway Or to restore factor y settin g s LAN ports 1 ~ 4 (built-in Ethernet switch) Connect LAN hosts here to share WAN connection. IP sharing features enabled

  • D-Link DVG-6004S, 6 2. Installation and Applications Network Interface The network interface is divided into 3 basic modes as described below:  Gateway can be assigned with a Public IP Address  Gateway can be built under the existing NAT  Gateway can be assigned with a Public IP address and serves as an IP sharing router. Gateway Assigned with a Public IP Address The gateway will have a Public IP address for Internet connection regardless of whether it is a static IP address, DHCP (using a Cable Modem), or PPPoE (Dialup / ADS

  • D-Link DVG-6004S, The IP settings on PC are as follows (using Windows 2000 for example) Open Start->Settings->Control Panel Open Network and Dial-up Connection Open Local Area Connection Click Properties Select TCP/IP, and then click Properties.

  • D-Link DVG-6004S,  Enable Support of SIP Proxy Server / Soft Switch: Enable the functions to inter-work with Proxy Server / Soft Switch. When SIP Proxy 1 and 2 are enabled, the system will register to SIP Proxy 2 after all lines are failed to register to SIP Proxy 1. SIP Proxy 2 is a backup system.  Proxy Server IP/Domain: Enter the Proxy Server IP address or URL (Uniform Resource Locator). You can set 3 redundant Proxy spread by semicolon. EX: 61.123.231.1;12.34.56.78;proxy.sip.sip  Proxy Server Port: Enter the Proxy Server listen port number. (The factory default value is 5060)  Pro

  • D-Link DVG-6004S, Detection in Progress: during detection, the following windows will appear. Once detection of a busy tone is in progress, the system will dial the number to be tested (in this case 36008913). After it rings pick up the phone and enter”#”, then hang up. The system will then detect a busy tone automatically. After detecting it will be as below:

  • D-Link DVG-6004S, 43 Long-Distance Control Table This table controls the level of authority of an outgoing call through FXO. If Level 0 (the highest level) is set to prohibit dialing any number started with prefix 0204, then any level below 0 (including Levels 1 to 5) is also prohibited. If Level 1 is set to prohibit dialing any number with prefix 0, then any level below 1 (including Levels 2 to 5) is also prohibited. Since Level 0 is not restricted to any prefix, therefore at level 0 users can dial a number with the prefix 0. Note: Downward Restriction —If the users at a higher l

  • D-Link DVG-6004S, 55 5. IP Sharing Functions All Gateway series have a built-in IP sharing function. The settings and instructions at a PC end are described below: Current Intranet only supports static IP mode, and the settings at the PC end are as follow: Available IP address Range : 192.168.8.1 – 192.168.8.253 (default address of Gateway is 192.168.8.254) Subnet Mask : 255.255.255.0 Default Gateway : 192.168.8.254 The above values vary with different LAN Port Settings. Assume Gateway’s LAN set

  • D-Link DVG-6004S, 7. Advanced Feature Static Route※ Build static routes within an internal network. These routes will not apply to the Internet.  Route: Enter the IP of the specified network.  Route Mask: Enter the subnet mask to be used for the specified network.  Next Hop IP: Enter the IP address to the specified network.  Inter Face: Select the inter face. RIP(Routing Information Protocol) ※ Establish dynamic routes within an internal network. These routes will not apply to the Internet.  Enable Authentication/Authentication Password:

  • 7 Gateway assigned with a Public IP Address and serving as an IP sharing device The gateway will have a Public IP address regardless of whether it is a static IP application, DHCP (using a Cable Modem), or PPPoE (To connect to your ADSL account), which can then use the func

  • 8 Telephone Interface Description Example for Line Ports : Line Ports connecting directly to the Telephone Line of a PSTN P1-P4 is FXO interfaces and can all be connected to a PSTN to serve as a bridge between the PSTN and other VoIP telephones. The system also allows a call to be made from a traditional telephone line to connect with a user behind the Gateway.

