  • D-Link DG-102SP, 69 REPAIR, REPLACEMENT OR REFUND OF THE DEFECTIVE OR NON-CONFORMING PRODUCT. THE MAXIMUM LIABILITY OF D-LINK UNDER THIS WARRANTY IS LIMITED TO THE PURCHASE PRICE OF THE PRODUCT COVERED BY THE WARRANTY. THE FOREGOING EXPRESS WRITTEN WARRANTIES AND REMEDIES ARE EXCLUSIVE AND ARE IN LIEU OF ANY OTHER WARRANTIES OR REMEDIES, EXPRESS, IMPLIED OR STATUTORY Governing Law: This Limited Warranty shall be governed by the laws of the State of California. Some states do not allow exclusion or limitation of incidental or consequential damages, or limitations on how long an implied warranty lasts, so

  • 62 ping <DEST IP> <OPTIONS> Definition: This command lets the user ping an IP address from the device. Parameter(s): <DEST IP: The host ip address> <OPTIONS, -t : Ping the specifed host until stopped (type SPACE). -n count: Number of echo requests to send. -w timeout: Timeout in seconds to wait for each reply. -i interval: The interval in half-seconds between two ech

  • D-Link DG-102SP, 60 Command Line Interface General Setup Commands nwdbg tftp <0|1> Definition: This command sets the software download link to either a WAN link or a LAN link. If only nwdbg tftp is typed, this command shows the download link. Parameter(s): <0:WAN link, 1:LAN link> Example: nwdbg tftp 0 nwdbg ca <NOTIFY ENTITY> Definition: This command sets the address of notify entity. If only nwdbg ca is typed, this command shows the address. Parameter(s): <NOTIFY ENTITY, the format can be: localName@[domainName|ip]:port or [domainName|ip]:port or [domainName|ip]> Example: nwdbg ca 10.1.40.100:2427 nwdbg rgw &l

  • D-Link DG-102SP, 3 Package Contents System Requirements:   Contents of Package: D-Link DG-102SP VoIP Station Gateway Ethernet Cable (Straight-through CAT5 with RJ-45 connectors) 12V/1A A/C Power Adapter If any of the above items are missing, please contact your reseller.   Internet Explorer Version 6.0 or Netscape Navigator Version 6.0 and Above Computers with Windows, Macintosh, or Linux-based operating systems with an installed Ethernet adapter 

  • D-Link DG-102SP, 48 Using the Boot Menu To access the Boot Menu, you must first make sure the console is connected to the Diagnostics port (an RS-232 port with a 9-socket D-shell connector and DCE-type wiring) and the appropriate cabling for the connection is being used. Please see the previous section, “Configuration,” for additional information. Next, power the device on by simply plugging it in. You will see the POST test and the boot up process. During this process, press <Ctrl+C> to reach the Boot Menu. If the boot up process has proceeded too far and the Boot Menu shown below does not appear, unp

  • D-Link DG-102SP, 7 Getting Started Identifying External Components 10/100M: This indicator remains unlit when there is no connection, or the port is operating at 10Mbps through a connection to a 10BASE-T device. It is lit when the port is operating at 100Mbps through a con- nection to a dual-speed or 100BASE-TX Fast Ethernet device. Link/Act: When a good link to a powered-up, but idle device is de- tected on a port, this indicator shines steadily. When packets are re- ceived from the device, the indicator blinks. Rear Panel Line: Lights when PSTN line is in use. Phone 1 to 2: Lights when standard phone port is

  • D-Link DG-102SP, 18 Using Web-Based Management SIP Configuration - Peer to Peer SIP Configuration – Peer to Peer window This window displays the Peer to Peer setting for non-SIP server mode. It lists the ten numbers, which support Peer to Peer communication. Click one of the ten pointer icons to access and edit the second SIP Configuration-Peer to Peer window:

  • D-Link DG-102SP, 17 Using Web-Based Management SIP Configuration - User Agent SIP Configuration – User Agent window The items on this window are described below: Click on the Save button at the bottom right of the screen to save the settings. Same Phone Number: Enable or disable the same phone number function. Index: Choose the Phone 1 or Phone 2. Phone Number: This is a user-defined phone number for each phone port. Display Name: This is a user-defined display name for each phone port. User Agent Port: This is a user-defined unique port numbe

  • D-Link DG-102SP, 6 Getting Started Identifying External Components Front Panel Understanding Indicators Before configuring your VoIP Gateway, take a few minutes to look over this section and familiarize yourself with the front panel LED indicators depicted below. Power: This LED is lit when the device is receiving power; otherwise, it is unlit. Status: This LED will flash quickly when the DG-102SP is either per- forming a self test or booting up. The LED will remain lit when the system is ready for a connection with the call agent. It will remain dark when the s

  • D-Link DG-102SP, 25 Using Web-Based Management Local Server Configuration Second Local Server Configuration Window The items on this window are described below: Index: Choose the index number that you would like to edit (From 1 to 6). Protocol: Choose either the TCP or UDP protocol. Global Port: Enter the designated TCP or UDP protocol port number for the particular protocol packet you wish to redirect. Local Port: Enter the port number used by the designated host on the LAN or use a well-known port. Server IP: Enter the IP address of the local designated host computer or device. State: This toggles Disable and Enable for the Local Server Configuration function. �

  • D-Link DG-102SP, 47 Configuration Using a Console Configuring the VoIP Gateway Using a Web Browser Session Expires: Enter the timer of Expires. Min-SE: Enter the timer of Min-SE. Session Expires Refresher: Choose the session expires refresher: uac or uas. Click on the Save button at the bottom right of the screen to save the settings.    After you have finished, click on the Restart System item in the list at the left of the screen. The following window will appear: Select “Yes” and click on the Restart button at the bottom of the window, the settings will be saved to NV-RAM and reboot system. Your VoIP is now configured for use. Restart System window

  • D-Link DG-102SP, 59 Command Line Interface General Setup Commands nwdbg ip <IP ADDRESS> Definition: This command sets the fixed IP address, which is used as the system’s IP address if the software boot mode is Manual mode. If only nwdbg ip is typed, this command shows the IP configuration. Parameter(s): <IP ADDRESS> Example: nwdbg ip 10.1.1.120 nwdbg mask <SUBNET MASK> Definition: This command sets the fixed subnet mask, which is used as the system’s subnet mask if the software boot mode is Manual mode. If only nwdbg mask

  • D-Link DG-102SP, 53 Using the Boot Menu Update Boot and Application Each item on the Update Boot and Application screen is described below: Software Update Mode: This specifies downloading the image file through a WAN Link. TFTP Server Address: The IP address of the TFTP server where the runtime or configuration file is located. This entry is used only if the Firmware Update is set to Enable. Software Update: Determines whether or not the device will try to look for a runtime image file on the TFTP server. File Name: The complete path and filename of the runtime image file on your TFTP server to be uploaded

  • D-Link DG-102SP, 42 The VoIP gateway comes with a default IP address of 10.1.1.1. You must make sure your computer is in the same Subnet as the VoIP gateway. You can do this by changing the IP address of the computer using the screen shown below. Configuration Using a Console Configuring the VoIP Gateway Using a Web Browser Once this is done, run any browser on the computer and point it to the default IP address of the VoIP as shown below. Initial Window, First Time Connecting to the Web-Based Management Module

  • 10 Configuration Configuring the VoIP Gateway Using a web browser on a computer connected to the device via the WAN or LAN Ethernet connections. In the discussion below, the computer running the browser is referred to as the management station. Using a terminal or computer running terminal emulation software connected to the diagnostic port via an RS-232 cable. In the discussion belo

  • D-Link DG-102SP, 14 The items on this window are described below: Using Web-Based Management Device Information Device Type: This displays the model name of this device. MAC Address: This displays the MAC address of this device. Boot PROM Version: This displays the version number of the device’s startup code. Firmware Version: This displays the version number of the device’s runtime code. DSP Version: This displays the Digital Signal Processor version, if any. Serial Number: This field is for a user-determined identification number. System Name: This is a user-defined name for this device. System Location: This is a user-defined physical location of the device. System Contact: This is user-def

  • D-Link DG-102SP, 16 Using Web-Based Management SIP Configuration - Server The items on this window are described below: IP Address: Enter the IP address of SIP server. Port: Enter the port number of SIP server (Default is 5060). Service Domain: This is a user-defined service domain for SIP server. URL Format: This is a user-defined URL format for SIP server. User Parameter: This is used to enable or disable the function of attach “user=phone” parameter in SIP-URL or not. Timer T2: This is user-defined T2 timer of SIP protocol. (Range: 4, 8, 16, 32 sec) Initial Unregister: Enable

  • 52 System Contact: This is user-defined contact information for the person or department responsible for the maintenance of this device. Serial Number: This displays the serial number of this device Country Code: This is a user-defined country code for this device. < 0:USA (Default), 1:Japan, 2:Hong Kong, 3:Sweden, 4:China > Web Port Number: This is a user-define

  • D-Link DG-102SP, 38 Configuration Using a Console Setting up a Console A typical console connection is illustrated below: Example of a Console Connection Configuring the VoIP Gateway Using Telnet Once you have set an IP address for your device, you can use a Telnet pro- gram (in a VT-100 compatible terminal mode) to access and configure it. Most of the screens are identical, whether accessed from the console port or from a Telnet interface. Console Usage Conventions The console interface uses the following conventions: Items in &

Related Products and Documents (VoIP):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Beko HIC64100 Manual  beko/hic64100-W1X.pdf 05 May 2023 16
2 WaterRower S4 Operating instructions manual waterrower/s4-O31.pdf 30 Dec 2022 9
3 Aimco Lite-Touch Series Repair manual aimco/lite-touch-series-SRB.pdf 15 Aug 2023 20
4 Foscam FI9853EP Quick installation manual foscam/fi9853ep-5O2.pdf 20 Sep 2022 2
5 NEC LCD1830 - MultiSync - 18.1" LCD Monitor Operation & user’s manual nec/lcd1830-multisync-18-1-lcd-monitor-2LO.pdf 31 Oct 2022 31
6 LG W2053TQ Operation & user’s manual lg/w2053tq-9D2.pdf 07 May 2023 28

Similar Resources:

  • ATCOM

    AT-610P

    (40 pages)
    AT-610P User Manual ATCOM TECHNOLOGY CO., LIMITED AT-610P User Manual ISSUE 1.0 2009-9-11 …
  • Cisco

    SPA Series

    (5 pages)
    Troubleshooting SPA Device: FAQ ContentsIntroductionI need some help with my Asterisk proxy configuration. Can you provide me some resources forbeginners?My SPA device rings periodically. Why does this happen, and how do I disable it?I cannot access the voice menu when I press ****. What should I do?I lost the web password for my SPA device. How do I reset i …
  • ZyXEL Communications

    P-2602H-D1A

    (1 pages)
    1/1 www.zyxel.com Declaration of Conformity We, ZyXEL Communications Corp., located at No.6, Innovation Rd II, Science-Park, Hsin-Chu, 300, Taiwan, declare under our sole responsibility that the product: Product information Product Name : 802.11g Wireless ADSL2+ VoIP IAD with Lifeline Model Number :P-2602H-D1A/D3A/D7A, P-2602HW-D1A/D3A/D7A, P-2602HL …
  • iPECS

    eMG80

    (45 pages)
    iPECS eMG80 System DECT Installation Guide Please read this manual carefully before operating System. Retain it for future reference. …
  • Avaya

    PARTNER

    (2 pages)
    Using FLASHThe FLASH button is useful if you have subscribed to custom calling servicesfrom your local telephone company.Press (FLASH) instead of pressing theswitchhook to activate services such as call waiting or 3-way calling.Setting the Volume ControlSet headset volume control to 3.To adjust volume move setting to higher number for higher volume,lowernumb …
  • Grandstream Networks

    GXP1450

    (80 pages)
    GXP2120/GXP2110/GXP2100/GXP14xx USER MANUAL Grandstream Networks, Inc. GXP2120/GXP2110/GXP2100/GXP14xx SIP Enterprise Phones …

Comments, Questions and Opinions: