Datalogic Skorpio-GUN Operation & User’s Manual
|
Datalogic Skorpio-GUN, USE AND FUNCTIONING 3 3.6 DATA CAPTURE CONFIGURATION From the Windows CE Taskbar, tap the "Decoding" icon to open a drop–down menu. Decoding can also be accessed from the Control Panel. By selecting the Info item from this drop-down menu you can access information about the Scanner and the Software; the Configure item opens the configuration applet (Data Capture Configuration Window), while Capture accesses the data capture applet (Data Capture Window), which enables code reading. The last menu item (Wedge)
Datalogic Skorpio-GUN, DATALOGIC SKORPIO™/ SKORPIO-GUN™ 3 3.10 FIRMWARE UPDATE The Datalogic Skorpio™ is equipped with a tool that implements a firmware update service. This tool, called Datalogic Updater (DLUpdater), is compatible with all hardware versions of the following WindowsCE 5.0 models: Datalogic Skorpio™; Datalogic Jet™; Datalogic Kyman™; Datalogic Memor™. The DLUpdater, that is automatically invoked at startup, search for a potential update file (DLUpdate.bin) in the storage card. If it finds it, it proceeds to update only the com
Datalogic Skorpio-GUN, USE AND FUNCTIONING 3 3.7 CONTROL PANEL From the Windows CE Desktop, double tap on the "My Device" icon and then double tap on the "Control Panel" icon to open the Windows CE control panel main window. The Control Panel can also be launched from Start ->Settings ->Control Panel. APPLET programs are displayed as icons; one icon corresponds to each APPLET. Control Panel 3.7.1 Buttons The BUTTONS Applet allows assigning desired applications to be launched by one of the function keys (F1, F2, F3, F4). You can also select to wake up the termi
Datalogic Skorpio-GUN, INTRODUCTION 1 1.6 STYLUS HOLDER The Stylus holder is located in the handle of the Datalogic Skorpio-GUN™ models only: 1.7 ATTACHING THE WRIST STRAP Attach the Wrist Strap (in Datalogic Skorpio-GUN™ models only) as shown in the figures below: 1 2 3 9
Datalogic Skorpio-GUN, ESPAÑOL Las informaciones siguientes son presentadas en conformidad con las disposiciones de las autoridades internacionales y se refieren al uso correcto del terminal. NORMATIVAS ESTÁNDAR PARA LA SEGURIDAD LÁSER Este aparato resulta conforme a las normativas vigentes de seguridad láser a la fecha de producción: CDRH 21 CFR 1040 y EN 60825-1. No es necesario abrir el aparato para la instalación, la utilización o la manutención. ATENCIÓN La utilización de procedimientos o regulaciones diferentes de aquellas describidas en la documentación puede caus
Datalogic Skorpio-GUN, DEUTSCH Die folgenden Informationen stimmen mit den Sicherheitshinweisen überein, die von internationalen Behörden auferlegt wurden, und sie beziehen sich auf den korrekten Gebrauch vom Terminal. NORM FÜR DIE LASERSICHERHEIT Dies Produkt entspricht am Tag der Herstellung den gültigen EN 60825-1 und CDRH 21 CFR 1040 Normen für die Lasersicherheit. Es ist nicht notwendig, das Gerät wegen Betrieb oder Installations-, und Wartungs- Arbeiten zu öffnen. ACHTUNG Jegliche Änderungen am Gerät sowie Vorgehensweisen, die nicht
Datalogic Skorpio-GUN, 6. Limited Warranty. If Customer obtained the Software directly from Datalogic, then Datalogic warrants that during the Warranty Period (as defined below): (i) the media on which the Software is furnished will be free of defects in materials and workmanship under normal use; and (ii) the Software will substantially conform to its published specifications. The “Warranty Period” means a period beginning on the date of Customer’s receipt of the Software and ending on the later of (a) ninety (90) days from the date of initial shipment of the Software by Datalogic, or (b) the end of the minimum perio
INTRODUCTION 1 1.2 AVAILABLE MODELS The brand new Datalogic Skorpio™ is available in different models depending on the options it is equipped with. Options are listed below: • communication options: Wi-Fi 802.11b (Datalogic Skorpio™ models only), Wi-Fi 802.11b/g, Bluetooth® • capture options: Miniature Laser Modules, Long Range Modules (Datalogic Skorpio-GUN™ models only)
Datalogic Skorpio-GUN, REFERENCES CONVENTIONS This manual uses the following conventions: If not otherwise specified, the term Datalogic Skorpio™ refers to both Datalogic Skorpio™ and Skorpio-GUN™ mobile computers. “User” refers to anyone using a Datalogic Skorpio™ mobile computer. “Mobile computer” refers to Datalogic Skorpio™ mobile computer. “You” refers to the System Administrator or Technical Support person using this manual to install, configure, operate, maintain or troubleshoot a Datalogic Skorpio™ mobile computer. REFERENCE DOCUMENTATION For further information regarding Datalogic Skorpio™ refer to the SD
USE AND FUNCTIONING 3 The mobile computer goes into power-off (low power with display backlight off), when it is no longer used for more than a programmable timeout, which is defined in the POWER applet of the Control Panel. In this mode it can be awakened (resuming operation) by the [ON/OFF] key or SCAN key if enabled (see par. 3.7.1). NOTE The mobile computer can also be awaken
Datalogic Skorpio-GUN, MAINTENANCE 4 4 MAINTENANCE NOTE Rechargeable battery packs are not initially charged. Therefore the first operation to perform is to charge them. See below. 4.1 CHARGING THE BATTERY PACK The battery pack autonomy varies according to factors, such as the frequency of barcode scanning, RF usage, etc. When the battery pack is low, the LED positioned at the right side of the display blinks red. It is possible to recharge the battery pack by using the PG5-20 MiniUSB AC/DC Power Supply directly connected to the Datalogic Skorpio™. Alternatively, it is also possible to recharge the battery pack by usi
Datalogic Skorpio-GUN, EN 60950-1, December 2001: InFORMATION TECHNOLOGY EQUIPMENT – SAFETY – P ART 1: GENERAL REQUIREMENTS Lippo di Calderara, March 9th, 2007 Paola Chientaroli Quality Assurance Manager
Datalogic Skorpio-GUN, USE AND FUNCTIONING 3 Figure 2 Startup stylus calibration When starting the terminal, a stylus calibration screen comes up if valid calibration settings are not available. This happens in the following circumstances: 1. At the first startup of the terminal. 2. After restoring registry default settings using the applet Registry Admin and performing a warm boot. 3. After a Clean Boot. 4. After a Firmware Update (see par.3.10). 43
Datalogic Skorpio-GUN, GLOSSARY Access Point A device that provides transparent access between Ethernet wired networks and IEEE 802.11 interoperable radio-equipped mobile units. Hand-held mobile computers, PDAs or other devices equipped with radio cards, communicate with wired networks using Access Points (AP). The mobile unit (mobile computer) may roam among the APs in the same subnet while maintaining a continuous, seamless connection to the wired network. Barcode A pattern of variable-width bars and spaces which represents numeric or alphanumeric data in binary form. The general format of a barcode symbol consists of a leading margin, start character, data or message character, che
USE AND FUNCTIONING 3 3.7.3 Files Admin The FILES ADMIN applet enables control of the permanence of files in the System Folder. Two functions are available on the Files Admin Main window by means of two buttons: Files Admin Main Window Save Session: with this button all files will be permanently saved in the \Windows directory in non-volatile memory. This function g
07 Datalogic Mobile S.r.l. Via S. Vitalino 13 40012 - Lippo di Calderara Bologna - Italy dichiara che declares that the déclare que le bescheinigt, daß das Gerät declare que el Datalogic Skorpio XXX-YYY-ZZZ e tutti i suoi modelli and all its models et tous ses modèles und seine Modelle y todos sus modelos sono conformi alle Direttive del Consiglio
Datalogic Skorpio-GUN, DATALOGIC SKORPIO™/ SKORPIO-GUN™ 4 NOTE Even if the storage temperature range is wider, In order to achieve the longest battery life, store the terminal and the spare batteries between 20 to 30 ºC (68 to 86 ºF). The Batteries must be charged at a temperature ranging from 0° to +45 °C (+32° to +113 °F). 58
Datalogic Skorpio-GUN, DATALOGIC SKORPIO™/ SKORPIO-GUN™ 5 Datalogic Skorpio-GUN™ XXX-2XX only mm 100 200 300 400 0 200 100 300 400 0,25 mm ( 10 mils ) 0,50 mm ( 20 mils ) 1,00 mm ( 40 mils ) Guaranteed Reading Diagram - Reading Zones (10° skew angle) 0 200 600 400 800 1000 1200 1400 1600 1800 2200 2000 mm 0,38 mm ( 15 mils ) 1,4 mm ( 55 mils ) 68
DATALOGIC SKORPIO™/ SKORPIO-GUN™ 1 Other accessories necessary for the Datalogic Skorpio™ connection to the host computer and to the network, must be ordered separately: the cradle, power supply, and one or more connection cables. Remove all the components from their packaging; check their integrity and congruity with the packing documents. CAUTI
Datalogic Skorpio-GUN, USE AND FUNCTIONING 3 For example: Synchronize Microsoft Word and Microsoft Excel files between the Datalogic Skorpio™ and the desktop computer. The files will automatically be converted to the correct format. NOTE Visit the following Microsoft Web site for the latest in updates, technical information, and samples: http://www.microsoft.com/windowsmobile/resources/downloads ActiveSync ® Remote NOTE Microsoft ® ActiveSync ® Remote is no longer supported in Windows CE. For b
Datalogic Skorpio-GUN, DATALOGIC SKORPIO™/ SKORPIO-GUN™ 3 8. Following the operating system upgrade, the message shown in figure 3 may come up at the terminal startup. It informs the user that a flash disk formatting (folder \backup) would required for a clean update and asks whether to proceed with this operation. Select <YES> to format the flash disk. Select <NO> to preserve the current data stored in the backup folder. Sometimes the update process may force a flash format. In these cases the data stored in the backup folder will be irreparably lost. It is therefore recommended to run a backup of the data you want to preserve before starting a firmware update.
Datalogic Skorpio-GUN, TEST CODES 6 6 TEST CODES High Density Codes 0.25 mm (10 mils) Code 39 !17162H! 17162 2/5 Interleaved Ë"8NduÌ 0123456784 Code 128 ÌtestwÎ test 80% EAN 13 x(0B2DE5*KKKKLM( 80% EAN 8 (6450*TRMN( 69
Datalogic Skorpio-GUN, DATALOGIC SKORPIO™/ SKORPIO-GUN™ 3 Two activating procedures are available for Safe Setup: - Select an installation file (for example, a .CAB cabinet file) from the Safe Setup mask. Safe Setup First Mask Then select \Windows or a relevant sub-directory in the path box. Then, Safe Setup will recognize the new files and directories present in the \Windows directory, and will copy them to the \Backup\Windows directory. At the next cold boot, these files will be restored (see par. 3.9). - Simply skip the first mask either by closing it or by pressing the ESC key. When it closes, a new mask will pop up: it will enable any type of installation (even r
Datalogic Skorpio-GUN, USE AND FUNCTIONING 3 3.8.4 FTP Server Setup The Datalogic Skorpio™ Operating System includes a sample File Transfer Protocol (FTP) server. FTP is used for copying files to and from remote computer systems over a network using TCP/IP. You can establish a connection to your Datalogic Skorpio™ using its FTP Server through the following interfaces: WLAN using the WiFi radio LAN through the Datalogic Skorpio™ Ethernet Multi Cradle (see par. 3.7.5) Proceed as follows: 1. Create a registry file (extension .reg) to setup and enable FTP Server communication. A simple example file for anonymous logon is given below: REGEDIT4 [HKEY_LOCAL_MACHINE\
Datalogic Skorpio-GUN, DATALOGIC SKORPIO™/ SKORPIO-GUN™ 3 NOTE Datalogic Skorpio™ Wi-FI models only (without Bluetooth ® ) do not contain the FTP Server. If necessary you can install it from the CD- ROM in the Utilities folder. 52
DATALOGIC SKORPIO™/ SKORPIO-GUN™ 6 Medium Density Codes 0.38 mm (15 mils) Code 39 !17162H! 17162 Interleaved 2/5 Ë"8NduÌ 0123456784 Code 128 ÌtestwÎ test 100% EAN 13 x(0B2DE5*KKKKLM( 100% EAN 8 (6450*TRMN( 70
Datalogic Skorpio-GUN, DATALOGIC SKORPIO™/ SKORPIO-GUN™ 3 Green Spot Duration: determines the duration (measured in milliseconds) of the green spot feedback, which provides a ”good read” green dot directly on the code, where the operator usually tends to be looking. NotPrintableChar: if set to "Remove", all not printable characters included in the scanned data are deleted and the final barcode will include only printable characters. ScanButton: it activates/deactivates the scanner for bar code reading. 32
Datalogic Skorpio-GUN, DATALOGIC SKORPIO™/ SKORPIO-GUN™ 2 2.2 CONNECTION TO USB PERIPHERALS You can use a standard A (4 pin female) to mini A (5 pin male) USB cable to connect the Datalogic Skorpio™ to a keyboard or a memory. For all these devices maximum current withdrawal must be below 100mA. A B C Key: A Keyboard with USB interface C 94A051024 (Standard A to Mini A USB cable) B Datalogic Skorpio™ A B C Key: A Memory with USB interface C 94A051024 (Standard A to Mini A USB cable) B Datalogic Skorpio™ NOTE Datalogic Skorpio™ works with most of mentione
DOWNLOAD |
Datalogic Formula Printer Operation & user’s manual
Formula |
Datalogic Kyman RW420 Printer Brochure
Kyman RW420 |
Datalogic Formula Printer Quick reference manual
Formula |
Datalogic Jet Printer Operation & user’s manual
Jet |
Datalogic Jet Printer Operation & user’s manual
Jet |
Datalogic Skorpio X3 Printer Operation & user’s manual
Skorpio X3 |
Datalogic Skorpio Printer Quick start manual
Skorpio |
Datalogic Skorpio Printer Operation & user’s manual
Skorpio |
# | Manufacturer | Model | Document Type | File | Updated | Pages | Size |
---|---|---|---|---|---|---|---|
1 | Chino | TP-U0260ES | Manual | chino/tp-u0260es-835.pdf | 07 Dec 2023 | 23 | |
2 | Chauvet | DVM-HR | Brochure | chauvet/dvm-hr-Z7L.pdf | 14 Mar 2023 | 4 | 0.99 Mb |
3 | Mitsubishi Electric | WD-60C9 | Service manual | mitsubishi-electric/wd-60c9-XCS.pdf | 17 Feb 2024 | 69 | |
4 | Texas Instruments | TIPRESENTER - TV/Video Presenter For ViewScreen Teacher Calculators | Reference manual | texas-instruments/tipresenter-tv-video-presenter-for-viewscreen-teacher-calculators-YP7.pdf | 17 Aug 2023 | 81 | 1.68 Mb |
5 | Miranda | SDA-122 | Manual to installation and operation | miranda/sda-122-4MW.pdf | 27 Nov 2023 | 12 | |
6 | Philips | AZ1024/05 | Operation & user’s manual | philips/az1024-05-65B.pdf | 05 Nov 2023 | 2 | 0.63 Mb |
Canon
COPYRIGHT © 1999 CANON INC. CANON NP6320 REV.0 DEC. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)REVISION 0FY8-13GF-000DEC. 1999Download Service Manual And Resetter Printer at http://printer1.blogspot.com
…
NP6320(304 pages) |
Digital Equipment
. . . . . . . . . . . . . . . . . . . . . . . DEClaser 3500 PrinterFont ModuleInstallation GuideEK-D350-FI.A01Digital Equipment CorporationMaynard, MassachusettsPart Number 194679-001 - 08/12/94 - - Saved by digital - -Rev # - File Name FONT2.DOC
…
DEClaser 3500(10 pages) |
Canon
FT6-1802 (000)Getting StartedIMPORTANTFor Mac OS users,please refer to P.13EnMise en routeIMPORTANTSi vous utilisez Mac OS,reportez-vous à la P.27FrYou can access canon.com/oip-manual to read the User’s Guide that describes all functions of this machine.
…
imageCLASS D570(36 pages) |
Oki
© 2004 Oki Data Americas, Inc. 58368501Install the Tray1. Unpack the tray and remove the shipping materials.2. Turn off the printer and unplug the power cord.3. Remove the interface cable.4. Note the location of the pins (1), connector (2) and tray opening (3).5. Lower the printer onto the auxiliary tray, aligning the printer with the tray and lowering the …
C5150n(2 pages) |
Brother
Pièce de protectionPièce de protection Windows® Macintosh®Mettez du papier dans la cassette. Vérifiez que la pile de papier est bien à plat dans le bac et qu’elle ne dépasse pas le repère de hauteur.3Réinstallez la cassette dans l'imprimante.4Etape 3 Installez la cartouche de toner.Etape 2 Retirez les cales de protection.Etape 1 Insére …
HL-2460(2 pages) |
Waterpik Technologies
Phone Cablefrom Wall Jack.AquaLink RSTeleLink BoardTo RS4854-ConductorCable(Cable betweenController andPower Center)2Program# of rings(default: 4)Programaccess code(default: 62)®redblackyellowgreen1CautionDo not mount the TeleLink PCB in theAquaLink Power Center. Keep in originalTeleLink enclosure.!The TeleLink enclosure will need to be installed as close …
AQUALINK RS485(1 pages) |
Grandstream Networks Telephone GXP-1105PDF User Guide (@U87B22), Grandstream Networks GXP-1105 Telephone (21.11.2023) GXP-1105, 2 |
Rohm Motherboard BD71837MWVRohm BD71837MWV User Guide (Design manual), @R56D63 BD71837MWV, 47 |
ACS Dryer ACDACS Product User Guide: ACD PDF Manual - H76441 ACD, 31 |
Weber Measuring Instruments Captor 4115.30 sm 4Manual: Weber Captor 4115.30 sm 4 (6HP54A, Upd.Wed 10.2023) Captor 4115.30 sm 4, 4 |
MACROMEDIA Other FIREWORKS MX 2004-EXTENDING FIREWORKSFIREWORKS MX 2004-EXTENDING FIREWORKS Manual - 5N835P FIREWORKS MX 2004-EXTENDING FIREWORKS, 296 |
Omron Personal Care Products HJA-306Omron HJA-306 User Guide (Doc Type: Personal Care Products Instruction manual) HJA-306, 156 |
SIIG Webcam MobileCam/Light ProGuide: SIIG MobileCam/Light Pro (ADH842, Upd.11th Dec 2023) MobileCam/Light Pro, 12 |
Unidare Heater WMF718iUnidare WMF718i User Manual (Installation and operating instructions), @QQFV77 WMF718i, 4 |
American Standard Indoor Furnishing Seva 1480.10XIndoor Furnishing PDF Installation instructions manual Seva 1480.10X, 6 |
Clear-Com Intercom System Tempest 2400 MasterBeltTempest 2400 MasterBelt Reference manual - 2NRK6R Tempest 2400 MasterBelt, 33 |
Paser Receiver meadiaDAB HDPaser meadiaDAB HD Guide (Doc Type: Receiver Instruction manual) meadiaDAB HD, 8 |
Wen Drill 4214Drill #6P78W2 4214, 24 |