  • D-Link DVG-6004S, SNMP  Enable SNMP Agent: Enable SNMP if ticked.  Get/Set/Trap Community: Enter Community name to Read, Write and Trap.  Trap Host: Enter the IP of Trap Host. NTP This is the time setting. After the gateway is on the Internet, it will set its watch with Time Server.  Time Zone: Set the Time Zone where the gateway resides.  Time Server #1~#3: Set the Time Server where the gateway should sync up during start up. (NTP protocol) Backup/Restore You can backup settings to a file and restore settings f

Related Products and Documents (Gateway):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Kenmore 580. 75063 Owner's manual kenmore/580-75063-8JP.pdf 09 Nov 2023 32
2 DigiTech VOCALIST LIVE 4 Owner's manual digitech/vocalist-live-4-D78.pdf 29 Sep 2022 38 1.03 Mb
3 Sony CDX-GT650UI - Fm/am Compact Disc Player Operating instructions manual sony/cdx-gt650ui-fm-am-compact-disc-player-EFY.pdf 06 Oct 2023 68 1.52 Mb
4 TYAN S1832DL Manual  tyan/s1832dl-JDS.pdf 22 Mar 2023 82 1.21 Mb
5 TRENDnet TEW-692GR Quick installation manual trendnet/tew-692gr-G29.pdf 10 Nov 2023 21 6.12 Mb
6 Simplicity 1690550 Operator's manual simplicity/1690550-P82.pdf 31 Jan 2024 12 0.97 Mb

Similar Resources:

  • WAGO

    I/O-SYSTEM 750

    (132 pages)
    Manual WAGO I/O System 750 753-661/000-004 4FDI 24V PROFIsafe Safe 4-Channel Digital Input; 24 VDC; PROFIsafe Version 1.0.0, valid from HW/SW Version 01/01 …
  • Dr. Neuhaus

    TAINY IQ-LTE

    (2 pages)
    TAINY IQ Sicherheitshinweise Anwenderhandbuch Das Anwenderhandbuch zum TAINY IQ steht für Sie zum Download auf unserer Web-Seite bereit: www.neuhaus.de oder www.sagemcom.com Produkte Die Bezeichnung TAINY IQ wird im Folgenden als Sammelbegriff für das TAINY IQ-LTE und das TAINY IQ-LTE 6E verwendet. Sicherheit Allgemein: Das Produkt TAINY IQ entspr …
  • KAS

    S1

    (2 pages)
    How to Setup KAS S1 Gateway STEP 1 - Download LockKeeper App: Android – Scan QR code iOS – Scan QR code STEP 2 - Setup and Configure Gateway: Scan QR to view latest online guides There are two ways to setup the S1 Gateway. Please follow the instructions relevant to your wiring requirements. Note: You only need to follow one method. PoE Option: (LAN …
  • Wiznet

    WizFi630

    (13 pages)
    © Copyright 2012 WIZnet Co., Ltd. All rights reserved. 1 WizFi630 Hardware Design Guide (Version 1.0) ©2012 WIZnet Co., Ltd. All Rights Reserved. For more information, visit our website at http://www.wiznet.co.kr …
  • Robustel

    GoFixed W800

    (60 pages)
    RobustelGoFixedW8003GADSLWirelessVoIPGatewayforWCDMA/HSUPANetworksUserGuideDocumentName:UserGuide Version:/02.00 Date:2011‐11‐04 Status:� …
  • Sophos

    SG 125

    (2 pages)
    ø3.5162.3ø6.322.21.0ø8ø4United Kingdom and Worldwide SalesTel: +44 (0)8447 671131Email: [email protected] American SalesToll Free: 1-866-866-2802Email: [email protected] and New Zealand SalesTel: +61 2 9409 9100Email: [email protected] SalesTel: +65 62244168Email: [email protected] Kit Mounting Instructions SG 125(w)/135(w …

Comments, Questions and Opinions: